Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Sub Visible Particle Analyzer: 46-60 of 92

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
BD BioScience FACSCanto II 2 Laser Flow Cytometer

BD BioScience FACSCanto II 2 Laser Flow Cytometer

Cambridge ID #: 17183

The BD FACSCanto system breaks new frontiers in flow cytometry by providing an efficient, easy-to-use yet powerful six-color benchtop analyzer. It incorporates many technology advances first developed in the BD LSR II expandable analyzer and the BD FACSAria cell sorter. It supports a broad range of research applications, being particularly suited for rare event analysis with its high speed, great sensitivity, and minimal sample-to-sample carryover.

 

The BD FACSCanto system combines a patented optical design for enhanced signal retention on six fluorescent and two scatter parameters, digital electronics for processing up to 10,000 events per second, and a novel sample injection tube supporting carryover of less than 0.1%. Your total benefit consists of the best fluorescence sensitivity to resolve dim events, cleaner data due to minimal sample contamination, and rapid processing rates, preserving valuable time for science. BD FACSCanto performance overcomes obstacles in rare event analysis and in functional studies for low detection ranges.

 

Includes:

  • Computer w/ FacsDiva Software
  • Fluids Cart
  • 2 laser, Blue(488) and Red (633)
  • 3 PMTs in 4-2 configuration w/ side scatter
  • All Necessary Cables
  • Manuals

 

Optics

Lasers

  • Air-cooled
  • 488-nm solid state, 20-mW laser output
  • 633-nm HeNe, 17-mW laser output
  • Laser Configuration: Spatially separated beams with 9 x 65-μm elliptical spots
  • Optical Alignment Procedure: Fixed, no operator alignment required
  • Flow Cell: 180 x 430-μm rectangular quartz flow cell
  • Collection Optics: Optical-gel coupled 1.2 NA lens
  • FSC Resolution: 1.0 μm
  • SSC Resolution: 0.5 μm
  • Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT
  • FSC Detector: Photodiode with 488/10 BP
  • SSC Detector: PMT with 488/10 BP
  • Fluorescence Detectors: 6 PMTs in 4-2 configuration w/ side scatter
Learn More
BD-BioScience-FACSCanto-II-2-Laser-Flow-Cytometer-17183
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Beckman Coulter FC 500 Flow Cytometer

Beckman Coulter FC 500 Flow Cytometer

Cambridge ID #: 20487

Specifications:

 

 Lasers: 20-mw 488 Argon Ion 

  • Detectors: FS, SS, 5 FL PMT 
  • Flow Cell: 150x450 micron rectangular Channel 
  • Sample Loading: 96-well, 24-well, 40-tube 
  • Signal Processing: 20-bit Digital Signal Processing 
  • Software: MXP v 2.2 
  • Overall Analysis Range:5-40 micron particle size 
  • Sample Volume: 25-500 microliters 
  • Weight: 187 lbs 
  • Width: 5 inches 
Learn More
Beckman-Coulter-FC-500-Flow-Cytometer-20487
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fluid Imaging Technologies FlowCam ALH - Automated Liquid Handling System *NEW* Liquid Handler

Fluid Imaging Technologies FlowCam ALH - Automated Liquid Handling System *NEW* Liquid Handler

Cambridge ID #: 18763

Description:

  • Programmable pre-analysis sample preparation
  • Heating & cooling features
  • Self-contained system
  • Vertical set-up saves bench space
  • Standard SBS format labware
  • Disposable pipette tips
  • High accuracy fluid dispensing
  • Complete control of workflows
  • Particle identification via Microsoft Excel®

Specifications:

  • Operating principle: Single robotic XYZ arm, hydraulic fill on all fluidics
  • Labware format: SBS
  • Number of positions for labware: 7
  • Maximum number of wells per deck position: 96
  • Maximum volume dispensed per operation: 1000μl
  • Minimum volume dispensed during dilution or reagent operations: 5μl
  • Minimum volume dispensed into FlowCam for analysis: 100μl
  • CV of aspiration/dispensing accuracy: ±0.5%
  • Pipette format: Disposable
  • Environmental (particulate) control: Positive pressure HEPA filtration
  • Sterilization: UV, programmable exposure time
  • Mechanical orbital method: 100 -2000 RPM clockwise
  • Sample conditioning: Heating/cooling 2-90°C
  • Mixing: Aspiration/dispensing method
  • Multiple assays/workflows supported: Yes
  • Operation pause and resume: Yes
  • CFR21 Compliant: Yes
  • Workspace illumination: User controlled white LED
  • Dimensions (H x W x D): 49 x 30 x 25” (124.5 x 76.2 x 63.5 cm)
  • Weight: 190 lbs. (86.7 kg)
  • Voltage: 110-220 V
  • Power: 700 watts, including FlowCam
  • Operating Temperature Operating: 5-40°C
  • Storage Temperature: -20-60°C
Learn More
Fluid-Imaging-Technologies-FlowCam-ALH---Automated-Liquid-Handling-System-*NEW*-Liquid-Handler-18763
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Alpha Innotech Fluorchem 5500 Gel Imaging System

Alpha Innotech Fluorchem 5500 Gel Imaging System

Cambridge ID #: 16297

Using advanced electrically cooled SuperChemiNova CCD camera technology, the FluorChem provides real time display and the R.S.D.P. standard of resolution, sensitivity, dynamic range and performance. The FluorChem is ideal for chemiluminescence, fluorescence, and visible imaging applications.

 

Features:

  • Applications: chemiluminescence, fluorescence and colorimetric
  • Transillumination White: For protein gels,autorads,film, plates and flasks
  • Transillumination UV: For the fluorescent gels such as EtBr, SYPRO Red, etc
  • Software: easy-to-use software for darkroom control, image capture, enhancement and analysis
  • Camera: High-performance, high resolution, CCD camera allows imaging of low-light samples in UV-illuminated, and fluorescent applications. 12.5x75mm, F1.2 Motorized Zoom Lens for ChemiImager 5500 with DE 500/400 cabinet (Includes motorized lens, ChemiImager 5500 camera mount, and cables. Requires AlphaEaseFC software version with software controls of motorized lens) -
  • Lens: Zoom lens, close-up 2+ diopter lens and interference filter
  • Filters: chemiluminescence samples, ethidium bromide, SYPRO Orange (595 nm) each filter has a bandwith +/-40 nm
  • Allows to visualize chemiluminscent reactions

 

How is this unit better than Alpha Imager 3400:

 

For low-light applications, such as chemiluminescence, a longer exposure time may be appropriate and it is best to go to the red ACQUIRE IMAGE button to directly acquire the image once the desired exposure time is set. Alternatively, if a good exposure time is unknown, try selecting Auto-Expose and using the super sensitivity selection. Auto-Expose will generate an image showing the signal intensity usually in less than 3 minutes. Afterwards, a different sensitivity (binning) mode can be selected to generate a better resolution image and the software will automatically calculate the new exposure time for you.

 

Learn More
Alpha-Innotech-Fluorchem-5500-Gel-Imaging-System-16297
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Rainin HPXL Solvent Delivery SystemImage Coming Soon

Rainin HPXL Solvent Delivery System

Cambridge Scientific ID #'s: 11708, 11709

Description:

The Rainin HPXL Solvent Delivery System consists of two binary pump gradient liquid chromatographic systems. One of the systems uses biocompatible (titanium) pump heads, injection valve and mixer. Two detectors are available: a single (variable) wavelength high sensitivity UV/Visible detector and a dual wavelength UV/Vis detector. A 900 nanoliter flow cell is available for the dual wavelength detector for low flow applications.

Learn More
Rainin-HPXL-Solvent-Delivery-System-11708
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Andor Technology iKon-M PV Inspector Series Back Illuminated CCD, Deep Depletion with fringe *NEW* Microscope Camera

Andor Technology iKon-M PV Inspector Series Back Illuminated CCD, Deep Depletion with fringe *NEW* Microscope Camera

Cambridge ID #: 16355

Andor’s iKon-M 934 series cameras are designed to offer the ultimate in high-sensitivity, low noise performance, ideal for demanding imaging applications. These high resolution 1024 x 1024 CCD cameras boast up to 95% QEmax, high dynamic range, 13 μm pixels and exceptionally low readout noise. The iKon-M benefits from negligible dark current with industry-leading thermoelectric cooling down to -100°C. The ‘Deep Depletion’ sensor option offers ultimate performance for NIR applications, the new Dual AR coating extends the QE performance significantly across the UV/visible region of the spectrum for the broadest possible spectral coverage from one sensor. Fringe Suppression Technology radically minimizes etaloning effects in the NIR. Rapid vertical shifts combined with fast kinetics acquisition mode, comprehensive trigger modes and custom coated wedge window options, render the deep Depletion models ideal for NIR

optimized Bose Einstein Condensation applications.

 

Features and Benefits:

  • Extended range Dual-AR option: Superior UV-NIR broadband back-illuminated QE
  • TE cooling to -100°C: Critical for elimination of dark current
  • Fringe Suppression Technology: NIR etaloning greatly reduced (BR-DD and BEX2-DD sensor types)
  • Up to 5 MHz pixel readout: High frame rates achievable
  • Ultra low noise readout: Intelligent low-noise electronics offer the most ‘silent’ system noise performance available
  • UltraVac: Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year
  • 13 x 13 μm pixel size: Optimal balance of dynamic range and resolution
  • Integrated shutter: C-mount shutter as standard. Closed during readout to avoid vertical smear
  • Cropped Sensor Mode: Specialized acquisition mode for continuous imaging with fastest possible temporal resolution
  • Enhanced Baseline Clamp: Quantitative accuracy of dynamic measurements
  • USB 2.0 connection: Simple Plug & Play connection
  • Integrated in EPICS: Platform is fully integrated into the EPICS control software

 

Specifications:

  • Active pixels: 1024 x 1024
  • Sensor size: 13.3 x 13.3 mm
  • Pixel size (W x H): 13 μm x 13 μm
  • Active area pixel well depth: 100,000 e- (130,000 e- for BR-DD and BEX2-DD models)
  • Pixel readout rates (MHz): 5, 3, 1, 0.05
  • Read noise: 2.9 e-
  • Maximum cooling: -100°C
  • Frame rate: 4.4 fps (full frame)
  • System window type: UV-grade fused silica, ‘Broadband VUV-NIR’, wedged
  • Interface: USB 2.0
Learn More
Andor-Technology-iKon-M-PV-Inspector-Series-Back-Illuminated-CCD,-Deep-Depletion-with-fringe-*NEW*-Microscope-Camera-16355
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
New Brunswick Innova 4000 Benchtop Environmental Shaker

New Brunswick Innova 4000 Benchtop Environmental Shaker

Cambridge Scientific ID #'s: 6181, 7271

The New Brunswick INNOVA 4000 Series are benchtop gyratory incubator shakers. Offering rigid control of temperature and agitation, the large-capacity INNOVA 4000 shaker is capable of culturing a wide array of organisms in test tubes and flasks up to 2.8 L.

 

The INNOVA series offers a wide temperature range. The INNOVA Model 4000 provides uniform temperature control in a range up to 60°C, while the high-temperature INNOVA 4080 incubator shaker increases the range to 80°C for added hybridization, adding capabilities for various molecular biology techniques, including hybridization studies, plasmid preps, DNA fingerprinting and more. The optional factory-installed cooling coil is also available for operating at sub-ambient conditions.

 

The INNOVA 4000 was designed with safety and ease of use in mind. The system includes an automatic cut-out feature of the shaker when the lid is opened to protect the operator. A fail-safe thermostat also turns off heat if temperature high limit is exceeded to protect cultures, and the hydraulic arm eases lid opening and closing.

 

Equipped with a large capacity blower and tightly constructed chamber, the INNOVA 4000 series incubator shaker has a self-correcting microprocessor feedback control which instantly compensates for changes in temperature. Another superior feature of the INNOVA 4000 include the interchangeable, large-capacity accessory platforms, 18" x 18" (46 x 46 cm) that accept gel trays, culture tubes and flasks to 2.8 L.

 

Specifications:

  • Platform Size: 18 x 18
  • Maximum Capacity (250 ml Flasks on Universal Platform): 18
  • Capacity & Largest Flask Size on Universal Platform: 5 x 2L
  • Orbit Diameter (in) 75
  • Temperature Range (C°): Ambient +5 to 60 (4080 is Ambient +5 to 80)
  • Digital Display: Yes
  • Agitation: 25 to 500 rpm
  • Type/Application: Benchtop
  • Gassing Manifold: Optional
  • Overall dimensions: W x D x H (in) 21 x 27.5 x 19.75
  • Weight (lbs): 115
Learn More
New-Brunswick-Innova-4000-Benchtop-Environmental-Shaker-6181
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
New Brunswick Innova 4080 Benchtop Environmental ShakerImage Coming Soon

New Brunswick Innova 4080 Benchtop Environmental Shaker

Cambridge Scientific ID #'s: 20106, 14271

The New Brunswick INNOVA 4000 Series are benchtop gyratory incubator shakers. Offering rigid control of temperature and agitation, the large-capacity INNOVA 4000 shaker is capable of culturing a wide array of organisms in test tubes and flasks up to 2.8 L.

 

The INNOVA series offers a wide temperature range. The INNOVA Model 4000 provides uniform temperature control in a range up to 60°C, while the high-temperature INNOVA 4080 incubator shaker increases the range to 80°C for added hybridization, adding capabilities for various molecular biology techniques, including hybridization studies, plasmid preps, DNA fingerprinting and more. The optional factory-installed cooling coil is also available for operating at sub-ambient conditions.

 

The INNOVA 4000 was designed with safety and ease of use in mind. The system includes an automatic cut-out feature of the shaker when the lid is opened to protect the operator. A fail-safe thermostat also turns off heat if temperature high limit is exceeded to protect cultures, and the hydraulic arm eases lid opening and closing.

 

Equipped with a large capacity blower and tightly constructed chamber, the INNOVA 4000 series incubator shaker has a self-correcting microprocessor feedback control which instantly compensates for changes in temperature. Another superior feature of the INNOVA 4000 include the interchangeable, large-capacity accessory platforms, 18" x 18" (46 x 46 cm) that accept gel trays, culture tubes and flasks to 2.8 L.

 

Specifications:

  • Platform Size: 18 x 18
  • Maximum Capacity (250 ml Flasks on Universal Platform): 18
  • Capacity & Largest Flask Size on Universal Platform: 5 x 2L
  • Orbit Diameter (in)75
  • Temperature Range (C°): Ambient +5 to 60 (4080 is Ambient +5 to 80)
  • Digital Display: Yes
  • Agitation: 25 to 500 rpm
  • Type/Application: Benchtop
  • Gassing Manifold: Optional
  • Overall dimensions: W x D x H (in) 21 x 27.5 x 19.75
  • Weight (lbs): 115
Learn More
New-Brunswick-Innova-4080-Benchtop-Environmental-Shaker-20106
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Andor Technology iXon Life 888 EMCCD *NEW* Microscope Camera

Andor Technology iXon Life 888 EMCCD *NEW* Microscope Camera

Cambridge ID #: 16888

Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

Specifications:

  • Sensor Type: Back Illuminated, standard AR coated
  • Active pixels (H x V): 1024 x 1024
  • Pixel Size (H x V: µm): 13 x 13
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Active Area Pixel Well Depth (e-): 80,000 180,000
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 30 MHz•3 -55ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 30 MHz•3 -65ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•6: 730,000 e-
  • Read noise (e-) •7: <1
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp accuracy: 10 ns

 

 

 

 

 

Learn More
Andor-Technology-iXon-Life-888-EMCCD-*NEW*-Microscope-Camera-16888
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Life 897 EMCCD *NEW* Microscope Camera

Andor Technology iXon Life 897 EMCCD *NEW* Microscope Camera

Cambridge ID #: 16889

Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. The ideal detector to drive superlative performance from confocal spinning disk technology. Whilst affording superb confocality and low rates of phototoxicity, spinning disk experiments are inherently photon starved, by virtue of the photon rejection implicit to optical sectioning. The superior sensitivity of the iXon Life detector brings these low light images to life.

Specifications:

  • Sensor Type: Back Illuminated, standard AR coated
  • Active pixels (H x V): 512 x 512
  • Pixel Size (H x V: µm): 16 x 16 μm
  • Image Area: 8.2 x 8.2 mm with 100% Fill Factor
  • Active Area Pixel Well Depth (e-): 80,000 180,000
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -70ºC, 17 MHz•3 -70ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -80ºC, 17 MHz•3 -80ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 2.0
  • Lens Mount: C-mount
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00030
  • Spurious Background (events/pix) @ 1000x gain / -80°C: 0.0018
  • Active Area Pixel Well Depth: 180,000 e
  • Gain Register Pixel Well Depth•6: 800, 000 e
  • Read noise (e-) •7: <1
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.3 to 3.3 µs (user selectable)
  • Timestamp accuracy: 10 ns

 

 

 

 



 

 

 

 

 

Learn More
Andor-Technology-iXon-Life-897-EMCCD-*NEW*-Microscope-Camera-16889
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 BVF USB3 EMCCD *NEW* Microscope Camera

Andor Technology iXon Ultra 888 BVF USB3 EMCCD *NEW* Microscope Camera

Cambridge ID #: 16875

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, standard AR coated with fringe suppression
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate:
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-BVF-USB3-EMCCD-*NEW*-Microscope-Camera-16875
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 EX USB3 EMCCD *NEW* Microscope Camera

Andor Technology iXon Ultra 888 EX USB3 EMCCD *NEW* Microscope Camera

Cambridge ID #: 16874

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, EX2 dual AR coated
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-EX-USB3-EMCCD-*NEW*-Microscope-Camera-16874
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon Ultra 888 EXF USB3 EMCCD *NEW* Microscope Camera

Andor Technology iXon Ultra 888 EXF USB3 EMCCD *NEW* Microscope Camera

Cambridge ID #: 16881

The highly innovative, megapixel, camera offers single photon sensitivity across a large field of view, at 26 fps. Building on a rich history of first to market innovation, the ‘supercharged’ iXon Ultra 888, represents a massive performance boost for the largest available EMCCD sensor, as well as the first USB 3.0 enabled EMCCD camera. The iXon Ultra 888 has been fundamentally re-engineered to facilitate a 3x acceleration of the pixel readout speed to an unprecedented 30 MHz, whilst maintaining quantitative stability, propelling the full frame performance to video rate. Designed to be the most flexible yet easy to use EMCCD on the market, optimizable for a wide variety of application requirements in a single click via the OptAcquire™ feature. Crucially, the iXon brand carries an outstanding reputation within the industry for quality and reliability, brandishing an unparalleled track record of minimal field failures.

Specifications:

 

  • Sensor QE: Back-illuminated, EX2 dual AR coated with fringe suppression
  • Active Pixels: 1024 x 1024
  • Pixel Size: 13 x 13 μm
  • Image Area: 13.3 x 13.3 mm with 100% Fill Factor
  • Pixel Readout Rate:
  • Minimum Temperature, air cooled, ambient 20°C: 10 MHz -80ºC, 30 MHz•3 -60ºC
  • Chiller Liquid Cooling, coolant @ 10°C, >0.75l/min: 10 MHz -95ºC, 30 MHz•3 -75ºC
  • Thermostatic Precision: ± 0.01°C
  • Triggering: Internal, External, External Start, External Exposure, Software Trigger
  • System Window Type:
  • #BV and BVF: UV-grade fused silica, Broadband Visible-Near Infrared, 0.5 degree wedge
  • UVB, #EX, EXF: UV-grade fused silica, Broadband Vacuum Ultraviolet-Near Infrared, 0.5 degree wedge
  • Digitization: 16-bit (at all speeds)
  • PC Interface: USB 3.0•12
  • Lens Mount: C-mount
  • Direct Data: Access Camera Link 3-tap output
  • Dark Current and Background Events•4,5:
  • Dark Current (e- /pixel/sec) @ -80°C: 0.00025
  • Dark Current (e- /pixel/sec) @ max cooling: 0.00011
  • Spurious Background (events/pix) @ 1000x gain / -85°C: 0.005
  • Active Area Pixel Well Depth: 80,000 e-
  • Gain Register Pixel Well Depth•76: 730,000 e-
  • Linearity•8: Better than 99.9%
  • Vertical Clock Speed: 0.6 to 4.33 µs (user selectable)
  • Timestamp Accuracy: 10 ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Learn More
Andor-Technology-iXon-Ultra-888-EXF-USB3-EMCCD-*NEW*-Microscope-Camera-16881
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Andor Technology iXon3 860 BV EMCCD *NEW* Microscope Camera

Andor Technology iXon3 860 BV EMCCD *NEW* Microscope Camera

Cambridge ID #: 16168

Andor’s iXon3 860 back-illuminated EMCCD is designed for very rapid imaging of low light events. The iXon3 860 benefits from an advanced set of user–requested features, including OptAcquire, Count Convert, Spurious Noise Filters & Signal Averaging. RealGain provides quantitative EM gain calibration. Sub-millisecond biology is readily accessible through use of sub-array selection, pixel binning and Cropped Sensor Mode pushes frame rates to new extremes. The speed and sensitivity of the iXon3 860 also renders it ideal for adaptive optics.

Specifications:

  • Active Pixels: 128 x 128
  • Pixel Size: 24 x 24 um
  • Active Area Pixel Well Depth: 160,000 e-
  • Gain Register Pixel Well Depth: 800,000 e-
  • Maximum Readout Rate: 10 MHz
  • Frame Rate: 513 – 14,025 fps
  • Read Noise: < 1e- with EM gain
  • Maximum Cooling: -100°C
Learn More
Andor-Technology-iXon3-860-BV-EMCCD-*NEW*-Microscope-Camera-16168
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Shimadzu LC-2030C Plus

Shimadzu LC-2030C Plus

Cambridge ID #: 22719

Shimadzu's Cannabis and Hemp Testing Solutions cover a broad range of applications, from accurate potency testing and terpene profiling to contaminate testing for pesticides, residual solvents, heavy metals, and mycotoxins/aflatoxins. We supply the instruments, methods and experience necessary to get you up and running quickly. Shimadzu scientific instruments have been applied to natural products, food sciences, pharmaceuticals and environmental testing for decades. Whether you are a chromatography expert or a novice, our platforms and training ensure that your laboratory will generate quality results from a wide variety of cannabis samples. Our easy to use platforms save you time and money, maximizing the profits of your laboratory. Shimadzu can help you with your QA/QC testing, peak harvesting analysis and cannabis research.


System Includes:
Shimadzu Hemp Analyzer - Prominence 2030-C HPLC with Computer, Computer Interface, Column, Hemp Analyzer Solution.

Learn More
Shimadzu-LC-2030C-Plus--22719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping