We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Uv Detector: 31-45 of 197

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1311A HPLC Quaternary Pump

Agilent 1100 Series - G1311A HPLC Quaternary Pump

Cambridge Scientific ID #'s: 9165, 22111, 14496, 21293

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-9165
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

Hewlett Packard 1100 Series - G1311A HPLC Quaternary Pump

Cambridge ID #: 22470

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Hewlett-Packard-1100-Series---G1311A-HPLC-Quaternary-Pump-22470
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1311B HPLC Quaternary Pump

Agilent 1100 Series - G1311B HPLC Quaternary Pump

Cambridge ID #: 19933

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

 

Specifications:

  • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
  • Flow Range: 0.2 – 10.0 ml/min
  • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Learn More
Agilent-1100-Series---G1311B-HPLC-Quaternary-Pump-19933
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1312A HPLC Binary Pump

Agilent 1100 Series - G1312A HPLC Binary Pump

Cambridge Scientific ID #'s: 15626, 16317, 15936, 16119, 19156, 16034, 13406, 23208, 12452

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cambridge ID #: 11053

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge ID #: 16066

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-16066
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1316A HPLC Column Compartment

Agilent 1100 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 14782, 14774, 13993, 22473, 14783, 15133, 17963, 13800, 19167, 14767, 22475

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment-14782
By clicking below we can further assist you with your inquiry. Inquire 11 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1316A HPLC Column Compartment

Hewlett Packard 1100 Series - G1316A HPLC Column Compartment

Cambridge ID #: 22333

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Hewlett-Packard-1100-Series---G1316A-HPLC-Column-Compartment-22333
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1322A HPLC Degasser

Agilent 1100 Series - G1322A HPLC Degasser

Cambridge ID #: 15628

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1100-Series---G1322A-HPLC-Degasser-15628
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1323A HPLC Communication Module

Agilent 1100 Series - G1323A HPLC Communication Module

Cambridge Scientific ID #'s: 6836, 16044, 9537

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323A-HPLC-Communication-Module-6836
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1323B HPLC Communication Module

Agilent 1100 Series - G1323B HPLC Communication Module

Cambridge Scientific ID #'s: 16043, 15085

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 23206, 19935, 17476, 17331

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-23206
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 22474, 14777, 15508, 15356, 15353, 17335, 16030, 15999, 15289

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22474
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 22471, 22466

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Hewlett-Packard-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22471
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 17699, 16315, 22332, 22112, 16338, 24125, 23205, 17972

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699