Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Transfer Module: 1-15 of 255

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Waters Transfer Module HPLC Transfer Module

Waters Transfer Module HPLC Transfer Module

Cambridge ID #: 16974

Transferring sample aliquots from dissolution bath vessels to dissolution dispenser, this high throughput, automated, HPLC platform provides fast and accurate results to suit all HPLC needs.

Specifications:

  • Capacity: 5 x 24-Position Carousels
  • Number of Syringes: 6 to 8 (depending on configuration)
  • Accessories: Power On/Off LED on front panel
Learn More
Waters-Transfer-Module-HPLC-Transfer-Module-16974
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Rainin Pressure Module Pressure ModuleImage Coming Soon

Rainin Pressure Module Pressure Module

Cambridge ID #: 11705

Specifications:

  • Max Pressure: 8700 psi
  • Dimensions (W x D x H): 6-3/8 x 11-1/4 x 5-1/2 inch
Learn More
Rainin-Pressure-Module-Pressure-Module-11705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Labconco 3820000 Transfer Station

Labconco 3820000 Transfer Station

Cambridge ID #: 15513

PuriCare Open Access Station (transfer station)

Features

  • Generous work surface area to accommodate standard rodent cages
  • Electric hydraulic lift for infinite height adjustment from 36.5" to 47" with the push of a button
  • Recessed and angled sashes for closer viewing without glare
  • Large 14" high sash openings to accommodate various cage sizes with brakes
  • Large 5" diameter, non-marking polyurethane casters
  • Two 99.99% efficient HEPA filters to trap allergens
  • Nominal downflow velocity of 55 fpm.
  • Economical, disposable upper and lower prefilters
  • Variable speed motor/blower and impellers
  • Particulate-free ISO Class 5 (formerly Class 100) air
  • Retractable, safety orange, top right-side mounted power cord, 28' (9 m) on 115 volt model
  • Two push/pull bars on the right hand side to facilitate transport
  • Two 32-watt fluorescent lights
  • Two easy-to-read, ADA-compliant Minihelic pressure gauges
  • ADA-compliant light and blower switches
  • ADA-compliant electrical duplex
  • Single pass airflow design with no recirculation through the enclosure helps prevent heat stress and odor build up.
  • Type 304 stainless steel dished work surface
  • Exterior is durable glacier white and slate gray epoxy-coated steel
  • Full three year warranty on parts and labor
  • ETL listed (115 volt models)
  • CE Conformity Mark (230 volt models)
Learn More
Labconco-3820000-Transfer-Station-15513
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Flow Sciences FS 10550 M Transfer StationImage Coming Soon

Flow Sciences FS 10550 M Transfer Station

Cambridge ID #: 6252

Description:

In the 10050 Series of Bulk Powder Chemical Transfer Stations, the HEPA filtration system is housed on top of the acrylic enclosure. This filtering configuration provides maximum containment while minimizing space and energy demands. The turbulence free airflow provides a stable working environment that prevents balance fluctuations. The base of the unit is roomy enough for larger balances and comes with a standard 20” (50.8 cm) diameter cutout in the base to accommodate a large drum. Multiple filtering options are available including HEPA with 99.99% efficiency. Each system comes equipped with a face velocity alarm to continuously monitor airflow.

Specifications:

  • Dimensions (W x D x H): 59.75” x 30” x 30” (151.8 x 76.2 x 76.2 cm)
  • Weight: 305 lbs. (138.4 kg)
Learn More
Flow-Sciences-FS-10550-M-Transfer-Station-6252
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sandpiper S05B2P1TPNS000 Transfer PumpImage Coming Soon

Sandpiper S05B2P1TPNS000 Transfer Pump

Cambridge Scientific ID #'s: 11691, 11690
  • Non-Metallic Transfer Pump
  • Maximum GPM: 14.00
  • Maximum PSI: 100.00
  • Air Inlet Size (Inch): 1/4
  • Maximum Solid Size (Inch): 1/8
  • Housing Type: Polypropylene
  • Maximum Temperature: 150°F
  • Learn More
    Sandpiper-S05B2P1TPNS000-Transfer-Pump-11691
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Bio-Rad Trans-Blot SD  Semi-Dry Transfer Cell

    Bio-Rad Trans-Blot SD Semi-Dry Transfer Cell

    Cambridge Scientific ID #'s: 16546, 10519, 16545, 12365

    Features and Benefits

     

    • Transfers take place in as little as 15–60 min
    • Minimal buffer requirements save money
    • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
    • Single-step locking system allows simple, speedy setup
    • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
    • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
    • Safety cover breaks the electrical current when lifted, preventing electrical shock

     

    Applications and Uses

     

    • Western blotting
    • Nucleic acid transfer
    • Northern and Southern blot transfers in 10–35 min
    • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

     

    Features:

     

    • Maximum gel size (W x L), cm: 24 x 16
    • Buffer requirement, ml: 200
    • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
    • Recommended power supply: PowerPac HC (High Current)
    • Dimensions (W x L x H), cm: 37 x 24 x 11
    • Weight, kg/lb: 3.6/7.9
    Learn More
    Bio-Rad-Trans-Blot-SD-Semi-Dry-Transfer-Cell-16546
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

    Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

    Cambridge ID #: 17884

    Features and Benefits

     

    • Transfers take place in as little as 15–60 min
    • Minimal buffer requirements save money
    • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
    • Single-step locking system allows simple, speedy setup
    • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
    • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
    • Safety cover breaks the electrical current when lifted, preventing electrical shock

     

    Applications and Uses

     

    • Western blotting
    • Nucleic acid transfer
    • Northern and Southern blot transfers in 10–35 min
    • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

     

    Features:

     

    • Maximum gel size (W x L), cm: 24 x 16
    • Buffer requirement, ml: 200
    • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
    • Recommended power supply: PowerPac HC (High Current)
    • Dimensions (W x L x H), cm: 37 x 24 x 11
    • Weight, kg/lb: 3.6/7.9
    Learn More
    Bio-Rad-Trans-Blot-SD-Cell-Semi-Dry-Transfer-Cell-17884
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1323A HPLC Communication Module

    Agilent 1100 Series - G1323A HPLC Communication Module

    Cambridge Scientific ID #'s: 6836, 16044, 9537

    Features:

    Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

    • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
    • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
    • Protect your method from any inadvertent keyboard changes by setting method protection.
    • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
    • Monitor all operations and error events using the self-updating logbooks.
    • Use the context-sensitive online information system to get further information on all topics.
    • Use the context-sensitive menu function to have the quickest access on related functions.
    • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
    • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
    • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
    • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

     

    Learn More
    Agilent-1100-Series---G1323A-HPLC-Communication-Module-6836
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1323B HPLC Communication Module

    Agilent 1100 Series - G1323B HPLC Communication Module

    Cambridge Scientific ID #'s: 16043, 15085

    Features:

    Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

    • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
    • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
    • Protect your method from any inadvertent keyboard changes by setting method protection.
    • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
    • Monitor all operations and error events using the self-updating logbooks.
    • Use the context-sensitive online information system to get further information on all topics.
    • Use the context-sensitive menu function to have the quickest access on related functions.
    • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
    • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
    • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
    • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

     

    Learn More
    Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1100 Series - G2258A HPLC Manometric ModuleImage Coming Soon

    Agilent 1100 Series - G2258A HPLC Manometric Module

    Cambridge ID #: 18568

    The Agilent 1200 Series Dual Loop Autosampler is a fixed loop sampler with two different sample loops. As a consequence of this design the metering device, also referred to as syringe, is not a part of the solvent flow path from pump to HPLC column. An additional flush solvent bottle is used to rinse this part of the hydraulic path after each injection. In order to minimize carryover, the sampler is equipped with a needle wash function which dips the needle into a wash vial or the wash port. The wash port is fed by a peristaltic pump and can be operated with most common HPLC solvents.

     

    Specification:

     

    • Weight: 14 kg (29.8 lbs)
    • Dimensions (H x W x D): 200 x 345 x 440 mm (8 x 13.5 x 17 in.)
    • Line voltage: 100 - 240 VAC, ±10 % (wide-ranging capability)
    • Line frequency: 50 or 60 Hz, ±5 %
    • Power consumption (apparent power): 200 VA
    • Power consumption (active power): 180 W
    • Ambient operating temperature:  4 - 55 °C (41 - 131 °F)
    • Ambient non-operating temperature: -40 - 70 °C (-4 - 158 °F)
    • Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F) non condensing
    • Operating altitude: up to 2000 meters (6500 ft)
    • Non-operating temperature: top to 4600 meters (14950 ft)
    • Safety standards (IEC, CSA, UL): Installation category II, pollution degree 2
    Learn More
    Agilent-1100-Series---G2258A-HPLC-Manometric-Module-18568
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G4208A HPLC Communication Module

    Agilent 1200 Series - G4208A HPLC Communication Module

    Cambridge ID #: 19260

    Agilent 1200 Series - G4208A

     

    The Instant Pilot provides complete local control and monitoring of a single module or an entire Agilent 1100/1200/1260 and 1290 Series HPLC system. There is no data evaluation in the Instant Pilot. The Instant Pilot allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses and basic diagnostics and maintenance.

     

    Specifications:

     

    • Dimensions (W x D x H): 130 × 225 × 35 mm (5.1 × 8.9 × 1.4 inches)
    • Weight: 0.8 kg (1.76 lbs)
    • Line Voltage: 22 VDC, ± 10 %
    • Power Consumption: 7 W
    • Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
    • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
    • Humidity: < 95%, at 25 – 40 °C (77 – 104 °F)
    • Operating Altitude: Up to 3000 m (9842 ft)
    • Non-Operating Altitude: Up to 4600 m (15092 ft)
    Learn More
    Agilent-1200-Series---G4208A-HPLC-Communication-Module-19260
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G4208A Gameboy HPLC Communication Module

    Agilent 1200 Series - G4208A Gameboy HPLC Communication Module

    Cambridge ID #: 10777

    Bigger, Brighter and in Color

    The Agilent 1200 Infinity Series Instant Pilot controller gives you complete control, system monitoring, signal plotting and diagnostic capabilities for a virtually unlimited number of LC system modules. Based on the successful implementation of the industry-standard control area network (CAN) and cabling, used in the first Agilent control module, the Agilent 1200 Infinity Series Instant Pilot is even more powerful.

    Features:

    • Complete local control and monitoring of an Agilent 1200 Series, 1260 Infinity
    • and 1290 Infinity system or a single module from a single point. However, not for
    • Agilent 1220 Compact LC.
    • Mixed system configurations supported, e.g. 1200 Series, 1200 Series SL- and
    • 1100 Series.
    • Excellent readability and usability by large colored display with background light,
    • high resolution and contrast.
    • Convenient, ergonomic operation either handheld or at the stack with newly
    • developed, secure attachment.
    • Handheld or attached to a module in a stack to facilitate operator preferences.
    • Easy automation – recalibration intervals and multi-method sequences satisfy
    • the most stringent automation routines.
    • Transfer and archiving of methods, sequences and logbooks via standard USB
    • memory sticks.
    • Factory installed software – flat dialog structure, user configurable interface,
    • enhanced sequence engine, for example with wait for baseline stabilization,
    • diagnosis with passed/failed.
    • GLP – System logbook and module log-books record errors, unusual events and
    • maintenance activities for GLP traceability
    Learn More
    Agilent-1200-Series---G4208A-Gameboy-HPLC-Communication-Module-10777
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters Column Heater Module. HPLC Column Compartment / HeaterImage Coming Soon

    Waters Column Heater Module. HPLC Column Compartment / Heater

    Cambridge ID #: 7394

    Column Heater for Waters Alliance Series

    Specifications:

    • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
    Learn More
    Waters-Column-Heater-Module.-HPLC-Column-Compartment---Heater-7394
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Pharmacia LCC-501 Plus HPLC Communication ModuleImage Coming Soon

    Pharmacia LCC-501 Plus HPLC Communication Module

    Cambridge ID #: 7933

    Powerful multifunctional control unit for chromatography systems. Programmable memory allows control of chromatographic procedures, modifications of separation parameters, performance of multidimensional chromatography, as well as evaluation and print out of the chromatogram data.

    Specifications:

     

    • Temperature Range: 4 to 40 °C
    • Memory capacity: 50 Methods
    • Dimensions: 16 L x 12 W x 4.7 H (in)

     

    Learn More
    Pharmacia-LCC-501-Plus-HPLC-Communication-Module-7933
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Shimadzu Prominence CBM-20A HPLC Communication Module

    Shimadzu Prominence CBM-20A HPLC Communication Module

    Cambridge ID #: 18631

    Description:

    System controller equipped with a data buffering function and acts as an interface for connecting LC workstations, network-client computers, and analytical instruments via Ethernet. Up to eight units can be connected to the box-type CBM-20A. The card-type CBM-20Alite is used by incorporating it into an LC-20A-Series solvent delivery pump or auto-sampler. It can control up to five units, including the unit in which it is incorporated.

     

    Specifications:

     

    Connectable Units:

    Solvent delivery units: 4 max
    Autosamplers: 1
    Column ovens: 1
    Detectors: 2 max
    Fraction collectors: 1
    Sub-controllers: 2 max."
    Number of connectable units: 8 (expansion possible up to 12)
    Data Buffering: Approx. 24 hours for one analysis (at 500 ms sampling rate; available only with LCsolution)
    Event I/O: 4 inputs, 4 outputs
    Analog Boards: Up to 2 boards can be mounted
    Operating temperature range: 4°C to 35°C
    Dimensions, weight: 260 (W) x 140 (H) x 420 (D) mm, 5.5 kg
    Power requirements: 100 VAC, 100VA, 50/60HZ

    Learn More
    Shimadzu-Prominence-CBM-20A-HPLC-Communication-Module-18631
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping