Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21357

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21357
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3F *NEW* Atomic Absorption Spectrophotometer

Persee A3F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21355

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3F-*NEW*-Atomic-Absorption-Spectrophotometer-21355
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee A3G *NEW* Atomic Absorption Spectrophotometer

Persee A3G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21356

Features:

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

â—† Easy to use, complete software control

â—† Integrated safety precautions for user protection

â—† Flexible configuration for a wide array of industrial apps

â—† Time-saving high speed analysis

 

Specifications:

Spectrometer System

  • Model:Flame AA System-A3F, Graphite AA System-A3G, 

    Combined Flame and Graphite Furnace AA System-A3FG

  • Wavelength range: 190-900 nm
  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  • Modulation: Square wave pulse
  • Modulation frequency:
    • 100 hz self reversal (SR) background
    • 400 hz Deuterium Arc (D2) background

Monochromator 

  • Grating: 1800 grooves/mm diffraction grating
  • Blazed: wavelength 250 nm
  • Focus: 300 nm
  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
  • Scan mode: Automatic
  • Photometric type: Single beam
  • Wavelength accuracy: ±0.15 nm
  • Wavelength resolution: 0.2 nm±0.02 nm
  • Wavelength reproducibility: <0.05 nm
  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
  • Baseline stability: 0.005 A/30 min
  • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

Graphite Furnace Analysis

  • Graphite head: Transversally heated
  • Temperature range: Ambient-2650 ℃
  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  • Feedback : Voltage and optical temperature control feedback
  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
  • Detection limit: Cd<0.004 ng/ml
  • Repeatability:
    Cu<2.0 % , Cd<2.0 %
  • Graphite tubes: Pyrolytically coated with platform
  • Sample size: Up to 20μl
  • Graphite cooling: Water circulator available
Learn More
Persee-A3G-*NEW*-Atomic-Absorption-Spectrophotometer-21356
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21354

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21354
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Persee AA990F *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21352

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Persee AA990G *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21353

Features:

 

The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

AA990F-Flame atomizer only.

AA990G-Graphite furnace atomizer only. 

AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

â—† Easy-to-use automation software 

â—† Integrated safety precautions for user protection

â—† Precision accuracy with integrated correction system 

â—† Life cycle value, best choice for less than 8 elements of analysis

 

Specifications:

  • Wavelength range: 190-900 nm

  • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

  • Modulation: Square wave pulse

  • Modulation frequency :

    100 Hz self reversal (SR) background,

    400 Hz Deuterium Arc (D2) background

  • Monochromator

  • Grating: 1800 grooves/mm diffraction grating

  • Blazed wavelength: 250 nm

  • Focus: 300 nm

  • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

  • Scan mode: Automatic

  • Photometric type: Single beam

  • Wavelength accuracy: ±0.15 nm

  • Wavelength resolution: 0.2 nm±0.02 nm

  • Wavelength reproducibility: <0.05 nm

  • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

  • Baseline stability: 0.005 A/30 min

  • Background correction:
    Deuterium Arc (D2) 1.0 Abs,

    Self Reversal (SR) 3.0 Abs

     

    Flame Analysis

  • Flame type: Air/acetylene

  • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

  • Characteristic Concentration: Cu<0.02 μg/ml

  • Detection limit: Cu<0.004 μg/ml
    Repeatability: Cu<0.7 %

  • Burner head: Titanium Alloy

     

  • Nebulizer:
    High–efficiency glass,

    acid proof available as an option

    Pre-mix chamber: Corrosion resistant

  • Atomizer selection:

    Manual (AA990F)
    Automatic changeover (AA990FG)

  • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


    Graphite Furnace Analysis

  • Graphite head: Transversally heated

  • Temperature range: Ambient-2650 ℃

  • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

  • Feedback: Voltage and optical temperature control feedback

  • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

Learn More
Persee-AA990G-*NEW*-Atomic-Absorption-Spectrophotometer-21353
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Cary Eclipse Fluorescence Spectrophotometer

Agilent Cary Eclipse Fluorescence Spectrophotometer

Cambridge ID #: 21019

Features:

  • Multiple collection modes: Fluorescence, phosphorescence, chemi/bio-luminescence, and time resolved phosphorescence measurements can all be easily made without changing a single hardware component
  • Lowest cost of ownership: The Cary Eclipse is so robust and reliable that every new instrument comes with a 10-year lamp life guarantee, reducing ongoing expenses to virtually zero. 
  • Improved laboratory safety: Additionally the guaranteed exceptionally long lifetime of the lamp in the Cary Eclipse eliminates lamp replacements, a hugely time-consuming and potentially hazardous operation.
  • Easy to use: Modular, application-specific software, which satisfies the needs of novice and expert users alike, and the ability to switch between measurement modes without touching the hardware, ensure that any user can quickly get reliable, accurate results with minimal training.
  • Expand your analytical capabilities: The superior, unique design of the Cary Eclipse ensures room light immunity allowing the instrument to operate with the front and top panels removed for easy access to sample and fast installation of large accessories.
  • Proven sensitivity where you need it most: Optimized design coupled with unique, high-sensitivity optics and detectors ensure that the Cary Eclipse gives you the performance that you need right across the spectrum. 
  • Robustness, reliability and sensitivity: Engineered to be the most robust instrument on the market, the Cary Eclipse incorporates the unique Agilent xenon flash lamp to capture a data point every 12.5 ms and scans at 24,000 nm/min without peak shifts perfect for high throughput laboratories and fast kinetics applications.
  • Unique Sampling: By incorporating Agilent’s unique capacity to guarantee room light immunity coupled with the highly accurate and reproducible Peltier temperature control, the Cary Eclipse delivers unique sampling opportunities that will expand your analytical capabilities, simplify your workflow and increase your sample throughput.
  • Reliable Results: The Cary Eclipse only illuminates the sample when data is actually being acquired. This means that the Cary Eclipse prevents your valuable samples from photodegradation and preserves their integrity to the point that you can measure them over and over again and continue to get the same, reliable result. 

Specifications:

  • Dimensions(WxDxH): 60 x 64 x 27 cm (23 x 25 x 10 inches)
  • Sensitivity:> 500:1 RMS, 500 nm excitation, excitation and emission slits 10 nm / > 750:1 RMS, 350 nm excitation, excitation and emission slits 10 nm
  • Wavelength(s):190 - 1100 nm
  • Temperature Range: 10 – 35°C
  • Optical System: Cerny-Turner 0.125 m Monochromators
  • Light Source: Xenon Flash Lamp
  • Software: Cary Eclipse Software
Learn More
Agilent-Cary-Eclipse-Fluorescence-Spectrophotometer-21019
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Nicolet 6700 FT-IR Spectrophotometer

Thermo Nicolet 6700 FT-IR Spectrophotometer

Cambridge ID #: 19989

Nicolet 6700 Analytical FTIR Spectrometer with sample holder and a polarized KRS-5.

 

Nicolet FT-IR spectrometers from Thermo Electron Corporation are the highest performance

FT-IR systems available. While the spectrometer has the power to handle the most

advanced research-level experiments, routine analyses are performed just as conveniently.

Every facet of the Nicolet FT-IR spectrometer has been engineered to facilitate sample

handling, introduce options to scientists, and increase laboratory throughput.

Learn More
Thermo-Nicolet-6700-FT-IR-Spectrophotometer-19989
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Buchi NIRFlex N-500 FT-NIR Spectrophotometer

Buchi NIRFlex N-500 FT-NIR Spectrophotometer

Cambridge ID #: 13203

Description: With its dedicated operator interchangeable measurement cells to accommodate many different sample types, the NIRFlex N-500 is a uniquely, flexible FT-NIR Spectrometer. Its Fourier Transform polarization technology guarantees the same superior performance across different environmental conditions; from laboratory to warehouse.

