We offer an assortment of refurbished and used Microscopes ranging from Inverted Microscopes, Compound Microscopes, Fluorescence Microscopes, Stereo/Dissecting Microscopes, and Biological Microscopes to Polarizing Microscopes. Some of our popular manufacturers include Nikon, Olympus, Zeiss, and Leica. We also feature microscope cameras, objectives and stands. Additionally, we sell a wide selection of Scanning Electron Microscopes including Hitachi and JEOL. Browse our used microscopes below.

Microplate Visible/absorbance Reader: 106-120 of 146

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
BioTek ELX405UV

BioTek ELX405UV

Cambridge ID #: 25016

Featuring:
• 96 well microplate washing

Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual

Learn More
BioTek-ELX405UV--25016
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek ELX405VR

BioTek ELX405VR

Cambridge Scientific ID #'s: 25135, 17063

Featuring:
• 96 well microplate washing

Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual

Learn More
BioTek-ELX405VR--25135
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
UVP EpiChemi3 Darkroom Gel Imaging System

UVP EpiChemi3 Darkroom Gel Imaging System

Cambridge ID #: 12255

 Features:

  • Applications: fluorescence and colorimetric
  • Software: easy-to-use software for darkroom control, image capture, enhancement and analysis
  • Camera: high sensitivity, high resolution scientific grade CCD camera with 2.0 megapixel resolution, extendable to 6.0 megapixels
  • Lens:5-75 f/1.2
  • Overhead Light Selector: White light, 365 nm UV, 254 nm UV
  • Flters: ethidium bromide, SYBR Green, SYBR Gold
  • Visible color stains: Coomassie, Silver
  • Allows to visualize chemiluminscent reactions
  • Manual lift platform, 3 emission filters, white light plate, overhead UV, white light and blue light
  • Transilluminator: Choice of UV transilluminator models
Learn More
UVP-EpiChemi3-Darkroom-Gel-Imaging-System-12255
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
New Brunswick Scientific Excella E25 Incubator Shaker

New Brunswick Scientific Excella E25 Incubator Shaker

Cambridge Scientific ID #'s: 24735, 24307

The E-25R Classic Refrigerated Incubator Shakers are large capacity shakers utilizing a UniCentric single eccentric counterbalanced drive to provide horizontal plane rotary motion in a 2.54 cm (1 in) circular orbit. A Proportional/Integral (PI) Microprocessor controller with instantaneous digital feedback controls the speed over a range of 50-400 rpm.   

 

Specification:

 

 

  • Shaking

 

    • Speed: 50-400 rpm
    • Control Accuracy: ± 1 rpm
    • Indication: 3-digit LED, displayed in 1 rpm increments
    • Stroke/Orbit: 2.54 cm (1 in)

 

  • Temperature

 

    • Range: 15°C below ambient temperature* (min. 4°C) to 60°C
    • Control Accuracy: ± 0.1°C @ 37°C
    • Indication: 3-digit LED, displayed in 0.1°C increments
  • Ambient Operating Environment: 10 - 35°C, 20 to 80% relative humidity, non-condensing
  • Refrigerant: R-134A
  • Alarms: Visible and audible warning indication when speed deviates more than 5 rpm, and temperature more than 1°C from setpoints, and when timer has expired.
  • Timer: 0.1 to 99.9 hours. Shuts off agitation at end of period. Can be deactivated for continuous operation.
  • Automatic Restart: Automatic restart after power is restored. Setpoints and operating status are retained in memory during power interruption.
  • Drive interrupt: Automatic drive-interrupt when cover is opened.
  • Platform: 76 x 46 cm (30 x 18 in)
  • Overall Dimensions (W x D x H): 127 x 77 x 85 cm (50 x 30.5 x 41.7 in)
  • Chamber Dimensions (W x D x H): 85 x 58 x 48 cm clearance above platform (33.5 x 23 x 19 in)
  • Net Weight: 204.5 kg (450 lb)
  • Gross Weight: 281 kg (480 lb)
Learn More
New-Brunswick-Scientific-Excella-E25-Incubator-Shaker-24735
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Fisher Scientific FB15012 Vortexer

Fisher Scientific FB15012 Vortexer

Cambridge ID #: 21796
  • Fisher Scientific FB15012 TopMix Vortex Mixer with optional microplate holder
  • Continuous or Touch operated
  • Max RPM 3,000
  • Supplied with 2 attachements (Cup for test tubes and microplate holder)
  • Serial# 139312
  • Dims 22cm (D) x 18cm (W) x 9cm (H)
  • Learn More
    Fisher-Scientific-FB15012-Vortexer-21796
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent G1315B HPLC Diode Array Detector

    Agilent G1315B HPLC Diode Array Detector

    Cambridge ID #: 24427

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-G1315B-HPLC-Diode-Array-Detector-24427
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Axon GenePix 4000B MicroArray Scanner

    Axon GenePix 4000B MicroArray Scanner

    Cambridge ID #: 23471

    Includes:

    • Computer w/ GenePix Pro -  MicroArray Acquisition & Analysis Software
    • Flat Panel Monitor
    • All Necessary Cords, Cables
    • Manual

     

    Features:

    • Speed. Unlike most commercially available microarray scanners, the GenePix 4000B Microarray Scanner acquires data at two wavelengths simultaneously. This means drastically reduced scan times and hence greater workflow efficiency. Apart from superior speed, simultaneous scanning eliminates potential errors associated with aligning two separately scanned images, and provides real-time access to data as they are acquired.
    • Add Reliability to Your Research. The performance calibration standards that come with your GenePix 4000B Microarray Scanner allow you to check the performance when you receive your scanner and at any time in the future. GenePix Pro Acquisition and Analysis Software includes one-touch calibration to restore any GenePix scanner to benchmark performance. You can rest assured knowing the signals you generate today are the same as a couple of years ago and in the future.
    • Automate Your Workflow. With automated photomultiplier (PMT) balancing. The fully integrated GenePix Pro Acquisition and Analysis Software, controls the GenePix 4000B Microarray Scanner and can automatically evaluate the required PMT gain values, for fast and easy optimization of signal intensity and channel balance. The GenePix 4000B Microarray Scanner then acquires data at your selected resolution between 5-100 micron, allowing the adjustment of image resolution and file size for each experiment.
    • Get More Published. For over 10 years and close to 6000 literature references, the GenePix 4000B Microarray Scanner has expanded the overall sample compatibility, with user-adjustable focus offset and laser power settings. This allows proper imaging of slides with either a raised surface, as with membrane-coated glass, or a recessed surface, as in embedded arrays.

     

    Performance Specifications

    • Sample type: Standard microscope slide (1" x 3", 25 x 75 mm or 26 x 76 mm)
    • Scan area: Adjustable, 22 x 71.5 mm max.
    • Excitation: 532 nm and 635 nm solid-state lasers
    • Laser power settings: User-selectable 100%, 33% or 10% laser power
    • Emission filters: Two, optimized for Cy3 and Cy5 or spectrally similar dyes
    • Detection: Dual photomultipliers (PMTs), automatic and manual gain adjustment
    • Focus offset: Adjustable between -50 and +200 μm (5 μm increments)
    • Optics: Non-confocal
    • Scanning method: Simultaneous, 2-channel
    • Scan time:5 minutes for both channels, 10 μm resolution, full scan area
    • Pixel resolution: Adjustable from 5-100 μm
    • Digital resolution: 16-bit
    • Dynamic range: Four orders of magnitude at SNR > 3
    • Image type: Single- or multi-image TIFF
    • Barcode reading: Image-based software barcode reader

     

    General Specifications

    • Dimensions (in.):5 (W) x 8.0 (H) x 17.5 (D)
    • Dimensions (cm): 34 (W) x 20 (H) x 44 (D)
    • Weight: 45 lbs. (20 kg)
    • Power supply: 110/220V universal
    • Genomics: Directed at the genome sequence itself, microarrays have been used to identify novel genes, binding sites of transcription factors, changes in DNA copy number, and variations from a baseline sequence, such as in emerging strains of pathogens or complex mutations in disease-causing human genes.
    Learn More
    Axon-GenePix-4000B-MicroArray-Scanner-23471
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Bio-Rad GS-800 Densitometer

    Bio-Rad GS-800 Densitometer

    Cambridge Scientific ID #'s: 21068, 20944

    The GS-800 calibrated densitometer offers superior accuracy, sensitivity, and data reproducibility. It automatically self-calibrates the optical density to optimize detection.Unlike laser densitometer systems, the GS-800 calibrated densitometer has both transmittance and true reflectance capabilities that allow accurate scans of both transparent and opaque samples. The advantage of true reflectance scanning is accurate detection and analysis of molecules on the surface of membranes, rather than molecules distributed throughout the membrane matrix.

    Specifications:

    • Wavelength: 400-750 nm
    • Absorbance Range:0 - 3 OD (transmissive), 0 - 2 OD (reflective)
    • Scanning Area: 29 x 40 cm (transmissive), 30 x 40 cm (reflective)
    • Sampling Rate:800 x 1600 dpi
    • Pixel Density:12 bit
    • Dimensions: 3 x 62.6 x 19.3 cm
    • Weight:8 kg
    Learn More
    Bio-Rad-GS-800-Densitometer-21068
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Millipore Guava easyCyte HT Flow Cytometer

    Millipore Guava easyCyte HT Flow Cytometer

    Cambridge Scientific ID #'s: 25074, 23268

    "The Millipore Guava EasyCyte HT offers sample handling formats for both tubes and 96-well plates, direct sampling using patented microcapillary system, and a user-friendly, versatile software. EasyCyte instruments are also compatible with many fluorochromes and fluorescent reagents.

    Specifications:

    Operating temperature: 16°–35°C (60°–95°F)

    Operating humidity: 10–90% relative humidity (non-condensing)

    Power: 100–240 VAC, 50/60 Hz, 120W

    Dimensions: 21 x 24 x 12 inches

    Weight: 71lb

    Detection: 5 colors including forward scatter

    Laser: blue 488 nm (50mW)

    Flow cell dimension: standard square capillary with ID of 100 µm

    Pump: 7 µL/min to 36 µL/min

    Sample flow rate: positive displacement

    Waste and cleaning vials: 30-mL glass vial with screw top

    Waste generation: typically <40 mL in 8 hours of continuous use

    Dead volume: 50 µL (for 96-well microplate); 75 µL (for 0.5-mL microcentrifuge tubes)

    Sample concentration: final particle concentration of 104 to 5 x 105 particles/ml

    Sample requirement: for accurate results (up to 2.5 x 106 beads/mL for the RapidQuant Assay) as few as 2,000 cells/test; typically 25,000-100,000 cells/test, depending on the assay

    Data management: Output data file formats - (1) binary data storage in FCS 3.0 format; (2) spreadsheet results file in CSV format"

    Learn More
    Millipore-Guava-easyCyte-HT-Flow-Cytometer-25074
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Rainin HPXL Solvent Delivery SystemImage Coming Soon

    Rainin HPXL Solvent Delivery System

    Cambridge Scientific ID #'s: 11708, 11709

    Description:

    The Rainin HPXL Solvent Delivery System consists of two binary pump gradient liquid chromatographic systems. One of the systems uses biocompatible (titanium) pump heads, injection valve and mixer. Two detectors are available: a single (variable) wavelength high sensitivity UV/Visible detector and a dual wavelength UV/Vis detector. A 900 nanoliter flow cell is available for the dual wavelength detector for low flow applications.

    Learn More
    Rainin-HPXL-Solvent-Delivery-System-11708
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Andor Technology iKon-M PV Inspector Series Back Illuminated CCD, Deep Depletion with fringe *NEW* Microscope Camera

    Andor Technology iKon-M PV Inspector Series Back Illuminated CCD, Deep Depletion with fringe *NEW* Microscope Camera

    Cambridge ID #: 16355

    Andor’s iKon-M 934 series cameras are designed to offer the ultimate in high-sensitivity, low noise performance, ideal for demanding imaging applications. These high resolution 1024 x 1024 CCD cameras boast up to 95% QEmax, high dynamic range, 13 μm pixels and exceptionally low readout noise. The iKon-M benefits from negligible dark current with industry-leading thermoelectric cooling down to -100°C. The ‘Deep Depletion’ sensor option offers ultimate performance for NIR applications, the new Dual AR coating extends the QE performance significantly across the UV/visible region of the spectrum for the broadest possible spectral coverage from one sensor. Fringe Suppression Technology radically minimizes etaloning effects in the NIR. Rapid vertical shifts combined with fast kinetics acquisition mode, comprehensive trigger modes and custom coated wedge window options, render the deep Depletion models ideal for NIR

    optimized Bose Einstein Condensation applications.

     

    Features and Benefits:

    • Extended range Dual-AR option: Superior UV-NIR broadband back-illuminated QE
    • TE cooling to -100°C: Critical for elimination of dark current
    • Fringe Suppression Technology: NIR etaloning greatly reduced (BR-DD and BEX2-DD sensor types)
    • Up to 5 MHz pixel readout: High frame rates achievable
    • Ultra low noise readout: Intelligent low-noise electronics offer the most ‘silent’ system noise performance available
    • UltraVac: Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year
    • 13 x 13 μm pixel size: Optimal balance of dynamic range and resolution
    • Integrated shutter: C-mount shutter as standard. Closed during readout to avoid vertical smear
    • Cropped Sensor Mode: Specialized acquisition mode for continuous imaging with fastest possible temporal resolution
    • Enhanced Baseline Clamp: Quantitative accuracy of dynamic measurements
    • USB 2.0 connection: Simple Plug & Play connection
    • Integrated in EPICS: Platform is fully integrated into the EPICS control software

     

    Specifications:

    • Active pixels: 1024 x 1024
    • Sensor size: 13.3 x 13.3 mm
    • Pixel size (W x H): 13 μm x 13 μm
    • Active area pixel well depth: 100,000 e- (130,000 e- for BR-DD and BEX2-DD models)
    • Pixel readout rates (MHz): 5, 3, 1, 0.05
    • Read noise: 2.9 e-
    • Maximum cooling: -100°C
    • Frame rate: 4.4 fps (full frame)
    • System window type: UV-grade fused silica, ‘Broadband VUV-NIR’, wedged
    • Interface: USB 2.0
    Learn More
    Andor-Technology-iKon-M-PV-Inspector-Series-Back-Illuminated-CCD,-Deep-Depletion-with-fringe-*NEW*-Microscope-Camera-16355
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Andor Technology iXon Life 888 EMCCD *NEW* Microscope Camera

    Andor Technology iXon Life 888 EMCCD *NEW* Microscope Camera

    Cambridge ID #: 16888

    Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

    Specifications:

    • Sensor Type: Back Illuminated, standard AR coated
    • Active pixels (H x V): 1024 x 1024
    • Pixel Size (H x V: µm): 13 x 13
    • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
    • Active Area Pixel Well Depth (e-): 80,000 180,000
    • Pixel Readout Rate
    • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 30 MHz•3 -55ºC
    • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 30 MHz•3 -65ºC
    • Thermostatic Precision: ± 0.01°C
    • Triggering: Internal, External, External Start, External Exposure, Software Trigger
    • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
    • Digitization: 16-bit (at all speeds)
    • PC Interface: USB 3.0•12
    • Lens Mount: C-mount
    • Dark Current and Background Events•4,5:
    • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
    • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.005
    • Active Area Pixel Well Depth: 80,000 e-
    • Gain Register Pixel Well Depth•6: 730,000 e-
    • Read noise (e-) •7: <1
    • Linearity•8: Better than 99.9%
    • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
    • Timestamp accuracy: 10 ns

     

     

     

     

     

    Learn More
    Andor-Technology-iXon-Life-888-EMCCD-*NEW*-Microscope-Camera-16888
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Andor Technology iXon Life 897 EMCCD *NEW* Microscope Camera

    Andor Technology iXon Life 897 EMCCD *NEW* Microscope Camera

    Cambridge ID #: 16889

    Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

    Specifications:

    • Sensor Type: Back Illuminated, standard AR coated
    • Active pixels (H x V): 512 x 512
    • Pixel Size (H x V: µm): 16 x 16 μm
    • Image Area: 8.2 x 8.2 mm with 100% Fill Factor
    • Active Area Pixel Well Depth (e-): 80,000 180,000
    • Pixel Readout Rate
    • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 17 MHz•3 -70ºC
    • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 17 MHz•3 -80ºC
    • Thermostatic Precision: ± 0.01°C
    • Triggering: Internal, External, External Start, External Exposure, Software Trigger
    • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
    • Digitization: 16-bit (at all speeds)
    • PC Interface: USB 2.0
    • Lens Mount: C-mount
    • Dark Current and Background Events•4,5:
    • Dark Current (e- /pixel/sec) @ -80°C: 0.00030
    • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.0018
    • Active Area Pixel Well Depth: 180,000 e
    • Gain Register Pixel Well Depth•6: 800, 000 e
    • Read noise (e-) •7: <1
    • Linearity•8: Better than 99.9%
    • Vertical Clock Speed: 0.3 to 3.3 µs (user selectable)
    • Timestamp accuracy: 10 ns

     

     

     

     



     

     

     

     

     

    Learn More
    Andor-Technology-iXon-Life-897-EMCCD-*NEW*-Microscope-Camera-16889
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Andor Technology iXon Ultra 888 BVF USB3 EMCCD *NEW* Microscope Camera

    Andor Technology iXon Ultra 888 BVF USB3 EMCCD *NEW* Microscope Camera

    Cambridge ID #: 16875

    The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

    Specifications:

     

    • Sensor QE: Back-illuminated, standard AR coated with fringe suppression
    • Active Pixels: 1024 x 1024
    • Pixel Size: 13 x 13 μm
    • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
    • Pixel Readout Rate:
    • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
    • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
    • Thermostatic Precision: ± 0.01°C
    • Triggering: Internal, External, External Start, External Exposure, Software Trigger
    • System Window Type:
    • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
    • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
    • Digitization: 16-bit (at all speeds)
    • PC Interface: USB 3.0•12
    • Lens Mount: C-mount
    • Direct Data: Access Camera Link 3-tap output
    • Dark Current and Background Events•4,5:
    • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
    • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
    • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
    • Active Area Pixel Well Depth: 80,000 e-
    • Gain Register Pixel Well Depth•76: 730,000 e-
    • Linearity•8: Better than 99.9%
    • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
    • Timestamp Accuracy: 10 ns

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Learn More
    Andor-Technology-iXon-Ultra-888-BVF-USB3-EMCCD-*NEW*-Microscope-Camera-16875
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Andor Technology iXon Ultra 888 EX USB3 EMCCD *NEW* Microscope Camera

    Andor Technology iXon Ultra 888 EX USB3 EMCCD *NEW* Microscope Camera

    Cambridge ID #: 16874

    The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

    Specifications:

     

    • Sensor QE: Back-illuminated, EX2 dual AR coated
    • Active Pixels: 1024 x 1024
    • Pixel Size: 13 x 13 μm
    • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
    • Pixel Readout Rate
    • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
    • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
    • Thermostatic Precision: ± 0.01°C
    • Triggering: Internal, External, External Start, External Exposure, Software Trigger
    • System Window Type:
    • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
    • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
    • Digitization: 16-bit (at all speeds)
    • PC Interface: USB 3.0•12
    • Lens Mount: C-mount
    • Direct Data: Access Camera Link 3-tap output
    • Dark Current and Background Events•4,5:
    • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
    • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
    • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
    • Active Area Pixel Well Depth: 80,000 e-
    • Gain Register Pixel Well Depth•76: 730,000 e-
    • Linearity•8: Better than 99.9%
    • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
    • Timestamp Accuracy: 10 ns

     

     

     

     

     

     

     

     

     

     

     

     

    Learn More
    Andor-Technology-iXon-Ultra-888-EX-USB3-EMCCD-*NEW*-Microscope-Camera-16874
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping