Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Robotic Liquid Handler: 31-45 of 337

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1323B HPLC Communication Module

Agilent 1100 Series - G1323B HPLC Communication Module

Cambridge Scientific ID #'s: 16043, 15085

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1329A HPLC Autosampler

Agilent 1100 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 15502, 19935, 15503, 17476, 17331, 16037

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1329A-HPLC-Autosampler-15502
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16189, 14777, 15501, 15508, 15189, 15356, 15353, 17335, 16030, 15504, 15999, 21296, 15289

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-16189
By clicking below we can further assist you with your inquiry. Inquire 13 In Stock Worldwide Shipping
Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 17699, 17974, 16315, 15223, 16338, 17972

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-17699
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1100 Series - G1361A HPLC Preparative Pump

Agilent 1100 Series - G1361A HPLC Preparative Pump

Cambridge Scientific ID #'s: 18544, 18566, 18543

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry

 

Can be sold as an individual component or as part of a complete stack

 

Learn More
Agilent-1100-Series---G1361A-HPLC-Preparative-Pump-18544
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17966, 17971, 13182, 16326

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17966
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 21294

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications Controller: area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features:  Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:  
    • 1 – 100 μl in 0.1 μl increments
    • Up to 1500 μl with multiple draw (hardware modification required)
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 μl,
    • Typically < 1 % RSD from 1 – 5 μl
  • Sample viscosity range:  0.2 – 5 cp
  • Sample capacity:
    • 2 × well-plates (MTP) + 10 × 2 ml vials
    • 100x2ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically < 30 s using following standard conditions:
    • Default draw speed: 200 μl/min
    • Default eject speed: 200 μl/min
    • Injection volume: 5 μl
  • Carry-over Typically:
    • < 0.01 % using the following conditions:
    • Column: 125 x 4 mm Hypersil ODS, 5 μm
    • Mobile phase: Water/Acetonitrile = 80/20
    • Flow rate: 1 ml/min
    • Injection volume: 1 μl caffeine (1 mg/ml), 5 μl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port

 

Learn More
Agilent-1100-Series---G1367A-HPLC-Well-Plate-Autosampler-21294
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1376A HPLC Capillary Pump

Agilent 1100 Series - G1376A HPLC Capillary Pump

Cambridge Scientific ID #'s: 9564, 15081, 17698

Specifications:

  • Hydraulic system: Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min
  • Settable column flow Range:
    • – 20 µl/min
    • – 100 µl/min (with the extended flow range kit)
    • – 2.5 µl/min (with the electronic flow control bypassed)
  • Recommended column flow range:
    • – 20 µl/min
    • 10 – 100 µl/min (with extended flow range kit)
    • – 2.5 ml/min (with the electronic flow sensor bypassed)
  • Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting)
  • Optimum composition Range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater
  • Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting
  • Delay volume:
    • Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min.
    • Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl.
    • for flow rates up to 100 µl/min and electronic flow control active:
    • primary flow path 180 - 480 µl without mixer, 600 - 900 µl with mixer (system pressure dependent)
    • Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl)
  • Pressure range: 20 to 400 bar (5880psi) system pressure
  • Compressibility Compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH Range: 0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog output For pressure monitoring, 2 mV/bar, one output
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.
  • Housing: All materials recyclable
Learn More
Agilent-1100-Series---G1376A-HPLC-Capillary-Pump-9564
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Cambridge ID #: 13766

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • – 8 µl in 0.01 µl increments with the small loop capillary
    • – 40 µl in 0.01 µl increments with the extended loop capillary
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 40 µl,
    • Typically < 1 % RSD from 1 – 5 µl
    • Typically < 3 % RSD from 0.2 – 1 µl
  • Sample viscosity range: 2 – 5 cp
  • Sample capacity:
    • 2× well-plates (MTP) + 10 × 2 ml vials
    • 100 x 2 ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically, < 30 s using following standard conditions:
    • Default draw speed: 4 µl/min
    • Default eject speed: 10 µl/min
    • Injection volume: 0.1 µl
  • Carry-over:
    • Typically < 0.05 % using the following conditions:
    • Column: 150 x 0.5 mm Hypersil ODS, 3 µm
    • Mobile phase: Water/Acetonitrile = 85/15
    • Column Flow rate: 13 µl/min
    • Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port
Learn More
Agilent-1100-Series---G1377A-HPLC-Well-Plate-Autosampler-13766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 19163, 15934, 16078, 18444, 16060, 16141, 10201, 16316, 16327

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-19163
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Agilent 1100 Series - G1389A HPLC Autosampler

Agilent 1100 Series - G1389A HPLC Autosampler

Cambridge Scientific ID #'s: 9301, 16033, 10407

Specifications:

  • Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
  • Settable injection volume
    • to 8 µl with small loop capillary
    • to 40 µl with extended loop capillary
  • Precision
    • Typically < 0.5 % RSD from 5 to 40 µl
    • Typically < 1 % RSD from 1 to 5 µl
    • Typically < 3 % RSD from 0.2 to 1 µl
  • Minimum sample volume: µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
  • Carryover
    • Typically < 0.1 % without automated needle wash
    • Typically < 0.05 % with external needle cleaning and 1 µl injection volume
  • Sample viscosity range: 2 - 5 cp
  • Recommended pH-range: - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries
  • Material in contact with solvent: Stainless steel, sapphire, PTFE, PEEK, fused silica
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in aintenance areas, error detection and display
  • Housing: All material recyclable

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1389A-HPLC-Autosampler-9301
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping