Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Ovens and Furnaces ranging from General Purpose Ovens, Mechanical Ovens and Gravity Convection Ovens, Forced Air Ovens, Vacuum Ovens to Hybridization Ovens. Some of our popular manufacturers include Fisher, VWR, Lindburgh, Blue M, Precision, Thermolyne and Napco.

Printer: 1-15 of 138

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Mitsubishi P93 Printer

Mitsubishi P93 Printer

Cambridge ID #: 19664

Features

  • User-friendly settings with control switches and an LED indicator
  • High-resolution thermal head with 325 dpi
  • Extremely compact dimensions and lightweight design
  • Fast print speed
  • 7 different picture formats
  • Picture memory for 10 individually selectable frames\

 

Specifications:

  • Print Method: Thermal-sensitive
  • Resolution: Printhead 325 dpi (12.8 dots/mm), max. resolution:1280x600 dots (panorama)
  • Greyscale: 256 greyscales
  • Print Speed: Standard 3.9 seconds
  • Paper Size: 100 x 110 mm
  • Interface: NTSC, PAL, Composite Video
  • Power Consumption: AC 100 - 240V,  50 / 60 Hz
  • Dimensions: 154 x 920 x 256 mm
Learn More
Mitsubishi-P93-Printer-19664
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Advanced Instruments 3D3 Osmometer

Advanced Instruments 3D3 Osmometer

Cambridge Scientific ID #'s: 21499, 8522

Specifications:

  • Electrical
    • Power Requirement: 100 to 130 VAC (60 Hz) or 200 to 250 VAC (50 Hz)
    • Fuses (2): 250V time delay (Type T): 2-Amp (100-130 VAC), 1-Amp (200-250 VAC)
    • Power Consumption: 150 watts
    • Memory Backup: Integral lithium cell; 10 years typical
  • Sample Volume: 0.20 to 0.25 mL
  • Sample Capacity: Single sample
  • Readout: 20-character digital display
  • Units: mOsm/kg H2O
  • Ranges:
    • Low: 0 to 2000 mOsm/kg H2O
    • High: 1400 to 4000 mOsm/kg H2O
  • Resolution: 1 mOsm/kg H2O
  • Communications: DTE RS-232C, parallel printer, barcode
  • Performance at Reference Conditions
    • Linearity: Less than ±0.5% from straight line
    • Repeatability: 0 to 400 mOsm ±2 mOsm/kg (1 S.D.)  400 to 4000 mOsm ±0.5% (1 S.D.)
    • Drift: Less than 1 digit per month
  • Performance Over Reference Conditions
    • Temperature Effect: 1 digit for every 5°C (9°F) ambient temperature change
    • Operating Conditions Temperature:
      • 18°C to 35°C (64°F to 95°F)
      • Humidity: 5 to 80% R.H. (non-condensing)
        • Storage Temperature: - 40°C to +45°C (-40°F to +113°F)
      • Start-up Time: From Stand-By: immediately
      • From Power On: under 5 minutes
      • Test Time: Approximately 2 minutes per sample in 0 to 2000 mOsm range; moderately longer in high range.
      • Dimensions
        • 0 cm x 32.0 cm x 42 cm
        • (11.5" H x 12.5" W x 16.5" D)
        • Height With Head Up: 41 cm (16" H)
      • Weight
        • Net: 12 kg (27 lbs.)
        • Shipping: 18 kg (38 lbs.)
Learn More
Advanced-Instruments-3D3-Osmometer-21499
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Advanced Instruments A2O Osmometer

Advanced Instruments A2O Osmometer

Cambridge Scientific ID #'s: 22464, 22465

A fully automated, multi-sample osmometer that sets the new benchmark for analytical performance, ease of use, and true walkaway operation

Specifications:

  • Sample Test Volume: 100 µL
  • Aspirated Sample Volume: 150 µL
  • Sample Capacity: 20-sample carousel
  • Test Time: Less than 3 minutes
  • Sample Throughput: Can process 20 samples in less than 1 hour
  • Units: mOsm/kg H2O
  • Calibrated Range: Low: 0 to 2000 mOsm/kg H2O; Full: 0 to 4000 mOsm/kg H2O
  • Resolution: 1 mOsm/kg H2O
  • Calibration: 3-point calibration for low range, 4-point for full range
  • Communications: Onboard printer, 10/100Mbps Ethernet, 4 USB 1.0/1.1/2.0, integrated bar code scanner 
  • Accuracy*: 0 to 400 mOsm: mean value ≤2 mOsm/ kg H2O from nominal value 400 to 4000 mOsm: mean value ≤0.5% from nominal value
  • Precision*(within run): Standard deviation ±2 mOsm/kg H2O between 0 and 400 mOsm; standard deviation ± 0.5% of value between 400 and 4000 mOsm
  • Drift*: Less than 1 mOsm/kg H2O per month 
  • Temperature Effect**: Recalibration recommended for ambient temperature changes of 5°C (9°F) or greater
  • Storage Temperature: -40°C to +45°C (-40°F to +113°F)
  • Sample Viscosity: Up to 20 mPa•s (20 cP), higher viscosities may affect pipettor accuracy
  • Pipettor Accuracy: <1%
  • Electrical Voltage: 100-240 V AC (50-60 Hz)
  • Power Consumption: 375 W
  • Dimensions(D x W x H): 20.5” x 23.6” x 22.8” , (52 cm x 60 cm x 58 cm)
  • Net Weight: 68 lb (31 kg)

* Performance at Reference Conditions — 20°C to 25°C (68°F to 77°F); 40% to 60% relative humidity; tolerances of reference or calibration solutions excluded

** Operating Conditions — 18°C to 35°C (64°F to 95°F); 5% to 80% relative humidity (noncondensing)

Learn More
Advanced-Instruments-A2O-Osmometer-22464
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Absorbance Reader

Benchmark Scientific Accuris SmartReader 96 MR9600 *NEW* Microplate Absorbance Reader

Cambridge ID #: 18282

The SmartReader 96 comes complete with 4 popular filters: 405,450,492,630nm and twenty six additional filters are available separately to cover a full range from 340 to 750nm.  The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming. Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons.  Kinetic calculations can be performed by setting multiple readings. The SmartReader 96 is a convenient stand alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing.  A data port can be used for connecting a computer or basic printer.

 

Specification:

 

  • Control and Display: 7 inch touch screen (800 x 480 pixels)
  • Light Source: Quartz-halogen lamp 6V/10W
  • Wavelength Range: 340-750nm (405, 450, 492 and 630 nm filters included)
  • Half-Bandwidth of filter: 3~9nm
  • Readout Range: 0~4.000 Abs
  • Linearity (405nm): 0~2.000 Abs <+1% / 0~4.000 Abs <+2%
  • Precision: CV</= 0.2% (0-3) Abs ; CV</= 01.0% (3-4) Abs
  • Test Speed: <6 sec. for 96 well plate
  • Shaking: 3 modes - slow, medium, fast
  • User Interface: Integrated software and touch screen control
  • Storage: 200 programs; 100,000 test records
  • Ports: USB ports for PC, printer, mouse and flash drive
  • Dimensions: 295x440x225 mm (11.6 x 17 x 8.75 inches)
  • Weight: 10 kg
Learn More
Benchmark-Scientific-Accuris-SmartReader-96-MR9600-*NEW*-Microplate-Absorbance-Reader-18282
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 ACL TOP 500 CTS

ACL TOP 500 CTS

Cambridge ID #: 22616

Highly automated with a compact size and complete end-to-end automation, offers a broad menu for routine and specialty assays.

Specifications:

  • Test menu: Clotting, chromogenic and immunological assays
  • Continuous sample and reagent loading: YES
  • Continuous operation: YES
  • Sample and reagent transport system: Racks
  • Samples onboard: 80 (10/sample rack)
  • Closed-Tube Sampling: YES (cap-piercing)
  • Reagents onboard: 40 (refrigerated)
  • Reagents barcode reader: YES (integrated)
  • Barcoded reagents: YES (barcode includes lot, exp. date and vial size)
  • Cuvettes onboard: 800
  • Applications onboard: 500 (250 user-definable)
  • Tests/sample: 30
  • Throughput:
    • PT: up to 240 tests/hr (240 samples/hr)
    • APTT: up to 180 tests/hr (180 samples/hr)
    • PT/APTT: up to 180 tests/hr (90 samples/hr)
  • Sample predilution: YES
  • Calibration curve predilution: YES
  • Factor parallelism: YES
  • Rerun and reflex testing: YES (configurable)
  • Reaction-curves display: YES
  • Quality Control program: YES (with configurable multi-rules)
  • Results autovalidation: YES
  • Patient sample results database: 20,000 samples (configurable)
  • Security system: YES (configurable)
  • Events log system: YES
  • Bidirectional interface: YES
  • Host query function: YES
  • PC: External (dedicated)
  • Operating system: Windows XP
  • Monitor: 17-inch color LCD touchscreen (external)
  • Keyboard: YES (external)
  • Mouse: YES (external)
  • Printer: YES (external)
  • User interface: Windows XP-based
  • Unit dimensions (w x d x h): 110 x 82 x 73 cm (43 x 32 x 29 in)
  • Weight (analyzer): 147 kg (324 lbs)
Learn More
-ACL-TOP-500-CTS--22616
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Mettler Toledo AT261 Analytical Balance

Mettler Toledo AT261 Analytical Balance

Cambridge ID #: 22354

Features:

  • Standard asynchronous serial format
  • Baud rate and parity freely selectable
  • Bidirectional data transfer
  • Break recognition
  • Galvanic isolation
  • RS-232 and 20 mA current loop
  • Several handshake modes
  • 7-bit ASCII character set
  • Extensive command set – access to virtually all balance parameters
  • Easy connection to printers and computers

 

Specifications:

  • Readability: 0.01 mg - 0.1 mg
  • Weighing capacity: 62 g - 205 g
  • Taring range (by subtraction): 0…205 g
  • Reproducibility (s) 0...50 g: 0.015 mg
  • Reproducibility (s) 50...100 g: 0.02mg, 0.03 mg
  • Reproducibility (s) 100...200 g: 0.03mg, 0.05mg
  • Linearity: ± 0.03mg, ± 0.15mg
  • Linearity referred to 5 g: ± 0.02 mg
  • Stabilization time (typical) variable with vibration adapter: 8,12,18 s - 3,5,7 s
  • Built-in calibration weights: 2x100 g. Measured to ±0.1 mg (±0.01 mg AT20/21) at an air density of 1200 mg/l on virtual mass with density 8.0 g/cm3.
  • Calibration FACT: Fully automatic motorized self-calibration with two built-in weights (manual triggering also possible). Test possibility to check the calibration.
  • Calibration with external weight: 200 g
  • Display with METTLER Deltatrac: LCD (liquid crystal)
  • Display sequence: 0.2...0.4 s variable
  • Sensitivity drift (5...40°C): Maximum deviation with automatic self-calibration ±0.00015%, (with automatic self-calibration switched off) 1 ppm/°C.
  • Linearization: Automatic self-linearization of the weighing curve (simultaneously with motorized calibration FACT).
  • Data interface: CL and RS232C, bidirectional, built in as standard, all lines galvanically separated.
  • Glass draft shield: No hindering guideways; automatic motorized opening or at a keystroke. 
  • Inner draft shield AT: Standard
  • AC adapter (to national codes): Voltage 115 V or 230 V, admissible voltage fluctuations: +15...-20%. Frequency: 50...60 Hz; power consumption 15,5W max.
  • Admissible ambient conditions: Temperature: 5...40 °C; relative humidity: 25...85% (non-condensing). Height above sea level: -500...+6000 m.
  • Weighing pan feedthrough for below-the-balance weighing: 80x80 [mm]; stainless steel
  • Measures: Free height above weighing pan 239 mm, Balance housing 241x433x289 (WxLxH), AC adapter 115x140x53mm (WxLxH)
  • Weight: Balance 9.3 kg, AC adapter 1.2 kg
  • Vibration adapter (symbol [ ~ ]): 3 settings for matching to location: suppression of the effect of vibrations.
  • Weighing process adapt. (symbol [ ]): 4 settings for matching to weighing application: dispensing, universal setting, absolute weighing, special applications.
  • Stability detection (ASD): 8 settings with different tolerance thresholds (off, 1...7). 
  • Weight unit 1: Freely selectable in the configuration register: g, mg, oz, ozt, tl, GN, dwt, ct, C.M., mo.
  • Weight unit 2 (incl. applications): Freely selectable in the configuration register: g, mg, oz, ozt, tl, GN, dwt, ct, C.M., mo, PCS, Stk, %. The selected weight units 1 and 2 can be switched at a keystroke.
  • Applications: PCS, Stk. (piece counting, reference 10, 20, 50, 100) and % (percent weighing) are built-in applications.
Learn More
Mettler-Toledo-AT261-Analytical-Balance-22354
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Eppendorf Biophotometer Spectrophotometer Visible/Absorbance Reader

Eppendorf Biophotometer Spectrophotometer Visible/Absorbance Reader

Cambridge ID #: 22076

 

State-of-the-art technology with an easy-to-use format in a compact footprint: that is the Eppendorf BioPhotometer! It's large key pads, pre-programmed methods, and pre-set wavelengths and conversion factors greatly simplify the sample quantification. The large LCD screen displays the sample concentrations, absorption values, OD260/OD230 and OD260/OD230 and sample dilutions at a glance.

 

Features:

  • Compact design, easy to transport
  • Robust housing, splash- and water-resistant
  • High-value components guarantee high operating safety
  • Metal housing ensures high stability
  • Xenon flash lamp source with extremely long service life
  • Ready to measure immediately (no warmup time)
  • Self-explanatory, extremely simple operation
  • Measurement only takes approx 2 seconds
  • Programmed methods: ssDNA, dsDNA, RNA, Oligo, Protein, Lowry/Lowry micro, Bradford/Bradford micro, BCA/BCA micro, and OD 600
  • Optional background correction at 320 nm for UV methods
  • Automatic calculation of sample dilution
  • Simple conversion using the "Conversion" key
  • Up to 10 standards for colorimetric analyses
  • Storage of the last 100 results and all corresponding data
  • Storage of all calibrations
  • Sample data and calibration data can be called up after being stored

 

Specifications:

 

  • Optical system:  Absorption, single-beam photometer with reference beam
  • Light source: Xenon flash lamp
  • Light beam height: 8.5 mm
  • Spectral range:  220 to 750 nm
  • Wavelengths: Xe 230; 260; 280; 320; 562; 595 nm
  • Spectral range width: 5 nm: 230 to 320 nm; 7 nm: 562 to 595 nm
  • Photometric measuring range: 0,000 to 3,000 A
  • Photometric accuracy: ±1% at 1 A
  • Photometric precision: < 0.5% at 1 A
  • Method-dependent evaluation:    - Absorbance/concentration using factor
    • Concentration using calibration with 1 to 10 standards
    • One-point calibration (1 std) / linear regression (2 to 10 standards)
    • Non-linear regression (polynom, 3rd degree; 4 or 5 standards), 1x, 2x or 3x determination
    • Ratio 260/280, ratio 260/230, molar concentration, total yield
    • Warburg formula for protein direct A280
  • Calibration memory: For protein methods
  • Results memory: For 100 results with absorbance, ratio values, sample no., dilution, date and time
  • Printer interface: RS-232C, serial, for printer or PC with BioPhotometer software package
  • Power consumption: Approx. 20 W in operation; 10 W in standby mode
  • Cuvettes: UVette and common rectangular cuvettes of suitable glass or plastic materials
Learn More
Eppendorf-Biophotometer-Spectrophotometer-Visible-Absorbance-Reader-22076
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 111 ECO *NEW* Mechanical Forced Air Incubator

BMT Climacell 111 ECO *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 17755

Features:

The conditioned chambers of the CLIMACELL product line provide all conditions for exact and reproducible simulation of various climatic conditions, applicable e.g. in testing of stability components and food or chemicals packages, or in studies of germs, plant or tissue cultures, and insects. These devices offer an interesting alternative to expensive testing chambers and testing rooms. Microprocessor-controlled system of humidification and dehumidification with a powerful lighting system guarantees excellent homogenous parameters for testing and growth conditions.

Specifications:

 

  • Chamber volume: 111-liter
  • Volume of the steam space: 163 approx. L
  • Min. distance between trays: 70 mm
  • Storage area (w x d): 520 x 335 mm
  • Max. power: 1700 W
  • Protective system: IP 20
  • Mains: 50/60Hz 230 V
  • Cooling/down time from 22 °C to 10 °C: < 21 min
  • Heating/up time to 37 °C from the ambient temperature: 11 min
  • Working temperature from 0: 0 to 100 °C
  • Working temperature from: -20 to 100 °C
  • Temperature accuracy - in time 0: 2 ± °C
  • Temperature accuracy in time at 10 °C: < 0,5 ±°C
  • Temperature accuracy in time at 37 °C: < 0,5 ±°C
  • Recovery time after 30 sec. door open according DIN 12 880
    at 37 °C 4 min
    at 50 °C 5 min
  • Relative humidity range: 10–98 %
  • Heat emission at 37 °C: 70 W
  • Working temperature from: 0.0 °C up to 100°C (without humidity); from 10°C to 95°C (with humidity)
  • Patented cooling system (ecological cooling medium R134a) and air flow in the chamber ensure a quick and precise distribution of the preset temperature and humidity in the chamber, which allows an ideal process of samples heating and reduction of humidity condensation in the chamber
  • High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature and humidity recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed
  • Suitable for use in research of germs, plant or tissue cultures, insect, stability testing, etc.
  • Comfort model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Climacell-111-ECO-*NEW*-Mechanical-Forced-Air-Incubator-17755
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 1212 ECO *NEW* Mechanical Forced Air IncubatorImage Coming Soon

BMT Climacell 1212 ECO *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 17759

Features:

The conditioned chambers of the CLIMACELL product line provide all conditions for exact and reproducible simulation of various climatic conditions, applicable e.g. in testing of stability components and food or chemicals packages, or in studies of germs, plant or tissue cultures, and insects. These devices offer an interesting alternative to expensive testing chambers and testing rooms. Microprocessor-controlled system of humidification and dehumidification with a powerful lighting system guarantees excellent homogenous parameters for testing and growth conditions.

Specifications:

 

  • Chamber volume: 1212-liter
  • Working temperature from: 0.0 °C up to 100°C (without humidity); from 10°C to 70°C (with humidity)
  • Volume of the steam space: 1753 approx. L
  • Min. distance between trays: 70 mm
  • Storage area (w x d): 520 x 485 mm
  • Max. power: 3500 W
  • Protective system: IP 20
  • Mains: 50/60Hz 230 V
  • Cooling/down time from 22 °C to 10 °C: < 21 min
  • Heating/up time to 37 °C from the ambient temperature: 30 min
  • Working temperature from 0: 0 to 70 °C
  • Working temperature from: -20 to 70 °C
  • Temperature accuracy - in time:  2 ± °C
  • Temperature accuracy in time at 10 °C < 0: 9 ±°C
  • Temperature accuracy in time at 37 °C < 0: 5 ±°C
  • Recovery time after 30 sec. door open according DIN 12 880
    at 37 °C 10 min
    at 50 °C 10 min
  • Relative humidity range: 10–98 %
  • Heat emission at 37 °C: 200 W
  • Patented cooling system (ecological cooling medium R134a) and air flow in the chamber ensure a quick and precise distribution of the preset temperature and humidity in the chamber, which allows an ideal process of samples heating and reduction of humidity condensation in the chamber
  • High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature and humidity recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed
  • Suitable for use in research of germs, plant or tissue cultures, insect, stability testing, etc.
  • Comfort model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Climacell-1212-ECO-*NEW*-Mechanical-Forced-Air-Incubator-17759
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 222 ECO *NEW* Mechanical Forced Air Incubator

BMT Climacell 222 ECO *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 17756

Features:

The conditioned chambers of the CLIMACELL product line provide all conditions for exact and reproducible simulation of various climatic conditions, applicable e.g. in testing of stability components and food or chemicals packages, or in studies of germs, plant or tissue cultures, and insects. These devices offer an interesting alternative to expensive testing chambers and testing rooms. Microprocessor-controlled system of humidification and dehumidification with a powerful lighting system guarantees excellent homogenous parameters for testing and growth conditions.

Specifications:

 

  • Volume of the steam space: 299 approx. L
  • Min. distance between trays: 70 mm
  • Storage area (w x d): 520 x 485 mm
  • Max. power: 1850 W
  • Protective system: IP 20
  • Mains: 50/60Hz 230 V
  • Cooling/down time from 22 °C to 10 °C: < 21 min
  • Heating/up time to 37 °C from the ambient temperature: 11 min
  • Working temperature from 0: 0 to 100 °C
  • Working temperature from: -20 to 100 °C
  • Temperature accuracy - in time 0: 2 ± °C
  • Temperature accuracy in time at 10 °C: < 0: 5 ±°C
  • Temperature accuracy in time at 37 °C < 0: 5 ±°C
  • Recovery time after 30 sec. door open according DIN 12 880
    at 37 °C 3 min
    at 50 °C 6 min
  • Relative humidity range: 10–98 %
  • Heat emission at 37 °C: 63 W
  • Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit
  • High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed
  • Suitable for demanding and accurate tests and samples cultivation
  • Comfort model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Climacell-222-ECO-*NEW*-Mechanical-Forced-Air-Incubator-17756
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 404 *NEW* Mechanical Forced Air Incubator

BMT Climacell 404 *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 16615

Laboratory incubator with a 404-liter chamber volume. Patented cooling system (ecological cooling medium R134a) and air flow in the chamber ensure a quick and precise distribution of the preset temperature and humidity in the chamber, which allows an ideal process of samples heating and reduction of humidity condensation in the chamber. Comfort model with a Fuzzy-Logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display. Wide range of optional equipment and accessories and output option for a printer or PC connection.

Specifications:

  • Interior of stainless steel material: volume (404 l), depth (520 mm), width (540 mm), height (1410 mm)
  • Volume of the steam space: 524 l
  • Working temperature (from 0.0 to): 99.9 °C
  • Heat emission at 37 °C: 123 W
  • Outer dimensions: depth (790 mm), width (1010 mm), height (1920 mm)
  • Weight: 391 kg (brutt cca)
Learn More
BMT-Climacell-404-*NEW*-Mechanical-Forced-Air-Incubator-16615
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 404 ECO *NEW* Mechanical Forced Air Incubator

BMT Climacell 404 ECO *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 17757

Features:

The conditioned chambers of the CLIMACELL product line provide all conditions for exact and reproducible simulation of various climatic conditions, applicable e.g. in testing of stability components and food or chemicals packages, or in studies of germs, plant or tissue cultures, and insects. These devices offer an interesting alternative to expensive testing chambers and testing rooms. Microprocessor-controlled system of humidification and dehumidification with a powerful lighting system guarantees excellent homogenous parameters for testing and growth conditions.

 

Specifications:

 

  • Volume of the steam space: 524 approx. L
  • Min. distance between trays: 70 mm
  • Storage area (w x d): 520 x 485 mm
  • Max. power: 2700 W
  • Protective system: IP 20
  • Mains: 50/60Hz 230 V
  • Cooling/down time from 22 °C to 10 °C: < 21 min
  • Heating/up time to 37 °C from the ambient temperature: 22 min
  • Working temperature from 0: 0 to 100 °C
  • Working temperature from: -20 to 100 °C
  • Temperature accuracy - in time: 0,3 ± °C
  • Temperature accuracy in time at 10 °C: < 1 ±°C
  • Temperature accuracy in time at 37 °C: < 1 ±°C
  • Recovery time after 30 sec. door open according DIN 12 880
    at 37 °C 3 min
    at 50 °C 7 min
  • Relative humidity range: 10–98 %
  • Heat emission at 37 °C: 123 W
  • Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit
  • High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed
  • Suitable for demanding and accurate tests and samples cultivation
  • Comfort model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Climacell-404-ECO-*NEW*-Mechanical-Forced-Air-Incubator-17757
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Climacell 707 ECO *NEW* Mechanical Forced Air Incubator

BMT Climacell 707 ECO *NEW* Mechanical Forced Air Incubator

Cambridge ID #: 17758

Features:

The conditioned chambers of the CLIMACELL product line provide all conditions for exact and reproducible simulation of various climatic conditions, applicable e.g. in testing of stability components and food or chemicals packages, or in studies of germs, plant or tissue cultures, and insects. These devices offer an interesting alternative to expensive testing chambers and testing rooms. Microprocessor-controlled system of humidification and dehumidification with a powerful lighting system guarantees excellent homogenous parameters for testing and growth conditions.

Specifications:

 

  • Volume of the steam space: 876 approx. L
  • Min. distance between trays: 70 mm
  • Storage area (w x d): 920 x 485 mm
  • Max. power: 3000 W
  • Protective system: IP 20
  • Mains: 50/60Hz 230 V
  • Cooling/down time from 22 °C to 10 °C: < 21 min
  • Heating/up time to 37 °C from the ambient temperature: 13 min
  • Working temperature from 0: 0 to 100 °C
  • Working temperature from: -20 to 100 °C
  • Temperature accuracy - in time: 0: 4 ± °C
  • Temperature accuracy in time at 10 °C: < 1 ±°C
  • Temperature accuracy in time at 37 °C: < 1 ±°C
  • Recovery time after 30 sec. door open according DIN 12 880
    at 37 °C 6 min
    at 50 °C 6 min
  • Relative humidity range: 10–98 %
  • Heat emission at 37 °C: 148 W
  • Patented cooling system (ecological cooling medium R134a) offers a precise and quick simulation of natural processes and reduces the risk of samples evaporation; various types of the inner chamber lighting can be added to the unit
  • High operation comfort; precise temperature regulation; possibility to reach even extremely short times of temperature changes and short times of temperature recovery in the chamber after the door opening; the standard equipment includes inner glass door and possibility to regulate the fan speed
  • Suitable for demanding and accurate tests and samples cultivation
  • Comfort model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LCD display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
BMT-Climacell-707-ECO-*NEW*-Mechanical-Forced-Air-Incubator-17758
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MJ Research Dual 30 Well Alpha BlocksImage Coming Soon

MJ Research Dual 30 Well Alpha Blocks

Cambridge ID #: 13437

Description:

The MJ Research PTC-200 Gradient Thermal Cycler is a reliable peltier thermocycler with swappable alpha blocks. This gradient cycler is equipped with interchangeable sample blocks and heat pump assemblies, which allow users to easily change formats in between runs while maintaining NIST-traceable accuracy. This PTC-200 comes with a Dual 30 well block. The Hot Bonnet heated lid fitted onto the PTC-200 thermal cycler controls pressure and height, enabling oil-free cycling. The MJ Research PTC-200 also has a large built-in memory and software that allows control over virtually every thermal parameter. Intuitive software and easy-to-read interface enables quick and painless programming, editing, file management, password protection, and more.The PTC-200 also features Instant Incubate for continuous temperature incubations.

Specifications:

  • Thermal Range: 5° to 105°C, but no more than 30°C below ambient temperature (4° to 100°C for the slide Chambers Alpha Unit)
  • Thermal Accuracy: ±0.3°C of programmed target at 90°C- NIST-traceable
  • Thermal Homogeneity: ±0.4°C well-to-well within 30 seconds of arrival at 90°C (for most Alpha units; see specifications for individual Alpha Units)
  • Parallel: 1x 25-pin 8-bit parallel interface printer port
  • Serial: 1x 9-pin RS-232 serial port for printer or remote use
  • IEEE: 1x IEEE-488 bidirectional general purpose interface bus
  • Display: 1x 20 x 4 LCD alphanumeric display
  • Dimensions (W x L x H): 12 x 12 x 12 in
  • Weight: 25 lbs.
Learn More
MJ-Research-Dual-30-Well-Alpha-Blocks-13437
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BMT Durocell 111 *NEW* Gravity Oven

BMT Durocell 111 *NEW* Gravity Oven

Cambridge ID #: 16600

Highly durable laboratory oven with a 111-liter chamber volume. High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc. Standard model with a Fuzzy-Logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display. Wide range of optional equipment and accessories and output option for a printer or PC connection.

Specifications:

  • Interior of stainless steel material: volume (111 l), depth (390 mm), width (540 mm), height (530 mm)
  • External dimensions: depth (640 mm), diameter of the air branch outer/inner (52/49 mm), width (760 mm), height (860 (N) mm)
  • Weight: 87 kg (gross)
  • Heat emission at 100 °C: 490 W
  • Air exchange speed at 100 °C: 12 per hour
  • Working Temperature (from 5 °C above ambient temp): 125 °C
Learn More
BMT-Durocell-111-*NEW*-Gravity-Oven-16600
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping