We offer an assortment of used and refurbished Waterbaths, Circulators and Chillers ranging from Hea...
Features:
Improve your assay results by dry incubation and mixing of your samples simultaneously: The Eppendorf ThermoMixer C is for heating, cooling, and mixing almost any of your lab vessels.
Specifications:
• Dimensions (W x D x H): 20.6 x 30.4 x 13.6 cm
• Temperature range: Min: 15 °C below RT, max: 100 °C
• Temperature accuracy: Max. ±0.5 °C at 20 – 45 °C
• Temperature settings: 1 °C / 100 °C
• Max. speed: 3,000 rpm
• Mixing and vortexing radius: 1.5 mm
• Mixing frequency: 300 - 3,000 rpm
• Mixing orbit: 3 mm
• Timer: 15 s – 99.3 h, continuous
• Power supply: 100 - 130 V, 50 - 60 Hz
Features:
These products are the perfect choice for mixing and heating established routine applications. The Eppendorf ThermoMixer F0.5/F1.5/F2.0 and FP have a fixed block for 0.5/1.5/2.0 mL tubes and plates, respectively.
Specifications:
• Dimensions (W x D x H): 20.6 x 30.4 x 17.0 cm
• Max. speed: 1,500 rpm
• Temperature range: min: 4 °C above RT, max: 100 °C
• Max. temperature control range: 100 °C
• Min. temperature control range: 24 °C
• Mixing and vortexing radius: 1.5 mm
• Mixing frequency: 300 x 1,500 rpm
• Mixing orbit: 3 mm
• Temperature accuracy: Max. ±0.5 °C at 20 – 45 °C
• Temperature settings: 1 °C / 100 °C
• Heating rate: Max. 11 °C/min
• Power supply: 100 - 130 V, 50 - 60 Hz
• Max. power consumption: 200 W
Features:
Easy to read display panels and intuitive controls with your choice of EASYset soft-touch keypad or QUIKset rotary switch control. The low height of the Legend RT at just 12.4 inches makes rotor loading and unloading easier than ever.
The SMARTspin Imbalance Detection System provides optimum run stability for all rotors at all speeds and allows for eye balancing of sample tubes
Wide Range of rotors for every application
Additional Specifications for the Legend
Features:
Thermo Scientific Value laboratory freezers are particularly suited for routine laboratory applications with sizes ranging from small benchtop to full-height freestanding. Our features are not available in domestic models and meet the demanding requirements of the laboratory environment.
An economical solution for safe sample storage
Factory tested prior to shipment
NRTL listed
Environmentally-friendly, non CFC refrigerants
Adjustable temperature control
Easy-to-clean, durable finish
Alert: These units are not intended for critical lab samples. Storage of high value, life science materials or clinical biologicals may require alarm, monitoring, back-up and temperature performance features. The need to add these features should be determined by your industrial hygenist or safety officer. These units are not suitable for corrosive environments.
Specifications:
Description:
Cast-aluminum top plate offers fast, uniform heating. Reaches max. temp. of 370 °C in 25 min. Demand-type thermostat maintains surface temp. within ±3 °C and compensates for voltage and ambient temp. fluctuations. Solid-state speed control on 120V unit has excellent slow-speed control, high starting torques, and constant stirring action. Stirring speed range: 100 to 1,000 rpm. Supplied with 3-wire cord and plug. Size: 9.6 L × 9 W × 5 in. H; 7 × 7 in. plate. UL and CSA listed.
Specifications:
Can be sold as an individual component or as part of a complete stack
Specifications:
Can be sold as an individual component or as part of a complete stack
Specifications:
Can be sold as an individual component or as part of a complete stack
Description:
Forma Class II, Type B2 Benchtop Models provide maximum personnel and product protection by maintaining ultra-clean laminar airflow and total exhaust of the entire work zone air. Total exhaust makes units ideal for work that generates non-explosive chemical vapors and gases. Type B2 units may be used for work with biosafety levels 1, 2, and 3 biological agents, carcinogens, anti-neoplastic drugs, and low level radioisotopes
Specifications:
The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.
Specifications:
Features:
Features:
The Agilent 1290 Infinity Thermostat is designed for use with other modules of the Agilent 1200 Infinity Series or with other LC systems if adequate remote control inputs and outputs are available. The thermostat is controlled from the Agilent 1200 Infinity Series Instant Pilot or from your Agilent control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials
Specifications:
Specifications:
Features:
General purpose incubator
Specifications:
Features:
Water Bath and Circulators