 

Specifications:

 

  • Dimensions (W x D x H): 350 x 250 x 450 mm
  • Spectral range: 800 - 2500 nm (if not specified differently for measuring cell)
  • Resolution: 8 cm−1 (with boxcar apodization)
  • Type of interferometer: Polarization interferometer with TeO2 wedges
  • Wavenumber accuracy: ± 0.2 cm−1 (measured with HF gas cell at an ambient temperature of 25℃ ± 5℃)
  • Signal-to-noise ratio: 10000 (peak-to-peak noise of a linear corrected baseline)
  • Number of scans/sec.: 2 - 4 (depends on resolution)
  • Type of lamp/lifetime lamp (MTBF): Tungsten halogen lamp / 12000 h (2 x 6000 h)
  • Type of laser: 12 VDC HeNe, wavelength at 632.992 nm
  • Analog digital converter: 24 bit
  • Electric power supply: 100 - 230 VAC ± 10%, 50/60 Hz, 350 W

 

  • Ethernet connection: 100 Mbit/s
Learn More
Buchi-NIRFlex-N-500-FT-NIR-Spectrophotometer-13203
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Persee PF7 *NEW* Atomic Absorption Spectrophotometer

Persee PF7 *NEW* Atomic Absorption Spectrophotometer

Cambridge ID #: 21358

Features:

The heavy metal analyzer PF7 features good accuracy, high sensitivity, simple structure, small volume and easy operation.  The automated PF7 is an ideal supplementary of ICP-MS if testing dozens of elements in ULTRA trace elements. A perfect replacement of ICP-MS if only testing heavy metals like Arsenic, Mercury, Cadmium and Lead. Popular instruments in various market and research industries including: Cannabis, Environment (Water and Soil), Agricultural, Public health, Pharmaceutical, Metallurgical, Food and beverage, Clinical, Geological, Petrochemical, and more. Also it comes with XYZ axis auto sampler AS4 as an optional accessory making the analysis even simpler.

â—† Pre-aligned whole system: For the perfect running condition, plug and play

â—† Free-adjustment and data coded high performance lamps: achieve better sensitivity and accuracy

â—† Up to 3 testing channels: For simultaneous analysis, high efficiency

â—† Fully sealed reagent system: Inorganic and organic waste dispose separately, build-in toxic elements trap devices, green laboratory, care for the health

â—† Gas-driven flow system: Without consumable parts, auto purge, chemical resistant FEP tubing, easy to maintenance

â—† High grade automation/intelligent: Auto sampler, Auto dilution, auto optimized

â—† Double beam optical system: To eliminate light source drift

â—† New design Gas Liquid Separator: With magnetic stirring and Peltier system for improved repeatability of analytical results and high sensitivity

â—† Easy to upgrade: Speciation system accessory, compatible with multi brand HPLC pump

 

Specifications:

  • Atomiser: Quartz furnace tube with auto ignition
  • Furnace Heating: Computer controlled heating
  • Hydride Generator: Continuous flow high performance for cold vapour Mercury and hydride determinations of As, Se, Te, Bi, Sb, Sn, Zn, Pb, Cd, Ge
  • Gas Requirement: High purity Argon gas (>99.99 %) @ 30 psi
  • Exhaust System: 2 stage filtration to decontaminate pollutants
  • Carrier and Reagent Delivery: Gas pressure driven system
  • Gas/Liquid Separator:  High efficiency gas/ liquid separator with magnetic stirring and Peltier cooling
  • Baseline Stability: <1.5 %
  • Baseline Noise: <1.5 %
  • Linear Range: >10³
Learn More
Persee-PF7-*NEW*-Atomic-Absorption-Spectrophotometer-21358
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Victory Scientific Picodrop *NEW* Microliter Spectrophotometer

Victory Scientific Picodrop *NEW* Microliter Spectrophotometer

Cambridge ID #: 21048

Features:

  • Quantify RNA, DNA and Proteins in just 3 seconds
  • Low operating costs
  • Measures nucleic acid samples down to 3 ng/μl, and proteins to 0.1 mg/ml
  • Tests samples in volumes as low as 1 - 2 μl - no need to dilute!
  • Purchase includes P10 micropipette and a box of 96 UVpette tips
  • No additional calibration needed (auto calibrating)
  • Zero cross contamination and recover 100% of sample

Specifications:

  • Light Source: Pulsed Xenon
  • Detector: UV coated CCD with 2048 pixels
  • Absorbance Range: 0.0 - 25 absorbance units
  • Absorbance Accuracy: 1% (at .76 absorbance at 257 nm)
  • Sample Size: 2.0 ul, absolute volume not critical, max. 10 ul, accuracy of pipetting not critical
  • Resolution: 3 nm (wavelength resolution FWHM at Hg 546 nm)
  • Wavelength range: 220 - 950 nm
  • W×D×H: 14×27×38 cm
Learn More
Victory-Scientific-Picodrop-*NEW*-Microliter-Spectrophotometer-21048
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Luminex Bio-Plex 3D Microplate Luminescence Reader

Luminex Bio-Plex 3D Microplate Luminescence Reader

Cambridge ID #: 11518

Features:

The Bio-Plex 3D suspension array system is the next generation multiplexing platform based on xMAP technology. Expanded multiplexing capability, faster time to results, and automation capability make it the platform of choice for high-throughput testing for nucleic acid and protein applications.

Specifications:

  • Software: xPONENT (acquisition) Bio-Plex Manager (analysis)
  • Optics: Lasers/APDs/ PMTs
  • Multiplex Capacity: 500
  • Bead Compatibility: MagPlex-C, MicroPlex, LumAvidin, xTAG
  • Read Time: ~20 min/96-well plate, ~75 min/384-well plate
  • Applications: High-throughput
  • Plate Format: 96-well/384-well
  • Dynamic Range:5 logs

Includes: computer, touch screen monitor, manuals, and software.

Learn More
Luminex-Bio-Plex-3D-Microplate-Luminescence-Reader-11518
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perkin Elmer EnVision 2102-0010 Multilabel Microplate Reader

Perkin Elmer EnVision 2102-0010 Multilabel Microplate Reader

Cambridge ID #: 11154

Includes:

  • Bar Code reader
  • Computer loaded with Software

 

 

The 2103 EnVision Multilabel Plate Readers are fast, sensitive and versatile benchtop readers that deliver optimized performance in every application and for every label. Their unique design features modular label-specific optical mirror modules, high energy flash lamps, and high speed detectors.

Specifications:

  • Light Source: Xenon flash lamp
  • Plate Formats: 1 to 3456
  • Temperature Control:
    • Temperature range: from 2 °C above ambient up to 45 °C (0.5 °C increments)
    • Uniformity: ± 1 °C
    • Heating time: < 10 minutes (from RT up to 37 °C)
  • Shaking: linear, orbital, dual orbital
  • Dispenser:
    • Dispense volume: 2-475 μL (1 μL increments)
    • Pump speed: 100-500 μL/s
    • Dead volume: 750 μL. With pump-back function < 50 μL using stardard tubing length and factory settings.
Learn More
Perkin-Elmer-EnVision-2102-0010-Multilabel-Microplate-Reader-11154
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perkin Elmer EnVision 2104-0020 Multilabel Microplate Reader

Perkin Elmer EnVision 2104-0020 Multilabel Microplate Reader

Cambridge ID #: 17876

Includes:

  • Bar Code reader
  • Computer loaded with Software

 

 

The 2103 EnVision Multilabel Plate Readers are fast, sensitive and versatile benchtop readers that deliver optimized performance in every application and for every label. Their unique design features modular label-specific optical mirror modules, high energy flash lamps, and high speed detectors.

Specifications:

  • Light Source: Xenon flash lamp
  • Plate Formats: 1 to 3456
  • Temperature Control:
    • Temperature range: from 2 °C above ambient up to 45 °C (0.5 °C increments)
    • Uniformity: ± 1 °C
    • Heating time: < 10 minutes (from RT up to 37 °C)
  • Shaking: linear, orbital, dual orbital
  • Dispenser:
    • Dispense volume: 2-475 μL (1 μL increments)
    • Pump speed: 100-500 μL/s
    • Dead volume: 750 μL. With pump-back function < 50 μL using stardard tubing length and factory settings.
Learn More
Perkin-Elmer-EnVision-2104-0020-Multilabel-Microplate-Reader-17876
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Labsystems Multiskan Spectrum Microplate UV/VIS Reader

Thermo Labsystems Multiskan Spectrum Microplate UV/VIS Reader

Cambridge ID #: 17010

Multiskan Spectrum makes getting results easier, replacing separate spectrophotometers and microplate reading instruments by providing both functions in one convenient, compact instrument.  The Multiskan Spectrum is truly two instruments in one, combining both cuvette reading capabilities and advanced microplate reading in one convenient, compact instrument.  You can easily take quick absorbance measurements in a cuvette between the cycles of a microplate enzyme kinetics experiment. 

 

For maximum flexibility, Multiskan Spectrum accepts all microplate for mats from 6- to 384-wells, as well as cuvettes from standard to ultra micro capacities in glass, plastic, or quartz. You can take multiple photometric readings per well on large format plates, or single measure ments requiring just 30 μl in 384-well plates.

 

Scanning range of 200 – 1000 nm.  The built-in monochromator makes it simple to select any wavelength from 200 nm to 1000 nm in 1 nm steps without ever changing a filter. Sample absorbances can be scanned over the whole spectrum either in microplates or cuvettes.

 

Typical applications of the Multiskan Spectrum

  • UV/Visible spectrophotometry
  • Spectrum scan
  • Nucleic acid analysis
    • RNA concentration (A260)
    • ssDNA concentration (A260)
    • dsDNA concentration (A260)
    • DNA purity (A260/A280)
  • Enzyme kinetics
    • E.g.,Vmax and Km
  • Protein analysis
    • Biuret protein determination
    • Bradford protein determination
    • BCA protein determination

 

Technical Specifications

 

Performance

  • Wavelength range 200 – 1000 nm
  • Read-out range 0 – 4 Abs
  • Linearity 0 – 3 Abs, ±/- 2% at 450 nm
  • Accuracy ± 1% or ± 0.005 Abs (0 – 2 Abs)
  • ± 2.0% (2 – 3 Abs)
  • Precision CV < 1% (0 – 2 Abs)
  • CV < 2% (2 – 3 Abs)
  • Optical bandpass 2 nm
  • Wavelength accuracy ± 1 nm
  • Stray light < 0.02% at 230 nm

 

General Specifications

  • Microplate types 6-, 12-, 24-, 48-, 96- and 384-well plates
  • Wavelength selection Tunable monochromator, 200 – 1000 nm in increments of 1 nm
  • Light source 10 W Xenon flash lamp
  • Detectors Photodiodes
  • Incubator temperature range Ambient (+25°C) +4°C to 45°C
  • Mains input 100 – 240 V (50/60 Hz) autoranging
  • Power consumption 200 VA
  • Dimensions 397 mm (W) x 217 mm (H) x 450 mm (D)
  • [15.6” (W) x 8.5” (H) x 17.7” (D)]
  • Weight 12.5 kg (27.5 lbs.)
Learn More
Thermo-Labsystems-Multiskan-Spectrum-Microplate-UV-VIS-Reader-17010
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping