We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Nano Pump: 1-15 of 298

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G2226A HPLC Nano Pump

Agilent 1200 Series - G2226A HPLC Nano Pump

Cambridge ID #: 12658

This Agilent 1200 Model G2226A ( G 2226A, G 2226 A, G2226 A ) Series Nano (NanoFlow) Pump is in excellent condition!  The Agilent 1200 Series nanoflow pump uses a unique solvent delivery technology optimized for nanoliter-per-minute flows and features EFC (Electronic Flow Control) with active feedback and real time flow adjustment. EFC is the gold standard for robust and reliable nanoflow performance and delivers the precise flow and gradient performance necessary for retention time reproducibility and stable ion generation essential for high sensitivity nanospray MS performance.

Features:

  • Electronic Flow Control (EFC) provides real-time adjustment of the flow rate throughout the analysis for reliable and reproducible results.
  • Micro vacuum degassing with very low internal volume per channel (1 mL) for fast changeover of mobile phase and quick purge.
  • Control from handheld controller for convenient local status monitoring.
  • 2nd generation flow sensors.
  • Application focus: High resolution separations and high sensitivity MS detection. Proteomics is a typical application area for the nanoflow pump.

 

Learn More
Agilent-1200-Series---G2226A-HPLC-Nano-Pump-12658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 LPG-3600 HPLC Nano Pump

Dionex Ultimate 3000 LPG-3600 HPLC Nano Pump

Cambridge ID #: 12558

Features:

 

HPLC nano pump



Specifications:

 

 

  • Flow range selection: 10 °l/min to 2500 °l/min
  • Gradient accuracy: Typically ° 1.0 % at 200 °l/min
  • Gradient precision: Typically < 0.5 % at 200 °l/min
  • Pressure range: 0.1 - 50 MPa (7250 psi)Worldwide Shipping

 

 

Learn More
Dionex-Ultimate-3000-LPG-3600-HPLC-Nano-Pump-12558
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex FLM-3300, NANO, 1X2P-10P HPLC Degasser

Dionex FLM-3300, NANO, 1X2P-10P HPLC Degasser

Cambridge ID #: 10565

Description:

The UltiMate 3000 Flow Manager FLM-3000 series features the UltiFlow eluent delivery system for nano, capillary, and micro flow rates. It integrates column thermostatting and includes up to two low-dispersion switching valves for automated sample preparation and multidimensional LC applications.

  • UltiFlow technology for nano, capillary, and micro flow rates (50 nL/min–160 µL/min)
  • Electronical nano, capillary and micro flow control for high retention time precision
  • Easy change of flow rate range (nano, cap, or micro) by exchanging the splitter cartridge
  • Column thermostatting from 5 to 70 ºC, (max. 15 ºC below ambient)
  • Short warm-up/cool-down times for fast temperature stabilization
  • Column capacity of up to three microcolumns (max length: 30 cm)
  • Thermostatted microswitching valves for maximum application flexibility
  • Biocompatible versions for delicate biomolecule analyses and high salt applications
  • Enables Proteomics MDLC solutions

Specifications:

  • Temperature Range: 5–70°C or 15°C below ambient
  • Temperature Accuracy: ±0.5°C
  • Temperature Stability and Precision: ±0.1°C
  • Heat-Up and Cool-Down Time: from 20°C to 50°C in less than 25 min, from 50°C to 20°C in less than 35 min
  • Switching Valves: two low-dispersion thermostatted 2-position 10-port micro valves
  • Column Capacity: up to three columns, max. 30 cm length
  • Flow Splitter/Control: thermostatted nano, capillary, or micro splitter with automatic identification system
  • Flow Range Selection: 50–1000 nL/min (nano), 0.5–10 µL/min (capillary), 10–160 µL/min (micro flow splitter)
  • Maximum Column Pressure: 35 MPa (4900 psi)
Learn More
Dionex-FLM-3300,-NANO,-1X2P-10P-HPLC-Degasser-10565
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Pall Corporation iCELLis Nano Bioreactor

Pall Corporation iCELLis Nano Bioreactor

Cambridge ID #: 22016
  • Cell culture process simplification, from vial to product
  • Fully-integrated, single-use bioreactor with disposable, pre-installed calibrated probes
  • Unique waterfall system for optimal oxygenation and CO2 stripping
  • Straightforward implementation for faster process development
  • Predictable scalability from R&D to manufacturing
  • Compact high-cell-density, fixed-bed bioreactor providing a significant increase in volumetric
  • productivity vs. traditional stirred tanks
  • Significant decrease in operational costs and capital investments vs. classical 2D flatware
  • Learn More
    Pall-Corporation-iCELLis-Nano-Bioreactor-22016
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Electron Accela 600 Pump HPLC Quaternary Pump

    Thermo Electron Accela 600 Pump HPLC Quaternary Pump

    Cambridge ID #: 11202

    Features:

    The 600 pumps is quaternary, low-pressure mixing pumps with a built-in solvent degassing system and an automatic calibration feature.

    Specifications:

    • Flow rate range: 1 to 5000 μL/min
    • Backpressure range: 0 to 600 bar (8702 psi)
    • Residual pulsation: < 2 bar Amplitude
    • Flow rate accuracy: ±0.5% or 1 μL/min, whichever is greater
    • Gradient composition accuracy: ±0.5% absolute
    • Gradient resolution: 1% from 0 to 100%
    • Firmware version: (November 2010) 23.67 e
    • Gradient composition range: 0 to 100% from up to 4 independent feed channels employing 2 of them at the same time
    • Delay volume 90 μL (LDA): + 65 μL (static mixer)
    Learn More
    Thermo-Electron-Accela-600-Pump-HPLC-Quaternary-Pump-11202
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Harvest Right Scroll Pump - SP-GW11060 Dry Vacuum PumpImage Coming Soon

    Harvest Right Scroll Pump - SP-GW11060 Dry Vacuum Pump

    Cambridge ID #: 24155
    This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
    Learn More
    Harvest-Right-Scroll-Pump---SP-GW11060-Dry-Vacuum-Pump-24155
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Cambridge ID #: 14776

    The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

     

     Features:

    • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
    • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
    • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
    • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

     

    Specifications:

    • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
    • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
    • Flow range: 2 – 10.0 ml/min
    • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
    • Operating voltage: 230V

     

    Learn More
    Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Cambridge Scientific ID #'s: 9165, 22111, 14496, 21293

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-9165
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

    Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

    Cambridge ID #: 22470

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Hewlett-Packard-1100-Series---G1311A-HPLC-Quaternary-Pump-22470
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1311B HPLC Quaternary Pump

    Agilent 1100 Series - G1311B HPLC Quaternary Pump

    Cambridge ID #: 19933

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1100-Series---G1311B-HPLC-Quaternary-Pump-19933
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1312A HPLC Binary Pump

    Agilent 1100 Series - G1312A HPLC Binary Pump

    Cambridge Scientific ID #'s: 15626, 16317, 15936, 16119, 12811, 19156, 16034, 13406, 23208, 12452

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
    By clicking below we can further assist you with your inquiry. Inquire 10 In Stock Worldwide Shipping
    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cambridge ID #: 11053

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1361A HPLC Preparative Pump

    Agilent 1100 Series - G1361A HPLC Preparative Pump

    Cambridge Scientific ID #'s: 18544, 18566, 18543

    Features:

    • Extended flow rate range
    • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
    • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
    • Automated seal wash using a peristaltic pump extends seal lifetime
    • Pumps stop in response to column blockage or leaks
    • Automated electromagnetic purge valve simplifies system setup
    • Software provides solvent level control that keeps the pump from running dry

     

    Can be sold as an individual component or as part of a complete stack

     

    Learn More
    Agilent-1100-Series---G1361A-HPLC-Preparative-Pump-18544
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1376A HPLC Capillary Pump

    Agilent 1100 Series - G1376A HPLC Capillary Pump

    Cambridge Scientific ID #'s: 9564, 15081, 17698

    Specifications:

    • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
    • Settable column flow Range:
      • – 20 µl/min
      • – 100 µl/min (with the extended flow range kit)
      • – 2.5 µl/min (with the electronic flow control bypassed)
    • Recommended column flow range:
      • – 20 µl/min
      • 10 – 100 µl/min (with extended flow range kit)
      • – 2.5 ml/min (with the electronic flow sensor bypassed)
    • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
    • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
    • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
    • Delay volume:
      • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
      • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
      • for flow rates up to 100 µl/min and electronic flow control active:
      • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
      • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
    • Pressure range: 20 to 400 bar (5880psi) system pressure
    • Compressibility Compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog output For pressure monitoring, 2 mV/bar, one output
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
    • Housing: All materials recyclable
    Learn More
    Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1200 Series - G1311A HPLC Quaternary Pump

    Agilent 1200 Series - G1311A HPLC Quaternary Pump

    Cambridge Scientific ID #'s: 24124, 22623, 24131, 23893

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-24124
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping