Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Microprocessor Pump Drive: 1-15 of 439

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Cole Parmer Masterflex Console Drive Peristaltic Pump

Cole Parmer Masterflex Console Drive Peristaltic Pump

Cambridge ID #: 11922

Economical and easy-to-use analog drives offer precise speed control—ideal for metering applications. Contains a reversible motor to purge tubing before and after pumping fluid and a  separate single turn speed control.

Specifications:

  • Speed Range: 6 - 600 rpm
  • Speed Control:+/- 2%
  • Maximum Flow Rate:3400 mL/min
  • Minimum Flow Rate:36 mL/min
  • Dimensions: 5 x 7 x 7 in
  • Power Requirements:90 to 130VAC, 1.5A
  • Motor hp: 1/10
Learn More
Cole-Parmer-Masterflex-Console-Drive-Peristaltic-Pump-11922
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex Console Drive 7520-40 Peristaltic Pump

Cole Parmer Masterflex Console Drive 7520-40 Peristaltic Pump

Cambridge ID #: 14916

Economical and easy-to-use analog drives offer precise speed control—ideal for metering applications. Contains a reversible motor to purge tubing before and after pumping fluid and a  separate single turn speed control.

Specifications:

  • Speed Range: 6 - 600 rpm
  • Speed Control:+/- 2%
  • Maximum Flow Rate:3400 mL/min
  • Minimum Flow Rate:36 mL/min
  • Dimensions: 5 x 7 x 7 in
  • Power Requirements:90 to 130VAC, 1.5A
  • Motor hp: 1/10
Learn More
Cole-Parmer-Masterflex-Console-Drive-7520-40-Peristaltic-Pump-14916
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex Console Drive 77521-40 Peristaltic Pump

Cole Parmer Masterflex Console Drive 77521-40 Peristaltic Pump

Cambridge ID #: 18850

Economical and easy-to-use analog drives offer precise speed control—ideal for metering applications. Contains a reversible motor to purge tubing before and after pumping fluid and a  separate single turn speed control.

Specifications:

  • Speed Range: 6 - 600 rpm
  • Speed Control:+/- 2%
  • Maximum Flow Rate:3400 mL/min
  • Minimum Flow Rate:36 mL/min
  • Dimensions: 5 x 7 x 7 in
  • Power Requirements:90 to 130VAC, 1.5A
  • Motor hp: 1/10
Learn More
Cole-Parmer-Masterflex-Console-Drive-77521-40-Peristaltic-Pump-18850
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Electron Accela 600 Pump HPLC Quaternary Pump

Thermo Electron Accela 600 Pump HPLC Quaternary Pump

Cambridge ID #: 11202

Specifications:

  • Flow rate range: 1 to 5000 μL/min
  • Backpressure range 0 to 600 bar (8702 psi)
  • Residual pulsation < 2 bar Amplitude
  • Flow rate accuracy ±0.5% or 1 μL/min, whichever is greater
  • Gradient composition accuracy ±0.5% absolute
  • Gradient resolution 1% from 0 to 100%
  • Firmware version (November 2010) 23.67 e
  • Gradient composition range 0 to 100% from up to 4 independent feed channels employing 2 of them at the same time
  • Delay volume 90 μL (LDA) + 65 μL (static mixer)
Learn More
Thermo-Electron-Accela-600-Pump-HPLC-Quaternary-Pump-11202
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Harvard Apparatus Pump 11 Syringe Pump

Harvard Apparatus Pump 11 Syringe Pump

Cambridge Scientific ID #'s: 11359, 18704, 13813, 13812

Features:

  • Single Syringe Holder
  • Flow Rate Maximum: 26.55 ml/min wih 50/60 ml syringe.4 ml/hr
  • Flow Rate Minimum: 0.0014 µl/hr with 0.5 µl syringe
  • Syringe Size Maximum: 50/60 ml
  • Syringe Size Minimum: 10 ul
  • Voltage Range: 95-240 VAC, 50/ 60 Hz
Learn More
Harvard-Apparatus-Pump-11-Syringe-Pump-11359
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
KD Scientific Syringe Pump Syringe PumpImage Coming Soon

KD Scientific Syringe Pump Syringe Pump

Cambridge ID #: 7637
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
KD-Scientific-Syringe-Pump-Syringe-Pump-7637
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Variable Speed Pump Electrophoresis Pump

Bio-Rad Variable Speed Pump Electrophoresis Pump

Cambridge ID #: 13115
  • 120 V, pulsed field gel electrophoresis pump, for use with any CHEF system
  • Learn More
    Bio-Rad-Variable-Speed-Pump-Electrophoresis-Pump-13115
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Jungwoo Electric 008N40048AE Vacuum PumpImage Coming Soon

    Jungwoo Electric 008N40048AE Vacuum Pump

    Cambridge ID #: 10320
  • Jungwoo Electric 008N40048AE Vacuum Pump
  • Learn More
    Jungwoo-Electric-008N40048AE-Vacuum-Pump-10320
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Velocity 11 06118-001 Peristaltic PumpImage Coming Soon

    Velocity 11 06118-001 Peristaltic Pump

    Cambridge ID #: 13296

    The Fisher Scientific Dry Bath Incubators offer exceptional temperature control and uniformity in addition to a powder coated steel body to provide durability for demanding applications.

    Specifications:

    • Temperature Range: 5 - 130 °C
    • Temperature Stability: +/-1.5 °C
    • Temperature Uniformity: +/-0.5 °C
    • Power Requirements: 120V, 50/60Hz
    Learn More
    Velocity-11-06118-001-Peristaltic-Pump-13296
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Franklin Electric 1091045400 Vacuum PumpImage Coming Soon

    Franklin Electric 1091045400 Vacuum Pump

    Cambridge ID #: 10962
  • 3/4 HP
  • Max Amb: 40°C
  • RPM: 1725/1425
  • Learn More
    Franklin-Electric-1091045400-Vacuum-Pump-10962
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    KNF 10Tor Vacuum PumpImage Coming Soon

    KNF 10Tor Vacuum Pump

    Cambridge ID #: 4036
  • 2-Stage.
  • Learn More
    KNF-10Tor-Vacuum-Pump-4036
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Agilent 1100 Series - G1310A HPLC Isocratic Pump

    Cambridge ID #: 14776

    The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

     

     Features:

    • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
    • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
    • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
    • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

     

    Specifications:

    • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
    • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
    • Flow range: 2 – 10.0 ml/min
    • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
    • Operating voltage: 230V

     

    Learn More
    Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Agilent 1100 Series - G1311A HPLC Quaternary Pump

    Cambridge Scientific ID #'s: 14613, 16067, 19164, 16337, 9165, 16848, 13906, 14496, 15507, 16000, 16142

    The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control. 

     

    Specifications:

    • Configurable Flow Range: 0.001 – 10ml/min – in 0.001ml/min increments
    • Flow Range: 0.2 – 10.0 ml/min
    • Recommended pH Range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
    • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
    Learn More
    Agilent-1100-Series---G1311A-HPLC-Quaternary-Pump-14613
    By clicking below we can further assist you with your inquiry. Inquire 11 In Stock Worldwide Shipping
    Agilent 1100 Series - G1312A HPLC Binary Pump

    Agilent 1100 Series - G1312A HPLC Binary Pump

    Cambridge Scientific ID #'s: 15626, 7526, 17475, 13985, 16317, 15936, 16119, 12811, 19156, 16034, 8571, 9300, 19155, 13406, 12452

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
    By clicking below we can further assist you with your inquiry. Inquire 15 In Stock Worldwide Shipping
    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cambridge ID #: 11053

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping