We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Interface: 1-15 of 272

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 35900E HPLC Interface

Agilent 35900E HPLC Interface

Cambridge Scientific ID #'s: 11228, 15239, 9312, 11227

Features:

  • Data buffering
  • Independent analog-to-digital (A/D) converters
  • Real-time control
  • Instrument control ports
  • Host communication
  • Front panel indicators that show run status, interface activity, etc.
  • Compatibility with Agilent data systems
  • External power adapter with 24V DC output
Learn More
Agilent-35900E-HPLC-Interface-11228
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Hewlett Packard 35900E HPLC Interface

Hewlett Packard 35900E HPLC Interface

Cambridge ID #: 16332

Features:

  • Data buffering
  • Independent analog-to-digital (A/D) converters
  • Real-time control
  • Instrument control ports
  • Host communication
  • Front panel indicators that show run status, interface activity, etc.
  • Compatibility with Agilent data systems
  • External power adapter with 24V DC output
Learn More
Hewlett-Packard-35900E-HPLC-Interface-16332
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9592, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - HPLC Stack HPLC System

Agilent 1200 Series - HPLC Stack HPLC System

Cambridge ID #: 9593

Includes:

  • Agilent G1322A Degasser
  • Agilent G1311A Quat Pump
  • Agilent G1329A Autosampler
  • Agilent G1330A Autosampler Chiller
  • Agilent G1365D DAD (Diode Array Detector)
  • Agilent G1316A Column Compartment
  • Solvent Tray
  • Computer Loaded with ChemStation
  • Cables and Manuals
Learn More
Agilent-1200-Series---HPLC-Stack-HPLC-System-9593
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Series - Infinity HPLC Stack HPLC System

Agilent 1260 Series - Infinity HPLC Stack HPLC System

Cambridge ID #: 19866

Includes:
• G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
• G1329B Autosampler
• G1316A Column Compartment
• G4212B Dioade Array Detector
• Computer Loaded with OpenLab Software 
• Monitor – Mouse – Keyboard
• Cables and Manuals

The components can be customized to your needs.

Learn More
Agilent-1260-Series---Infinity-HPLC-Stack-HPLC-System-19866
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Agilent 1100 Series - Prep HPLC Stack  HPLC Preparative System

Agilent Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 18658

Includes:

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Dual Loop Autosampler (Manual Injector also an option)
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

G1361 Prep Pump

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry
Learn More
Agilent-Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-18658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1310A HPLC Isocratic Pump

Agilent 1100 Series - G1310A HPLC Isocratic Pump

Cambridge ID #: 14776

The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

 

 Features:

  • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
  • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
  • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
  • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

 

Specifications:

  • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
  • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
  • Flow range: 2 – 10.0 ml/min
  • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
  • Operating voltage: 230V

 

Learn More
Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 19164, 9165, 13906, 14496, 15507, 16000

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-19164
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - G1311B HPLC Quaternary Pump

Agilent 1100 Series - G1311B HPLC Quaternary Pump

Cambridge ID #: 19933

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311B-HPLC-Quaternary-Pump-19933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1312A HPLC Binary Pump

Agilent 1100 Series - G1312A HPLC Binary Pump

Cambridge Scientific ID #'s: 19857, 15626, 7526, 17475, 13985, 16317, 15936, 16119, 12811, 19156, 16034, 8571, 9300, 19155, 13406, 12452

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1312A-HPLC-Binary-Pump-19857
By clicking below we can further assist you with your inquiry. Inquire 16 In Stock Worldwide Shipping
Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cambridge ID #: 11053

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge Scientific ID #'s: 9625, 9227, 7876, 16066, 15175, 16118

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-9625
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

Cambridge Scientific ID #'s: 16036, 10251, 10893, 18127, 19166

Specification:

  • Detection type: Double-beam photometer
  • Light source: Deuterium lamp
  • Wavelength range: 190–600 nm
  • Short term noise (ASTM): ±0.75×10-5 AU at 254 nm
  • Drift: 3 × 10 -4 AU/hr at 254 nm
  • Linearity: 2 AU (5%) upper limit
  • Wavelength accuracy:
  • Band width: 5 nm typical
  • Flow cells:
    • Standard: 14-μl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
    • High pressure: 14-μl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
    • Micro: 1-μl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
    • Semimicro: 5-μl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
  • Control and data evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter
  • Housing: All materials recyclable.
Learn More
Agilent-1100-Series---G1314A-HPLC-Variable-Wavelength-Detector-16036
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1315A HPLC Diode Array Detector

Agilent 1100 Series - G1315A HPLC Diode Array Detector

Cambridge Scientific ID #'s: 18569, 19152

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-18569
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping