We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Oven Sample Processor: 76-90 of 366

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
BMT Venticell 55 Comfort *NEW* Mechanical Forced Air Oven

BMT Venticell 55 Comfort *NEW* Mechanical Forced Air Oven

Cambridge ID #: 16562

An accurate and quick laboratory oven with a 55-liter chamber volume. Comfort model with a Fuzzy-Logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display.

Specifications:

  • Interior of stainless steel material: volume (55 l), depth (390 mm), width (400 mm), height (350 mm)
  • External dimensions: depth (640 mm), diameter of the air branch outer/inner (52/49 mm), width (620 mm), height (680 (N) mm)
  • Weight: 66 kg (gross)
  • Heat emission at 250 °C: 590 W
  • Air exchange speed at 250 °C: 45 cca/hour
  • Working Temperature (from 10 °C ambient temp): 250 / 300 °C
Learn More
BMT-Venticell-55-Comfort-*NEW*-Mechanical-Forced-Air-Oven-16562
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Venticell 55 ECO  *NEW* Mechanical Forced Air Oven

BMT Venticell 55 ECO *NEW* Mechanical Forced Air Oven

Cambridge ID #: 17724

Features:

The Venticell line is built with a patented system of forced air circulation which ensures a homogeneous profile for all heating and drying processes. Ideal for materials with high humidity.

 

Specifications:

 

  • Dimensions: 640 mm x diameter of the air branch outer/inner 52/49mm x 620 mm
  • Tray storage area: 380 x 335 mm
  • Racks: 4 max
  • Maximum weight per tray: 20 kg
  • Maximum weight inside the oven: 50 kg
  • Working temperature (beginning of the regulation): from 10 °C above ambient temp. to 250 °C
  • Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door, > 50 °C: time variation cca (±) 0,3 °C, space deviation (±) % cca (±)% of the reached temperature 1 %
  • Time required to reach 250 °C with closed air flap and voltage 230 V: 49 min
  • Heat emission at 250 °C: 590 W
  • Air exchange speed at 150 °C: 45 cca/hour
  • Electricity - mains 50/60 Hz: max. power input 1,3 kW
  • Nominal voltage: 230 V
  • Current: 5,6 A
  • Chamber volume: 55-liter
  • Working temperature: from +10°C over ambient temperature up to 250/300 °C
  • Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories
  • High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening
  • Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes
  • Standard model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Venticell-55-ECO--*NEW*-Mechanical-Forced-Air-Oven-17724
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Venticell 707 *NEW* Mechanical Forced Air Oven

BMT Venticell 707 *NEW* Mechanical Forced Air Oven

Cambridge ID #: 16567

An accurate and quick laboratory oven with a 707-liter chamber volume. Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories. Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes.

Specifications:

  • Interior of stainless steel material: volume (707 l), depth (540 mm), width (940 mm), height (1410 mm)
  • Weight: 240 kg (gross)
  • Heat emission at 250 °C: 2550 W
  • Air exchange speed at 250 °C: 12 cca/hour
  • Working Temperature (from 10 °C ambient temp): 250 / 300 °C
Learn More
BMT-Venticell-707-*NEW*-Mechanical-Forced-Air-Oven-16567
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Venticell 707 ECO  *NEW* Mechanical Forced Air Oven

BMT Venticell 707 ECO *NEW* Mechanical Forced Air Oven

Cambridge ID #: 17728

Features:

The Venticell line is built with a patented system of forced air circulation which ensures a homogeneous profile for all heating and drying processes. Ideal for materials with high humidity.

 

Specifications:

  • Dimensions: 790 mm x diameter of the air branch outer/inner 52/49mm x 1160 mm
  • Tray storage area: 920 x 485 mm
  • Racks: 19 max
  • Maximum weight per tray: 50 kg
  • Maximum weight inside the oven: 130 kg
  • Working temperature (beginning of the regulation): from 10 °C above ambient temp. to 250 °C
  • Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door, > 50 °C: time variation cca (±) 0,4 °C, space deviation (±) % cca (±)% of the reached temperature 2,5 %
  • Time required to reach 250 °C with closed air flap and voltage 230 V: 64 min
  • Heat emission at 250 °C: 2550 W
  • Air exchange speed at 150 °C: 12 cca/hour
  • Electricity - mains 50/60 Hz: max. power input 4,9 kW
  • Nominal voltage: 400/3N V
  • Current: 7,8 A
  • Chamber volume: 707-liter
  • Working temperature: from +10°C over ambient temperature up to 250/300 °C
  • Patented system of forced air flow in the chamber ensures a homogenous temperature profile for all processes of drying, heating and sterilizing materials in laboratories
  • High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening
  • Greater speed and accuracy of all tempering procedures ensures cost-saving operation; suitable especially for materials of high humidity, for demanding and accurate tests and processes
  • Standard model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Venticell-707-ECO--*NEW*-Mechanical-Forced-Air-Oven-17728
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  FC5816 *NEW* Benchtop Centrifuge

Ohaus FC5816 *NEW* Benchtop Centrifuge

Cambridge ID #: 20272

Features:

Frontier 5000 Multi Pro Centrifuges are designed for universal use in research, industrial & clinical laboratories, and can be combined with our rotors & accessories for customized use in specific applications. Available in 5 models with capacities from low microliter to 6x250 ml, and featuring high-speed performance at maximum volume, automatic rotor identification and safety features - these multi-purpose centrifuges are a must for any lab.

Applications

Centrifugal Separation, General Sample Preparation, Cell Pelleting, Protein Separation, Nucleic Acid Separation, Cell Concentrating, Chemical Separation, Diagnostics, Environmental Sample Preparation, Blood Sample Processing

Display

Backlit Liquid Crystal Display (LCD)

Operation

Designed to be used with a variety of rotors and accessories

Communication

N/A

Construction

Corrosion-resistant stainless steel chamber with Polycarbonate/ABS plastic lid

Design Features

Ten acceleration & deceleration rates, selection of running time from 10s to 99h 59min or continuous, quick spin, CFC-free refrigeration system, sample temp. indication (refrigerated models), lid-locking system, over-speed protection, dual imbalance sensing

 

Specifications:

 

 

  • Speed Range:200 rpm – 15,000 rpm
  • Maximum Relative Centrifuge Force (x g):21,379 g
  • Maximum Capacity (Rotor):6x250 ml
  • Acceleration Gear:10
  • Deceleration Gear:10
  • Dimensions (HxLxW):13.94 in x 21.18 in x 17.56 in (354 mm x 538 mm x 446 mm)
  • Display: LCD with backlight
  • Net Weight:115 lb (52 kg)
  • Noise Level:≤61±2 dB(A)
  • Power Consumption: 520 W
  • Rotor Recognition Method: Auto
  • Running Time: Quickspin;  10 sec to 99 h 59 min 59 sec;  Continous
  • Safety Certification: CE;  FCC
  • Working Environment:36°F – 95°F, 80%RH, non-condensing (2°C – 35°C, 80%RH, non-condensing)

 

 

Learn More
Ohaus-FC5816-*NEW*-Benchtop-Centrifuge-20272
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1312A HPLC Binary Pump

Agilent 1100 Series - G1312A HPLC Binary Pump

Cambridge Scientific ID #'s: 19857, 15626, 7526, 17475, 13985, 16317, 15936, 16119, 12811, 19156, 16034, 8571, 9300, 13406, 12452

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1312A-HPLC-Binary-Pump-19857
By clicking below we can further assist you with your inquiry. Inquire 15 In Stock Worldwide Shipping
Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cambridge ID #: 11053

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge Scientific ID #'s: 9625, 9227, 7876, 16066, 16118

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-9625
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16189, 16031, 17335, 16030, 15999

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-16189
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 17699, 17974, 16338, 17972

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - G1376A HPLC Capillary Pump

Agilent 1100 Series - G1376A HPLC Capillary Pump

Cambridge Scientific ID #'s: 9564, 15081, 17698

Specifications:

  • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
  • Settable column flow Range:
    • – 20 µl/min
    • – 100 µl/min (with the extended flow range kit)
    • – 2.5 µl/min (with the electronic flow control bypassed)
  • Recommended column flow range:
    • – 20 µl/min
    • 10 – 100 µl/min (with extended flow range kit)
    • – 2.5 ml/min (with the electronic flow sensor bypassed)
  • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
  • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
  • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
  • Delay volume:
    • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
    • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
    • for flow rates up to 100 µl/min and electronic flow control active:
    • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
    • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
  • Pressure range: 20 to 400 bar (5880psi) system pressure
  • Compressibility Compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog output For pressure monitoring, 2 mV/bar, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
  • Housing: All materials recyclable
Learn More
Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 17697, 15934, 16078, 18444, 16060, 16141, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-17697
By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Agilent 1100 Series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 18545

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1100-Series---G2260A-HPLC-Preparative-Autosampler-18545
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1312B HPLC Column Compartment

Agilent 1200 Series - G1312B HPLC Column Compartment

Cambridge ID #: 20123

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1312B-HPLC-Column-Compartment-20123
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16330, 16315

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-16330
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping