Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Spectrometers / Spectrophotometers ranging from Spectrofluorometer, Fluorescence, Atomic Absorption (AA), ICP, to UV / Vis / NIR Spectrometers and Microplate. Some of our popular manufacturers include Beckman, Perkin Elmer, HP, Hitachi, Varian and Bio-Tek. We have one of the largest inventories of Mass Spectrometers available. We also offer service contracts, installation and training. Browse our inventory of used mass spec products below.

Nir Spectrometer: 1-15 of 39

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Bran Luebbe InfraProver II NIR Spectrometer

Bran Luebbe InfraProver II NIR Spectrometer

Cambridge ID #: 13370

Description: The DO308 drying oven is ideal for accurate water determination of solid or viscous samples like:

  • Substances that release water only at elevated temperatures such as plastics in powder or granular form
  • Substances that cause side reactions with Karl Fischer reagent such as oxidizing inorganic salts
  • Substances that cause problems in the titration vessel due to their consistency such as fibrous or pasty substances
  • Substances that are poorly soluble or insoluble such as wool, dough, tar or coal

Specifications:

  • Temperature range: 40 - 300 °C
  • Temperature accuracy: ±5 °C (@300°C)
  • Footprint housing: 256 x 180 mm
  • Dimensions overall: 500 x 220 mm
  • Voltage (auto selection): 100 ... 230 VAC   
  • Max. power consumption: 450 W
  • Height: 390 mm
  • Weight: 9.1 kg

Features and Benefits

  • Easy and fast manual handling - Easy handling for left and right handed operators. Sample exchange and sample transport into the heated zone of the oven is provided for by the simple transport system with a magnetic guide rod attached to the glass sample boat.
  • Equilibrium conditions are quickly reached - The cold and the hot zone can be purged separately with dry carrier gas using a stopcock. Ambient moisture introduced during sample exchange or addition via the sleeve opening is quickly carried away. Therefore, a stable drift is reached within a short period of time.
  • Enhanced operational safety - There is no need to remove the transfer tube from the titration cell after switching off the oven; just open the stopcock to avoid contamination of the oven due to underpressure. Different temperature ranges can be pre-programmed in one cycle. Safety is further improved by automatic shut down after the analysis is completed.
  • Ready for use - All necessary parts including the drying unit with gas flow measurement are part of the standard delivery. If purging with dry air is desired, an optional air pump is available.
Learn More
Bran-Luebbe-InfraProver-II-NIR-Spectrometer-13370
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Buchi NIRFlex N-500 FT-NIR Spectrophotometer

Buchi NIRFlex N-500 FT-NIR Spectrophotometer

Cambridge ID #: 13203

Description: With its dedicated operator interchangeable measurement cells to accommodate many different sample types, the NIRFlex N-500 is a uniquely, flexible FT-NIR Spectrometer. Its Fourier Transform polarization technology guarantees the same superior performance across different environmental conditions; from laboratory to warehouse.

 

Specifications:

 

  • Dimensions (W x D x H): 350 x 250 x 450 mm
  • Spectral range: 800 - 2500 nm (if not specified differently for measuring cell)
  • Resolution: 8 cm−1 (with boxcar apodization)
  • Type of interferometer: Polarization interferometer with TeO2 wedges
  • Wavenumber accuracy: ± 0.2 cm−1 (measured with HF gas cell at an ambient temperature of 25℃ ± 5℃)
  • Signal-to-noise ratio: 10000 (peak-to-peak noise of a linear corrected baseline)
  • Number of scans/sec.: 2 - 4 (depends on resolution)
  • Type of lamp/lifetime lamp (MTBF): Tungsten halogen lamp / 12000 h (2 x 6000 h)
  • Type of laser: 12 VDC HeNe, wavelength at 632.992 nm
  • Analog digital converter: 24 bit
  • Electric power supply: 100 - 230 VAC ± 10%, 50/60 Hz, 350 W

 

  • Ethernet connection: 100 Mbit/s
Learn More
Buchi-NIRFlex-N-500-FT-NIR-Spectrophotometer-13203
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 3200 Mass Spectrometer w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 3200 Mass Spectrometer w/ Shimadzu Prominence LC-20AD UFLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 14837

Includes Installation and One Year Warranty (Preventative Maintenance at 6 months)

Method Development and Training also Available

 

Includes:

  • AB Sciex API 3200 Mass Spectrometer LC/MS/MS
  • Windows 7 Computer loaded w/ Analyst Software 1.5
  • Turbo V-Spray ESI
  • Vacuum pump
  • Shimadzu Prominence 20 UFLC  Shimadzu
  • Shimadzu DGU-20A3 Degasser
  • (2)Shimadzu LC_20AD Liquid Chromatograph
  • Shimadzu CTO Column Oven
  • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Manuals


The API 3200 LC/MS/MS system is a fully-integrated triple quadrupole mass spectrometer built using premier technology that combines sensitivity and selectivity with ruggedness and reliability, all in an affordable, compact package

  • Innovative Turbo V ion source efficiently ionizes compounds over a wide range of flow rates, virtually eliminating cross-contamination, even with large sample loads
  • Patented LINAC collision cell technology delivers superior MS/MS performance allowing faster scan times without compromising sensitivity or mass spectral quality
  • Simplifies cross-platform methods transfer
  • Gives meaningful results from every experiment

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: TurboIonSpray, APCI, DuoSpray, PhotoSpray
  • Mass Accuracy / Stability: 0.1 Da over 8 hours and 0.15 Da over 24 hours
  • Mass Range: 5-1,700 (Quad); 50-1,700 (LIT)
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, TripleTrap
Learn More
AB-Sciex-API-3200-Mass-Spectrometer-w--Shimadzu-Prominence-LC-20AD-UFLC-and-CTC-Autosampler-LC-MS-MS--System-14837
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS  System

AB Sciex API 5000 LC/MS/MS Mass Spectrometer w/ Agilent 1100 HPLC and CTC Autosampler LC/MS/MS System

Cambridge ID #: 15382

Innovative QJet ion guide technology dramatically improves sensitivity by capturing and focusing more ions generated by the efficient TURBO V ion source. And the TURBO V source virtually eliminates cross-contamination, even with high-concentration samples.  New innovations in sensitivity like QJet ion guide technology make it possible to reach the lowest limits of detection. Combining QJet ion guide technology with the proven TURBO V ion source and a powerful new generation of Analyst software results in a robust, high throughput platform ideal for all phases of pharmaceutical development.

 

Includes:

  • AB Sciex API5000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Agilent 1100 HPLC and CTC Autosampler
    • G1322 Degasser
    • G1312A Binary Pump
    • G1316A Column Compartment
    • G1323A Game Boy
    • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse-counting channel electron multiplier (CEM) detector
  • Dynamic Range: 1 cps to 4 x 10(6) cps (pulse counting)
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.01% over the entire mass range
  • Mass Range: 5 – 1250 m/z
  • Scan Types:  Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Learn More
AB-Sciex-API-5000-LC-MS-MS-Mass-Spectrometer-w--Agilent-1100-HPLC-and-CTC-Autosampler-LC-MS-MS--System-15382
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer

Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer

Cambridge ID #: 20111

This Bruker BioSpin Avance III HD 400 High Performance Digital NMR Spectrometer was never installed and is unused in storage.

Specifications:

Frequency Controller & Signal Generation Unit

  • Basic configuration two channels frequency range each channel: 5–650 MHz each
  • Number of numerically controlled oscillators per channel: 3
  • Frequency resolution: < 0.005 Hz
  • Phase resolution: < 0.006º
  • Attenuation resolution / attenuation range: < 0.1 dB / 90 dB
  • Amplitude modulation: > 90 dB
  • Event time for digital setting of frequency, phase and amplitude, either individually or simultaneously: 25 ns
  • Memory per channel e.g. for pulse shaping: >8 Mbyte
  • Phase monotony over 90 dB amplitude setting range: < + / - 0.5 º

Timing Controller

  • Pulse sequence parameter calculation: in real time
  • Timing resolution / min. duration:5 / 25 ns
  • Output bus for events and devices: 96-bit

Communication Protocol

  • Fast Ethernet TCP / IP

Host Computer

  • Operating system: Windows 7

Receiver:

  • Bandwidth: up to 5 MHz

Digital Receiver Unit (DRU)

  • Effective dynamic range of digitizer
  • SW < 5 MHz: > 16-bit
  • SW < 1 MHz: > 18-bit
  • SW < 6 kHz: > 22-bit
  • Data compression / digital filtering: on the fly
  • Optimum real time digital filters: Yes

Quadrature Receiver (RXAD):

  • Quadrature image peaks with digital quadrature detection: 0%
Learn More
Bruker-BioSpin-Avance-III-HD-400-High-Performance-Digital-NMR-Spectrometer-20111
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee M7 *NEW* Mass Spectrometer

Persee M7 *NEW* Mass Spectrometer

Cambridge ID #: 21359

Features:

The M7 is an accurate, reliable and precise system which is suitable to both routine analysis and precision research applications. It can work with different manufacturers’ GC systems. The M7 MS can be widely used in food safety, environmental protection, material chemical industry, college education & research, life science, medicinal research, criminal investigation and many other fields. These applications benefit from its high performance, long service life and PERSEE’s strong after-sales service.

â—† User-friendly design makes the maintenance much easier 

â—† Compatible with different brand and models GC system

â—† The powerful GC-MS workstation is intuitive, simple and easy to operate. 

â—† The unique remote-control function enables powerful technical support 

â—† Competitive price and maintenance cost  

â—† Lifetime free workstation software update

 

Specifications:

  • GC&MS Interface: Capillary direct interface,independent temprature control, 50-300 ℃
  • Filament: Dual for EI,maximun emitting current 300uA
  • Ionization Enegy: 10-100 eV adjustable
  • Ion Source Temprature: Independent temprature control, maximum 350 ℃, adjustable
  • Mass Analyzer: High precision metal Molybdenum Quadrupole with pre-quadrupole
  • Backing Pump: Mechanical pump, geometric pumping speed 165 L/min
  • Turbo Pump: Turbo molecular pump, pumping speed 71 L/s, 260 L/s optional
  • Detector: Electron muliplier
  • Mass Range: 1.5-1050 u
  • Mass Accuracy: ±0.1 u
  • Resolution(R): Unit mass resolution
  • Mass Stability: ±0.1 u/48h
  • Maximum Scanning Speed: 11000 u/s
Learn More
Persee-M7-*NEW*-Mass-Spectrometer-21359
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1946D LC/MS System

Agilent 1100 Series - G1946D LC/MS System

Cambridge Scientific ID #'s: 10994, 12804

Includes Installation and One year Service Contract

 

Includes:

  • G1946D LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional Front end HPLC

Specifications

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed:
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1946D-LC-MS-System-10994
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Applied Biosystems 4800 Maldi TOF MS System

Applied Biosystems 4800 Maldi TOF MS System

Cambridge ID #: 10114

Includes Computer Loaded with 4000 Series Explorer Software Version 3.5.

 

The 4800 MALDI TOF/TOF Analyzer is a next-generation tandem time-of-flight MS/MS system that gives you all the advantages of MALDI in a flexible, easy-to-use, ultra-high-performance mass spectrometer.

  • OptiBeam™ on-axis laser provides ten times greater sensitivity to identify and quantitate low-abundance proteins in complex biological samples.
  • High-resolution precursor ion selection, enabled by the QuanTIS precursor selector, lets you detect and identify peptides that other systems miss and makes it easier for you to interpret your data by simplifying MS/MS spectra.
  • Ideal solution for high sensitivity putative protein biomarker identification and quantitation.
  • Fully supports LC MALDI workflows, allowing you to mass analyze without the time constraints of LC.
  • Simple experiment setup and fast mass analysis maximizes laboratory productivity.
  • High-energy, information-rich fragmentation patterns unavailable on other instrument platforms enable you to analyze carbohydrates, lipids, and other biological components.

Identify and Quantitate Putative Protein Biomarkers with Confidence
The 4800 MALDI TOF/TOF analyzer offers a new level of sensitivity for identifying and quantifying low abundance putative protein biomarkers. Fully compatible with novel iTRAQ™ reagents, the 4800 analyzer provides the most direct path to protein biomarker discovery. An expanded dynamic range enables high confidence identification and quantitation of low-level putative protein biomarkers in complex matrices. Powerful, easy-to-use GPS Explorer™ provides simplified, automated workflows to get you more quickly from discovery to validation.

The Only MALDI TOF/TOF™ Analyzer with On-Axis Laser Irradiation
The 4800 Analyzer is the only MALDI TOF/TOF mass spectrometer with on-axis laser irradiation, enabling sensitivity in the attamole range. Proprietary source modeling algorithms enable low ppm mass detection across the MALDI plate.

Expand Workflows, Increase Throughput
Get the speed, stability, and reliability you need to expand your current experimental workflows and add statistical significance to your experimental results. Quickly and easily increase throughput using automation features that allow you to rapidly and confidently collect the MS/MS spectra that really matter —and not waste valuable resources acquiring and evaluating those that don't.

Learn More
Applied-Biosystems-4800-Maldi-TOF-MS-System-10114
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21357

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21357
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3F *NEW* Atomic Absorption Spectrophotometer

Persee A3F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21355

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3F-*NEW*-Atomic-Absorption-Spectrophotometer-21355
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3G *NEW* Atomic Absorption Spectrophotometer

Persee A3G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21356

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3G-*NEW*-Atomic-Absorption-Spectrophotometer-21356
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21354

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21354
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21352

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21353

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990G-*NEW*-Atomic-Absorption-Spectrophotometer-21353
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping