Used Lab Equipment

Used Lab Equipment

We offer an assortment of items that does not fall under the rest of the categories. This section contains items ranging from Capillary Electrophoresis, Microarray Scanners, to pH meters and Orbital Shakers. If there is an item you do not see that you are looking for, please send us a request and we will be sure to help.

Microplate Visible/absorbance Reader: 61-75 of 130

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Persee T9DCS *NEW* Spectrophotometer UV/Vis Reader

Persee T9DCS *NEW* Spectrophotometer UV/Vis Reader

Cambridge ID #: 21350

Features:

The T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy. The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics. The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.

â—† True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)

â—† 185– 900nm Wavelength range with Nitrogen purge

â—† Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction

â—† Continuously selectable spectra bandwidth from 0.1-5nm

â—† Beam size continuously adjustable for variety of applications including ultra-volume cuvettes

â—† Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere 

â—† Support WIFI communication in field operation

â—† The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy

Specifications:

  • Optical system: Double beam 
  • Scan Speed: 1000 nm/min, 1500 nm/min location speed
  • Wavelength Range: 185-900 nm
  • Wavelength Accuracy: ±0.2 nm
  • Spectral Bandwidth: ±20 % (0.1 nm-5 nm continuously adjustable)
  • Photometric Model: Transmittance,Absorbance, Enegy and Concentration
  • Photometric Range: -6.0 Abs-6.0 Abs
  • Baseline Flatness: ±0.0008 Abs
  • Baseline Stability: 0.1 %/hr
  • Cell Holder: Automatic 8 Cell Changer
Learn More
Persee-T9DCS-*NEW*-Spectrophotometer-UV-Vis-Reader-21350
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Cambridge ID #: 18159

Specifications:

 

Site Requirements

  • Dimensions (W x D x H): 416 × 379 × 274mm
  • Weight: 11 kg
  • Ambient temperature: 15 to 35°C
  • Ambient humidity: 45 to 80%, less than 70% if over 30°C
  • Power supply: 100~120 V 50/60 Hz 160 VA ; 220~240 V 50/60 Hz 160 VA

Performance Specifications:

  • Spectrum bandwidth: 5 nm
  • Wavelength accuracy: ± 1.0 nm
  • Wavelength repeatability: ± 0.3 nm
  • Stray light: less than 0.05% (220.0 nm Nal, 340.0 nm NaNO2 & UV39)
  • Photometric range: −3.99 to 3.99 Abs (absorbance) ;  0.0 to 200% (transmittance)
  • Recording range: −3.99 to 3.99 Abs (absorbance) ;  −399 to 399% (transmittance)
  • Photometric accuracy: ± 0.005 Abs (at 1.0 Abs) ; ± 0.003 Abs (at 0.5 Abs)
  • Photometric repeatability: ± 0.002 Abs (at 1.0 Abs)
  • Drift: less than ± 0.001 Abs/h (after 2 hr warm-up)
  • Baseline flatness: ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm)
  • Noise: less than 0.002 Abs, Peak to Peak / less than 0.0005 Abs, RMS

Optical Design

  • Wavelength range: 190.0 to 1100.0 nm
  • Display wavelength: 0.1nm step
  • Selectable wavelength: 0.1 nm step (1 nm step in spectrum mode)
  • Scan speed: ± 3800 nm/min (wavelength change) ; ± 24 to 1400 nm/min (scan)
  • Light source change: Auto change with wavelength ; halogen lamp only ; deuterium (D2) lamp only
  • Measurement method: single beam measurement
  • Monochromator: incorporates aberration-corrected concave blazed holographic grating
  • Detector: silicon photodiode
Learn More
Shimadzu-UVmini-1240-Spectrophotometer-UV-Vis-Reader-18159
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  VXMPAL *NEW* Vortexer

Ohaus VXMPAL *NEW* Vortexer

Cambridge ID #: 20247

Features:

OHAUS Microplate Vortex Mixers are perfect for mixing microplates throughout the speed range. All models are designed for continuous-duty use in the lab. Digital models offer a timer and exact speed control for applications that demand repeatable results and non-digital variable speed models are an economical alternative. The high-speed and small orbit of these mixers make them optimal for effectively mixing microplates.

Applications

ELISA Assays, PCR Preparations, Digestions, Cell Disruptions

Display

Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)

Operation

Detachable 3-wire cord and plug (included)

Communication

N/A

Construction

Cycoloy

Design Features

Microplate adapter and cup head (included)

 

Specifications:

 

 

  • Control:Analog
  • Duty Rating:Continuous
  • Orbit:0.1 in (3.5 mm)
  • Speed Range:On Mode, 300 rpm – 2500 rpm;  Touch Mode, 300 rpm – 3500 rpm
  • Capacity:2 Microplates
  • Dimensions (HxLxW):4.5 in x 10.5 in x 5.4 in (11.4 cm x 26.7 cm x 13.7 cm)
  • Net Weight:11.7 lb (5.3 kg)
  • Power:120V, 0.25A, 50/60Hz
  • Power Consumption:30 W
  • Safety Certification:TUV

 

  • Working Environment:39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing)
Learn More
Ohaus-VXMPAL-*NEW*-Vortexer-20247
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1315A HPLC Diode Array Detector

Agilent 1100 Series - G1315A HPLC Diode Array Detector

Cambridge ID #: 19152

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19152
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1315B HPLC Diode Array Detector

Agilent 1100 Series - G1315B HPLC Diode Array Detector

Cambridge ID #: 16038

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-16038
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17971, 13182, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17971
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1260 Series - G1315D HPLC Diode Array Detector

Agilent 1260 Series - G1315D HPLC Diode Array Detector

Cambridge ID #: 20570

Features:

The detector is designed for highest optical performance, GLP compliance and easy maintenance. 

Specifications:

  • Detection Type: 1024-element photodiode array
  • Light Source: Deuterium and tungsten lamps The UV-lamp is equipped with RFID tag that holds lamp typical information.
  • Data Rate: up to 80 Hz
  • Wavelength Range: 190 – 950 nm
  • Short Term: noise (ASTM) Single and Multi-Wavelength: < ± 0.7·10-5 AU at 254 and 750 nm
  • Drift: < 0.9·10-3 AU/h at 254 nm 
  • Linear Absorbance Range: > 2 AU (5 %) at 265 nm
  • Wavelength Accuracy: ± 1 nm ,Self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength Bunching: 1 – 400 nm, Programmable in steps of 1 nm
  • Slit Width: 1, 2, 4 , 8, 16 nm Programmable slit
  • Diode Width: < 1 nm
Learn More
Agilent-1260-Series---G1315D-HPLC-Diode-Array-Detector-20570
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters 2487 HPLC UV/VIS Detector

Waters 2487 HPLC UV/VIS Detector

Cambridge ID #: 16396

The Waters 2487 Dual λ Absorbance Detector is a two-channel, tunable, ultraviolet/visible (UV/Vis) detector designed for high-performance liquid chromatography (HPLC) applications. The Waters 2487 Dual λ Absorbance Detector can operate either as a stand-alone unit (with a chart recorder or integrator) or as an integral part of a Waters chromatography system.

 

Specifications:

  • Wavelength range: 190 to 700 nm
  • Bandwidth: <5 nm
  • Wavelength accuracy: +1.0 nm
  • Wavelength repeatability: +0.1 nm
  • Single λ dry noise: <5 µAU (at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
  • Wet noise: <8 µAU (at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
  • Dual channel noise (dry): <35 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)
  • Dual channel noise (wet): <45 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)
  • Linearity: <5% at 2.5 AU, propylparaben at 257 nm
  • Drift: 1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
  • Thermal drift: 1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
  • Sensitivity setting range: 0.0001 to 4.0000 AUFS
  • Filter setting range
    • Single-wavelength: 0.1 to 5.0 seconds
    • Dual-wavelength: 1 to 50 seconds
  • Time-constant: To 5.0-second Hamming filter
  • Digital data rates:
    • 1,2,5,10,20,40,80 Hz (single channel)
    • 1,2 Hz (dual channel)
  • Analog output data rates (single λ mode):
    • 10,20,40,80 Hz (channel A)
    • 10 Hz only (channel B)
  • Lamp source: 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
  • Second-order filter: Automatic for wavelengths > 370 nm
  • Wavelength calibration filter: Erbium filter, used at startup or on demand
  • Flow cell: TaperSlit flow cell design
  • Nitrogen purge: Purge fitting present on optics bench
  • Path length: 0 mm (standard analytical)
  • Cell volume: 10 µL (standard analytical)
  • Pressure limit: 6895 kPa (69 bar,1000 psi)
  • Materials: 316 stainless steel, fused silica, Tygon
  • Operating temperature: 4 to 40 °C (39 to 104 °F)
  • Operating humidity: 20% to <95%, noncondensing

Learn More
Waters-2487-HPLC-UV-VIS-Detector-16396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fotodyne 3-3700 Transilluminator

Fotodyne 3-3700 Transilluminator

Cambridge ID #: 7438

Description:

Designed for multiple applications, the VariQuest 100 is excellent for situations requiring uniform visible light illumination such as viewing or photographing protein gels. Designed for multiple applications, the VariQuest 100 is excellent for situations requiring uniform visible light illumination such as viewing or photographing protein gels, autoradiograms or microtiter plates. The 21 x 38 cm flashed opal glass surface, combined with continuously adjustable intensity, provides superior control for different lighting requirements. High uniformity makes this transilluminator excellent for digitizing autoradiograms.

Specifications:

  • Large 21 x 38 cm flashed opal glass viewing surface
  • Continuously adjustable intensity control from 30% to 100%
  • Four 15-watt color-corrected white light bulbs
  • UviClear glass protector
Learn More
Fotodyne-3-3700-Transilluminator-7438
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Forma 3940 Environmental Chamber Incubator

Forma 3940 Environmental Chamber Incubator

Cambridge ID #: 17267

Specifications:

  • Humidity Control
  • Temperature Range: 0°C to 60°C
  • Chamber Volume: 29 Cubic Feet / 821.2 Liters
  • Temperature Uniforimity: ±0.3°C at 37°C
  • Temperature Sensitiviy: ±0.1°C
  • Chamber Dimensions (HxWxD):  60” x 31” x 27”
  • Exterior Dimensions: (HxWxD):  88.5” x 38” x 32”
  • Weight: 1040 LBS
  • Capacity: 29 cu. ft. (821.2L)
  • Voltage: 208/220V 60 Hz, 15.0A
  • 4-wire power cord (including ground)
  • NEMA 14-20P plug
  • 6 solid stainless-steel shelves
  • Exterior D x W x H: 32 x 38 x 88.5 in. (81.3 x 96.5 x 224.8cm)
  • Interior D x W x H: 27 x 31 x 60 in. (68.6 x 78.7 x 152.4cm)

Broad Range of Features and Controls

  • Wide temperature range of 0° to 60°C enhances the flexibility of the unit
  • Relative humidity control via steam generator from above ambient to 95% at 37°C†
  • Sophisticated digital controls
  • Programmable ramp and soak cycles for temperature and RH†
  • Durable cabinets feature true laminar airflow through side plenums for extremely tight uniformity
  • Phenolic-coated evaporator for use in applications that create corrosive byproducts
  • Manual control of defrost and refrigeration cycles
  • Visible/audible safety alarms alert to over- and undertemperature conditions, deviation of humidity from set parameters (except Model 3920)

Durable Construction

  • Cold-rolled steel, powder-coated cabinet
  • 0 in. (5.1cm) thick, CFC-free, foamed-in-place polyurethane insulation
  • Stainless-steel interior
  • Solid stainless-steel adjustable shelves
  • Directed horizontal airflow system for excellent uniformity
  • Locking swivel casters ensure easy mobility during installation and cleaning
  • Leveling feet provide stability and added safety in the lab
Learn More
Forma-3940-Environmental-Chamber-Incubator-17267
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Scienceware Bel-Art Products 420741116 DesiccatorImage Coming Soon

Scienceware Bel-Art Products 420741116 Desiccator

Cambridge ID #: 13369

Description:

  • A UV light blocking, dry environment with automatic electronic dehumidification
  • The attractive design and sturdy construction of the Secador line of desiccator cabinets assures easy and reliable storage of moisture and light sensitive products.
  • Patented electronic dehumidification system reduces humidity and circulates dry air automatically, freeing users from monitoring and changing desiccants
  • Durastar™ co-polyester construction blocks 99% of UV light and resists staining, crazing and chemical attack
  • Amber color models reduce visible light penetration by over 50% for storing light sensitive materials like reagents, analytical standards and investigational compounds
  • Large doors with easy-to-view dial hygrometer maximize access to interior space and have a patented seal design, tab latches and security loops for a padlock or tamper-evident seals
  • Perforated shelves facilitate circulation of dry air; Space for desiccant under bottom shelf
  • U.S. Patents: 6,772,534; 6,834,920; 7,114,266; 7,318,630 and D474,626

Specifications:

  • Temperature Range: 41° to 104°F (5° to 40°C)
  • Voltage: 120 V
  • Shelf Type: Vented adjustable shelves
  • Material: Copolyester
  • Color: Clear with Blue End Caps
  • Shelves: 3
  • Autoclavable: No
  • Dimensions (L x W x H): 16.3 x 13.4 x 20.4 in. (41.4 x 34.1x 51.8 cm)
  • For Use With (Application): Easy and reliable storage of moisture and light sensitive products, can be used with Scienceware™ desiccant cartridges, canisters or similar desiccant
Learn More
Scienceware-Bel-Art-Products-420741116-Desiccator-13369
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping