Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Manometric Module: 1-15 of 187

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G2258A HPLC Manometric ModuleImage Coming Soon

Agilent 1100 Series - G2258A HPLC Manometric Module

Cambridge ID #: 18568

The Agilent 1200 Series Dual Loop Autosampler is a fixed loop sampler with two different sample loops. As a consequence of this design the metering device, also referred to as syringe, is not a part of the solvent flow path from pump to HPLC column. An additional flush solvent bottle is used to rinse this part of the hydraulic path after each injection. In order to minimize carryover, the sampler is equipped with a needle wash function which dips the needle into a wash vial or the wash port. The wash port is fed by a peristaltic pump and can be operated with most common HPLC solvents.

 

Specification:

 

  • Weight: 14 kg (29.8 lbs)
  • Dimensions (H x W x D): 200 x 345 x 440 mm (8 x 13.5 x 17 in.)
  • Line voltage: 100 - 240 VAC, ±10 % (wide-ranging capability)
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 200 VA
  • Power consumption (active power): 180 W
  • Ambient operating temperature:  4 - 55 °C (41 - 131 °F)
  • Ambient non-operating temperature: -40 - 70 °C (-4 - 158 °F)
  • Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F) non condensing
  • Operating altitude: up to 2000 meters (6500 ft)
  • Non-operating temperature: top to 4600 meters (14950 ft)
  • Safety standards (IEC, CSA, UL): Installation category II, pollution degree 2
Learn More
Agilent-1100-Series---G2258A-HPLC-Manometric-Module-18568
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Transfer Module HPLC Transfer Module

Waters Transfer Module HPLC Transfer Module

Cambridge ID #: 16974

Transferring sample aliquots from dissolution bath vessels to dissolution dispenser, this high throughput, automated, HPLC platform provides fast and accurate results to suit all HPLC needs.

Specifications:

  • Capacity: 5 x 24-Position Carousels
  • Number of Syringes: 6 to 8 (depending on configuration)
  • Accessories: Power On/Off LED on front panel
Learn More
Waters-Transfer-Module-HPLC-Transfer-Module-16974
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Rainin Pressure Module Pressure ModuleImage Coming Soon

Rainin Pressure Module Pressure Module

Cambridge ID #: 11705

Specifications:

  • Max Pressure: 8700 psi
  • Dimensions (W x D x H): 6-3/8 x 11-1/4 x 5-1/2 inch
Learn More
Rainin-Pressure-Module-Pressure-Module-11705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1323A HPLC Communication Module

Agilent 1100 Series - G1323A HPLC Communication Module

Cambridge Scientific ID #'s: 6836, 16044, 9537

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323A-HPLC-Communication-Module-6836
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1323B HPLC Communication Module

Agilent 1100 Series - G1323B HPLC Communication Module

Cambridge Scientific ID #'s: 16043, 15085

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G4208A HPLC Communication Module

Agilent 1200 Series - G4208A HPLC Communication Module

Cambridge ID #: 19260

Agilent 1200 Series - G4208A

 

The Instant Pilot provides complete local control and monitoring of a single module or an entire Agilent 1100/1200/1260 and 1290 Series HPLC system. There is no data evaluation in the Instant Pilot. The Instant Pilot allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses and basic diagnostics and maintenance.

 

Specifications:

 

  • Dimensions (W x D x H): 130 × 225 × 35 mm (5.1 × 8.9 × 1.4 inches)
  • Weight: 0.8 kg (1.76 lbs)
  • Line Voltage: 22 VDC, ± 10 %
  • Power Consumption: 7 W
  • Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95%, at 25 – 40 °C (77 – 104 °F)
  • Operating Altitude: Up to 3000 m (9842 ft)
  • Non-Operating Altitude: Up to 4600 m (15092 ft)
Learn More
Agilent-1200-Series---G4208A-HPLC-Communication-Module-19260
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G4208A Gameboy HPLC Communication Module

Agilent 1200 Series - G4208A Gameboy HPLC Communication Module

Cambridge ID #: 10777

Bigger, Brighter and in Color

The Agilent 1200 Infinity Series Instant Pilot controller gives you complete control, system monitoring, signal plotting and diagnostic capabilities for a virtually unlimited number of LC system modules. Based on the successful implementation of the industry-standard control area network (CAN) and cabling, used in the first Agilent control module, the Agilent 1200 Infinity Series Instant Pilot is even more powerful.

Features:

  • Complete local control and monitoring of an Agilent 1200 Series, 1260 Infinity
  • and 1290 Infinity system or a single module from a single point. However, not for
  • Agilent 1220 Compact LC.
  • Mixed system configurations supported, e.g. 1200 Series, 1200 Series SL- and
  • 1100 Series.
  • Excellent readability and usability by large colored display with background light,
  • high resolution and contrast.
  • Convenient, ergonomic operation either handheld or at the stack with newly
  • developed, secure attachment.
  • Handheld or attached to a module in a stack to facilitate operator preferences.
  • Easy automation – recalibration intervals and multi-method sequences satisfy
  • the most stringent automation routines.
  • Transfer and archiving of methods, sequences and logbooks via standard USB
  • memory sticks.
  • Factory installed software – flat dialog structure, user configurable interface,
  • enhanced sequence engine, for example with wait for baseline stabilization,
  • diagnosis with passed/failed.
  • GLP – System logbook and module log-books record errors, unusual events and
  • maintenance activities for GLP traceability
Learn More
Agilent-1200-Series---G4208A-Gameboy-HPLC-Communication-Module-10777
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Column Heater Module. HPLC Column Compartment / HeaterImage Coming Soon

Waters Column Heater Module. HPLC Column Compartment / Heater

Cambridge ID #: 7394

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Column-Heater-Module.-HPLC-Column-Compartment---Heater-7394
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Pharmacia LCC-501 Plus HPLC Communication ModuleImage Coming Soon

Pharmacia LCC-501 Plus HPLC Communication Module

Cambridge ID #: 7933

Powerful multifunctional control unit for chromatography systems. Programmable memory allows control of chromatographic procedures, modifications of separation parameters, performance of multidimensional chromatography, as well as evaluation and print out of the chromatogram data.

Specifications:

 

  • Temperature Range: 4 to 40 °C
  • Memory capacity: 50 Methods
  • Dimensions: 16 L x 12 W x 4.7 H (in)

 

Learn More
Pharmacia-LCC-501-Plus-HPLC-Communication-Module-7933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu Prominence CBM-20A HPLC Communication Module

Shimadzu Prominence CBM-20A HPLC Communication Module

Cambridge ID #: 18631

Description:

System controller equipped with a data buffering function and acts as an interface for connecting LC workstations, network-client computers, and analytical instruments via Ethernet. Up to eight units can be connected to the box-type CBM-20A. The card-type CBM-20Alite is used by incorporating it into an LC-20A-Series solvent delivery pump or auto-sampler. It can control up to five units, including the unit in which it is incorporated.

 

Specifications:

 

Connectable Units:

Solvent delivery units: 4 max
Autosamplers: 1
Column ovens: 1
Detectors: 2 max
Fraction collectors: 1
Sub-controllers: 2 max."
Number of connectable units: 8 (expansion possible up to 12)
Data Buffering: Approx. 24 hours for one analysis (at 500 ms sampling rate; available only with LCsolution)
Event I/O: 4 inputs, 4 outputs
Analog Boards: Up to 2 boards can be mounted
Operating temperature range: 4°C to 35°C
Dimensions, weight: 260 (W) x 140 (H) x 420 (D) mm, 5.5 kg
Power requirements: 100 VAC, 100VA, 50/60HZ

Learn More
Shimadzu-Prominence-CBM-20A-HPLC-Communication-Module-18631
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Temperature Control Module II HPLC Column Compartment / HeaterImage Coming Soon

Waters Temperature Control Module II HPLC Column Compartment / Heater

Cambridge ID #: 7396

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Temperature-Control-Module-II-HPLC-Column-Compartment---Heater-7396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Pharmacia UV-1 HPLC Communication ModuleImage Coming Soon

Pharmacia UV-1 HPLC Communication Module

Cambridge ID #: 11917

Description:

Single Path Monitor UV-1 is a dual beam flow through UV absorptiometer for monitoring the UV absorption of a flowing liquid at 254nm, 280 nm, or 405 nm, comes with the UV-1 control unit, optical unit, one 280 nm wavelength filter and one 280 nm converter, and with a flow cell with optical path length of either 3 mm or 10 mm.

Learn More
Pharmacia-UV-1-HPLC-Communication-Module-11917
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE AKTAxpress Single Module FPLC System

Amersham Biosciences GE AKTAxpress Single Module FPLC System

Cambridge ID #: 11554

 

ÄKTAxpress Module

 

ÄKTA xpress is a chromatography system designed for automated, multistep protein purification of both single and multiple samples.

  • Unattended purification: Built-in purification knowledge combines software, hardware, and prepacked columns to eliminate time-consuming manual tasks.
  • Highest possible purity: Optimized protocols with up to four steps will deliver tagged proteins of near 100% purity. Built-in cleaning procedures between MAb samples to minimize carry over
  • High productivity: Each module can purify up to four proteins. The modular design offers adaptability to meet increased throughput needs.
  • Yield : The system is capable of purifying target proteins in yields varying from 1 to 50+ mg.
  • Akta Express has a Small footprint: A compact design allows the system to occupy minimal space on the bench or in the cold room.

 

ÄKTAxpress Module

  • Complete Packsize: 1 Piece
  • Application: Unattended multistep purification of tagged proteins and antibodies
  • Flow Rate: 0.1-65 ml/min
  • Operating Pressure Max.: 3 MPa (435 psi)
  • Tubing i.d. [Flow Path]: 1 mm
  • Single Wavelength Detection: Mercury lamp and 254 and 280 nm filters included. Optional filters for 313, 365, 405, 436 and 546 nm.
  • Multiple Wavelength Detection: No
  • Flow Cell Path Length: 2 mm
  • Multiple Sample Injection: Yes, up to 4 samples
  • Autosampler Injection: No
  • Automatic Buffer Preparation: No
  • Buffer Selection: 10 buffer inlets
  • Multi-Step Purification: Yes, up to 4 steps
  • Relative Humidity: 20%-95% (non condensing)
  • pH Stability Long Term: 2-12
  • pH Stability Short Term: 1-14
  • Viscosity: max 5 cP
  • Width: 250 mm
  • Height: 660 nm
  • Depth: 600 mm
  • Weight: 30 kg
  • Voltage: 100-120/220-240 VAC
  • Power Consumption: 120 VA
  • Protection Class: IP 20
  • Pump Type: Piston pump, metering type
Learn More
Amersham-Biosciences-GE-AKTAxpress-Single-Module-FPLC-System-11554
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
ChemTec Tandem 1081 Pump Control Module

ChemTec Tandem 1081 Pump Control Module

Cambridge Scientific ID #'s: 16642, 16439

The ChemTec provides programmable feed scheduling for chemical reactors, bioreactors and fermenters either by weight or volume. Both linear and exponential feed strategies can be readily implemented. When interfaced with an electronic balance, the ChemTec can also be used to maintain vessel or reactor weight in diafiltration or perfusion applications, it can also act as a pH controller for pH maintenance or simple end point titration. 

Specifications:

  • Pump Output: 0.03 ml/min to 2,250 ml/min
  • Tubing Sizes: #13, 14, 16, 17, 18, and 25
Learn More
ChemTec-Tandem-1081-Pump-Control-Module-16642
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters WAT200341 Pump Control ModuleImage Coming Soon

Waters WAT200341 Pump Control Module

Cambridge ID #: 6103
  • Voltage: 5, 12 -12 VDC
  • Amps: .8, .01 .01
  • VA: .4, .12, .12
  • Learn More
    Waters-WAT200341-Pump-Control-Module-6103
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping