We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Recirculating Chiller: 1-15 of 28

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Thermo Forma C35P Recirculating Chiller

Thermo Forma C35P Recirculating Chiller

Cambridge ID #: 13346

Specifications:

  • Temperature: 30° to 200°C
  • Temperature Accuracy: 0.01 +/-K
  • Capacity: 8L
Learn More
Thermo-Forma-C35P-Recirculating-Chiller-13346
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Neslab HX-150 Recirculating Chiller

Neslab HX-150 Recirculating Chiller

Cambridge ID #: 18447

Specification

 

  • Refrigerant: R22
  • Amount: 28 oz (794 g)
  • Hot gas settings: 25 PSIG (172 kPa)

 

  • Suction pressure at 25°C

 

    • Suction PSIG: 76 - 89
    • Discharge PSIG: 255 - 285
    • Speed check: 1.9 - 2.4
  • Temperature range: 5°C to 35°C
  • Cooling capacity at 20°C: 4500 Watts
  • Available voltage: 200 - 230V 1 Ph
  • Cooling options: Air / Water
Learn More
Neslab-HX-150-Recirculating-Chiller-18447
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Neslab Merlin M33 Recirculating Chiller

Thermo Neslab Merlin M33 Recirculating Chiller

Cambridge ID #: 19906

 

Specifications:

  • Capacity: 1.9L
  • Temperature Range: +5°C to +35°C
  • Temperature Stability:  ±0.1°C
  • Cooling Capacity at 20°C: 1250W
  • Cooling Capacity at 5°C: 490 W
  • Maximum Flow Rate (L/min): 6.75
  • Power Requirements: 115V, 60hz, 13A
Learn More
Thermo-Neslab-Merlin-M33-Recirculating-Chiller-19906
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
 RC006G03CB1C005 Recirculating Chiller

RC006G03CB1C005 Recirculating Chiller

Cambridge ID #: 22233
  • Recirculating Chillers with Cooling Capacities cools the synrad laser Specifications:- BTU/Hour: 11800; Amperage At 208/230 Volts AC: 16.0; Pump Type: Positive Displacement Pump"“Brass 4.3 gpm; Reservoir Capacity: 6; Recommended Cooling Fluids: Water or Ethlyene Glycol/Water Mixture; Phase: 1; Frequency Hz: 60Hz; Compressor Capacity Horse Power: 1.000; Dimensions (H x W x D): 31.9 x 21.4 x 27.8 in; Inlet Size: 1/2 FNPT; Outlet Size: 1/2 FNPT; Temperature Range 40 "“ 95; Tank Material: Polyethylene
  • Learn More
    -RC006G03CB1C005-Recirculating-Chiller-22233
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Lauda WK 1200 Recirculating Chiller

    Lauda WK 1200 Recirculating Chiller

    Cambridge ID #: 21271

    Features:

    •  Brinkmann Lauda WK 1200 Circulation Chiller 

    Specifications:

    • Working temperature range (°C): 0-40
    • Temperature stability (±K): 0.5
    • Cooling output at 20 °C: 1.2kW
    • Pump pressure max.: 3.2 bar
    • Pump flow max.: 40 L/min

     

    Learn More
    Lauda-WK-1200-Recirculating-Chiller-21271
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR 1130-2S Recirculating Waterbath

    VWR 1130-2S Recirculating Waterbath

    Cambridge ID #: 19071

    Features:

     

    Microprocessor controller with LED set-and-read at an attractive price makes this model an excellent overall value. The bright LED display is easy to read and continuously displays actual temperature. The set temperature is displayed at the touch of a button. The 2-speed pressure (simplex) pump is used for closed-loop applications

     

    Specifications:

    Capacity: 6 liters

    • Temperature Range: Ambient + 5°C to 150°C
    • 120V
    • 60Hz
    • Reservoir Capacity: 28 liters
    • Pressure Flow Rate: 2-speed (Simplex Pump), 7 or 15 liters/min.
    • Working Access,L x W x D 12-1/8 x 10-3/4 x 8 in. 30.8 x 26.4 x 20.3 cm



    Learn More
    VWR-1130-2S-Recirculating-Waterbath-19071
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Neslab GP-400 Recirculating Heated Waterbath

    Neslab GP-400 Recirculating Heated Waterbath

    Cambridge ID #: 14896

    Neslab GP-400 water recirculating heater circulator immersion bath. The GP-400 recirculating heated water bath is designed to provide temperature control for applications requiring a fluid work area or pumping to an external system.

    Specifications:

    • Dimensions: 25 x 12.5 x 28.25 in
    • Interior Bath Dimensions:20 x 10.325 x 5.75 in
    • Bath Capacity:5 gallons
    • Power Requirements: 115V, 60Hz, 11.5A
    Learn More
    Neslab-GP-400-Recirculating-Heated-Waterbath-14896
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

    Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 22474, 14777, 15508, 15356, 15353, 17335, 16030, 15999, 15289

    Specifications:

    • Autosampler Thermostat
    • Operating temp range: 4 to 40°C (39 to 104°F)
    • Operating humidity range: < 95%, non-condensing
    • Maximum Power Consumption [VA]: 260 VA
    • Maximum Power Consumption [W]: 210 W
    • BTU: 717

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22474
    By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
    Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

    Hewlett Packard 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 22471, 22466

    Specifications:

    • Autosampler Thermostat
    • Operating temp range: 4 to 40°C (39 to 104°F)
    • Operating humidity range: < 95%, non-condensing
    • Maximum Power Consumption [VA]: 260 VA
    • Maximum Power Consumption [W]: 210 W
    • BTU: 717

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Hewlett-Packard-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-22471
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 17699, 16315, 22332, 22112, 16338, 24125, 23205, 17972

    Specifications:

    • Autosampler Thermostat
    • Operating temp range: 4 to 40°C (39 to 104°F)
    • Operating humidity range: < 95%, non-condensing
    • Maximum Power Consumption [VA]: 260 VA
    • Maximum Power Consumption [W]: 210 W
    • BTU: 717

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699
    By clicking below we can further assist you with your inquiry. Inquire 8 In Stock Worldwide Shipping
    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 21014, 22330, 23961, 23159, 24073

    The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

    Specifications:

    • Weight: 20.7 kg (45.6 lbs)
    • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
    • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
    • Line Frequency: 50 or 60 Hz, ± 5 %
    • Power consumption Autosampler: 300 VA 
    • ALS Thermostat: 260 VA
    Learn More
    Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-21014
    By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
    Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Agilent 1290 Series - G1330B HPLC Autosampler Chiller / Thermostat

    Cambridge Scientific ID #'s: 20569, 20795

    Features:

    The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials

    Specifications:

    • Temperature Range: Settable from 4 °C to 40 °C in 1 ° increments
    • Temperature Accuracy at Ambient
      • Temperatures < 25 °C and humidity < 50 %: 3 °C to 8 °C at a setpoint of 4 °C*
    • Temperature Accuracy at Ambient Temperatures
      • temperatures  < 30 °C and humidity < 60 %: 3 °C to 9 °C at a setpoint of 4 °C*
    Learn More
    Agilent-1290-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-20569
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
     minichiller Chiller

    minichiller Chiller

    Cambridge ID #: 21998
  • Model: Minichiller
  • Order No: B02010003
  • Description: Water Cooler
  • Operating Temperature Range: -20...40-Degrees Centigrade
  • Display: Digital
  • Refrigeration Machine: Air Cooled, Natural Refrigerant
  • Refrigerant Type: R290
  • Refrigerant Quantity: 0.04 kg
  • Power Requirements: 115VAC 60Hz 4.0A
  • Learn More
    -minichiller-Chiller-21998
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series HPLC System

    Agilent 1100 Series HPLC System

    Cambridge ID #: 9592

    Optional Installation, Familiarization, and Extended Warranty available

     

    Includes:

    • G1322 Degasser
    • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
    • G1329A Autosampler
    • G1330 Autosampler Chiller
    • G1316A Column Compartment
    • G1315A Diode Array Detector
    • Computer Loaded with ChemStation
    • Monitor – Mouse – Keyboard
    • Cables and Manuals

     

    The components can be customized to your needs.

     

    Please let me know if I can be of any additional assistance.

    Learn More
    Agilent-1100-Series-HPLC-System-9592
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1329A HPLC Autosampler

    Agilent 1100 Series - G1329A HPLC Autosampler

    Cambridge Scientific ID #'s: 23206, 19935, 17476, 17331, 16037

    Specifications:

    • Autosampler (Chiller Compatible)
    • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
    • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
    • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
    • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
    • Replicate injections: 1– 99 from one vial
    • Precision:
      • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
      • Typically < 1 % RSD of peak areas from 1 – 5 µl
    • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
    • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
    • Sample viscosity range: 2 – 50 cp
    • Replicate injections per vial: 1 – 99
    • Sample capacity:
      • 100 × 2-ml vials in 1 tray
      • 40 × 2-ml vials in ½ tray
      • 15 × 6-ml vials in ½ tray (Agilent vials only)
    • Injection cycle time: Typically 50 s depending on draw speed and injection volume

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1329A-HPLC-Autosampler-23206
    By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping