Persee T8DCS *NEW* Spectrophotometer UV/Vis Reader

Persee T8DCS *NEW* Spectrophotometer UV/Vis Reader

Cambridge ID #: 21349

Features:

T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm. It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field. The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution. The use of a photomultiplier tube as detector delivers exceptional sensitivity.The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.

â—† A high-performance double beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous changeable slit

â—† User friendly design allows easy light source replacement and routine maintenance

â—† Large sample compartment design enables use of a wide range of accessories

Specifications:

  • Optical system: Double beam 
  • Scan speed: Selectable
  • Wavelength range: 190-900 nm
  • Wavelength accuracy: ±0.3 nm
  • Wavelength reproducibility: ≤0.1 nm
  • Spectral bandwidth: 0.1 – 5 nm Continually Adjustable
  • Photometric mode: Transmittance, Absorbance, Energy Concentration, all using UVWin software
  • Photometric range: -4.0-4.0 Abs
  • Photometric accuracy: 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T)
  • Photometric reproducibility: 0.001 A (0-0.5 A)
  • Photometric noise: 0.0004 A (500 nm, 30min warm-up)
  • Baseline flatness: 0.001 A (200-850 nm)
  • Baseline stability: 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up)
  • Stray light: ≤0.01 %T (220 nm NaI, 340 nm NaNO2)
  • Standard functionality: No stand alone function
  • Cell holder: Fixed position sample and reference
  • Detector: Photo multiplier tube
  • Light source: Tungsten Halogen and Deuterium arc lamps
  • Display: No display
  • Printer: Not available
  • PC interface: RS232, USB
  • Software support: UV Win
  • Power supply: Switch mode 120-230 VAC 50-60 Hz
  • Weight: 95 lb
  • Dimension: 21.5 x 23 x 11 in
Learn More
Persee-T8DCS-*NEW*-Spectrophotometer-UV-Vis-Reader-21349
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee T8DS *NEW* Spectrophotometer UV/Vis Reader

Persee T8DS *NEW* Spectrophotometer UV/Vis Reader

Cambridge ID #: 21348

Features:

T8DS is a high performance double beam scanning spectrophotometer with a variable spectral bandwidth. The Czerny-Turner Monochromator with a holographic grating keeps stray light at a minimum and offers excellent optical resolution. The use of a photomultiplier tube as detector delivers exceptional sensitivity. The true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.

â—† Czerny-Turner Monochromator with high resolution holographic grating

â—† High performance variable (0.1, 0.2, 0.5, 1.0, 2.0, 5.0nm) spectral bandwidth 

â—† High resolution, excellent performance, long term stability

â—† Additional accessories for multi-application, support the ultra-volume cuvettes

Specifications:

  • Optical system: Double beam 
  • Scan speed: Selectable
  • Wavelength range: 190-900 nm
  • Wavelength accuracy: ±0.3 nm
  • Wavelength reproducibility: ≤0.1 nm
  • Stray light: ≤0.01 %T (220 nm NaI, 340 nm NaNO2)
  • Photometric mode: Transmittance, Absorbance, Energy Concentration, all using UVWin software
  • Photometric range: -4.0-4.0 Abs
  • Photometric accuracy: 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T)
  • Photometric reproducibility: 0.001 A (0-0.5 A)
  • Photometric noise: 0.0004 A (500 nm, 30min warm-up)
  • Baseline flatness: 0.001 A (200-850 nm)
  • Baseline stability: 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up)
  • Standard functionality: No stand alone function
  • Cell holder: Fixed position sample and reference
  • Detector: Photo multiplier tube
  • Light source: Tungsten Halogen and Deuterium arc lamps
  • Display: No display
  • Printer: Not available
  • PC interface: RS232, USB
  • Software support: UV Win
  • Power supply: Switch mode 120-230 VAC 50-60 Hz
  • Weight: 95 lb
  • Dimension: 21.5 x 23 x 11 in
Learn More
Persee-T8DS-*NEW*-Spectrophotometer-UV-Vis-Reader-21348
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee T9DCS *NEW* Spectrophotometer UV/Vis Reader

Persee T9DCS *NEW* Spectrophotometer UV/Vis Reader

Cambridge ID #: 21350

Features:

The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy. The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics. The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.

â—† True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)

â—† 185– 900nm Wavelength range with Nitrogen purge

â—† Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction

â—† Continuously selectable spectra bandwidth from 0.1-5nm

â—† Beam size continuously adjustable for variety of applications including ultra-volume cuvettes

â—† Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere 

â—† Support WIFI communication in field operation

â—† The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy

Specifications:

  • Optical system: Double beam 
  • Scan Speed: 1000 nm/min, 1500 nm/min location speed
  • Wavelength Range: 185-900 nm
  • Wavelength Accuracy: ±0.2 nm
  • Spectral Bandwidth: ±20 % (0.1 nm-5 nm continuously adjustable)
  • Photometric Model: Transmittance,Absorbance, Enegy and Concentration
  • Photometric Range: -6.0 Abs-6.0 Abs
  • Baseline Flatness: ±0.0008 Abs
  • Baseline Stability: 0.1 %/hr
  • Cell Holder: Automatic 8 Cell Changer
Learn More
Persee-T9DCS-*NEW*-Spectrophotometer-UV-Vis-Reader-21350
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Cambridge ID #: 18159

Specifications:

 

Site Requirements

  • Dimensions (W x D x H): 416 × 379 × 274mm
  • Weight: 11 kg
  • Ambient temperature: 15 to 35°C
  • Ambient humidity: 45 to 80%, less than 70% if over 30°C
  • Power supply: 100~120 V 50/60 Hz 160 VA ; 220~240 V 50/60 Hz 160 VA

Performance Specifications:

  • Spectrum bandwidth: 5 nm
  • Wavelength accuracy: ± 1.0 nm
  • Wavelength repeatability: ± 0.3 nm
  • Stray light: less than 0.05% (220.0 nm Nal, 340.0 nm NaNO2 & UV39)
  • Photometric range: −3.99 to 3.99 Abs (absorbance) ;  0.0 to 200% (transmittance)
  • Recording range: −3.99 to 3.99 Abs (absorbance) ;  −399 to 399% (transmittance)
  • Photometric accuracy: ± 0.005 Abs (at 1.0 Abs) ; ± 0.003 Abs (at 0.5 Abs)
  • Photometric repeatability: ± 0.002 Abs (at 1.0 Abs)
  • Drift: less than ± 0.001 Abs/h (after 2 hr warm-up)
  • Baseline flatness: ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm)
  • Noise: less than 0.002 Abs, Peak to Peak / less than 0.0005 Abs, RMS

Optical Design

  • Wavelength range: 190.0 to 1100.0 nm
  • Display wavelength: 0.1nm step
  • Selectable wavelength: 0.1 nm step (1 nm step in spectrum mode)
  • Scan speed: ± 3800 nm/min (wavelength change) ; ± 24 to 1400 nm/min (scan)
  • Light source change: Auto change with wavelength ; halogen lamp only ; deuterium (D2) lamp only
  • Measurement method: single beam measurement
  • Monochromator: incorporates aberration-corrected concave blazed holographic grating
  • Detector: silicon photodiode
Learn More
Shimadzu-UVmini-1240-Spectrophotometer-UV-Vis-Reader-18159
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  VXMPAL *NEW* Vortexer

Ohaus VXMPAL *NEW* Vortexer

Cambridge ID #: 20247

Features:

OHAUS Microplate Vortex Mixers are perfect for mixing microplates throughout the speed range. All models are designed for continuous-duty use in the lab. Digital models offer a timer and exact speed control for applications that demand repeatable results and non-digital variable speed models are an economical alternative. The high-speed and small orbit of these mixers make them optimal for effectively mixing microplates.

Applications

ELISA Assays, PCR Preparations, Digestions, Cell Disruptions

Display

Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)

Operation

Detachable 3-wire cord and plug (included)

Communication

N/A

Construction

Cycoloy

Design Features

Microplate adapter and cup head (included)

 

Specifications:

 

 

  • Control:Analog
  • Duty Rating:Continuous
  • Orbit:0.1 in (3.5 mm)
  • Speed Range:On Mode, 300 rpm – 2500 rpm;  Touch Mode, 300 rpm – 3500 rpm
  • Capacity:2 Microplates
  • Dimensions (HxLxW):4.5 in x 10.5 in x 5.4 in (11.4 cm x 26.7 cm x 13.7 cm)
  • Net Weight:11.7 lb (5.3 kg)
  • Power:120V, 0.25A, 50/60Hz
  • Power Consumption:30 W
  • Safety Certification:TUV

 

  • Working Environment:39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing)
Learn More
Ohaus-VXMPAL-*NEW*-Vortexer-20247
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 13408, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Sorvall 75006445 Rotor

Sorvall 75006445 Rotor

Cambridge ID #: 17237

This rotor fits legend RT Plus, legend T, Heraeus Multifuge 3S Plus, Multifuge 3SR Plus
With 4 deepwell microplate carriers, part (2) 75006449K & (2) 75006449J
And 4  TaqMan Array Micro Fluidic Card Holders

Specifications:

  • Maximum speed: 4,600 RPM
  • Maximum capacity: 4 x 750ml.

 

 

Learn More
Sorvall-75006445-Rotor-17237
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sorvall Heraeus 75006445 Rotor

Sorvall Heraeus 75006445 Rotor

Cambridge ID #: 15470

This rotor fits legend RT Plus, legend T, Heraeus Multifuge 3S Plus, Multifuge 3SR Plus
With 4 deepwell microplate carriers, part (2) 75006449K & (2) 75006449J
And 4  TaqMan Array Micro Fluidic Card Holders

Specifications:

  • Maximum speed: 4,600 RPM
  • Maximum capacity: 4 x 750ml.

 

 

Learn More
Sorvall-Heraeus-75006445-Rotor-15470
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Eppendorf A-2-MTP Rotor

Eppendorf A-2-MTP Rotor

Cambridge Scientific ID #'s: 13156, 13155, 13608, 20085

The Eppendorf A-2-MTP Microplate Rotor is compatible with 5804-5810 series centrifuges. This 2-plate microplate rotor is ideal for use after reaction setup and before PCR amplification or ELISA assays.

Specifications:

  • Maximum Speed: 4680 rpm
  • Maximum RCF: 2204 xg
  • Maximum Capacity: 29 mm height
Learn More
Eppendorf-A-2-MTP-Rotor-13156
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
 ACL TOP 500 CTS

ACL TOP 500 CTS

Cambridge ID #: 22616

Highly automated with a compact size and complete end-to-end automation, offers a broad menu for routine and specialty assays.

Specifications:

  • Test menu: Clotting, chromogenic and immunological assays
  • Continuous sample and reagent loading: YES
  • Continuous operation: YES
  • Sample and reagent transport system: Racks
  • Samples onboard: 80 (10/sample rack)
  • Closed-Tube Sampling: YES (cap-piercing)
  • Reagents onboard: 40 (refrigerated)
  • Reagents barcode reader: YES (integrated)
  • Barcoded reagents: YES (barcode includes lot, exp. date and vial size)
  • Cuvettes onboard: 800
  • Applications onboard: 500 (250 user-definable)
  • Tests/sample: 30
  • Throughput:
    • PT: up to 240 tests/hr (240 samples/hr)
    • APTT: up to 180 tests/hr (180 samples/hr)
    • PT/APTT: up to 180 tests/hr (90 samples/hr)
  • Sample predilution: YES
  • Calibration curve predilution: YES
  • Factor parallelism: YES
  • Rerun and reflex testing: YES (configurable)
  • Reaction-curves display: YES
  • Quality Control program: YES (with configurable multi-rules)
  • Results autovalidation: YES
  • Patient sample results database: 20,000 samples (configurable)
  • Security system: YES (configurable)
  • Events log system: YES
  • Bidirectional interface: YES
  • Host query function: YES
  • PC: External (dedicated)
  • Operating system: Windows XP
  • Monitor: 17-inch color LCD touchscreen (external)
  • Keyboard: YES (external)
  • Mouse: YES (external)
  • Printer: YES (external)
  • User interface: Windows XP-based
  • Unit dimensions (w x d x h): 110 x 82 x 73 cm (43 x 32 x 29 in)
  • Weight (analyzer): 147 kg (324 lbs)
Learn More
-ACL-TOP-500-CTS--22616
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Illumina BeadXpress Laser Detection Bioassay SystemImage Coming Soon

Illumina BeadXpress Laser Detection Bioassay System

Cambridge ID #: 9551

Description:

Illumina’s BeadXpress Reader was specifically developed to analyze bioassay applications using the versatile VeraCode technology. With the broadest multiplexing range in the industry, the BeadXpress Reader is the optimal solution for small and high-throughput laboratories conducting molecular testing applications that benefit from robust, multiplexed-based assays. VeraCode technology presents a digital revolution for multiplex testing in genotyping, gene expression, and protein-based assays. The unique holographic code embedded in each VeraCode bead type delivers unparalleled data quality by enabling customizable tracking and providing an unprecedented level of data precision and verifiability.

Specifications:

  • Altitude: up to 2400 m
  • Temperature range: 15°C to 30°C
  • Humidity: 20 to 80% RH
  • Electrical Ratings: 90–260 V (AC), 2.0 A, 50/60 Hz, Class I
  • Dimensions (W x D x H): 47 cm x 77 cm x 62 cm
  • Weight: 57 kg
  • Laser Classification: Class I laser instrument housing two internal Class 3B lasers (IEC 60825-1, 1.2, 1993)
  • Power: Dedicated circuit; BeadXpress Reader (110V): 15 A; BeadXpress Reader (220V): 12 A

 

 

Learn More
Illumina-BeadXpress-Laser-Detection-Bioassay-System-9551
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek BioSpa Incubator

BioTek BioSpa Incubator

Cambridge ID #: 21107

Features:

BioSpa™ 8 Automated Incubator links BioTek readers and imagers together with washers and dispensers for full workflow automation of up to 8 microplates or other labware. BioSpa 8 can automate your workflows, from ELISA to long term live cell assays. Temperature and CO2/O2 control, plus humidity monitoring and lid handling ensure an ideal environment for cell cultures during all experiment stages, with minimal manual intervention. BioSpa's software records and reports session timelines and environmental conditions, while customizable text and email alerts assure confidence during long and short term runs. Link a washer or dispenser and a plate reader or imager for start-to-finish workflow automation.

 

Specifications:

  • Description: Incubation to 45°C and CO2/O2 control and monitoring, water pan and humidity monitoring
  • CO2 Control : Range 0 – 20%,
  • Control resolution ±0.1%,
    • Stability: ±0.2 at 5% CO2; O2
  • Control: Range: 1 – 19%,
  • Control resolution:±0.1%,
    • Stability: ±0.2 at 1% O2
  • Humidity: rH 80 to 95% (lidded plates and 5% CO2)
Learn More
BioTek-BioSpa-Incubator-21107
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Cary Eclipse Fluorescence Spectrophotometer

Agilent Cary Eclipse Fluorescence Spectrophotometer

Cambridge ID #: 21019

Features:

  • Multiple collection modes: Fluorescence, phosphorescence, chemi/bio-luminescence, and time resolved phosphorescence measurements can all be easily made without changing a single hardware component
  • Lowest cost of ownership: The Cary Eclipse is so robust and reliable that every new instrument comes with a 10-year lamp life guarantee, reducing ongoing expenses to virtually zero. 
  • Improved laboratory safety: Additionally the guaranteed exceptionally long lifetime of the lamp in the Cary Eclipse eliminates lamp replacements, a hugely time-consuming and potentially hazardous operation.
  • Easy to use: Modular, application-specific software, which satisfies the needs of novice and expert users alike, and the ability to switch between measurement modes without touching the hardware, ensure that any user can quickly get reliable, accurate results with minimal training.
  • Expand your analytical capabilities: The superior, unique design of the Cary Eclipse ensures room light immunity allowing the instrument to operate with the front and top panels removed for easy access to sample and fast installation of large accessories.
  • Proven sensitivity where you need it most: Optimized design coupled with unique, high-sensitivity optics and detectors ensure that the Cary Eclipse gives you the performance that you need right across the spectrum. 
  • Robustness, reliability and sensitivity: Engineered to be the most robust instrument on the market, the Cary Eclipse incorporates the unique Agilent xenon flash lamp to capture a data point every 12.5 ms and scans at 24,000 nm/min without peak shifts perfect for high throughput laboratories and fast kinetics applications.
  • Unique Sampling: By incorporating Agilent’s unique capacity to guarantee room light immunity coupled with the highly accurate and reproducible Peltier temperature control, the Cary Eclipse delivers unique sampling opportunities that will expand your analytical capabilities, simplify your workflow and increase your sample throughput.
  • Reliable Results: The Cary Eclipse only illuminates the sample when data is actually being acquired. This means that the Cary Eclipse prevents your valuable samples from photodegradation and preserves their integrity to the point that you can measure them over and over again and continue to get the same, reliable result. 

Specifications:

  • Dimensions(WxDxH): 60 x 64 x 27 cm (23 x 25 x 10 inches)
  • Sensitivity:> 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
  • Wavelength(s):190 - 1100 nm
  • Temperature Range: 10 – 35°C
  • Optical System: Cerny-Turner 0.125 m Monochromators
  • Light Source: Xenon Flash Lamp
  • Software: Cary Eclipse Software
Learn More
Agilent-Cary-Eclipse-Fluorescence-Spectrophotometer-21019
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Guava EasyCyte Flow Cytometer

Guava EasyCyte Flow Cytometer

Cambridge ID #: 16054

Single Laser Configuration

 

Includes Computer Loaded with Cytosoft Software

 

The guava easyCyte flow cytometry systems are cost-effective, easy to use and deliver complete and comprehensive cell analysis- right on your benchtop. The culmination of over a decade of flow cytometry expertise, these instruments consume less sample, generate less waste and are easier to use and maintain than traditional flow cytometers—all while providing the analytical power you need to expand your research horizons.

 

Features:

  • Blue Laser
  • Forward and Side Scatter
  • Tube Sampling
  • Automated 96 Well Micrplate Sampling
  • Small Sample Size (<20 μL)
  • Minimal waste (<50 mL per day)
  • Detectors
    • Green
    • Yellow
    • Red

 

Fluidics Specifications:

  • Flow Cell Dimension: Standard square capillary with ID of 100 µm
  • Pump: Positive displacement
  • Sheath Fluid: None
  • Sample Flow Rate: 7µL/min to 72 µL/min
  • Waste Generation: typically <40mL in 8 hours of continuous use
  • Dead Volume: 50 µL (for 96-well microplate)
  • Sample Requirement: as few as 2,000 cells/test; typically 25,000 – 100,000 cells
  • Cell Size: 1-60 µm
  • Typical # of Cells/Protocol: 1,000 – 10,000 cells/test
Learn More
Guava-EasyCyte-Flow-Cytometer-16054
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek EL-404 Microreactor WasherImage Coming Soon

BioTek EL-404 Microreactor Washer

Cambridge Scientific ID #'s: 7111, 4340, 8257

Includes Pump and Bottles

 

Features

  • Accommodates all 96-well microplates
  • Semi-automatic or automatic height positioning.
  • Wash/aspirate 96 wells simultaneously in 8 sec.

 

Specifications:

  • Fluid Dispensing: Gravity-fed, transducer controlled fill volumes. (Includes Presurized delivery system.)
  • Fill Volumes: Set from 100 to 500 microlitres in 25 microlitre increments; set from 500 to 999 microlitres in 100 microlitres increments.
  • Wash Cycles: Select from 1 to 9.
  • Soak: 5-second increments from 0 to 600 seconds.
  • Plate Soaking: Frequency - 5 to 15 cycles per second. Duration - 0 to 30 seconds.
  • Dispensing Accuracy: Well-to-well variation - +/-5% at 350 microlitres
  • Suction Efficiency: 6 microlitre maximum residual per well; adjustable
Learn More
BioTek-EL-404-Microreactor-Washer-7111