We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Microplate Visible/absorbance Reader: 76-90 of 147

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge ID #: 16028

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific FB15012 Vortexer

Fisher Scientific FB15012 Vortexer

Cambridge ID #: 21796
  • Fisher Scientific FB15012 TopMix Vortex Mixer with optional microplate holder
  • Continuous or Touch operated
  • Max RPM 3,000
  • Supplied with 2 attachements (Cup for test tubes and microplate holder)
  • Serial# 139312
  • Dims 22cm (D) x 18cm (W) x 9cm (H)
  • Learn More
    Fisher-Scientific-FB15012-Vortexer-21796
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Cambridge ID #: 11049

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1315B HPLC Diode Array Detector

    Agilent 1200 Series - G1315B HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 24130, 24948, 24717

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1315B-HPLC-Diode-Array-Detector-24130
    By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Cambridge Scientific ID #'s: 23960, 17971, 13182, 23203, 16326, 21821

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-23960
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Agilent 1200 Series - G1315C HPLC Diode Array Detector

    Agilent 1200 Series - G1315C HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 25482, 25380

    The Agilent 1200 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1315C-HPLC-Diode-Array-Detector-25482
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1200 Series - G1316A HPLC Column Compartment

    Agilent 1200 Series - G1316A HPLC Column Compartment

    Cambridge Scientific ID #'s: 25604, 24949, 25084, 24128, 24719, 23962

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1316A-HPLC-Column-Compartment-25604
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Agilent 1260 Series - G1315D HPLC Diode Array Detector

    Agilent 1260 Series - G1315D HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 24158, 25082

    Features:

    The detector is designed for highest optical performance, GLP compliance and easy maintenance. 

    Specifications:

    • Detection Type: 1024-element photodiode array
    • Light Source: Deuterium and tungsten lamps The UV-lamp is equipped with RFID tag that holds lamp typical information.
    • Data Rate: up to 80 Hz
    • Wavelength Range: 190 – 950 nm
    • Short Term: noise (ASTM) Single and Multi-Wavelength: < ± 0.7·10-5 AU at 254 and 750 nm
    • Drift: < 0.9·10-3 AU/h at 254 nm 
    • Linear Absorbance Range: > 2 AU (5 %) at 265 nm
    • Wavelength Accuracy: ± 1 nm ,Self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength Bunching: 1 – 400 nm, Programmable in steps of 1 nm
    • Slit Width: 1, 2, 4 , 8, 16 nm Programmable slit
    • Diode Width: < 1 nm
    Learn More
    Agilent-1260-Series---G1315D-HPLC-Diode-Array-Detector-24158
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 24720, 23961, 25377, 24073

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-24720
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Eppendorf A-2-MTP Rotor

    Eppendorf A-2-MTP Rotor

    Cambridge Scientific ID #'s: 13156, 13155, 13608, 20085

    The Eppendorf A-2-MTP Microplate Rotor is compatible with 5804-5810 series centrifuges. This 2-plate microplate rotor is ideal for use after reaction setup and before PCR amplification or ELISA assays.

    Specifications:

    • Maximum Speed: 4680 rpm
    • Maximum RCF: 2204 xg
    • Maximum Capacity: 29 mm height
    Learn More
    Eppendorf-A-2-MTP-Rotor-13156
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Agilent 1200 Series - G1364C HPLC Fraction Collector

    Agilent 1200 Series - G1364C HPLC Fraction Collector

    Cambridge Scientific ID #'s: 25481, 25601

    Features:

     

    • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
    • For analytical scale applications

     

    Specifications:

    • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
    • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
    • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
    • Maximum tube volume: ca. 45 ml
    • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
    • Delay volumes [μl]:
      • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
      • Diverter valve: ~15
      • Diverter valve to needle: ~110
      • Needle: -~5
    • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
    • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
    • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
    • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
    • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
    • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1364C-HPLC-Fraction-Collector-25481
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Denley Well Wash 2 Microreactor Washer

    Denley Well Wash 2 Microreactor Washer

    Cambridge ID #: 12519

    Features:

     

    Denley Wellwash 4 MK2 Microplate Washer 12 way head

    Learn More
    Denley-Well-Wash-2-Microreactor-Washer-12519
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1260 Series - G1315C HPLC Diode Array Detector

    Agilent 1260 Series - G1315C HPLC Diode Array Detector

    Cambridge ID #: 25655

    The Agilent 1260 Inifnity Series G1315C Diode Array Detector VL+ is designed for highest optical performance, GLP compliance and easy maintenance. 80 Hz data acquisition rate for fast LC applications. data recovery (DRC) feature provides data-never-lost insurance. RFID tags for all flow cells and UV-lamps provides traceable information about these assemblies. No loss in sensitivity for up to eight wavelengths simultaneous. Built-in temperature control for improved baseline stability.

    Specifications:

    Detection type: 1024-element photodiode array
    Light source: 
    Deuterium and tungsten lamps
    Data rate: 
    up to 80 Hz
    Wavelength range: 
    190 – 950 nm
    Short term noise (ASTM) Single and Multi-Wavelength:
    < 0.7·10-5 AU at 254 and 750 nm
    Drift:<
     0.9·10-3 AU/h at 254 nm
    Linear absorbance range:
     > 2 AU (5°) at 265 nm
    Wavelength accuracy: ±
     1 nm
    Wavelength bunching: 
    1 – 400 nmProgrammable in steps of 1 nm
    Slit width:
    1, 2, 4 , 8, 16 nm
    Diode width: 
    < 1 nm
    Control and data evaluation:
    Agilent ChemStation for LC (32-bit)
    Local Control: 
    Agilent Instant Pilot (G4208A)
    Analog outputs: 
    Recorder/integrator: 100 mV or 1 V output range 0.001 – 2 AU, two outputs

    Learn More
    Agilent-1260-Series---G1315C-HPLC-Diode-Array-Detector-25655
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Ohaus AquaSearcher pH MeterImage Coming Soon

    Ohaus AquaSearcher pH Meter

    Cambridge ID #: 24945

    Features:

     

    The newest edition to OHAUS' original Starter Series, the AquaSearcher is a user-friendly and versatile pH meter designed with reliable measurement in mind. Its 6.5 inch LCD display is visible even from a distance, and its touch keypad makes executing functions easy. Capable of measuring up to 7 parameters, using 2 independant measuring channels that can work simultaneously, this pH meter is the most intuitive and modern in its series.

     

    Specifications:

    Measurement Range: -2.00 – 20.00 pH;-5 °C – 110 °C;-2000.00 – +2000.00 mV
     
    Measurement Resolution: 0.1 mV;0.1 °C;0.01 pH
     
    Accuracy: ±0.3 °C;±0.5 mV;±0.01 pH
     
    Display: LCD with backlight & one-line dot matrix
     
    Learn More
    Ohaus-AquaSearcher-pH-Meter-24945
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Waters 2487 HPLC UV/VIS Detector

    Waters 2487 HPLC UV/VIS Detector

    Cambridge Scientific ID #'s: 16396, 22189

    The Waters 2487 Dual λ Absorbance Detector is a two-channel, tunable, ultraviolet/visible (UV/Vis) detector designed for high-performance liquid chromatography (HPLC) applications. The Waters 2487 Dual λ Absorbance Detector can operate either as a stand-alone unit (with a chart recorder or integrator) or as an integral part of a Waters chromatography system.

     

    Specifications:

    • Wavelength range: 190 to 700 nm
    • Bandwidth: <5 nm
    • Wavelength accuracy: +1.0 nm
    • Wavelength repeatability: +0.1 nm
    • Single λ dry noise: <5 µAU (at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
    • Wet noise: <8 µAU (at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
    • Dual channel noise (dry): <35 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)
    • Dual channel noise (wet): <45 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)
    • Linearity: <5% at 2.5 AU, propylparaben at 257 nm
    • Drift: 1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
    • Thermal drift: 1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
    • Sensitivity setting range: 0.0001 to 4.0000 AUFS
    • Filter setting range
      • Single-wavelength: 0.1 to 5.0 seconds
      • Dual-wavelength: 1 to 50 seconds
    • Time-constant: To 5.0-second Hamming filter
    • Digital data rates:
      • 1,2,5,10,20,40,80 Hz (single channel)
      • 1,2 Hz (dual channel)
    • Analog output data rates (single λ mode):
      • 10,20,40,80 Hz (channel A)
      • 10 Hz only (channel B)
    • Lamp source: 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
    • Second-order filter: Automatic for wavelengths > 370 nm
    • Wavelength calibration filter: Erbium filter, used at startup or on demand
    • Flow cell: TaperSlit flow cell design
    • Nitrogen purge: Purge fitting present on optics bench
    • Path length: 0 mm (standard analytical)
    • Cell volume: 10 µL (standard analytical)
    • Pressure limit: 6895 kPa (69 bar,1000 psi)
    • Materials: 316 stainless steel, fused silica, Tygon
    • Operating temperature: 4 to 40 °C (39 to 104 °F)
    • Operating humidity: 20% to <95%, noncondensing

    Learn More
    Waters-2487-HPLC-UV-VIS-Detector-16396