Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Laser Detection Bioassay System: 16-30 of 601

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1290 Infinity Binary UPLC Stack HPLC System

Agilent 1290 Infinity Binary UPLC Stack HPLC System

Cambridge ID #: 20004

The Agilent 1290 Infinity Binary LC is not only the most powerful but also the most adaptive UHPLC system available. No matter what your laboratory requires, the 1290 Infinity Binary LC can handle the widest range of applications; UHPLC methods, legacy HPLC methods, HPLC-to-UHPLC method transfer, method development, multi-compound screening, LC/MS coupling, and many more.

 

Features:

  • Most adaptive  – emulates other HPLC and UPLC systems, connects to all Agilent and many non-Agilent software
  • Highest performance & flexibility – by any measure
  • HPLC-like service costs – UHPLC productivity

 

Includes:

  • G1316C TTC Column Compartment
  • G4226A Autosampler
  • G1330B Autosampler Thermostat
  • G4220A Binary pump
  • Tray
  • 1200 Instant Pilot
Learn More
Agilent-1290-Infinity-Binary-UPLC-Stack-HPLC-System-20004
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 2790 HPLC SystemImage Coming Soon

Waters 2790 HPLC System

Cambridge Scientific ID #'s: 7451, 5935, 14240

Description - The Waters 2790 features a large, easy-to-use LCD interface. Scientists can take advantage of the quick autostart and optimize their methods with a simple push of a button. Manage microplates with the built in autosampler. This reliable tool is a common work-horse in most analytical and contract labs. Built to meet labs rigorous requirements or routine analysis, this robust instrument is easily found in Pharmaceutical, Food Safety, R&D, Chemistry, Environmental or Quality Control labs. Simplify how you collect data, built-in compliance and validation features. The Empower software is capable of automating method development, archiving methods and customizing data reports.

 

Optional Detectors:

  • 996 PDA Detector:
  • 2996  PDA Detector:
  • 2998 PDA Detector:
  • 2487 UV detector:
  • 2489 UV Detector:
  • 2475 FLD detector:
  • Waters 2410 Refractive Index Detector:

 

The components can be customized to your needs.

Learn More
Waters-2790-HPLC-System-7451
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Waters 3100 Mass Detector Autopurification System

Waters 3100 Mass Detector Autopurification System

Cambridge ID #: 19717

Waters Autopurification System Includes:

  • 3100 Mass Detector
  • 1525 Binary HPLC Pump (0-22.5 mL/min)
  • System Fluidics Organizer (SFO)
  • 515 Make-up Pump
  • 2489 UV/Vis Detector
  • 2767 Sample Manager
  • Sogevac SV40 BI Vacuum Pump
  • PC with MassLynx 4.1
Learn More
Waters-3100-Mass-Detector-Autopurification-System-19717
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Applied Biosystems 4800 Maldi TOF MS System

Applied Biosystems 4800 Maldi TOF MS System

Cambridge ID #: 10114

Includes Computer Loaded with 4000 Series Explorer Software Version 3.5.

 

The 4800 MALDI TOF/TOF Analyzer is a next-generation tandem time-of-flight MS/MS system that gives you all the advantages of MALDI in a flexible, easy-to-use, ultra-high-performance mass spectrometer.

  • OptiBeam™ on-axis laser provides ten times greater sensitivity to identify and quantitate low-abundance proteins in complex biological samples.
  • High-resolution precursor ion selection, enabled by the QuanTIS precursor selector, lets you detect and identify peptides that other systems miss and makes it easier for you to interpret your data by simplifying MS/MS spectra.
  • Ideal solution for high sensitivity putative protein biomarker identification and quantitation.
  • Fully supports LC MALDI workflows, allowing you to mass analyze without the time constraints of LC.
  • Simple experiment setup and fast mass analysis maximizes laboratory productivity.
  • High-energy, information-rich fragmentation patterns unavailable on other instrument platforms enable you to analyze carbohydrates, lipids, and other biological components.

Identify and Quantitate Putative Protein Biomarkers with Confidence
The 4800 MALDI TOF/TOF analyzer offers a new level of sensitivity for identifying and quantifying low abundance putative protein biomarkers. Fully compatible with novel iTRAQ™ reagents, the 4800 analyzer provides the most direct path to protein biomarker discovery. An expanded dynamic range enables high confidence identification and quantitation of low-level putative protein biomarkers in complex matrices. Powerful, easy-to-use GPS Explorer™ provides simplified, automated workflows to get you more quickly from discovery to validation.

The Only MALDI TOF/TOF™ Analyzer with On-Axis Laser Irradiation
The 4800 Analyzer is the only MALDI TOF/TOF mass spectrometer with on-axis laser irradiation, enabling sensitivity in the attamole range. Proprietary source modeling algorithms enable low ppm mass detection across the MALDI plate.

Expand Workflows, Increase Throughput
Get the speed, stability, and reliability you need to expand your current experimental workflows and add statistical significance to your experimental results. Quickly and easily increase throughput using automation features that allow you to rapidly and confidently collect the MS/MS spectra that really matter —and not waste valuable resources acquiring and evaluating those that don't.

Learn More
Applied-Biosystems-4800-Maldi-TOF-MS-System-10114
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Lonza 57025 FlashGel System

Lonza 57025 FlashGel System

Cambridge ID #: 20076

Features:

 

The FlashGel System for fast electrophoresis of DNA is the ideal sample screening tool. Check up to 32 PCR or restriction fragments quickly without having to plan your day around agarose gels or verify your DNA sample integrity prior to downstream analysis. The FlashGel System is the fastest way to separate DNA and the best way to watch DNA migration as it happens. This revolutionary new tool separates DNA in 2 - 7 minutes. Monitor gel runs right at the bench, without UV light. The highly sensitive system allows a 5-20X reduction in DNA levels - saving both time and money.

 

Specifications:

 

 

  • 5 minute separation and recovery
  • See bands in as little as 2 minutes
  • Recover samples directly without UV light band excision or purification,
  • Real-time separation and documentation
  • Watch band migration as it happens
  • Photograph gels at the bench without DNA damaging UV light
  • Outstanding sensitivity and resolution

 

 

Learn More
Lonza-57025-FlashGel-System-20076
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Lonza 57040 FlashGel System

Lonza 57040 FlashGel System

Cambridge ID #: 20077

Features:

 

The FlashGel Camera captures data from the FlashGel System and say goodbye to darkrooms and UV light. Complete separation and documentation safely, at your bench, in minutes. This simple digital camera in an enclosed hood connects directly to your laptop or PC via USB cable.

 

Specifications:

 

 

  • 5 minute separation and recovery, See bands in as little as 2 minutes
  • Recover samples directly without UV light band excision or purification
  • Real-time separation and documentation
  • Watch band migration as it happens
  • Photograph gels at the bench without DNA damaging UV light
  • Outstanding sensitivity and resolution

 

 

Learn More
Lonza-57040-FlashGel-System-20077
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6420A Triple Quad LC/MS System

Agilent 6420A Triple Quad LC/MS System

Cambridge ID #: 17976

The Agilent 6420A Triple Quadrupole LC/MS System is equipped with performance specifications in Signal-to-Noise ratio and Instrument Detection Limit for routine analysis.

Specifications:

  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI positive: S/N > 6,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 2,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 60 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 60 fg
  • Mass range: m/z 5 – 2,250
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:1 Da from 5 – 1,000 m/z; 0.01% from 1,000 – 2,000 m/z; 0.02% from 2,000 – 2,250 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment, > 40,000 ion transitions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms

Features:

  • 1260 Infinity Binary Pump Clinical
  • 1260 Infinity high perfomance degasser clinical edition
  • 1260 Infinity high perfomrance autosampler clinical edition
  • PEAK Nitrogen generator system
Learn More
Agilent-6420A-Triple-Quad-LC-MS-System-17976
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6460C LC/MS System

Agilent 6460C LC/MS System

Cambridge ID #: 17703

The Agilent 6460C Triple Quadrupole LC/MS System is equipped with Agilent Jet Stream Technology to enable enhanced sensitivity. The 6460 provides a fast and robust solution to simultaneously quantify, screen, and confirm analytes in the laboratory.

  • Greater signal and reduced noise - Agilent Jet Stream technology uses super-heated nitrogen to improve ion generation and desolvation
  • Efficient analysis – fast MRM speeds allow for analysis of over 100 overlapping compounds in a given retention time window
  • Screen, confirm and quantify – Triggered MRM (tMRM) combines fast and sensitive MRM quantitation with the generation of a product ion spectrum for library searching and compound screening and confirmation
  • Fast polarity switching for analysis of both positive and negative ions

Specifications:

  • MRM sensitivity Signal-to-Noise ratio ESI positive: S/N > 30,000:1 Noise 1 × RMS
  • MRM sensitivity Signal-to-Noise ratio (S/N) ESI negative: S/N > 10,000:1 Noise 1 × RMS
  • MRM sensitivity Instrument Detection Limit (IDL) ESI positive: IDL < 12.5 fg
  • MRM sensitivity Instrument Detection Limit (IDL) ESI negative: IDL < 12.5 fg
  • Mass range: m/z 5 – 3,000
  • Polarity switching: 30 ms
  • Mass resolution (autotune):7 Da
  • Mass resolution (manual tune):5 Da
  • Mass accuracy:
    • Da from 5 – 1,000 m/z
    • 01% from 1,000 – 2,000 m/z
    • 02% from 2,000 – 3,000 m/z
  • Mass stability: < 0.1 Da in 24 h
  • Dynamic range: > 6.0 × 106
  • Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
  • Maximum scan rate: 12,500 Da/s
  • Minimum MRM dwell time: 1 ms
  • MRM transitions: 450 per time segment > 40,000 ion transactions per method
  • Dynamic MRM transitions: 4,000 ion transitions per method
  • Triggered MRM transitions: Up to 10 MRM transitions (primary and secondary) for library search and compound confirmation
  • Collision cell ion clearance: < 1 ms
Learn More
Agilent-6460C-LC-MS-System-17703
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6490 Triple Quad LC/MS System

Agilent 6490 Triple Quad LC/MS System

Cambridge ID #: 20395

Features:

The Agilent 6490 Triple Quadrupole LC/MS System incorporates iFunnel technology to give new levels of sensitivity for the most challenging quantitative analyses in pharmaceutical, clinical, food safety, and environmental applications. The quantitative power of the 6490 Triple Quadrupole is enhanced by an extended linear dynamic range.

The 6490 Triple Quadrupole LC/MS delivers:

  • 10 X increase in sensitivity
  • Up to six orders of linear dynamic range
  • Robust performance and operation
  • Zeptomole sensitivity for the most challenging applications

The 6490 triple quadrupole has a compact benchtop design, achieved through use of a curved collision cell. The newly designed cell also helps to reduce background noise, improving overall system signal-to-noise. New high frequency quadrupole electronics enable faster scan rates and allow for narrow mass window isolation.

Includes:

  • Agilent 6490 LCMS Triple Quad System
  • Agilent Varian MS40+ Vacuum Pump
  • Computer loaded with Agilent Masshunter Workstation Software
  • Monitor, Keyboard, Mouse, Cables
Learn More
Agilent-6490-Triple-Quad-LC-MS-System-20395
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Agilent 6530 QTOF with 1260 Infinity Bioinert HPLC LC/MS System

Cambridge ID #: 18290

Features:

  • Mass accuracy within 2 ppm gives you complete confidence in your analysis.
  • Powerful Agilent Jet Stream source enables you to uncover low level components.
  • Wide in-spectrum dynamic range facilitates simultaneous measurement of minor components in the presence of intense background interferences.
  • The latest developments in Agilent Infinity II UHPLC, 2D-LC, SFC, and even GC-APCI chromatographic interfaces give you blazing fast acquisition speed.
  • Powerful MassHunter software provides the latest software capabilities for profiling, characterizing, identifying, and quantifying compounds in complex mixtures via high-definition MS and MS/MS.
  • Check out the latest developments in untargeted screening and quantitation using Agilent’s All Ions MS/MS technique.

Specifications:

  • Sensitivity, MS mode, electrospray on-column, 400 µL/min flow rate: 200:1 RMS; Option 200: 60:1 RMS
  • Sensitivity, MS/MS mode, electrospray on-column, 400 µL/min flow rate: 500:1 RMS; Option 200: 180:1 RMS
  • Mass resolving power: Greater than 10,000 at 118 m/z; Greater than 20,000 FWHM at 1,522 m/z
  • Mass accuracy, MS mode, electrospray on-column, 400 µL/min: Better than 2 ppm RMS as measured from 10 repeat injections
  • Mass accuracy, MS/MS mode, electrospray on-column, 400 µL/min: Better than 3 ppm RMS on m/z 397 as measured from 10 repeat injections
  • Mass accuracy temperature stability, MS mode: Maintain 1 ppm mass accuracy (variations < 3 °C from calibration temperature)
  • Dynamic range: Up to 5 decades
  • Mass range: m/z 100 – 20,000 extended mass range m/z 50 – 1,700 or 50 – 3,200 for both high resolution and extended dynamic range modes Quadrupole up to 4,000 m/z
  • Spectral acquisition rate, MS mode: 50 spectra/second
  • Spectral acquisition rate, MS/MS mode mode: 50 MS/MS spectra/second
  • Positive to negative switching:5 seconds

Includes:

  • G5611A 1260 Quat Pump
  • G5667A 1260 HiP BioALS
  • G1316A 1260 TCC
  • G4212B 1260 DAD
  • G5664A 1260 BioFC-AS
  • Computer loaded with MassHunter BioConfirm (G829AA), Agilent SpectrumMill Proteomics (G2721AA), Mass Profiler Professional (G3835AA) and Personal METLIN metabolite database (G6825AA) software.
Learn More
Agilent-6530-QTOF-with-1260-Infinity-Bioinert-HPLC-LC-MS-System-18290
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6540A LC/ MS Q-ToF System

Agilent 6540A LC/ MS Q-ToF System

Cambridge ID #: 20099

Agilent 6540A UHD Accurate-Mass Q-ToF LC/MS with 1290 HPLC System

This unit is almost new from 2012. No samples were run except for the Agilent initial installation and routine annual PM.

Includes:

  • G6540A UHD Accurate Mass Q-TOF LC/MS. includes ultra-high definition Q-TOF, JetStream technology, MassHunter workstation. (Dual ESI for Jet Stream source)
  • G1947B LC/MS APCI Source. Includes APCI spray chamber, corona discharge needle, nebulizer, APCI vaporizer, and test calibration kit. Configuration for usage with Q-ToF
  • G4220A 1290 Infinity Binary Pump. Includes Intelligent System Emulation Technology (ISET), integrated degassing unit, solvent selection valve connecting capillaries, column, solvent cabinet, bottles, system tool-kit and CAN cable.
  • G4226A 1290 Infinity Autosampler. A 1200 bar autosampler module in Agilent's new 1290 Infinity series of LC system. It features less than 100 ul of hydraulic delay volume and low carryover with flow-through injection design.
  • G1316C 1290 Infinity Thermostatted Column Compartment For use with any 1290 Infinity or 1260 Infinity system requiring low dispersion or special valve solutions. Temperature up to 100 degree C.
  • G4232B 2pos/10 port Valve head 1200bar. Includes 1200 bar QuickChange valve head, Capillary Kit 0.12mmID, G1316C 2/10 vlv
  • G3835A Mass Profiler Professional (MPP) Software.
  • G1953A PEAK Nitrogen Generator System. N2 Generator-PEAK Model NM32LA nitrogen generator with air compressor.
Learn More
Agilent-6540A-LC--MS-Q-ToF-System-20099
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 7000C Triple Quad w/ 7890B GC/MS/MS System

Agilent 7000C Triple Quad w/ 7890B GC/MS/MS System

Cambridge ID #: 19882

The 7000C Triple Quadrupole GC/MS was designed to deliver the most accurate quantitative results and confident identification even in the most complex matrices. The 7000C GC/MS system’s 4fg OFN Instrument Detection Limit (IDL) is demonstrated upon installation verifying unmatched ALS, GC and MS performance. Coupled with the 7890B GC, the 7000C MS works in perfect harmony to enhance productivity, save resources and alert operators about pending maintenance. The MassHunter software’s new, enhanced MRM optimization tools and the Pesticides and Environmental Pollutants Database comprehensive information content provides simple yet flexible MS/MS method development.

System Includes:

  • Agilent 7000C Quadruple GC/ MS MS EI System
  • Agilent 7890B GC
  • Agilent 7693A Autoinjector
  • Agilent 7693 150 Vial Tray
  • Computer laoded with MassHunter Software
Learn More
Agilent-7000C-Triple-Quad-w--7890B-GC-MS-MS-System-19882
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity H Class Stack UPLC System

Waters Acquity H Class Stack UPLC System

Cambridge ID #: 15385

The Waters ACQUITY UPLC H-Class System delivers the flexibility of quaternary solvent blending with the advanced performance of UPLC® separations. The system's holistic design is targeted for routine analysis and method development use and is perfectly suited for running both HPLC and UPLC applications while still realizing the improved resolution and sensitivity of UPLC separations.

 

Includes:

  • TUV Detector (PDA Detector $1000 additional)
  • Sample Manager - FTN
  • Column Manager to control up to 4 Columns
  • Quaternary Solvent Manager
    • 15,000 psi up to 1.0 mL/min,
    • 9000 psi up to 2.0 mL/min
  • Computer Loaded with Empower

 

Specifications:

  • Dwell volume (total system): <400 ~L (includes standard 100 ~L mixer)
  • Integrated leak management: Leak sensors, as standard, and safe leak handling
  • Quantum synchronization: Injection synchronization between pump and sample manager enhances retention time reproducibility
  • Set table flow rate range:
    • 01 0 to 2.000 mLlmin, in 0.001 mL increments (firmware version 1.5x and earlier)
    • 010 to 2.200 mL/min, in 0.001 mL increments (firmware version 1.60)
    • 001 to 2.200 mLlmin in 0.001 mL increments (firmware version 1.65 and later)
  • Maximum operating pressure:
    • 15,000 psi up to 1.0 mL/min, 9000 psi up to 2.0 mL/min (firmware version l.5x and earlier)
    • 15,000 psi up to 1.0 mL/min, 7800 psi up to 2.2 mL/min (firmware version 1.6x and later)
  • pH range: 2 to 12
  • Unattended operation: Leak sensors and safe leak handling, full 96-hour diagnostic data display through console software
  • Cycle time: <30s Inject to Inject
Learn More
Waters-Acquity-H-Class-Stack-UPLC-System-15385
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity SQD 2 LC/MS System

Waters Acquity SQD 2 LC/MS System

Cambridge ID #: 15346

The Waters SQ Detector 2 is an advanced bench top single quadrupole mass detector designed for high performance LC/MS applications. With a wide range of ionization options including Atmospheric Pressure Photo Ionization (APPI) and the Atmospheric Solids Analysis Probe (ASAP), the SQ Detector is ideally suited to a wide range of qualitative and quantitative applications.  The system includes IntelliStart Technology, for automated system optimization and status monitoring, ensuring that the highest quality of data is routinely available to all levels of operators

 

Includes:

  • Waters SQ Detector 2 UPLC/MS Mass Spectrometer
  • Enhanced high performance single quadrupole mass spectrometer system
  • Roughing Pump
  • Windows 7 Computer loaded w/ Mass Lynx 4.1
  • Optional Acquity UPLC
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Performance Specifications:

  • Acquisition modes
    • Full scan MS
    • Selected Ion Recording (SIR)
  • Radar: An information rich acquisition approach that allows you to collect highly specific quantitative date for targer compounds while providing the ability to visualize all other components
  • Mass range: 2 to 3072 m/z
  • Scan speed: Up to 15,000 Da/s
  • Examples of achievable acquisition rates:
    • 15 scans per second (m/z 100 to 1000)
    • 30 scans per second (m/z 50 to 500)
  • Mass stability: Mass drift is < 0.1 Da over a 24 hour period
  • Linearity of response: The linearity of response relative to sample concentration for a specified compound is four orders of magnitude from the limit of detection
  • Polarity switching time: 20 ms to switch between positive and negative ion modes
  • EPCi mode switching time: 20ms to sqitch between ESI and APCI
  • SIR acquisition rate: Minimum dwell time of 3 ms per SIR channel; Minimim inter-channel delay of 3ms
  • Number of SIR channels: Up to 16,384 SIR channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 1024 SIR channels when operating in GLP/secure mode (32 functions, 32 channels per function).
  • Mass resolution: Automatically adjusted (Intellistart) to desired resolution.

 

Learn More
Waters-Acquity-SQD-2-LC-MS-System-15346
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Stack UPLC System

Waters Acquity Stack UPLC System

Cambridge ID #: 9582

Optional UPLC Sample Organizer

Optional Service Contract, Installation, and Training also available

 

The Waters ACQUITY UPLC System provides an integrated configuration for solvent and XYZZ sample management designed for use with ACQUITY UPLC chemistries. The core ACQUITY UPLC System comprises a Binary Solvent Manager, a Sample Manager with integral Column

Heater, and a Solvents Tray. The optional Sample Organizer is available for expanded sample capacity. The full line of Waters MS Technologies products, from single quadrupole to hybrid quadrupole time-of-flight are also available.

 

Includes:

  • TUV Detector or PDA Detector ($1000 more)
  • Sample Manager
  • Column Heater (1 columns)
    • (Optional Column Manager to control up to 4 Columns $2000 extra)
  • Binary Solvent Manager
    • 15000 psi Max Pressure
    • 1034 bars Max Pressure
  • Computer Loaded with Empower
Learn More
Waters-Acquity-Stack-UPLC-System-9582
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping