Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Multichannel Interface: 1-15 of 144

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 35900E HPLC Interface

Agilent 35900E HPLC Interface

Cambridge Scientific ID #'s: 11228, 15239, 9312, 11227

Features:

  • Data buffering
  • Independent analog-to-digital (A/D) converters
  • Real-time control
  • Instrument control ports
  • Host communication
  • Front panel indicators that show run status, interface activity, etc.
  • Compatibility with Agilent data systems
  • External power adapter with 24V DC output
Learn More
Agilent-35900E-HPLC-Interface-11228
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Hewlett Packard 35900E HPLC Interface

Hewlett Packard 35900E HPLC Interface

Cambridge ID #: 16332

Features:

  • Data buffering
  • Independent analog-to-digital (A/D) converters
  • Real-time control
  • Instrument control ports
  • Host communication
  • Front panel indicators that show run status, interface activity, etc.
  • Compatibility with Agilent data systems
  • External power adapter with 24V DC output
Learn More
Hewlett-Packard-35900E-HPLC-Interface-16332
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge ID #: 17472

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-17472
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364B HPLC Fraction Collector

Agilent 1100 Series - G1364B HPLC Fraction Collector

Cambridge ID #: 18542

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364B-HPLC-Fraction-Collector-18542
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Heracell 150i CO2 IncubatorImage Coming Soon

Heracell 150i CO2 Incubator

Cambridge ID #: 11169

Description:

Protect valuable samples while optimizing cell growth. Thermo Scientific Heracell 150i CO2 Incubators with Stainless-Steel Chambers provide the ideal in-vitro environment. Clean, reliable and easy to use, they feature fast recovery characteristics and a convenient touchscreen user-interface.

Specifications:

  • Temperature Range: Ambient +3°C to 55°C
  • Disinfection Time: 90°C/9 hr. CO2
  • Concentration Range: 0 to 20%
  • Copper Lining
Learn More
Heracell-150i-CO2-Incubator-11169
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 2200 TapeStation Genetic Analyzer

Agilent 2200 TapeStation Genetic Analyzer

Cambridge ID #: 20637

Features:
8-well PCR tube strips or 96-well sample plates are available depending on sample throughput, bringing added flexibility.
Needle cartridges enable fast and simple needle exchange to ensure proper maintenance of the 2200 TapeStation system.
TapeStation Test Tape is available for troubleshooting and running System Diagnostics tests. The Tapes are reusable and expire after two years.

Specifications:

  • Input voltage: 12 V DC
  • Power consumption: 40 W (VA)
  • Current: 3 A Interface: USB cable (PC comms.)
  • Instrument Housing: UL94/VO rated flame retardant cast polyurethane
  • Dimensions: 400x 310x 310 mm
  • Weight: 12.5 kg
  • Power supply
    • Input voltage: 100 – 240 V AC
    • Input frequency: 50 – 60 Hz
    • Phase: 1
    • Current: 0.45 – 1.1 A
Learn More
Agilent-2200-TapeStation-Genetic-Analyzer-20637
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma 3140 CO2 Water Jacketed Incubator

Thermo Forma 3140 CO2 Water Jacketed Incubator

Cambridge Scientific ID #'s: 11942, 11944, 11943

Specifications:             

  • Capacity: 6.5 cu. ft. (184L)
  • CO2 Concentration Range: 0 to 20%
  • O2 Range: 1 to 20%
  • Relative Humidity: Ambient to 95% at 37°C
  • Humidity System: 3L stainless-steel pan
  • Temperature Range: Ambient +5°C to 55°C
  • Temperature Uniformity: ±0.2°C at 37°C
  • Chamber: Polished stainless-steel interior with coved corners
  • Interior D x W x H: 0 x 21.3 x 26.8 in. (50.8 x 54.1 x 68.1cm)
  • Shelving: Stainless steel
  • Exterior L x W x H: 25 x 26.0 x 39.5 in. (63.5 x 66.0 x 110.3cm)
  • Port(s): Chamber thru-wall access port with filter; RS-485 interface (optional)
  • Net Weight: 265 lb. (120.2kg)
  • Shipping Weight: 324 lb. (147kg)
Learn More
Thermo-Forma-3140-CO2-Water-Jacketed-Incubator-11942
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Fisher Scientific 4635 Shaker

Fisher Scientific 4635 Shaker

Cambridge ID #: 17848

 

Specifications:

 

Digital Port: One RS 232 C Interface

Learn More
Fisher-Scientific-4635-Shaker-17848
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BD BioScience Accuri C6 Flow Cytometer

BD BioScience Accuri C6 Flow Cytometer

Cambridge ID #: 18125

Features:

  • BD CSampler- 96 well plate and 24 tube rack automated sampler for BD Accuri C6 flow cytometer  
  • Blue and red laser
  • Two light scatter detectors
  • Optical filters such as FITC, PE, PerCP and APC
  • A compact optical design, fixed alignment, and pre-optimized detector settings make the system easier to use
  • Optional filters and the Selectable Laser Module expand the available fluorochrome combinations
  • Compact system and portable weight (13.6 Kg)
  • Intuitive interface of the software
  • Measures: 11 x 14.75 x 16.5 inches (H x W x D) (27.9 x 37.5 x 41.9 cm)
Learn More
BD-BioScience-Accuri-C6-Flow-Cytometer-18125
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BD BioScience Accuri C6 w/ csampler Flow Cytometer

BD BioScience Accuri C6 w/ csampler Flow Cytometer

Cambridge ID #: 15590

Features:

  • BD CSampler- 96 well plate and 24 tube rack automated sampler for BD Accuri C6 flow cytometer  
  • Blue and red laser
  • Two light scatter detectors
  • Optical filters such as FITC, PE, PerCP and APC
  • A compact optical design, fixed alignment, and pre-optimized detector settings make the system easier to use
  • Optional filters and the Selectable Laser Module expand the available fluorochrome combinations
  • Compact system and portable weight (13.6 Kg)
  • Intuitive interface of the software
  • Measures: 11 x 14.75 x 16.5 inches (H x W x D) (27.9 x 37.5 x 41.9 cm)
Learn More
BD-BioScience-Accuri-C6-w--csampler-Flow-Cytometer-15590
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Absorbance Reader

Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Absorbance Reader

Cambridge ID #: 18282

The SmartReader 96 comes complete with 4 popular filters: 405,450,492,630nm and twenty six additional filters are available separately to cover a full range from 340 to 750nm.  The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming. Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons.  Kinetic calculations can be performed by setting multiple readings. The SmartReader 96 is a convenient stand alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing.  A data port can be used for connecting a computer or basic printer.

 

Specification:

 

  • Control and Display: 7 inch touch screen (800 x 480 pixels)
  • Light Source: Quartz-halogen lamp 6V/10W
  • Wavelength Range: 340-750nm (405, 450, 492 and 630 nm filters included)
  • Half-Bandwidth of filter: 3~9nm
  • Readout Range: 0~4.000 Abs
  • Linearity (405nm): 0~2.000 Abs <+1% / 0~4.000 Abs <+2%
  • Precision: CV</= 0.2% (0-3) Abs ; CV</= 01.0% (3-4) Abs
  • Test Speed: <6 sec. for 96 well plate
  • Shaking: 3 modes - slow, medium, fast
  • User Interface: Integrated software and touch screen control
  • Storage: 200 programs; 100,000 test records
  • Ports: USB ports for PC, printer, mouse and flash drive
  • Dimensions: 295x440x225 mm (11.6 x 17 x 8.75 inches)
  • Weight: 10 kg
Learn More
Benchmark-Scientific-Accuris-SmartReader-96-MR9600-*NEW*-Microplate-Absorbance-Reader-18282
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Beckman Coulter AcT 10 Hematology/Chemistry AnalyzerImage Coming Soon

Beckman Coulter AcT 10 Hematology/Chemistry Analyzer

Cambridge ID #: 10921

Description:

The Beckman Coulter Ac·T 10 is an affordable, automated blood analyzer that provides whole blood and pre-dilute capabilities for the low-volume office labs and smaller laboratories.

Specifications:

  • Offers 10 parameters: WBC, RBC, Hgb, Hct, MCV, MCH, MCHC, Plt, Lymph # and Lymph %
  • One step sample processing with touch screen user interface
  • Automated probe wipe safely cleans the probe
  • Small 12 µL sample size permits whole blood analysis from both venous and capillary collections
  • Compact design lets you put the Ac·T Series anywhere
  • Minimum 50 samples per hour with STAT capability
  • Zero routine maintenance requirements and high system reliability help contain costs
Learn More
Beckman-Coulter-AcT-10-Hematology-Chemistry-Analyzer-10921
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Alliance 2690 HPLC System

Waters Alliance 2690 HPLC System

Cambridge ID #: 14605

This can be purchase with a number of optional detectors.
Description - The Waters 2695 features a large, easy-to-use LCD interface. Scientists can take advantage of the quick autostart and optimize their methods with a simple push of a button. Manage up to 120 industry standard vials with the built in autosampler. This reliable tool is a common work-horse in most analytical and contract labs. Built to meet labs rigorous requirements or routine analysis, this robust instrument is easily found in Pharmaceutical, Food Safety, R&D, Chemistry, Environmental or Quality Control labs. Simplify how you collect data, built-in compliance and validation features. The Empower software is capable of automating method development, archiving methods and customizing data reports.

The components can be customized to your needs.

You can get the system with any of the detectors, as well as an optional Computer.

  • 996 PDA Detector
  • 2996  PDA Detector
  • 2998 PDA Detector
  • 2487 UV detector
  • 2489 UV Detector
  • 2475 FLD detector:
  • Waters 2410 Refractive Index Detector:
  • Computer Loaded with Empowers 2 Software
Learn More
Waters-Alliance-2690-HPLC-System-14605
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping