We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Fraction Collector: 1-8 of 8

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 16058, 17472, 17967

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188, 15885

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Bio-Rad 2110 HPLC Fraction CollectorImage Coming Soon

Bio-Rad 2110 HPLC Fraction Collector

Cambridge Scientific ID #'s: 4737, 3465

The easy-to-use Model 2110 Fraction Collector provides multiple collection modes for chromatographic separations.

 

Features:

  • Time or drop collection modes (or volume collection mode when connected to the Model EP-1 Econo Pump, BioLogic LP System, or BioLogic DuoFlow System)
  • Collection of 1 drop (~50 µl) to 9 ml fractions in 80 test tubes or microtubes (with optional adaptor)
  • Small chromatography columns can be mounted to drop-forming arm to minimize dead volume
  • Manual-advance tube changes
  • Coldroom compatibility
  • Small footprint of 24 x 33 cm

Specifications:

  • Capacity: Eighty 13 x 100 mm glass, polypropylene, or polystyrene test tubes, or 1.5 ml microtubes when using optional micro tube adaptor
  • Collection basis: 1–999 drops in 1 drop increments, 0.05–9.99 min in 0.01 min increments, 10.0–99.9 min in 0.1 min increments
  • Construction: Case and carousel, polypropylene; front panel, hard-coated polycarbonate
  • Drop former: Silicone rubber
  • Waste outlet tube: Polyurethane
  • Operating temperature: 4–40°C
  • Safety: Meets IEC 61010 and CSA 22.2 certification
  • Dimensions (W x D x H): 24 x 33 x 25 cm
Learn More
Bio-Rad-2110-HPLC-Fraction-Collector-4737
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Gilson FC 203 HPLC Fraction CollectorImage Coming Soon

Gilson FC 203 HPLC Fraction Collector

Cambridge ID #: 7681
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Gilson-FC-203-HPLC-Fraction-Collector-7681
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Gilson FC 203B HPLC Fraction CollectorImage Coming Soon

Gilson FC 203B HPLC Fraction Collector

Cambridge ID #: 4612

The FC 203B is the perfect compact fraction collector, capable of handling a wide variety of collection vessels, including microplates, vials and tubes. The built-in keypad makes setup and operation simple and efficient. Collect fractions by time, drop or peak to suit all your LC applications.

Specifications:

  • Detector Input: +/- 100 mV full scale
  • Drop Counting: Up to 9,999 drops per fraction
  • Maximum Rate: 20 drops/sec
  • Functional Altitude: up to 2000 m
  • Temperature Range: 5–40°C
  • Air Pressure: 75–105 kPa
  • Pollution Degree: 1 or 2
  • Humidity:  80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
  • Event Marker: 100 ms pulse
  • Maximum Collection Volume/Tube: 20 mL (28 x 60 mm 
  • Maximum Fractions: 128 (12 x 75 mm tubes
  • Power Requirements:  50–60 Hz, 100–120 or 220–240V
  • Weight: 5 kg (11 lbs.)
Learn More
Gilson-FC-203B-HPLC-Fraction-Collector-4612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Transgenomic FCW 200 Wave HPLC Fraction CollectorImage Coming Soon

Transgenomic FCW 200 Wave HPLC Fraction Collector

Cambridge ID #: 7376
  • Dual Plate Fraction Collector
  • Learn More
    Transgenomic-FCW-200-Wave-HPLC-Fraction-Collector-7376
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Pharmacia LKB Frac-100 HPLC Fraction CollectorImage Coming Soon

    Pharmacia LKB Frac-100 HPLC Fraction Collector

    Cambridge ID #: 13443

    FRAC-100 (with its drop counting accessory) can collect fractions in a variety of different ways, based either on time, volume or drop counting, controlled via simple programs specified by the operator. For example, you can choose to collect uniform fractions of a fixed time period.

    Specifications:

    • Fraction Size Timing:01-99.99 min (0.01 min increments)
    • Fraction Size Timing: 100-999.9 min (0.1 min increments)
    • Fraction Size Timing: 1000-9 999 min (1 min increments) within an accuracy of ± 0.02%
    • Fraction Size Volume: 01-99.99 ml (0.01 ml increments)
    • Fraction Size Volume: 100-999.9 ml (0.1 ml increments)
    • Fraction Size Volume: 1000-9 999 ml (1 ml increments) within and accuracy of ± 0.02%
    • Maximum Drop Rate: 15 drops/sec
    • Weight: 5 kg
    • Dimensions: 30 x 29 x 39 cm
    • Environment: +4 to +40°C, 20-95% relative humidity
    • Environment: 84-106 kPa (840-1060 mbar) atmospheric pressure
    • Peak Memory: up to 11 peaks
    • Tubing:7 – 2 mm outer diameter