Used Lab Equipment

Used Lab Equipment

Imager: 1-15 of 27

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Alpha Innotech Alpha Imager HP Gel Imaging System

Alpha Innotech Alpha Imager HP Gel Imaging System

Cambridge ID #: 16296

High-performance, fully automated imaging has made the AlphaImager HP our most popular platform. The system's application versatility not only includes a wide range of fluorescent and colorimetric applications, but can also be expanded to chemiluminescence as laboratory needs change.

Specifications:

  • Camera Resolution: 4 megapixels
  • A/D: 12-bit
  • Lens: 8 – 48 mm, f/1.2 Zoom, motorized
  • Maximum Field of View: 42 x 31 cm
  • Filter Positions: 5, motorized
  • Size: 15 x 20 x 24 in
  • Weight: 80 lbs
Learn More
Alpha-Innotech-Alpha-Imager-HP-Gel-Imaging-System-16296
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Alpha Innotech Alpha Imager Mini Gel Imaging SystemImage Coming Soon

Alpha Innotech Alpha Imager Mini Gel Imaging System

Cambridge ID #: 24331
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Alpha-Innotech-Alpha-Imager-Mini-Gel-Imaging-System-24331
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Invitrogen M7000 Imager

Invitrogen M7000 Imager

Cambridge ID #: 25726

The EVOS M7000 Imaging System is a high-performance, fully automated, inverted, multi-channel fluorescence and transmitted light imaging system. It was developed to meet today’s expectations for image quality, user interface interactions, data generation speed and flexibility, and end-user value. The powerful and time-saving acquisition tools with enhanced autofocus algorithms and automated routines for microwell plate assays, time-lapse live cell imaging, area scanning in time lapse and Z-stacks in scan mode, and a superb optomechanical design enable the generation of publication-quality images and data with just a few clicks when and where needed.

Specifications:

Includes: Evos M7000 Monitor, Evos M7000 Microscope, Evos M7000 Computer,  

Camera: 3.2 Megapixels, Color, CMOS (2 cameras)

Model: M7000

Light Source: LED

Magnification: 1.25X to 100X

Objectives: 5 Position Turret

Resolution: 1920 x 1080 pixels

Display: LCD

Shipping Condition: Room Temperature

Learn More
Invitrogen-M7000-Imager-25726
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Dynamics Typhoon 9410 Variable Mode Imager System

Molecular Dynamics Typhoon 9410 Variable Mode Imager System

Cambridge ID #: 14615

 

Includes:

  • Blue Laser Module
  • Laptop w/ Image Quant and Scan Control Software loaded on computer
  • All Necessary Cables, Cords and Manuals

Features:

  • Versatile system platform, handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.
  • Provides optimized detection of Cy2, Cy3, and Cy5 CyDye DIGE Fluor minimal and saturation dyes, enabling visualization of up to three differently labeled samples on a single gel.
  • Exceptional signal-to-noise increases the number of statistically significant differences detected.
  • Consistent point-light illumination produces high-quality uniform images and reduces photo-bleaching.
  • Gels are scanned between glass plates, preventing drying and shrinkage and allowing further running and rescanning if required.
Learn More
Molecular-Dynamics-Typhoon-9410-Variable-Mode-Imager-System-14615
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare Typhoon Trio Variable Mode Imager System

GE Healthcare Typhoon Trio Variable Mode Imager System

Cambridge ID #: 14509

The Typhoon instrument is a variable-mode imager that produces digital images of radioactive, fluorescent, or chemiluminescent samples. The Typhoon instrument is available in several models. The Typhoon Trio instrument contains three internal lasers (blue, green, and red).

 

Includes:

 

  • Red, Blue, Green Laser Modules Built in
  • Image Quant and Scan Control Software loaded on computer
  • All Necessary Cables, Cords and Manuals

 

For DNA, RNA, and protein samples, users can choose from:

  • Storage phosphor autoradiography
  • Direct green (532 nm) excited fluorescence
  • Direct red (633 nm) excited fluorescence
  • Direct blue (488 nm) excited fluorescence
  • Chemiluminescence

 

Features:

  • When one of the five scanning modes is selected, the appropriate optical components are automatically activated.
  • Typhoon imagers scan mounted and unmounted storage phosphor screens, gels and blots up to 35 x 43 cm as well as microarrays.
  • Typhoon imagers exhibit outstanding linearity and quantitative  accuracy, and include ImageQuant TL Image Analysis Software.
  • Typhoon imagers are fully optimized as part of the Ettan DIGE system, and seamless integration with DeCyder Differential Analysis Software
  • is ensured for all models.
  • Special tray templates that are part of the latest scanner control software and new optional Gel Alignment Guides add higher throughput and ease of handling 2-D gels run on Ettan DALT and SE600.

 

Learn More
GE-Healthcare-Typhoon-Trio-Variable-Mode-Imager-System-14509
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare Typhoon Trio plus Variable Mode Imager System

GE Healthcare Typhoon Trio plus Variable Mode Imager System

Cambridge ID #: 20645

The Typhoon instrument is a variable-mode imager that produces digital images of radioactive, fluorescent, or chemiluminescent samples. The Typhoon instrument is available in several models. The Typhoon Trio instrument contains three internal lasers (blue, green, and red).

 

Includes:

 

  • Red, Blue, Green Laser Modules Built in
  • Image Quant and Scan Control Software loaded on computer
  • All Necessary Cables, Cords and Manuals

 

For DNA, RNA, and protein samples, users can choose from:

  • Storage phosphor autoradiography
  • Direct green (532 nm) excited fluorescence
  • Direct red (633 nm) excited fluorescence
  • Direct blue (488 nm) excited fluorescence
  • Chemiluminescence

 

Features:

  • When one of the five scanning modes is selected, the appropriate optical components are automatically activated.
  • Typhoon imagers scan mounted and unmounted storage phosphor screens, gels and blots up to 35 x 43 cm as well as microarrays.
  • Typhoon imagers exhibit outstanding linearity and quantitative  accuracy, and include ImageQuant TL Image Analysis Software.
  • Typhoon imagers are fully optimized as part of the Ettan DIGE system, and seamless integration with DeCyder Differential Analysis Software
  • is ensured for all models.
  • Special tray templates that are part of the latest scanner control software and new optional Gel Alignment Guides add higher throughput and ease of handling 2-D gels run on Ettan DALT and SE600.

 

Learn More
GE-Healthcare-Typhoon-Trio-plus-Variable-Mode-Imager-System-20645
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Zeiss AxioImager M1 Compound Microscope

Zeiss AxioImager M1 Compound Microscope

Cambridge ID #: 18577

Features:

  • Zeiss Axio Imager M1 Trinocular Frame
  • Ergonomic Adjustable Height EyePieces
  • LCD Side Screen
  • (2) Carl Zeiss W-PI 10x/23 455043-0000 EyePieces
  • 6 Position Fluorescence Illuminator
  • Trinocular Head
  • Motorized Stage
  • Zeiss Power Supply 231
  • 100mg Fluorescent light w/ power supply OR Xcite 120Q Metal Halide OR Xcite 120LED Mini or Boost
  • Objectives
    • EC Plan NEOFLUAR
    • EC Plan NEOFLUAR 2.5x/0.075
    • Plan APOCHROMAT 5x/0.16
    • Plan APOCHROMAT 10x/0.45
    • Plan APOCHROMAT 20x/0.8
    • Plan APOCHROMAT 40x/0.95 korr
Learn More
Zeiss-AxioImager-M1-Compound-Microscope-18577
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Zeiss AxioImager Z1 Inverted Phase Contrast Microscope

Zeiss AxioImager Z1 Inverted Phase Contrast Microscope

Cambridge ID #: 18463

Specification:

 

  • Eyepiece: Pl 10x / 25
  • Dimensions (W x D x H): Axio Imager stand, manual with HBO 100 - approx. 300 mm x 721 mm x 505 mm
  • Weight: approx. 18 to 30 kg dependent on equipment and accessories

 

  • Storage condition

 

    • Permissible ambient temperature: +10 to +40°C
    • Permissible relative humidity (no condensation): max. 75% at 35 °C

 

  • Operation

 

    • Permissible ambient temperature: +10 to +40°C
    • Permissible relative humidity (no condensation): max. 75% at 35 °C
    • Atmospheric pressure: 800 hPa to 1060 hPa
    • Altitude: Max. 2000 m
    • Pollution degree: 2
    • Operating environment: Closed room
    • Protection class: I
    • Protection type: IP 20
Learn More
Zeiss-AxioImager-Z1-Inverted-Phase-Contrast-Microscope-18463
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad ChemiDoc XRS Gel Imaging System

Bio-Rad ChemiDoc XRS Gel Imaging System

Cambridge Scientific ID #'s: 25407, 25369

Includes Computer loaded w/ Image Lab Software

 

The ChemiDoc MP system is a full-feature instrument for gel or western blot imaging. It is designed to address multiplex fluorescent western blotting, chemiluminescence detection, and general gel documentation applications.

Its features are based on CCD high-resolution, high-sensitivity detection technology, and modular options to accommodate a wide range of samples and support multiple detection methods. The system is controlled by Image Lab software to optimize performance for fast, integrated, and automated image capture and analysis of various samples.

 

Features and Benefits

  • Multiple imaging capabilities — the ChemiDoc MP imager can accommodate a variety of sample types and detection methods including multiplex fluorescent western blotting. It is the perfect imager to accompany your protein and DNA electrophoresis runs as well as your western blotting experiments. It delivers quantitative, reproducible results for fluorescence, chemiluminescence, and colorimetric detection
  • Stain-free technology — UV-induced fluorescence labeling of proteins in the stain-free gels allows a 2 hr Coomassie gel-staining protocol to be condensed into a 5 min stain-and-image step. Stain-free gels are western blot compatible — using the V3 Western Workflow™, check your electrophoresis results and blot transfer quality prior to western blotting
  • High-sensitivity blot detection — the ChemiDoc MP imaging system offers advanced detection technology that determines optimal exposure, even for faint or intense samples. Superior sensitivity is achieved for chemiluminescence and multiplex fluorescence detection and for colorimetric gel and blot documentation
  • Superior Image Quality — exceptional dynamic range enables visualization of faint and intense bands on same blot or gel. Images are always in focus at any zoom level to ensure publication-ready images in seconds
  • Ease of Use — precalibrated system provides the precise focus for any zoom setting or sample height; automated hands-free operation ensures consistent, reproducible, and high-throughput performance

 

Applications     

  • Chemiluminescence: Yes
  • Fluorescence: Yes
  • Colorimetry/densitometry: Yes
  • Gel documentation:Yes

Hardware Specifications        

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 26 x 35 cm
  • Maximum image area: (For standard UV-excited gels) 25 x 26 cm
  • Excitation source: Epi-white light and trans-UV (302 nm) are standard (optional 365 nm lamp available); optional trans-white conversion screen, XcitaBlue™ conversion screen, and epi-red, epi-green, and epi-blue LED modules available
  • Illumination control: 8 modes available. Trans-UV, epi-white, and no illumination for chemiluminescence are standard; epi-red, epi-green, epi-blue, trans-white, and XcitaBlue conversion screens are optional
  • Detector: Supercooled CCD
  • Image resolution: 4 megapixels
  • Pixel size (H x V): 6.45 x 6.45 µm
  • Cooling system: Peltier
  • Camera cooling temperature: -30°C absolute and regulated
  • Filter holder: 6 positions (5 for filters, 1 without filter for chemiluminescence)
  • Emission filters: 1 included (standard), 4 optional
  • Dynamic range: >4.0 orders of magnitude
  • Pixel density (gray levels): 65,535
  • Dynamic flat fielding: Application specific; for all applications
  • Instrument size (L x W x H): 36 x 60 x 96 cm
  • Instrument weight: 32 kg

Operating Ranges       

  • Operating voltage: 110/115/230 VAC nominal
  • Operating temperature: 10–28°C (21°C recommended)
  • Operating humidity, noncondensing: <70%

Automation Capabilities         

  • Workflow automated selection: Application driven; user selected or recalled by a protocol
  • Workflow automated execution: Controlled by a protocol via application-specific setup for image area, illumination source, filter, analysis, and reporting
  • Workflow reproducibility: 100% repeatability via recallable protocols; from image capture to quantitative analysis and reports
  • Autofocus (patent pending): Precalibrated focus for any zoom setting or sample height
  • Image flat fielding**: Dynamic; precalibrated and optimizor every application
  • Autoexposure: 2 user-defined modes (intense or faint bands)
Learn More
Bio-Rad-ChemiDoc-XRS-Gel-Imaging-System-25407
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Fisher Scientific FBTIV-88 TransilluminatorImage Coming Soon

Fisher Scientific FBTIV-88 Transilluminator

Cambridge ID #: 26066
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Fisher-Scientific-FBTIV-88-Transilluminator-26066
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 FluorChem SP Gel Imaging SystemImage Coming Soon

FluorChem SP Gel Imaging System

Cambridge Scientific ID #'s: 23904, 26316

Features: 

 

Features for the Photometrics Cool SNAP K4: 

  • 20-MHz readout: High-speed, high-sensitivity image capture
  • 2048 x 2048 imaging array: Resolves fine detail
  • 7.4 x 7.4-ìm pixels: Ideally matched to optical microscope
  • Interline-transfer, progressive-scan CCD: Eliminates camera vibration and facilitates fast triggering
  • Flexible binning and readout: Increases light sensitivity while increasing the frame rate
  • 12-bit digitization: Quantifies bright and dim signals in the same image
  • Thermoelectric cooling: Long integration times for higher sensitivity
  • Enhanced quantum efficiency: Provides higher sensitivity than typical interline cameras
  • C-mount: Easily attaches to microscopes, standard lenses, or optical equipment
  • Acquisition software: Captures, analyzes, and saves high-resolution images
  • PCI interface: High-bandwidth, uninterrupted data transfer
  • PVCam, Circular buffers, Device sequencing: Supported by numerous third-party software packages, Real-time focus, Precise integration with shutters, filter wheels, etc. (Compatible with Windows XP/Vista 32, Mac OS X, and Linux (kernel versions 2.4 and 2.6.8))
  • CCD image sensor: Kodak KAI-4020M; interline-transfer, progressive-scan device with microlenses
  • CCD format: 2048 x 2048 imaging array, 7.4 x 7.4-um pixels, 15.16 x 15.16-mm imaging area (optically centered)
  • Linear full well: 30,000 e- (single pixel); 60,000 e- (2 x 2 binned pixel)
  • Read noise: ≤10 e- rms @ 20 MHz
  • Nonlinearity: <1%
  • Digitizer type: 12 bits @ 20 MHz
  • CCD temperature: -25ͦC (regulated)
  • Dark current : 0.1 e-/p/s @ -25ͦC
  • Operating environment: 0 to 30ͦC ambient, 0 to 80% relative humidity noncondensing
  • I/O TTL (trigger/status): trigger, invert, inhibit, exposing, interline shift, frame readout, 8-bit TTL (programmable), 8-bit DACs(two)

Compare this against “Features of Gel Doc XRS+ system”: 

  • Chemiluminescence: Yes
  • Fluorescence: Yes
  • Colorimetry/densitometry: Yes
  • Gel documentation: Yes  

Hardware Specifications        

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 26X 35 cm
  • Excitation source: Trans-UV and epi-white are standard (302 nm included, with 254 and 365 nm available as options)
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: super cooled CCD
  • Image resolution: 4 megapixels
  • Pixel size (H x V): 6.45 x 6.45 µm
  • Filter holder: 3 positions (2 for filters, 1 without filter)
  • Emission filters: 1 included (standard), 3 optional
  • Dynamic range: >4.0 orders of magnitude
  • Pixel density (gray levels): 65,535
  • Dynamic flat fielding: Application specific, for all applications
  • Instrument size (L x W x H): 36 x 60 x 96 cm
  • Instrument weight: 32 kg

 Operating Ranges         

  • Operating voltage: 110/115/230 V AC nominal
  • Operating temperature: 10–28°C (21°C recommended)
  • Operating humidity: <70% noncondensing

 Automation Capabilities            

  • Workflow automated selection: Application driven; user selected or recalled by a protocol
  • Workflow automated execution: Controlled by a protocol via application specific setup for image area, illumination source, filter, analysis, and reporting
  • Workflow reproducibility: 100% repeatability via recallable protocols; from image capture to quantitative analysis and reports
  • Autofocus: Precalibrated focus for any zoom setting or sample height
  • Image flat fielding: Dynamic; precalibrated and optimized per application
  • Autoexposure: 2 user-defined modes (intense or faint bands)
Learn More
-FluorChem-SP-Gel-Imaging-System-23904
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad GelDoc EZ Gel Imaging SystemImage Coming Soon

Bio-Rad GelDoc EZ Gel Imaging System

Cambridge ID #: 24279
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Bio-Rad-GelDoc-EZ-Gel-Imaging-System-24279
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Syngene Gene Flash Gel Imaging System

Syngene Gene Flash Gel Imaging System

Cambridge ID #: 22982
  • Syngene GeneFlash Network Bio Imaging System
  • Learn More
    Syngene-Gene-Flash-Gel-Imaging-System-22982
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Thermo Cellomics CellInsight Gel Imaging System

    Thermo Cellomics CellInsight Gel Imaging System

    Cambridge ID #: 10067

    Description:

    High-content screening (HCS) or high-content analysis (HCA) requires an instrument designed to extract the maximum information from your sample in a robust and reproducible manner with the speed for high-throughput analysis. The entire Thermo Scientific portfolio of HCA instruments helps deliver on those parameters and includes:

    • Superior illumination—the LED light engine reduces intensity fluctuations and optical component wear, eliminates moving parts, and reduces both integration and channel switching times
    • Rapid data analysis—Thermo Scientific HCS Studio software analyzes your images in real time, so that you collect all the data you need to make decisions that count
    • Reagent compatibility—Thermo Scientific HCS platforms build on the expertise of Molecular Probes in reagent development with exquisite fluorescent tools for interrogating the biology of the cell

    Specifications:

    • Camera: Photometrics X1 Camera with 4.54um/pixel
    • Live cell: Optional HCA On-Stage Incubator with Kinetic scheduling of acquisition
    • Software: HCA Studio 3.1 Cell Analysis Software. Optional client software available
    • Database: STORE Express Image and Database Management Software Included, Scalable SQL/Oracle database options available
    Learn More
    Thermo-Cellomics-CellInsight-Gel-Imaging-System-10067
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Syngene Chemi Genius Gel Imaging System

    Syngene Chemi Genius Gel Imaging System

    Cambridge ID #: 20230

    Features:

     

    Chemi Genius 2 Bio Imaging System

     

    Specifications:

    • Hamamatsu C4742-80-12AG ORCA-ER Camera Controller

     

    • Hermetic Vacuum Sealed Head
    • High Resolution of 1.37 Million Pixels
    • Exposure Time up to 10 Seconds
    • Progressive Scan Interline CCD Chip with No Mechanical Shutter
    • Binning Function

     



    Learn More
    Syngene-Chemi-Genius-Gel-Imaging-System-20230
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping