We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Oven Sample Processor: 91-105 of 374

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G1312B HPLC Column Compartment

Agilent 1200 Series - G1312B HPLC Column Compartment

Cambridge ID #: 20123

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1312B-HPLC-Column-Compartment-20123
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 21014, 21817, 21818

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-21014
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Cambridge Scientific ID #'s: 20340, 16349

Features:

  • Advanced temperature controlled detector optics ready to use within two hours of installation
  • Automatic zero and automatic purge combined with a recycle valve for automatic solvent recycling allow uninterrupted operation
  • Automatic light intensity control circuit to ensure the optimum performance of the optics
  • Integrated diagnostics for efficient troubleshooting
  • Built-in refractive index calibration
  • Front access to valves and capillaries for easy maintenance
  •  

Specifications:

  • Detection type: Refractive Index
  • Refractive index range: 1.00 – 1.75 RIU, calibrated
  • Measurement range: +/- 600 x 10-6 RIU
  • Optics temperature control: 5 ° C above ambient to 55 ° C
  • Sample cell volume: 8uL
  • Maximum pressure: 5 bar (0.5Mpa)
  • Maximum flow rate: 5mL/minute
  • Valves: Automatic purge and automatic solvent recycle
  • Volumes: Inlet port to sample cell 62uL, inlet port to outlet port 590uL
Learn More
Agilent-1200-Series---G1362A-HPLC-Refractive-Index-Detector-20340
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge ID #: 21013

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-21013
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1376A HPLC Capillary Pump

Agilent 1200 Series - G1376A HPLC Capillary Pump

Cambridge ID #: 20388

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1376A-HPLC-Capillary-Pump-20388
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative AutosamplerImage Coming Soon

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G4208A HPLC Communication Module

Agilent 1200 Series - G4208A HPLC Communication Module

Cambridge ID #: 19260

Agilent 1200 Series - G4208A

 

The Instant Pilot provides complete local control and monitoring of a single module or an entire Agilent 1100/1200/1260 and 1290 Series HPLC system. There is no data evaluation in the Instant Pilot. The Instant Pilot allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses and basic diagnostics and maintenance.

 

Specifications:

 

  • Dimensions (W x D x H): 130 × 225 × 35 mm (5.1 × 8.9 × 1.4 inches)
  • Weight: 0.8 kg (1.76 lbs)
  • Line Voltage: 22 VDC, ± 10 %
  • Power Consumption: 7 W
  • Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95%, at 25 – 40 °C (77 – 104 °F)
  • Operating Altitude: Up to 3000 m (9842 ft)
  • Non-Operating Altitude: Up to 4600 m (15092 ft)
Learn More
Agilent-1200-Series---G4208A-HPLC-Communication-Module-19260
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G1329B HPLC Autosampler

Agilent 1260 Infinity Series- G1329B HPLC Autosampler

Cambridge ID #: 19979

Features:

The Agilent 1260 Infinity II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses. It can house optionally the integrated column compartment for two LC columns with temperature control up to 80 °C, as well as a sample thermostat for stable temperature control from 4 °C - 40 °C, all within one module.

 

Specifications:

  • High capacity - up to 132 vials (2 mL) or up to 36 vials (6 mL).
  • Reliable injections -  0.1 to 100 µL injections for up to 600 bar (G7129A) and up to 800 bar (G7129C).
  • Easy volume extensions- for injection volumes up to 1,500 µL (G7129A), or up to 1,800 µL (G7129C) for applications ranging from microbore to semi-preparative chromatography.
  • Lowest carryover - with an in needle flush port included, for rinsing the outside of the needle.
  • Efficient temperature control - with an integrated column compartment as an option or upgrade available. Which holds two columns up to 30 cm length, and provides heating capacity from 5 degrees above ambient up to 80 °C for reproducible chromatography data at optimized resolution.
  • Integrated sample thermostat- available as an option or upgrade, providing cooling and heating (with thermostat) in the range from  4 °C - 40 °C.
  • Low internal volume - for minimum contribution to a system's total internal volume, which can be even further reduced using bypass mode.
  • Increased productivity - with overlapped injections.
  • Customizable injection program - available for customizing advanced injections as well as for sample preparation steps upfront injection.
Learn More
Agilent-1260-Infinity-Series--G1329B-HPLC-Autosampler-19979
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 20569, 20795

Features:

The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials

Specifications:

  • Temperature Range: Settable from 4 °C to 40 °C in 1 ° increments
  • Temperature Accuracy at Ambient
    • Temperatures < 25 °C and humidity < 50 %: 3 °C to 8 °C at a setpoint of 4 °C*
  • Temperature Accuracy at Ambient Temperatures
    • temperatures  < 30 °C and humidity < 60 %: 3 °C to 9 °C at a setpoint of 4 °C*
Learn More
Agilent-1290-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-20569
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1290 Series - G4226A HPLC Autosampler

Agilent 1290 Series - G4226A HPLC Autosampler

Cambridge ID #: 20794

Features:

The 1290 Infinity Autosampler features an increased pressure range enabling the use of today’s column technology (sub- two- micron narrow bore columns) with the Agilent 1290 Infinity LC System. Increased robustness is achieved by optimized new parts, high speed with lowest carry- over by flow through design, increased sample injection speed for high sample throughput, increased productivity by using overlapped injection mode and flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384- well plates allows you to process up to 768 samples unattended.

Specifications:

 

  • Injection range: 0.1 – 20 µL in 0.1 µL increments 0.1 – 40 µL in 0.1 µL increments if 40 µL loop is installed 0.1 – 120 µL in 0.1 µL increments with 1290 Infinity large volume injection kit (hardware modification required) pressure range up to 1200 bar 0.1 – 100 µL in 0.1 µL increments with 100 µL upgrade kit (G4214A) (hardware modification required) up to 600 bar
  • Precision: Typically <0.25 % RSD from 5 – 20 µL, Typically <0.5 % RSD from 2 – 5 µL volume, Typically <0.7 % RSD from 1 – 2 µL volume.
  • Pressure range:  Up to 1200 bar, Up to 600 bar 
  • Sample viscosity range: 0.2 – 5 cp
  • Sample capacity: Capacity 2 x well plates (MTP) + 10 x 2 mL vials, 108 x 2 mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials, 30 x 6 mL vials in 2 x 15 vial plate, 100 Micro vial tray, plus 10 additional 2 mL vials, 54 Eppendorf tubes (0.5/1.5/2 mL) in 2 x 27 Eppendorf tube plate.
Learn More
Agilent-1290-Series---G4226A-HPLC-Autosampler-20794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G4227A HPLC Flex Cube

Agilent 1290 Series - G4227A HPLC Flex Cube

Cambridge ID #: 14803

The Agilent 1290 Infinity Flexible Cube is an auxiliary module for the 1290 Infinity Autosampler with a built-in pump to facilitate enhanced flushing capabilities and to reduce carry-over. With access to three solvents, critical sections of flow path can be flushed at high flow rates. Automated back-flushing of the injection needle-seat achieves the absolute lowest sample carryover for LC and LC/MS applications. In addition, the Flexible Cube hosts up to two Agilent Quick-Change valves. For utmost flexibility, choose among Agilent’s broad portfolio of available valve heads suitable up to 1200 bar. The valves can be controlled independently for any demanding valve-switching application.

 

Specifications

  • Injection range                          
    • 1 - 20 μL
    • .1 - 40 μL
    • .1 - 100 μL
    • in 0.1 μL increments
  • Precision: Precision of G4226A sampler will not be influenced
  • Accuracy: Accuracy of G4226A sampler will not be influenced
  • Sampler pressure range: Up to 1200 bar
  • Pressure range of flush pump: Up to 50 bar
  • Flow rate of flush pump: Up to 4 mL/min
  • Number of solvents: Up to 3 solvents
  • Sample viscosity range: 0.2 – 5 cp
  • Carry over:  Typically <0.001% (10 ppm)
Learn More
Agilent-1290-Series---G4227A-HPLC-Flex-Cube-14803
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Series - G7167B HPLC Multisampler

Agilent 1290 Series - G7167B HPLC Multisampler

Cambridge Scientific ID #'s: 20044, 20043, 20041

The Agilent 1290 Infinity Multisampler sets a new benchmark in flexibility. This autosampler can handle both vials and microtiter plates (whether shallow or deep) with ease and efficiency. This compact module has the capacity to house up to 6,144 samples plus the robotics to smoothly inject each into the chromatograph in turn. With Agilent’s unique dual- needle design, cycle time can be as low as just 5 seconds. With the multi- wash capability, you can reduce carryover to less than 10 parts per million. This innovative Multisampler is designed to provide maximum flexibility and scalability.

Specifications:

  • Injection range:1- 20 µL in 0.1 µL increments
  • Precision: Typically (0.15% RSD or SD<10 nL
  • Pressure range: Up to 1200 bar
  • Sample viscosity range:2 – 5 cp
  • Sample capacity:
    • 1H Drawer: Up to 8 drawers and 16 positions Shallow well plates (MTP)
    • 2H Drawer: Up to 4 drawers and 8 positions MTP, deep well plates, vials, Eppendorf
    • 3H Drawer: Up to 2 drawers and 4 positions MTP, deep well plates, vials up to 6 mL, Eppendorf
  • Injection cycle time: <10 s using following standard conditions
    • Default draw speed: 100 µL/min
    • Default eject speed: 400 µL/min
    • Injection Volume: 1 µL
Learn More
Agilent-1290-Series---G7167B-HPLC-Multisampler-20044
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Fisher Scientific 13-988-326F-2 -20 FreezerImage Coming Soon

Fisher Scientific 13-988-326F-2 -20 Freezer

Cambridge ID #: 15985

Features:

Programmable microprocessor control provides reliable sample protection, superior performance, excellent energy efficiency, and low noise levels.

 

Learn More
Fisher-Scientific-13-988-326F-2--20-Freezer-15985
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Boekel 145702 Water Bath

Boekel 145702 Water Bath

Cambridge ID #: 20801

Features:

  • Digital Microprocessor Control with advanced safety over temperature protection
  • L.E.D. illuminated black background with transparent PYREX dish; allows specimen to be easily seen
  • A nonvolatile memory retains the last temperature set point after power off/on
  • Supplied with a removable PYREX dish
  • Units are certified to UL61010-1, CSA C22.2 and CE approved

 

Specifications:

 

  • Injection range: 0.1 – 20 µL in 0.1 µL increments 0.1 – 40 µL in 0.1 µL increments if 40 µL loop is installed 0.1 – 120 µL in 0.1 µL increments with 1290 Infinity large volume injection kit (hardware modification required) pressure range up to 1200 bar 0.1 – 100 µL in 0.1 µL increments with 100 µL upgrade kit (G4214A) (hardware modification required) up to 600 bar
  • Precision: Typically <0.25 % RSD from 5 – 20 µL, Typically <0.5 % RSD from 2 – 5 µL volume, Typically <0.7 % RSD from 1 – 2 µL volume.
  • Pressure range:  Up to 1200 bar, Up to 600 bar 
  • Sample viscosity range: 0.2 – 5 cp
  • Sample capacity: Capacity 2 x well plates (MTP) + 10 x 2 mL vials, 108 x 2 mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials, 30 x 6 mL vials in 2 x 15 vial plate, 100 Micro vial tray, plus 10 additional 2 mL vials, 54 Eppendorf tubes (0.5/1.5/2 mL) in 2 x 27 Eppendorf tube plate.
Learn More
Boekel-145702-Water-Bath-20801
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Biotage 150 Flash Flash Chromatography System

Biotage 150 Flash Flash Chromatography System

Cambridge ID #: 21517
  • Specifications:

    • Column size: 150 x 300mm
    • Sample load mass: 180g
    • Flow rate: 500mL/min
    • Purification time: 90min
    • Pure compound per run: 70.5g
    • Recovery ratio: 87%