We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Sample Prep Workstation: 1-15 of 279

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Qiagen QiaSymphony AS/SP Sample Prep Workstation

Qiagen QiaSymphony AS/SP Sample Prep Workstation

Cambridge ID #: 19462

With a dedicated range of QIAsymphony Kits, the QIAsymphony AS/SP enables sample preparation of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials. The QIAsymphony AS extends the capabilities of the QIAsymphony SP by integrating automated PCR assay setup, which, in combination with the Rotor-Gene Q and QIAGEN real-time and end-point PCR kits, enables you to optimize your PCR workflow and maximize your efficiency.

Specifications:

  • This system includes the Rotor-Gene Q
  • Altitude: Up to 2000 m
  • Elution Volume: 30 – 500 uL
  • Humidity: 15-75% (relative, noncondensing), maximum 75%
  • Input Volume: 200 uL
  • Dimensions: 128 x 103 x 73 cm
  • Operating Temperature: 15 - 32°C
  • Power Requirements: 100-240V, 50/60Hz
  • Storage Temperature: 5 - 40°C
Learn More
Qiagen-QiaSymphony-AS-SP-Sample-Prep-Workstation-19462
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Sample manager UPLC Sample Manager

Waters Acquity Sample manager UPLC Sample Manager

Cambridge Scientific ID #'s: 15340, 15769

Specifications:

  • Number of sample plates: Total of two plates, expandable to up to 22 plates with optional Sample Organizer (see below):
    • 96 and 384 microtiter plates
    • 48 position 2.00-mL vial plates
    • 48 position 0.65-mL micro-centrifuge tube plates
    • 24 position 1.50-mL micro-centrifuge tube plates
  • Maximum sample capacity: 768 in two 384-well plates; expandable to up to 8,448 samples with optional Sample Organizer
  • Number of sample injections: 1 to 99 injections per sample
  • Injection volume range: 0.1 to 50.0 iJL, in 0.1 iJL increments, partial or full loop mode; 10ul loop is standard; 1, 2, 5, 20, and 50-uL loops also available
  • Sample delivery precision(full loop injection mode): < 0.3% RSO, full loop, standard lO-iJL loop (default wash/purge conditions), per Waters AQT/SystemsQT protocol
  • Sample delivery precision(PLNO injection mode): < 1% RSO within 20% to 75% of loop volume for 1, 2, 5, 10, 20, and 50-iJL loops, UV detection
  • Injector linearity: > 0.999 coefficient of deviation (from 20% to 75%, partial loop overfill mode (PLNO injection mode), per Waters' AQT/SystemsQT protocol
  • Sample temperature control:0 to 40.0 ·C, settable in 0.1 ·C increments (assumes an ambient temperature of 25.0 ·C). At an ambient temperature of 21.0 ·C or lower the sample manager will maintain the temperature of the sample compartment down to 4.0 ·C with a tolerance of -2.0/+6.0 ·C, when configured with the maximum number of vials and/or plates
  • Injection cycle time:
    • < 15 sec between multipe injections with "load ahead" enabled
    • 30 sec with single weak wash, lO-iJL loop, pressure assist mode
  • Sample probe: XYZZ based needle-in-needle design
  • Minimum sample required: 5 uL residual, using maximum recovery 2-mL vials (zero offset)
  • Wash solvents: Two degassed: strong solvent and weak wash solvent, programmable to suit application
  • Sample carryover: < 0.005% or < 2.000 nL, whichever is greater
  • Advanced operations: Loop off-line mode, load ahead
  • Unattended operation: Leak sensors, full diagnostic data control captured through console software
  • Primary wetted material: Titanium alloy, 316 stainless steel, fluoropolymer, fluoroelastomer, PPS alloy, PEEK alloy, PPS, PEEK, OLC coating, gold
Learn More
Waters-Acquity-Sample-manager-UPLC-Sample-Manager-15340
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Labconco 6941003 Protector WorkstationImage Coming Soon

Labconco 6941003 Protector Workstation

Cambridge ID #: 12941

Description:

  • Designed to duct to the outside from one of four exhaust connections.
  • For use with remote blower.
  • Adjustable baffle.
  • Pre-wired for operation on 115 volts, 60 Hz, 15 amps.
  • 8', three-wire cord with plug.
  • Three each 3.25" x 10" exhaust connections located on the top and both sides.
  • 6" nominal diameter exhaust connection located on the back.
  • Static pressure loss does not exceed .28" H2O at 50 fpm (167 CFM).
Learn More
Labconco-6941003-Protector-Workstation-12941
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Erlab Captair Bio 321 *NEW* PCR Workstation

Erlab Captair Bio 321 *NEW* PCR Workstation

Cambridge ID #: 17650

Features:

Samples preparation before thermocycling. Ideal for applications like post PCR DNA sequencing revelation / separation, In Vitro fecundation, cellular cultures, and Vegetal Biology.

 

Specifications:

 

  • External Dimensions (W x D x H): 32” 1/4 x 24” 3/4 x 34” 7/8 mini, 38” maxi
  • Internal Dimensions (W x D x H): 30” 1/8 x 21” 5/8, 20” 11/16
  • Metallic Parts: Anti-corrosion steel coated with 100% polyester
  • Side and Front Panels: Synthetic glass Thickness (0.39 inch) adapted for the user protection against rays (Beta) (32P: Phosphorus - 14C: Carbon - 14 3H: Tritium)
  • Ventilation Module: Injected polypropylene
  • Number of Fans (IP44): 1
  • Processed Air Flow: 118 CFM
  • Number of HEPA H14 Filter: 1
  • Number of Optional Molecular Carbon Filters: 1
  • Number of UV Lamp: 1
  • Number of Compact Tubular Fluorescent Lighting: 1
  • Voltage / Frequency: 230V / 50-60Hz
  • Total Power Consumption Max Including Electricity For the Lights: 75W
  • Amperage Absorbed: 0.32 A
  • Bactericidal UV Lamps: 15W - Wavelength : 254 nm
  • UV cut-off: Automatic shut off of the UV lamp when the front shield is opened
  • UV Timer: UV timer set up : from 1 to 30 minutes
  • Flow Monitor: Permanent ventilation control device
  • Energy Ports: For the passage of cables
  • Internal Lightning: Compact tubular fluorescent lightning - 18 Watts - 500 Lux - IP67
  • Particular Pre-Filter: Protect HEPA and molecular filters from dust contained into the laboratory environment
Learn More
Erlab-Captair-Bio-321-*NEW*-PCR-Workstation-17650
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Erlab Captair Bio 391 *NEW* PCR Workstation

Erlab Captair Bio 391 *NEW* PCR Workstation

Cambridge ID #: 17651

Features:

Samples preparation before thermocycling. Ideal for applications like post PCR DNA sequencing revelation / separation, In Vitro fecundation, cellular cultures, and Vegetal Biology.

 

Specifications:

  • External Dimensions (W x D x H): 40” 9/16 x 24” 3/4 x 37” 1/4 mini x 40” 3/8 maxi
  • Internal Dimensions (W x D x H): 38” 3/16 x 21” 7/8 x 23” 7/16
  • Metallic Parts: Anti-corrosion steel coated with 100% polyester
  • Side and Front Panels: Synthetic glass thickness (0.39 inch) adapted for the user protection against rays (Beta) (32P: Phosphorus - 14C: Carbon - 14 3H: Tritium)
  • Ventilation Module: Injected polypropylene
  • Number of Fans (IP44): 1
  • Processed Air Flow: 141 CFM
  • Number of HEPA H14 Filter: 1
  • Number of Optional Molecular Carbon Filters: 1
  • Number of UV Lamp: 2
  • Number of Compact Tubular Fluorescent Lighting: 1
  • Voltage / Frequency: 230 V / 50-60Hz
  • Total Power Consumption Max Including Electricity for the Lights: 75 W
  • Amperage Absorbed: 0.32 A
  • Bactericidal UV Lamps: 15W - Wavelength : 254 nm
  • UV cut-off: Automatic shut off of the UV lamp when the front shield is opened
  • UV Timer: UV timer set up : from 1 to 30 minutes
  • Flow Monitor: Permanent ventilation control device
  • Energy Ports: For the passage of cables
  • Internal Lightning: Compact tubular fluorescent lightning - 18 Watts - 500 Lux - IP67
  • Particular Pre-Filter: Protect HEPA and molecular filters from dust contained into the laboratory environment
Learn More
Erlab-Captair-Bio-391-*NEW*-PCR-Workstation-17651
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Erlab Captair Bio 712 *NEW* PCR Workstation

Erlab Captair Bio 712 *NEW* PCR Workstation

Cambridge ID #: 17652

Features:

Samples preparation before thermocycling. Ideal for applications like post PCR DNA sequencing revelation / separation, In Vitro fecundation, cellular cultures, and Vegetal Biology.

 

Specifications:

 

  • External Dimensions (W x D x H): 69” 11/16 x 24” 3/4 x 37” 1/4 mini x 40” 3/8 maxi
  • Internal Dimensions (W x D x H): 67 5/16” x 21” 7/8 x 23” 7/16
  • Metallic Parts: Anti-corrosion steel coated in 100% polyester
  • Side and Front Panels: Synthetic glass thickness (0.39 inch) adapted for the user protection against rays (Beta) (32P: Phosphorus - 14C: Carbon - 14 3H: Tritium)
  • Ventilation Module: Injected polypropylene
  • Number of Fans (IP44): 2
  • Processed Air Flow: 252 CFM
  • Number of HEPA H14 Filter: 2
  • Number of Optional Molecular Carbon Filters: 2
  • Number of UV Lamp: 3
  • Number of Compact Tubular Fluorescent Lighting: 2
  • Voltage / Frequency: 230 V / 50-60Hz
  • Total Power Consumption Max Including Electricity for the Lights: 150 W
  • Amperage Absorbed: 0.65 A
  • Bactericidal UV Lamps: 15W - Wavelength : 254 nm
  • UV cut-off: Automatic shut off of the UV lamp when the front shield is opened
  • UV Timer: UV timer set up : from 1 to 30 minutes
  • Flow Monitor: Permanent ventilation control device
  • Energy Ports: For the passage of cables
  • Internal Lightning: Compact tubular fluorescent lightning - 18 Watts - 500 Lux - IP67
  • Particular Pre-Filter: Protect HEPA and molecular filters from dust contained into the laboratory environment
Learn More
Erlab-Captair-Bio-712-*NEW*-PCR-Workstation-17652
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Agilent 1100 Series - Prep HPLC Stack  HPLC Preparative System

Agilent Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 18658

Includes:

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Dual Loop Autosampler (Manual Injector also an option)
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

G1361 Prep Pump

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry
Learn More
Agilent-Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-18658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Genevac EZ-2 PLUS Sample Concentrator

Genevac EZ-2 PLUS Sample Concentrator

Cambridge ID #: 19750

Genevac designed the EZ-2plus with the specific requirements of lead optimization in mind. Years of experience in solvent evaporation and sample purification allow Genevac to produce a high-efficiency sample concentrator that is high performance, easy to use, very reliable and compatible with almost all commonly used solvents and acids.

 

The EZ-2 Series is the culmination of an extensive research and development program that draws on the expertise of Genevac’s engineers and the experiences of many scientists in the laboratory. Using the most advanced  proven technology in evaporation science, the EZ-2 Series has been designed specifically for solvent removal in life science research, be that concentration of samples or complete drying. Genevac’s fifteen years of experience in vacuum engineering has resulted in the creation of a compact sample concentrator combining great performance, ease of use greater than a rotary evaporator and compatibility with all commonly used solvents and acids.

Learn More
Genevac-EZ-2-PLUS-Sample-Concentrator-19750
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Sample Organizer UPLC Autosampler Loader

Waters Sample Organizer UPLC Autosampler Loader

Cambridge Scientific ID #'s: 14266, 14267, 14268

The ACQUITY UPLC Sample Organizer increases the level of automation and sample processing throughput of the ACQUITY UPLC System. It extends the capacity of the system by more than tenfold for samples in standard ANSI-compliant 96 or 384 well plates; or more than threefold for samples in conventional 2 mL vials.

 

Features:

  • Plates are transferred in a programmable order from the Sample Organizer to the ACQUITY UPLC System Sample Manager for processing
  • Plate exchange shuttle replaces a plate in the Sample Manager within 15 seconds to support high sample-throughput processing
  • Shelves accessed through the large swing-open front door and slide in easily
  • Accepts any combination of ANSI-compliant well plates and vial holders
  • Temperature control of 4 to 40 °C in 1 °C increments
  • Small footprint
  • Sample capacities:
    • 22 standard ANSI/SBS-compliant 96 or 384 well plates
    • 12 intermediate well plates
    • 8 x 48 – 2mL vials
    • 8 x 24 – 4mL vials
Learn More
Waters-Sample-Organizer-UPLC-Autosampler-Loader-14266
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Luminex 100 Microplate Luminescence Reader

Luminex 100 Microplate Luminescence Reader

Cambridge ID #: 18700

The Luminex 100 System is a flexible analyzer based on the principles of flow cytometry. The system enables you to multiplex (simultaneously measure) up to 100 analytes in a single microplate well, using very small samples. The system delivers fast and cost-effective bioassay results on many assay formats including nucleic acid assays, receptor-ligand assays, immunoassays, and enzymatic assays.

Specifications:

  • Multiplexing: up to 100 analytes per sample
  • Dynamic Range: ≥3.5 logs
  • Read Time: 96 well plate in ≤ 45 min (up to 12,800 tests/hour)
  • Daily Start up/Shut down: ≤30 min
Learn More
Luminex-100-Microplate-Luminescence-Reader-18700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1312A HPLC Binary Pump

Agilent 1100 Series - G1312A HPLC Binary Pump

Cambridge Scientific ID #'s: 15626, 7526, 17475, 13985, 16317, 15936, 16119, 12811, 19156, 16034, 8571, 9300, 19155, 13406, 12452

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
By clicking below we can further assist you with your inquiry. Inquire 15 In Stock Worldwide Shipping
Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cambridge ID #: 11053

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge Scientific ID #'s: 9625, 9227, 15384, 7876, 16066, 15175, 16118

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-9625
By clicking below we can further assist you with your inquiry. Inquire 7 In Stock Worldwide Shipping
Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Agilent 1100 Series - G1330A HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 16189, 16031, 17335, 16030, 15999

Specifications:

  • Autosampler Thermostat
  • Operating temp range: 4 to 40°C (39 to 104°F)
  • Operating humidity range: < 95%, non-condensing
  • Maximum Power Consumption [VA]: 260 VA
  • Maximum Power Consumption [W]: 210 W
  • BTU: 717

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1330A-HPLC-Autosampler-Chiller---Thermostat-16189
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping