We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Preparative Pump: 1-15 of 304

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1361A HPLC Preparative Pump

Agilent 1100 Series - G1361A HPLC Preparative Pump

Cambridge Scientific ID #'s: 18544, 18566, 18567, 18543

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry

 

Can be sold as an individual component or as part of a complete stack

 

Learn More
Agilent-1100-Series---G1361A-HPLC-Preparative-Pump-18544
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Agilent 1100 Series - Prep HPLC Stack  HPLC Preparative System

Agilent Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 18658

Includes:

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Dual Loop Autosampler (Manual Injector also an option)
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

G1361 Prep Pump

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry
Learn More
Agilent-Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-18658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative AutosamplerImage Coming Soon

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Electron Accela 600 Pump HPLC Quaternary Pump

Thermo Electron Accela 600 Pump HPLC Quaternary Pump

Cambridge ID #: 11202

Specifications:

  • Flow rate range: 1 to 5000 μL/min
  • Backpressure range 0 to 600 bar (8702 psi)
  • Residual pulsation < 2 bar Amplitude
  • Flow rate accuracy ±0.5% or 1 μL/min, whichever is greater
  • Gradient composition accuracy ±0.5% absolute
  • Gradient resolution 1% from 0 to 100%
  • Firmware version (November 2010) 23.67 e
  • Gradient composition range 0 to 100% from up to 4 independent feed channels employing 2 of them at the same time
  • Delay volume 90 μL (LDA) + 65 μL (static mixer)
Learn More
Thermo-Electron-Accela-600-Pump-HPLC-Quaternary-Pump-11202
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Harvard Apparatus Pump 11 Syringe Pump

Harvard Apparatus Pump 11 Syringe Pump

Cambridge Scientific ID #'s: 11359, 18704, 13813, 13812

Features:

  • Single Syringe Holder
  • Flow Rate Maximum: 26.55 ml/min wih 50/60 ml syringe.4 ml/hr
  • Flow Rate Minimum: 0.0014 µl/hr with 0.5 µl syringe
  • Syringe Size Maximum: 50/60 ml
  • Syringe Size Minimum: 10 ul
  • Voltage Range: 95-240 VAC, 50/ 60 Hz
Learn More
Harvard-Apparatus-Pump-11-Syringe-Pump-11359
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
KD Scientific Syringe Pump Syringe PumpImage Coming Soon

KD Scientific Syringe Pump Syringe Pump

Cambridge ID #: 7637
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
KD-Scientific-Syringe-Pump-Syringe-Pump-7637
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Variable Speed Pump Electrophoresis Pump

Bio-Rad Variable Speed Pump Electrophoresis Pump

Cambridge ID #: 13115
  • 120 V, pulsed field gel electrophoresis pump, for use with any CHEF system
  • Learn More
    Bio-Rad-Variable-Speed-Pump-Electrophoresis-Pump-13115
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Cambridge ID #: 14776

    The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

     

     Features:

    • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
    • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
    • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
    • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

     

    Specifications:

    • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
    • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
    • Flow range: 2 – 10.0 ml/min
    • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
    • Operating voltage: 230V

     

    Learn More
    Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Cambridge Scientific ID #'s: 14613, 16067, 19164, 16337, 9165, 16848, 13906, 14496, 15507, 16000, 16142

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-14613
    By clicking below we can further assist you with your inquiry. Inquire 11 In Stock Worldwide Shipping
    Agilent 1100 Series - G1312A HPLC Binary Pump

    Agilent 1100 Series - G1312A HPLC Binary Pump

    Cambridge Scientific ID #'s: 15626, 7526, 17475, 13985, 16317, 15936, 16119, 12811, 19156, 16034, 8571, 9300, 19155, 13406, 12452

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
    By clicking below we can further assist you with your inquiry. Inquire 15 In Stock Worldwide Shipping
    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cambridge ID #: 11053

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1376A HPLC Capillary Pump

    Agilent 1100 Series - G1376A HPLC Capillary Pump

    Cambridge Scientific ID #'s: 9564, 15081, 17698

    Specifications:

    • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
    • Settable column flow Range:
      • – 20 µl/min
      • – 100 µl/min (with the extended flow range kit)
      • – 2.5 µl/min (with the electronic flow control bypassed)
    • Recommended column flow range:
      • – 20 µl/min
      • 10 – 100 µl/min (with extended flow range kit)
      • – 2.5 ml/min (with the electronic flow sensor bypassed)
    • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
    • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
    • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
    • Delay volume:
      • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
      • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
      • for flow rates up to 100 µl/min and electronic flow control active:
      • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
      • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
    • Pressure range: 20 to 400 bar (5880psi) system pressure
    • Compressibility Compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog output For pressure monitoring, 2 mV/bar, one output
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
    • Housing: All materials recyclable
    Learn More
    Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1200 Series - G1311A HPLC Quaternary Pump

    Agilent 1200 Series - G1311A HPLC Quaternary Pump

    Cambridge ID #: 18525

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1200-Series---G1311A-HPLC-Quaternary-Pump-18525
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping