Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Analyzers ranging from Chemistry Analyzers, Hematology Analyzers, to Glucose/Lactate Analyzers. Some of our popular manufacturers include YSI, Cell-Dyn, and Roche.

Shimadzu: 16-20 of 20

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Shimadzu Prominence Rack Changer/C HPLC Rack Changer

Shimadzu Prominence Rack Changer/C HPLC Rack Changer

Cambridge ID #: 13704

The chilled rackchanger unit exchanges the microplates on autosampler racks to enable samples to be continuously analyzed. 12 plates can be mounted inside the main unit and stored under refrigerated conditions.

 

Specifications:

  • Method: Variable sample injection volume and total volume direct injection
  • Injection Volume Range: 0.1 µL to 100 µL (0.1 µL to 2000 µL with option)
  • Number of Samples Processed:
    • 175 (1-mL vials), 105 (1.5-mL vials), 50 (4-mL vials),
    • 192 (two 96-well MTP/DWP), 768 (two 384-well MTP/DWP)
    • *Twelve 96-well MTP/DWP in the rackchanger
  • Injection Volume Precision: Max RSD 0.3 % (under specified conditions)
  • Cross-Contamination: Max 0.005 % (naphthalene and chlorhexidine)
  • Needle Rinsing: Freely settable, before or after sample injection
Learn More
Shimadzu-Prominence-Rack-Changer-C-HPLC-Rack-Changer-13704
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu SIL-HTC HPLC Autosampler

Shimadzu SIL-HTC HPLC Autosampler

Cambridge ID #: 22317

To be used with a Shimadzu 10 HPLC System

 

Specifications:

  • Sample injection system: Total sample injection, variable sample injection system (zero sample loss during injection)
  • Settable range of injection volumes: to 100 µL (standard), or 1 to 2000 µL (option) (0.1µL steps from 0.1 to 0.9µL, and 1µL steps from 1 to 2000 µL)
  • Sample processing capability:
    • With 1-mL vials: 350
    • With 1.5-mL vials: 140
    • with 4-mL vials:100
    • With micro plates: 4 (96 wells: 284, 284 wells: 1536)
    • with deep well plates: 4 (96 wells: 284, 284 wells: 1536)
  • Injection volume repeatability: RSD: 0.3% max. (at 10µL injection)
  • Cross contamination: 01% max. (for analysis of naphthalene)
  • Injection  volume accuracy:Less than +/- 1% (50µL)
  • Injection volume accuracy correction: Possible
  • of injections: 1-99 times per sample
  • Setting of analysis time: .01– 9999.9 (0.1 minute increments to 999.99 min., 0.1 minutes increments over 1000 min.)
  • Number of steps for injection conditions: Max 102 steps
  • Sample suction speed: 1-15 µL/sec (0.1µL/s step for 0.1-0.9 µL/sec., 1µL/s step for over1 µL/sec.)
  • Rinsing liquid suction speed: 1-35 µL/sec/ (1µL/s step)
  • Maximum pressure: 20.0 Mpa (standard pippings of sample flowpath is PEEK)

Sample cooler (SIL-HTc only)

  • Method: Direct cooling method (at a setting of 4 deg. C, room temperature must be less than 30 deg. Cand humidity less than 70%)
  • Temperature setting range: 4 to 40 deg. (cooling down to 4 deg. C for room temperature up to 30 deg. C and humidity to 70%)
  • Operating ambient temperature range:4 to 35 deg. C
Learn More
Shimadzu-SIL-HTC-HPLC-Autosampler-22317
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu SPD-20A HPLC Detector

Shimadzu SPD-20A HPLC Detector

Cambridge ID #: 22319

The SPD-20A can be used for all UV analysis in the 190 to 700 nm range, while the SPD-20AV at 190-900 nm is available for those that require a detector in the visible region. From superior optics and optical coatings to new signal processing technologies to the implementation of sound chromatographic principles, the Shimadzu Prominence series UV-Vis absorbance detectors give you the performance, stability and ruggedness demanded in today’s fast-paced analytical laboratories. Analysts in a regulated laboratory will appreciate the built-in Mercury vapor lamp to assure wavelength accuracy at the touch of a button, along with many other diagnostic routines for compliance with all of your GMP/GLP operating procedures.

Specifications:

  • Light source: Deuterium (D2) lamp 
  • Number of diode elements: N/A
  • Bandwidth, slit width: 8 nm
  • Wavelength accuracy: 1 nm max.
  • Wavelength precision:  0.1 nm max.
  • Noise: 0.5 X 10-5 AU (under specified conditions)
  • Drift: 1 X 10-4 AU/h (under specified conditions)
  • Linearity: 2.5 AU (ASTM standard)
  • Functions: Dual-wavelength detection in the range 190 to 370 nm and upwards of 371, ratio-chromatogram output, wavelength scanning
  • Cell: Pathlength: 10 mm Volume: 12µL Pressure: 12 MPa
  • Cell temperature-control range: 5o C above room temperature to 50o C
  • Operating temperature range: 4o C to 35o C (non-condensing atmosphere)
  • Dimensions, weight: 260 (W) x 140 (H) x 420 (D) mm, 13 kg
  • Power requirements: 100 VAC, 160 VA, 50/60 Hz
Learn More
Shimadzu-SPD-20A-HPLC-Detector-22319
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Shimadzu UVmini-1240 Spectrophotometer UV/Vis Reader

Cambridge ID #: 18159

Specifications:

 

Site Requirements

  • Dimensions (W x D x H): 416 × 379 × 274mm
  • Weight: 11 kg
  • Ambient temperature: 15 to 35°C
  • Ambient humidity: 45 to 80%, less than 70% if over 30°C
  • Power supply: 100~120 V 50/60 Hz 160 VA ; 220~240 V 50/60 Hz 160 VA

Performance Specifications:

  • Spectrum bandwidth: 5 nm
  • Wavelength accuracy: ± 1.0 nm
  • Wavelength repeatability: ± 0.3 nm
  • Stray light: less than 0.05% (220.0 nm Nal, 340.0 nm NaNO2 & UV39)
  • Photometric range: −3.99 to 3.99 Abs (absorbance) ;  0.0 to 200% (transmittance)
  • Recording range: −3.99 to 3.99 Abs (absorbance) ;  −399 to 399% (transmittance)
  • Photometric accuracy: ± 0.005 Abs (at 1.0 Abs) ; ± 0.003 Abs (at 0.5 Abs)
  • Photometric repeatability: ± 0.002 Abs (at 1.0 Abs)
  • Drift: less than ± 0.001 Abs/h (after 2 hr warm-up)
  • Baseline flatness: ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm)
  • Noise: less than 0.002 Abs, Peak to Peak / less than 0.0005 Abs, RMS

Optical Design

  • Wavelength range: 190.0 to 1100.0 nm
  • Display wavelength: 0.1nm step
  • Selectable wavelength: 0.1 nm step (1 nm step in spectrum mode)
  • Scan speed: ± 3800 nm/min (wavelength change) ; ± 24 to 1400 nm/min (scan)
  • Light source change: Auto change with wavelength ; halogen lamp only ; deuterium (D2) lamp only
  • Measurement method: single beam measurement
  • Monochromator: incorporates aberration-corrected concave blazed holographic grating
  • Detector: silicon photodiode
Learn More
Shimadzu-UVmini-1240-Spectrophotometer-UV-Vis-Reader-18159
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu XRD-6000

Shimadzu XRD-6000

Cambridge ID #: 22735

With its basic ease of use and abundant functions, the XRD-6000 boasts an integrated design featuring a vertical goniometer and data processing software supporting the Windows XP user interface.

The XRD-6000 offers solutions encompassing wide-ranging analysis requirements, from routine qualitative and quantitative analysis to state change analysis, including stress analysis, residual austenite quantitation, crystallite size / lattice strain, crystallinity calculation, materials analysis via overlaid X-ray diffraction patterns, enhanced material evaluation and sample heating analysis. And, of course, crystalline structural analysis is also supported, including precise lattice constant determination and crystal system determination.

Learn More
Shimadzu-XRD-6000--22735
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping