Used Lab Equipment

Used Lab Equipment

We typically have used and reconditioned pumps in stock from leading manufacturers like Cole-Palmer and Watson/Marlow.

Thermal Rocker: 76-90 of 122

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Labconco 6910100 PCR EnclosureImage Coming Soon

Labconco 6910100 PCR Enclosure

Cambridge ID #: 19576

Features:

  • Glacier white, dry powder epoxy-coated aluminum construction.
  • 3/16 in thick tempered safety glass sides.
  • Air-mixing, epoxy-coated steel rear baffle.
  • Two roughing pre-filters.
  • Two 1.5 in diameter utility ports with plastic plugs.
  • Gas-assisted filter clamping mechanism.
  • Control panel with LCD for display of filter time elapsed; programmable timer for audio/visual alarm; ALARM/MUTE switch with LED indicator; SET FILTER TIME, UP/DOWN, and ENTER programming switches; and event timer.
  • Built-in, non-sparking motor/blower.
  • Pre-wired with two 20-watt fluorescent lights and switches for blower and light.
  • Angled ¼ in thick tempered safety glass sash, adjustable to two operating height positions (13 in and 15 in to work surface), pivots to full open position (24.25 in) for cleaning and transfer of material.
  • Face velocity of 100 fpm (236 CFM) when sash opening to work surface is 13 in and 80 fpm (236 CFM) when sash opening is 15 in.
  • Air sampling syringe for test port.
  • Shipped fully assembled.

 

Specifications:

 

  • Power Requirements: 115 V, 60 Hz, 3 A
  • Weight: 290 lbs

 

 

Learn More
Labconco-6910100-PCR-Enclosure-19576
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Applied Biosystems 7900HT Fast Real-Time PCR System Real-Time PCR

Applied Biosystems 7900HT Fast Real-Time PCR System Real-Time PCR

Cambridge ID #: 22442

The 7900HT Fast Real-Time PCR System is a real-time quantitative PCR system that combines 96- and 384-well plate compatibility and the TaqMan® Low Density Array with fully automated robotic loading-and now also offers optional Fast real-time PCR capability.

  • Fast PCR option reduces run time to about 35 minutes in a standard 96-well format, or about 55 minutes in a 384-well plate
  • Continuous wavelength detection from 500-660 nm allows the use of multiple fluorophores in a single reaction
  • Measure gene expression levels, detect and quantitate pathogens, perform allelic discrimination (SNP genotyping) assays as well as score the presence of gene sequences
  • 96- or 384-well plate compatibility (including the TaqMan® Low Density Array)
  • Optional Enterprise edition software provides data analysis tools that support 21 CFR Part 11 guidelines providing data integrity and security
  • Hands-free plate-loading and unloading provides true walkaway automation allowing you to increase your lab's productivity
  • Proven assay development guidelines save time and money

Specifications:

  • Calibrated Dye: SYBR® Green I, ROX™, NED™, JOE™, TAMRA™, VIC™, FAM™, TET™
  • Capacity: Up to 84 x 384-well plates with optional automation accessory
  • Detection Method: SYBR, Primer-Probe Detection
  • Dimensions: 72 cm (W) x 84 cm (D) x 64 cm (H) (with drawer open)
  • High-throughput Compatibility: High-throughput Compatible, Multiplexing
  • Optics: Extended-life 488 nm argon-ion laser excitation source, No filters (CCD acts as spectrograph with continuous detection 500 -650 nm)
  • Passive Reference Dye: ROX (Separate Tube), No ROX, Other Passive Reference Dye, ROX (Pre-mixed)
  • Reaction Speed: Fast 
  • Reaction Volume Range: 5-20 µl
  • Run Time: 52 minutes (384-well in fast mode), <2 hrs (384-well in standard mode)
  • Sample Ramp Rate: Fast mode: ± 3.0°C⁄sec, Standard mode: ± 1.6°C⁄sec
  • Temperature Accuracy: ±0.25°C of display temperature
  • Temperature Range (Metric): 4-100°C
  • Temperature Uniformity: ±0.5°C
  • Thermal Cycling System: Peltier-Based System
  • Throughput: >5,000 real-time PCR rxns per day (384-well block and automation accessory), >10,000 endpoint PCR rxns per hour (384-well block and automation accessory)
  • Weight: 114 kg (250 lbs) with automation accessory, 82 kg (180 lbs) without automation accessory
  • Block Format: Interchangeable
  • Dynamic Range: Up to 9 logs of linear dynamic range
  • Sensitivity: Down to 10 copies
Learn More
Applied-Biosystems-7900HT-Fast-Real-Time-PCR-System-Real-Time-PCR-22442
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MVE Cryogenics 810 Eterne F Cryo Storage Tank

MVE Cryogenics 810 Eterne F Cryo Storage Tank

Cambridge ID #: 20960

Features:

• The offset neck and guaranteed free moving sample turn tray offer incredible user convenience and sample access. The
single sample retrieval point is incredibly ergonomic compared to the reaching and stretching required with standard freezers.
• Specifically designed for vapor storage.
• Efficient thermal design ensures 95% of system surface area enclosed by vacuum - compare to typical 60% in standard freezers.
• Lowest sample temperature in the industry with minus 190°C. This ensures an increased safety margin below the Glass Transition Temperature and
better long term sample viability in true vapor storage.
• Lowest liquid usage - typically 40% below equivalent standard tanks of similar capacity. Note that NER’s for competitive tanks are calculated before
the addition of the vapor sleeve, which will increase consumption of LN2 by 50% or more.

Specifications:

  • LN2 Capacity (Liters): 370
  • LN2 Capacity Under Platform (L): 52
  • Neck Opening (Inches): 12.5
  • Useable Internal Height (Inches): 28.8
  • Inner Diameter (Inches): 28.5
  • Overall Height (Inches): 47.3
  • Outer Diameter (Inches): 32
  • Weight Empty (Lbs.): 475
Learn More
MVE-Cryogenics-810-Eterne-F-Cryo-Storage-Tank-20960
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Motic AE31 Elite *NEW* Inverted Phase Contrast Fluorescent Microscope

Motic AE31 Elite *NEW* Inverted Phase Contrast Fluorescent Microscope

Cambridge ID #: 17465

Live Cell Microscope Platform

  • Trinocular head Siedentopf type, 45o inclined (Light split 100:0/20:80)
  • Widefield high eyepoint eyepieces WFPL10X/22mm with diopter adjustment on both eyepieces and rubber eyecups
  • Side facing quintuple nosepiece CCIS Plan achromatic objective PL 4X
  • Coaxial coarse and fine focusing adjustment
  • Hard coated stage with metal and glass stage inserts
  • ELWD condenser N.A. 0.30 (WD 72mm)
  • Phase slider Ph1 and brightfield
  • Phase centering telescope
  • Koehler illumination quartz halogen 6V/30W with external lamp house and intensity control
  • Objectives
    • CCIS Plan achromatic Phase objective PL Ph 10X, LWD
    • CCIS Plan achromatic Phase objective PL Ph 20X
    • Plan Achromat Phase LWD PL Ph1 40X, N.A. 0.5 / W.D. 3.0
  • Filter Cubes
    • DAPI/Hoechst/AlexaFluor 350
    • EGFP/FITC/Cy2/AlexaFluor 488  
    • TRITC/Cy3/TagRFP/AlexaFluor 546
  • 100w Mercury Fluorescent light w/ power supply OR X-Cite 120LEDMini
  • 54mm Petri dish holder
  • 0.5X C-mount camera adapter for 1/2” chip sensors

 

Includes: X-Cite 120LED Head, miniCube, speedDIAL, microscope flange, accessory kit

 

Features

  • LED Technology
  • White Light Excitation
  • Direct Coupled
  • Multiple Control Options
  • Small Footprint
  • Optimized Thermal Management
  • X-Cite Coupling Optics

 

Benefits

  • Efficiency, stability, instant ON/OFF and long lifetime
  • Excitation of commonly used fluorophores such as DAPI, CFP, GFP/FITC, YFP, mCherry/Texas Red, and Cy5
  • High Power excitation
  • Simple operation through USB, TTL or speedDIAL
  • Minimal space requirement ; less bench top real estate used
  • Maximum LED output, lifetime, stability and reliability
  • Efficient optical output and uniformity with highest performing coupling optics

 

Specifications:

  • Wavelength Range: 370-700nm
  • External Power Supply: Universal input 100-240VAC, 50/60Hz
  • Power Consumption: 150W
  • LED ON/OFF Response Times: 85μs TTL / 1ms USB
  • Control Options: ON/OFF - TTL compatible, speedDIAL, RS-232 commands (SDK available), USB
  • I/O Connections: BNC input , USB (B-type)
  • Dimensions – HEAD: 100mm x 135mm x 110mm (W x H x D)
  • Dimensions – CONTROLLER: 180mm x 110mm x 230mm (W x H x D)
  • Dimensions – speedDIAL: 80mm x 59mm x 112mm (W x H x D)
  • Weight: 3.4 kg (7.5 lb)
  • Certifications: RoHS, CE
  • Warranty: LEDs – 20,000 hours, All other X-Cite 120LEDmini components - 1 year, parts and labor
Learn More
Motic-AE31-Elite-*NEW*-Inverted-Phase-Contrast-Fluorescent-Microscope-17465
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MJ Research ALD-1234 Alpha BlocksImage Coming Soon

MJ Research ALD-1234 Alpha Blocks

Cambridge Scientific ID #'s: 8483, 7829

Description:

The MJ Research Alpha Slide ALD-0211 Thermal Cycler is engineered to adapt to the diverse needs of modern laboratories. This thermal cycler is designed as a swappable sample-block/heat-pump assembly, capable of customizing any DNA Engine line thermal cycler. The ALD-0211 is equipped with a thermal cycler base which efficiently distributes electric power, as well as thermoelectric heat pumps and sensors which help control sample temperatures. The ALD-0211 Thermal Cycler meets NIST-traceable standards with its ability to provide outstanding temperature uniformity using multi-sensor, multi zone temperature controls. Designed for humidified chamber hybridizations and in situ procedures, the Alpha Slide ALD-0211 system thermally cycles glass microscope slides in a dual-block format, with each block accommodating up to 16 slides.

Learn More
MJ-Research-ALD-1234-Alpha-Blocks-8483
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad ALD-1244 Alpha Blocks

Bio-Rad ALD-1244 Alpha Blocks

Cambridge ID #: 11761

Features:

  • Configuration: 48/48-well
  • Dual-block Alpha unit
  • Capacity: 2 x 48 x 0.2 ml tubes
  • Sample Volume: 5–125 µl

 

Learn More
Bio-Rad-ALD-1244-Alpha-Blocks-11761
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MJ Research ALD-1244 Alpha Blocks

MJ Research ALD-1244 Alpha Blocks

Cambridge Scientific ID #'s: 5176, 10298

Features:

  • Configuration: 48/48-well
  • Dual-block Alpha unit
  • Capacity: 2 x 48 x 0.2 ml tubes
  • Sample Volume: 5–125 µl

 

Learn More
MJ-Research-ALD-1244-Alpha-Blocks-5176
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
MJ Research Alpha Block Alpha BlocksImage Coming Soon

MJ Research Alpha Block Alpha Blocks

Cambridge ID #: 8721

Description:

The MJ Research 96-well alpha block is a single block alpha unit that can hold samples from 5–125 µl on one 96-well plate of 0.2 mL tubes. This block is for use with MJ Research thermal cyclers, including the PTC-100, PTC-200, PTC-225, and PTC-240. This MJ Research alpha block features the Hot Bonnet to allow oil-free operation.

Learn More
MJ-Research-Alpha-Block-Alpha-Blocks-8721
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MJ Research ALS-1238 Alpha BlocksImage Coming Soon

MJ Research ALS-1238 Alpha Blocks

Cambridge ID #: 7794

Features:

  • Configuration: 384-well
  • Single-block Alpha unit
  • Capacity: One 384-well plate
  • Sample Volume: 3–30 µl

 

Learn More
MJ-Research-ALS-1238-Alpha-Blocks-7794
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad ALS1296 Alpha Blocks

Bio-Rad ALS1296 Alpha Blocks

Cambridge Scientific ID #'s: 9430, 8609, 16088, 9431, 19290, 19288, 19289, 9396, 19291

Alpha units are interchangeable reaction modules available in a variety of formats to accommodate standard tubes and plates and high-density microplates.

Every thermal cycler in the DNA Engine family (the DNA Engine, DNA Engine Dyad, Dyad Disciple, and DNA Engine Tetrad 2 cyclers) accepts all interchangeable Alpha units. Changing an Alpha unit takes less than 10 seconds, with no tools required. The temperature accuracy specifications of Alpha blocks ensure consistent results experiment-to-experiment and cycler-to-cycler.

 

Features:

  • Single-block Alpha unit
  • Adjustable heated lids set manually; 96-well unit is gradient capable
  • Configuration: 96-well
  • Capacity: 96 x 0.2 ml tubes, one 96-well plate
  • Sample Volume: 5–125 µl
  • Catalog: ALS-1296
Learn More
Bio-Rad-ALS1296-Alpha-Blocks-9430
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Wave Biotech BASE 2050EH Bioreactor

Wave Biotech BASE 2050EH Bioreactor

Cambridge ID #: 17883

Features:

  • Disposable Presterile Bioreactor Chamber
  • Fit Cellbags: 2x2L, 2x10L, 1x20L with KIT20 or 2x22L, 1X50L with KIT50
  • Completely closed system
  • Operate inside an incubator or on the benchtop

 

Includes:

  • Electric Rocker Base for 20/50EHT
  • Digital temperature control

 

Applications:

 

Monoclonal antibodies

The WAVE Bioreactor system has been used extensively for monoclonal antibody production. Culture can be started at low volume and then fresh media added whenever the cell count is sufficiently high. This enables inoculum scale up without transfers. Batches ranging from 100ml to 500L have been run with cell densities over 10x106 cells/ml and productivity and product quality comparable to stirred tank bioreactors. Dissolved oxygen concentrations are not limiting and remain above 50% saturation.

 

Anchorage-dependent cells

Agitation in the WAVE Bioreactor system is powerful enough to mix and aeratethe culture. Yet it is gentle enough to cultivate anchorage-dependent cells on various microcarriers. The wave motion prevents setting and provides oxygenation without bubbles.

 

Virus production

The WAVE Bioreactor system provides a closed system that is ideal for virus production. In a gene therapy application, human 293 cells have been grown in suspension and then infected with recombinant adenovirus. Cells grew to 4x106 cells/ml and virus production was 1x105 virus particles/cell. The WAVE Bioreactor system produces viruses under complete containment without the need for biosafety cabinet.

 

Insect cell / Baculovirus

The high oxygen supply capability of the WAVE Bioreactor system makes it ideal for insect cell culture.Cell densities over 9x106 are routinely achieved. Baculovirus yields are higher than with conventional bioreactors. The WAVE Bioreactor system is extremely easy to operate and inoculum scale-up and infection can be done inside the bioreactor, reducing the need for transfers.

Learn More
Wave-Biotech-BASE-2050EH-Bioreactor-17883
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
MJ Research Dual 30 well Alpha BlocksImage Coming Soon

MJ Research Dual 30 well Alpha Blocks

Cambridge Scientific ID #'s: 14238, 13437

Specifications:

 

  • Capacity: 2 sets of 30 x 0.5 mL tubes
  • Temperature Range: 0 - 105°C
  • Temperature Accuracy: +/- 0.3°C
  • Temperature Uniformity: +/- 0.4°C
  • Ramping Speed: up to 3°C/sec
  • Dimensions: 12 x 12 x 12 in
  • Weight: 25 lbs
  • Power Requirements: 100 - 240V, 50/60Hz, 850W

 

  • Lowest Programmable Temperature: 30°C
Learn More
MJ-Research-Dual-30-well-Alpha-Blocks-14238
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Edwards E1M18 *NEW* Vacuum Pump

Edwards E1M18 *NEW* Vacuum Pump

Cambridge ID #: 17437

Features:

The EM range of oil-sealed rotary pumps is renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and the ability to withstand vapour. They are commonly used for laboratory and light industrial applications. It is a freestanding instrument with the drive provided through a flexible coupling by either a single phase or three phase motor.

 

Specifications:

 

  • Displacement:

                     50Hz: 20.5 m3h-1 /12.1 ft3min-1

                     60Hz: 25.0 m3h-1 /14.7 ft3min-1

 

  • Speed (Pneurop 6602):

 

                     50 Hz: 17.0 m3h-1 /10 ft3min-1
                     60Hz: 20.4 m3h-1 /12.1 ft3min-1

 

  • Ultimate vacuum (total pressure):
               without gas purge: 1 x 10-3 mbar /7.4 x 10-4 Torr
               with gas purge: 1.5 x 10-1 mbar /1.1 x 10-2 Torr
               with Fomblin: 1 x 10-2 mbar /7.5 x 10-3 Torr
  • Inlet connection: NW25
  • Outlet connection: Nozzle 15mm external Ø removable from 3/4 in BSP tapped hole
  • Max permitted pressure at outlet: 0.5 bar gauge /7 psig
  • Max inlet pressure for water vapour: 20 mbar / 15 Torr
  • Max water vapour pumping rate: 0.3 kg h-1
  • Operating temp range: 13-40°C
  • Nominal Rotation speed 50/60Hz: 1440 /1720 rpm
  • Power connector 1-ph: IEC EN 60320 C19
  • Motor power 50Hz: 0.55 kW
  • Motor power 60Hz: 0.75 kW
  • Noise at 50Hz: 57 dB(A)
  • Oil capacity max: 1.05 litre
  • Oil capacity min: 0.75 litre
  • Recommended oil: Ultragrade 19
  • Thermal overload device: prevents overheating (single phase only).
  • The drive is provided through a flexible coupling: by a single‑phase or three‑phase (four pole) motor.
  • The motors: are totally enclosed and are cooled by the motor cooling fan.
  • Full height O ring sealed oil sight glass: for easy checking of oil level and condition.

 

 

Learn More
Edwards-E1M18-*NEW*-Vacuum-Pump-17437
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards E2M18 *NEW* Vacuum Pump

Edwards E2M18 *NEW* Vacuum Pump

Cambridge ID #: 17438

Features:

The EM range of oil-sealed rotary pumps is renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and the ability to withstand vapour. They are commonly used for laboratory and light industrial applications. It is a freestanding instrument with the drive provided through a flexible coupling by either a single phase or three phase motor.

 

Specifications:

  • Displacement:

 

                  50Hz: 20.5 m3h-1 /12.1 ft3min-1
                  60Hz: 25.0 m3h-1 /14.7 ft3min-1

 

  • Speed (Pneurop 6602):

 

                   50 Hz: 17.0 m3h-1 /10 ft3min-1
                   60Hz: 20.4 m3h-1 /12.1 ft3min-1

  • Ultimate vacuum (total pressure): 

                   without gas purge: 1 x 10-3 mbar /7.4 x 10-4 Torr
                   with gas purge: 1.5 x 10-1 mbar /1.1 x 10-2 Torr
                   with Fomblin: 1 x 10-2 mbar /7.5 x 10-3 Torr

  • Inlet connection: NW25
  • Outlet connection: Nozzle 15mm external Ø removable from 3/4 in BSP tapped hole
  • Max permitted pressure at outlet: 0.5 bar gauge /7 psig
  • Max inlet pressure for water vapour: 20 mbar / 15 Torr
  • Max water vapour pumping rate: 0.3 kg h-1
  • Operating temp range: 13-40°C
  • Nominal Rotation speed 50/60Hz: 1440 /1720 rpm
  • Power connector 1-ph: IEC EN 60320 C19
  • Motor power 50Hz: 0.55 kW
  • Motor power 60Hz: 0.75 kW
  • Noise at 50Hz: 57 dB(A)
  • Oil capacity max: 1.05 litre
  • Oil capacity min: 0.75 litre
  • Recommended oil: Ultragrade 19
  • Thermal overload device: prevents overheating (single phase only).
  • The drive is provided through a flexible coupling: by a single‑phase or three‑phase (four pole) motor.
  • The motors: are totally enclosed and are cooled by the motor cooling fan.
  • Full height O ring sealed oil sight glass: for easy checking of oil level and condition

 

 

Learn More
Edwards-E2M18-*NEW*-Vacuum-Pump-17438
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards E2M28 *NEW* Vacuum Pump

Edwards E2M28 *NEW* Vacuum Pump

Cambridge ID #: 17439

Features:

The EM range of oil-sealed rotary pumps is renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and the ability to withstand vapour. They are commonly used for laboratory and light industrial applications. It is a freestanding instrument with the drive provided through a flexible coupling by either a single phase or three phase motor.

 

Specifications:

 

  • Power Connector 1-ph: IEC EN 60320 C19
  • Noise: 57 dB(A) at 50 Hz
  • Oil capacity max: 1.5 litres
  • Oil capacity min: 1.2 litres
  • Displacement (swept volume):
               50Hz: 32.2 m3h-1 / 19 ft3min-1
               60Hz: 38.9 m3h-1 / 22.3 ft3min-1
  • Speed (Pneurop 6602):
               50Hz: 27.5 m3h-1 / 16.2 ft3min-1
               60Hz: 33.0 m3h-1 / 19.5 ft3min-1
  • Ultimate vacuum (total pressure)
               without gas ballast: 1 x 10-3 mbar / 7.5 x 10-4 Torr
               with gas ballast: 1.5 x 10-2 mbar / 1.1 x 10-2 Torr
               with Fomblin: 1 x 10-2 mbar / 7.5 x 10-3 Torr
  • Inlet connection: NW25 flange
  • Outlet connection: Nozzle 15mm external Ø removable from 3/4 in BSP tapped hole
  • Max allowed pressure at outlet: 0.5 bar gauge / 7 psig
  • Max inlet pressure for water vapour: 30 mbar / 23 Torr
  • Max water vapour pumping rate: 0.7 kg h-1
  • Operating temperature range: 13 – 40 °C
  • Nominal rotation speed: 1440 / 1720 rpm
  • Motor power 50Hz: 0.75 kW
  • Motor power 60 Hz: 0.90 kW
  • Recommended oil: Ultragrade 19
  • Thermal overload device: prevents overheating (single phase only).
  • The drive is provided through a flexible coupling: by a single‑phase or three‑phase (four pole) motor.
  • The motors: are totally enclosed and are cooled by the motor cooling fan.
  • Full height O ring sealed oil sight glass: for easy checking of oil level and condition.
  • IE3 energy efficient 3 phase motor used with E2M28.

 

 

Learn More
Edwards-E2M28-*NEW*-Vacuum-Pump-17439