Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Preparative Autosampler: 16-30 of 165

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge ID #: 21013

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-21013
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G1329B HPLC Autosampler

Agilent 1260 Infinity Series- G1329B HPLC Autosampler

Cambridge ID #: 19979

Features:

The Agilent 1260 Infinity II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses. It can house optionally the integrated column compartment for two LC columns with temperature control up to 80 °C, as well as a sample thermostat for stable temperature control from 4 °C - 40 °C, all within one module.

 

Specifications:

  • High capacity - up to 132 vials (2 mL) or up to 36 vials (6 mL).
  • Reliable injections -  0.1 to 100 µL injections for up to 600 bar (G7129A) and up to 800 bar (G7129C).
  • Easy volume extensions- for injection volumes up to 1,500 µL (G7129A), or up to 1,800 µL (G7129C) for applications ranging from microbore to semi-preparative chromatography.
  • Lowest carryover - with an in needle flush port included, for rinsing the outside of the needle.
  • Efficient temperature control - with an integrated column compartment as an option or upgrade available. Which holds two columns up to 30 cm length, and provides heating capacity from 5 degrees above ambient up to 80 °C for reproducible chromatography data at optimized resolution.
  • Integrated sample thermostat- available as an option or upgrade, providing cooling and heating (with thermostat) in the range from  4 °C - 40 °C.
  • Low internal volume - for minimum contribution to a system's total internal volume, which can be even further reduced using bypass mode.
  • Increased productivity - with overlapped injections.
  • Customizable injection program - available for customizing advanced injections as well as for sample preparation steps upfront injection.
Learn More
Agilent-1260-Infinity-Series--G1329B-HPLC-Autosampler-19979
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 20569, 20795

Features:

The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials

Specifications:

  • Temperature Range: Settable from 4 °C to 40 °C in 1 ° increments
  • Temperature Accuracy at Ambient
    • Temperatures < 25 °C and humidity < 50 %: 3 °C to 8 °C at a setpoint of 4 °C*
  • Temperature Accuracy at Ambient Temperatures
    • temperatures  < 30 °C and humidity < 60 %: 3 °C to 9 °C at a setpoint of 4 °C*
Learn More
Agilent-1290-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-20569
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1290 Series - G4226A HPLC Autosampler

Agilent 1290 Series - G4226A HPLC Autosampler

Cambridge ID #: 20794

Features:

The 1290 Infinity Autosampler features an increased pressure range enabling the use of today’s column technology (sub- two- micron narrow bore columns) with the Agilent 1290 Infinity LC System. Increased robustness is achieved by optimized new parts, high speed with lowest carry- over by flow through design, increased sample injection speed for high sample throughput, increased productivity by using overlapped injection mode and flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384- well plates allows you to process up to 768 samples unattended.

Specifications:

 

  • Injection range: 0.1 – 20 µL in 0.1 µL increments 0.1 – 40 µL in 0.1 µL increments if 40 µL loop is installed 0.1 – 120 µL in 0.1 µL increments with 1290 Infinity large volume injection kit (hardware modification required) pressure range up to 1200 bar 0.1 – 100 µL in 0.1 µL increments with 100 µL upgrade kit (G4214A) (hardware modification required) up to 600 bar
  • Precision: Typically <0.25 % RSD from 5 – 20 µL, Typically <0.5 % RSD from 2 – 5 µL volume, Typically <0.7 % RSD from 1 – 2 µL volume.
  • Pressure range:  Up to 1200 bar, Up to 600 bar 
  • Sample viscosity range: 0.2 – 5 cp
  • Sample capacity: Capacity 2 x well plates (MTP) + 10 x 2 mL vials, 108 x 2 mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials, 30 x 6 mL vials in 2 x 15 vial plate, 100 Micro vial tray, plus 10 additional 2 mL vials, 54 Eppendorf tubes (0.5/1.5/2 mL) in 2 x 27 Eppendorf tube plate.
Learn More
Agilent-1290-Series---G4226A-HPLC-Autosampler-20794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 4000 w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14794

Includes 1 year Service Contract, Installation, and a PM at 6 months

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-14794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 15382

Innovative QJet ion guide technology dramatically improves sensitivity by capturing and focusing more ions generated by the efficient TURBO V ion source. And the TURBO V source virtually eliminates cross-contamination, even with high-concentration samples.  New innovations in sensitivity like QJet ion guide technology make it possible to reach the lowest limits of detection. Combining QJet ion guide technology with the proven TURBO V ion source and a powerful new generation of Analyst software results in a robust, high throughput platform ideal for all phases of pharmaceutical development.

 

Includes:

  • AB Sciex API5000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse-counting channel electron multiplier (CEM) detector
  • Dynamic Range: 1 cps to 4 x 10(6) cps (pulse counting)
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.01% over the entire mass range
  • Mass Range: 5 – 1250 m/z
  • Scan Types:  Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Learn More
AB-Sciex-API-5000-LC-MS-MS-Mass-Spectrometer-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-15382
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 11220, 12890, 12872, 12869, 11959, 12661, 13515, 13511, 13518, 15896, 13516, 13517, 12867, 12868, 12873, 12660

The Leap technologies CTC PAL HTC Auto sampler for HPLCs offer Precise and Accurate sample Loading, high throughput, flexible analysis while taking up limited bench space.

 

Includes:

  • HTC PAL Autosampler (Width: 534mm Depth: 385mm Height: 648mm)
  • Temperature controlled sample storage 3 drawer
  • XYZ injector/Arm
  • LC Injection valve- 6 port
  • Wash station
  • Gameboy controller
  • Power Supply
  • Manual
Learn More
Leap-Technologies-CTC-Analytics-HPLC-Well-Plate-Autosampler-11220
By clicking below we can further assist you with your inquiry. Inquire 16 In Stock Worldwide Shipping
Thermo PAL HTC-Accela1-TMO HPLC Well Plate Autosampler

Thermo PAL HTC-Accela1-TMO HPLC Well Plate Autosampler

Cambridge ID #: 15946

Specifications:

  • Unit Power Supply: (Input) 100-240VAC, 50-60Hz, 4A, (Output) 36VDC, 4.16A
  • Cooler Power Supply: (Input) 100-240VAC, 50-60Hz, 2A, (Output) 24VDC, 4.5A
  • Cooling stack
  • Waste Station
  • Valve
  • Hand Held Controller
Learn More
Thermo-PAL-HTC-Accela1-TMO-HPLC-Well-Plate-Autosampler-15946
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 ACC-3000  HPLC Autosampler

Dionex Ultimate 3000 ACC-3000 HPLC Autosampler

Cambridge ID #: 20019

Features:

Reduce the size and cost of your liquid chromatography (LC) system. The Dionex UltiMate ACC-3000 Autosampler Column Compartments provides a cost-effective solution for conventional LC and UHPLC applications at up to 62MPa (9000 psi) operating pressure. It integrates an autosampler and column compartment (with optional sample thermostatting) in a single module and offers performance and flexibility that exceed most analytical method requirements. The number of wear parts have been minimized for trouble-free operation.

Specifications:

  • Injection Cycle Time: <45 sec.
  • Injection Volume Precision: <0.25%
  • Injection Volume Range: 1 to 200 µL
  • Injection Type: Pulled Loop
  • Sample Capacity: 3 racks
  • Max. Pressure: 620 bar/9000 psi
  • Biocompatible Version: No
  • Linearity: >0.9995
  • Voltage: 100 to 120 V
  • Weight (Metric): 18 kg
  • Description: ACC-3000 Autosampler Column Compartment
  • Carryover: <0.02%
Learn More
Dionex-Ultimate-3000-ACC-3000-HPLC-Autosampler-20019
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 WPS-3000TB HPLC Autosampler

Dionex Ultimate 3000 WPS-3000TB HPLC Autosampler

Cambridge ID #: 17924

Specifications:

  • Sample capacity: Dependent on the carousel configuration: Vials/ Well plates
  • Injection methods: Inline split-loop
  • Injection volume settable range: 0.01 – 100 µL (1 – 100 µL)
  • Injection volume accuracy: Typically ±0.5% at 50 and 90 µL
  • Minimum sample required: 1 µL out of 5 µL (250 µL conical vial)
  • Injection cycle time: <15 seconds for 5 µL
Learn More
Dionex-Ultimate-3000-WPS-3000TB-HPLC-Autosampler-17924
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 WPS-3000TSL HPLC Autosampler

Dionex Ultimate 3000 WPS-3000TSL HPLC Autosampler

Cambridge ID #: 18419

Specifications:

  • Sample capacity: Dependent on the carousel configuration: Vials/ Well plates
  • Injection methods: Inline split-loop
  • Injection volume settable range: 0.01 – 100 µL (1 – 100 µL)
  • Injection volume accuracy: Typically ±0.5% at 50 and 90 µL
  • Minimum sample required: 1 µL out of 5 µL (250 µL conical vial)
  • Injection cycle time: <15 seconds for 5 µL
Learn More
Dionex-Ultimate-3000-WPS-3000TSL-HPLC-Autosampler-18419
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE A-900 FPLC Autosampler

Amersham Biosciences GE A-900 FPLC Autosampler

Cambridge ID #: 6705

Features:

  • Loop volume 5-1000µl
  • 96 vials 1.5 ml vial capacity
  • A-900 autosampler designed for use with AKTA
  • Syringes 100 - 1000 µl
  • Built-in compressor
Learn More
Amersham-Biosciences-GE-A-900-FPLC-Autosampler-6705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE A-905 FPLC Autosampler

Amersham Biosciences GE A-905 FPLC Autosampler

Cambridge Scientific ID #'s: 14178, 14177

Features:

  • A-905 is an automated sampling injector for use with AKTA systems
  • Sample capacity: 96-well and 384-well microplates
  • Maximum total plate height: 47 mm
  • Dispenser syringe: 250 - 1000 µL
  • Loop volume: 5 - 1000 µL
  • Built-in compressor
Learn More
Amersham-Biosciences-GE-A-905-FPLC-Autosampler-14178
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Rainin AI-200 AutosamplerImage Coming Soon

Rainin AI-200 Autosampler

Cambridge ID #: 4616

The Rainin Al-200 AutoSampler offers the best of both worlds. It is intelligent for research applications yet rugged enough for routine quality control work. 

Specifications:

  • Syring: 250 uL
  • Injection Loop Volume: 10 uL
  • Tubing Needle Volume: 15 uL
  • Buffer Tubing Volume: 500 uL
  • Power Input: 115-230V
  • Dimensions: 13.4 in. x 11.8 in. x 19.7 in. (H x W x D) 
Learn More
Rainin-AI-200-Autosampler-4616
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping