Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Millipore: 1-9 of 9

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Millipore Direct-Q 3 UV *NEW* Water Purification

Millipore Direct-Q 3 UV *NEW* Water Purification

Cambridge ID #: 20874

Features:

Direct-Q® systems deliver both pure and ultrapure water directly from tap for use with a wide variety of applications in your lab. Direct-Q® systems can be equipped with integrated or external reservoirs and are designed for under bench-, bench- or wall-mounting. The system's built-in 185nm UV lamp reduces the levels of organics for critical applications. You can fine-tune your ultrapure water quality to match your applications using Application specific point-of-use polishers to remove specific contaminants such as bacteria, particulates, pyrogen, nucleases, endocrine disruptors or volatile organic compounds.

 

 

Specifications:

  • Daily Product Water Usage: 40 L/Day
  • Feed Water Nature: Potable Tap Water
  • Product Water Particulates: < 1 unit/mL (particulates >0.22 μm - with Millipak® or Biopak® point-of-use filters)
  • Water Quality: Type 1, Type 3

 

Learn More
Millipore-Direct-Q-3-UV-*NEW*-Water-Purification-20874
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore Direct-Q 5 UV *NEW* Water Purification

Millipore Direct-Q 5 UV *NEW* Water Purification

Cambridge ID #: 20875

Features:

Direct-Q® systems deliver both pure and ultrapure water directly from tap for use with a wide variety of applications in your lab. Direct-Q® systems can be equipped with integrated or external reservoirs and are designed for under bench-, bench- or wall-mounting. The system's built-in 185nm UV lamp reduces the levels of organics for critical applications. You can fine-tune your ultrapure water quality to match your applications using Application specific point-of-use polishers to remove specific contaminants such as bacteria, particulates, pyrogen, nucleases, endocrine disruptors or volatile organic compounds. The system's versatile remote dispenser helps you stay focused on your work by providing ultrapure water delivery where you need it. The remote dispenser can be placed up to two meters from the Direct-Q® system, and are available in free-standing or wall-mounted models.  

 

Specifications:

  • Feed Water Nature: Potable Tap Water
  • Flow Rate: 5 Liters per hour
  • Daily Product Water Usage  : 60L/day
  • Dimensions: 15 x 11.4 x 21.3 (DxWxH)  
  • Product Water Resistivity: 
    • Ultrapure water: 18.2 MegOhm-cm
    • Product Water TOC: <5 ppb
    • Voltage: 100-240 V/50-60 Hz
    • Product Water Instant Delivery Rate: > 0.5 L/min

 

Learn More
Millipore-Direct-Q-5-UV-*NEW*-Water-Purification-20875
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore Direct-Q 8 UV *NEW* Water Purification

Millipore Direct-Q 8 UV *NEW* Water Purification

Cambridge ID #: 20873

Features:

Direct-Q® systems deliver both pure and ultrapure water directly from tap for use with a wide variety of applications in your lab. Direct-Q® systems can be equipped with integrated or external reservoirs and are designed for under bench-, bench- or wall-mounting. The system's built-in 185nm UV lamp reduces the levels of organics for critical applications. You can fine-tune your ultrapure water quality to match your applications using Application specific point-of-use polishers to remove specific contaminants such as bacteria, particulates, pyrogen, nucleases, endocrine disruptors or volatile organic compounds. The system's versatile remote dispenser helps you stay focused on your work by providing ultrapure water delivery where you need it. The remote dispenser can be placed up to two meters from the Direct-Q® system, and are available in free-standing or wall-mounted models.

 

Specifications:

  • Daily Product Water Usage :160 L/Day
  • Feed Water Nature :Potable Tap Water
  • Product Water Particulates: < 1 unit/mL (particulates >0.22 μm - with Millipak® or Biopak® point-of-use filters)
  • Water Quality: Type 1, Type 3

 

Learn More
Millipore-Direct-Q-8-UV-*NEW*-Water-Purification-20873
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore Guava easyCyte HT Flow Cytometer

Millipore Guava easyCyte HT Flow Cytometer

Cambridge ID #: 23268
  • The Millipore Guava EasyCyte HT offers sample handling formats for both tubes and 96-well plates, direct sampling using patented microcapillary system, and a user-friendly, versatile software. EasyCyte instruments are also compatible with many fluorochromes and fluorescent reagents.
  • Specifications:
  • Operating temperature: 16°"“35°C (60°"“95°F)
  • Operating humidity: 10"“90% relative humidity (non-condensing)
  • Power: 100"“240 VAC, 50/60 Hz, 120W
  • Dimensions: 21 x 24 x 12 inches
  • Weight: 71lb
  • Detection: 5 colors including forward scatter
  • Laser: blue 488 nm (50mW)
  • Flow cell dimension: standard square capillary with ID of 100 µm
  • Pump: 7 µL/min to 36 µL/min
  • Sample flow rate: positive displacement
  • Waste and cleaning vials: 30-mL glass vial with screw top
  • Waste generation: typically <40 mL in 8 hours of continuous use
  • Dead volume: 50 µL (for 96-well microplate); 75 µL (for 0.5-mL microcentrifuge tubes)
  • Sample concentration: final particle concentration of 104 to 5 x 105 particles/ml
  • Sample requirement: for accurate results (up to 2.5 x 106 beads/mL for the RapidQuant Assay) as few as 2,000 cells/test; typically 25,000-100,000 cells/test, depending on the assay
  • Data management: Output data file formats - (1) binary data storage in FCS 3.0 format; (2) spreadsheet results file in CSV format
  • Learn More
    Millipore-Guava-easyCyte-HT-Flow-Cytometer-23268
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Millipore Milli-Q Gradient A10 Water Purification

    Millipore Milli-Q Gradient A10 Water Purification

    Cambridge ID #: 13718

    Specifications:

    Flow rate:

    • 1.3 – 1.7 LPM with Millipak® Express 20
    • 1.3 – 1.7 LPM with BioPak

    Resistivity:

    • Minimum 18.0 MΩ.cm @ 25°C
    • Typically 18.2 MΩ.cm @ 25°C

    Particles: ≤ 1/ml (particle size > 0.22 μm)

    Pyrogens: BioPak installed < 0.001 Eu/ml

    TOC: Maximum 5 ppb (this specification came from test conditions where a Milli-Q Gradient was fitted with a Q-Gard® 1 Purification Pack and a Quantum EX Ultrapure Cartridge and the feedwater came from a Millipore RiOs Water System. The feedwater TOC value was < 50 ppb). The TOC of the Milli-Q Product Water can vary as a function of the feedwater TOC.

    Micro-Organisms: ≤ 1 CFU/ml

    Weight:

    Milli-Q Gradient: Operating weight (wetted Q-Gard, Quantum and Millipak): 16 kg.

     

    • Milli-Q Gradient A10: Operating weight: 16.8 kg.

    Electrical: 

    The electrical requirements for a Milli-Q Gradient (or Milli-Q Gradient A10) are:

    • 120 VAC ± 10%, 50/60 Hz, 100 VA, 0.5 amp source, 2 amp Time Lag fuse used (ref. ZMQS6V0T1, MQP6V0T1, ZMQS6V001, ZMQP6V001).
    • 230 VAC ± 10%, 50/60 Hz. 0.26 amp source, 1 amp Time Lag fuse used (ref. ZMQS5V0T1, ZMQP5V0T1, ZMQS5V001, ZMQP5V001).
    • The source of electrical power should be within 1 meter of the Milli-Q. The source of electrical power must be earth grounded.

    Measurement Ranges for TOC, Resistivity, Conductivity and Temperature:

    • Resistivity Measurement Range: 2.4 – 18.2 MΩ.cm (compensated to a 25°C value)
    • Conductivity Measurement Range: 0.055 – 0.294 μS/cm
    • Temperature Measurement Range: 0 – 45°C (not the system temperature operating range)
    • TOC Measurement Range: 1 – 999 ppb
    Learn More
    Millipore-Milli-Q-Gradient-A10-Water-Purification-13718
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Millipore Milli-Q Synthesis A10 Water Purification

    Millipore Milli-Q Synthesis A10 Water Purification

    Cambridge ID #: 15882

    Specifications:

    Flow rate:

    • 1.3 – 1.7 LPM with Millipak® Express 20
    • 1.3 – 1.7 LPM with BioPak

    Resistivity:

    • Minimum 18.0 MΩ.cm @ 25°C
    • Typically 18.2 MΩ.cm @ 25°C

    Particles: ≤ 1/ml (particle size > 0.22 μm)

    Pyrogens: BioPak installed < 0.001 Eu/ml

    TOC: Maximum 5 ppb (this specification came from test conditions where a Milli-Q Gradient was fitted with a Q-Gard® 1 Purification Pack and a Quantum EX Ultrapure Cartridge and the feedwater came from a Millipore RiOs Water System. The feedwater TOC value was < 50 ppb). The TOC of the Milli-Q Product Water can vary as a function of the feedwater TOC.

    Micro-Organisms: ≤ 1 CFU/ml

    Weight:

    Milli-Q Gradient: Operating weight (wetted Q-Gard, Quantum and Millipak): 16 kg.

     

    • Milli-Q Gradient A10: Operating weight: 16.8 kg.

    Electrical: 

    The electrical requirements for a Milli-Q Gradient (or Milli-Q Gradient A10) are:

    • 120 VAC ± 10%, 50/60 Hz, 100 VA, 0.5 amp source, 2 amp Time Lag fuse used (ref. ZMQS6V0T1, MQP6V0T1, ZMQS6V001, ZMQP6V001).
    • 230 VAC ± 10%, 50/60 Hz. 0.26 amp source, 1 amp Time Lag fuse used (ref. ZMQS5V0T1, ZMQP5V0T1, ZMQS5V001, ZMQP5V001).
    • The source of electrical power should be within 1 meter of the Milli-Q. The source of electrical power must be earth grounded.

    Measurement Ranges for TOC, Resistivity, Conductivity and Temperature:

    • Resistivity Measurement Range: 2.4 – 18.2 MΩ.cm (compensated to a 25°C value)
    • Conductivity Measurement Range: 0.055 – 0.294 μS/cm
    • Temperature Measurement Range: 0 – 45°C (not the system temperature operating range)
    • TOC Measurement Range: 1 – 999 ppb
    Learn More
    Millipore-Milli-Q-Synthesis-A10-Water-Purification-15882
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Millipore Muse  Cell Analyzer

    Millipore Muse Cell Analyzer

    Cambridge ID #: 20133

    Features:

    The Muse Cell Analyzer delivers accurate assessments of cell health parameters, cell signaling activation pathways & immune status in just minutes, revolutionizing the way you analyze cells.

    Specifications:

    • Cell Number per Assay: User defined; cell concentrations of 10,000–500,000 cells/mL
    • Sample Format: Single loader
    • Sample Volume: 200 µL
    • Emission Max: Yellow: 28nm bandwidth at 576nm, Red: 30nm bandwidth at 680nm, Forward scatter = laser wavelength
    • Excitation Max: Green Laser (532nm)
    • Scatter: Forward
    • Throughput: Less than 2 minutes per sample
    • Dimensions 8.69” H  x 8.12” W x 11.11” L
    Learn More
    Millipore-Muse-Cell-Analyzer-20133
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Millipore SA 67120 Water Purification

    Millipore SA 67120 Water Purification

    Cambridge ID #: 22267
  • The Millipore Milli-Q Synthesis A-10 water purification system delivers type 1, ultrapure water for your applications thatÂ’s pyrogen and RNase free. Applications such as ELISA tests, electrophoresis gel make-up and serum-based cell and tissue culture media perpetration, affinity chromatography, and protein and nucleic acid isolation. The Synthesis system takes pretreated water (either through EDI, Reverse Osmosis, Distillation or Deionization, and pumps it through the Q-Guard cartridge, then passes the water under UV lights at two wavelengths, 185 and 254nm. Organic compounds are oxidized and bacteria is destroyed. The Quantum cartridge then filters out the trace ions and oxidation by products. Purified water is then sent through an ultrafiltration module, and finally through a filter membrane that removes any particles or bacteria greater than 0.22µm in size.
  • The Millipore Milli-q Synthesis A-10 includes a built in A-10 total organic carbon (TOC) monitor, high-precision resistivity meter, while providing complete monitoring of water quality throughout the process. As the process proceeds, the water quality and operation data is recorded in system memory. This Millipore water filter uses a backlit display to show resistivity and TOC Levels in addition to other system functions, for easy monitoring.
  • The Millipore Milli-q Synthesis A-10 has a flowrate of up to 1 liter per minute.
  • Learn More
    Millipore-SA-67120-Water-Purification-22267
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Millipore Waters 745 Data ModuleImage Coming Soon

    Millipore Waters 745 Data Module

    Cambridge ID #: 6485

    Data Module

    Learn More
    Millipore-Waters-745-Data-Module-6485
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping