Transfer Station: 1-15 of 80

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Labconco 3820000 Transfer Station

Labconco 3820000 Transfer Station

Cambridge ID #: 19819

PuriCare Open Access Station (transfer station)

Features

  • Generous work surface area to accommodate standard rodent cages
  • Electric hydraulic lift for infinite height adjustment from 36.5" to 47" with the push of a button
  • Recessed and angled sashes for closer viewing without glare
  • Large 14" high sash openings to accommodate various cage sizes with brakes
  • Large 5" diameter, non-marking polyurethane casters
  • Two 99.99% efficient HEPA filters to trap allergens
  • Nominal downflow velocity of 55 fpm.
  • Economical, disposable upper and lower prefilters
  • Variable speed motor/blower and impellers
  • Particulate-free ISO Class 5 (formerly Class 100) air
  • Retractable, safety orange, top right-side mounted power cord, 28' (9 m) on 115 volt model
  • Two push/pull bars on the right hand side to facilitate transport
  • Two 32-watt fluorescent lights
  • Two easy-to-read, ADA-compliant Minihelic pressure gauges
  • ADA-compliant light and blower switches
  • ADA-compliant electrical duplex
  • Single pass airflow design with no recirculation through the enclosure helps prevent heat stress and odor build up.
  • Type 304 stainless steel dished work surface
  • Exterior is durable glacier white and slate gray epoxy-coated steel
  • Full three year warranty on parts and labor
  • ETL listed (115 volt models)
  • CE Conformity Mark (230 volt models)
Learn More
Labconco-3820000-Transfer-Station-19819
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Nuaire Nu-620-300 Animal Transfer StationImage Coming Soon

Nuaire Nu-620-300 Animal Transfer Station

Cambridge ID #: 26441
This item is new to the Cambridge Scientific Used Lab Equipment Inventory. As a result, a product description is currently unavailable. For further information about this product, please inquire and a representative will contact you shortly.
Learn More
Nuaire-Nu-620-300-Animal-Transfer-Station-26441
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Flow Sciences FS 10550 M Transfer Station

Flow Sciences FS 10550 M Transfer Station

Cambridge ID #: 6252

Description:

In the 10050 Series of Bulk Powder Chemical Transfer Stations, the HEPA filtration system is housed on top of the acrylic enclosure. This filtering configuration provides maximum containment while minimizing space and energy demands. The turbulence free airflow provides a stable working environment that prevents balance fluctuations. The base of the unit is roomy enough for larger balances and comes with a standard 20” (50.8 cm) diameter cutout in the base to accommodate a large drum. Multiple filtering options are available including HEPA with 99.99% efficiency. Each system comes equipped with a face velocity alarm to continuously monitor airflow.

Specifications:

  • Dimensions (W x D x H): 59.75” x 30” x 30” (151.8 x 76.2 x 76.2 cm)
  • Weight: 305 lbs. (138.4 kg)
Learn More
Flow-Sciences-FS-10550-M-Transfer-Station-6252
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Sandpiper S05B2P1TPNS000 Transfer Pump

Sandpiper S05B2P1TPNS000 Transfer Pump

Cambridge Scientific ID #'s: 11691, 11690

Features:

 

Non-Metallic Transfer Pump



Specifications:

 

 

  • Max Flow Rate (GPM): 14
  • Max Flow Rate (LPM): 53
  • Suction Lift Wet (in Hâ‚‚O): 120
  • Suction Lift Wet (mm of Hâ‚‚O): 3100
  • Suction Lift Wet (in Hg): 8.8
  • Suction Lift Wet (mm Hg): 537
  • Air Consumption (SCFM): 16
  • Air Consumption (m³/hr): 27.2
  • Max Air Inlet Pressure (PSI): 100
  • Max Air Inlet Pressure (bar): 6.9
  • Particulates, Max size dia (in): 0.125
  • Max Particulates Size Diameter (cm): 3.2
  • Max Temperature (° F): 150
  • Max Temperature (° C): 66
  • Viscosity, Max (cP): 11000
  • Length (in): 10.125
  • Height (in): 7.0625
  • Width (in): 11.3125
  • Length (cm): 25.72
  • Height (cm): 17.94
  • Width (cm): 28.73

 

 

Learn More
Sandpiper-S05B2P1TPNS000-Transfer-Pump-11691
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad Trans-Blot SD  Semi-Dry Transfer Cell

Bio-Rad Trans-Blot SD Semi-Dry Transfer Cell

Cambridge Scientific ID #'s: 16546, 10519

Features and Benefits

 

  • Transfers take place in as little as 15–60 min
  • Minimal buffer requirements save money
  • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
  • Single-step locking system allows simple, speedy setup
  • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
  • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
  • Safety cover breaks the electrical current when lifted, preventing electrical shock

 

Applications and Uses

 

  • Western blotting
  • Nucleic acid transfer
  • Northern and Southern blot transfers in 10–35 min
  • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

 

Features:

 

  • Maximum gel size (W x L), cm: 24 x 16
  • Buffer requirement, ml: 200
  • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
  • Recommended power supply: PowerPac HC (High Current)
  • Dimensions (W x L x H), cm: 37 x 24 x 11
  • Weight, kg/lb: 3.6/7.9
Learn More
Bio-Rad-Trans-Blot-SD-Semi-Dry-Transfer-Cell-16546
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

Bio-Rad Trans-Blot SD Cell Semi-Dry Transfer Cell

Cambridge ID #: 22074

Features and Benefits

 

  • Transfers take place in as little as 15–60 min
  • Minimal buffer requirements save money
  • Capacity to transfer up to four Mini-PROTEAN precast or handcast gels, or three Criterion gels
  • Single-step locking system allows simple, speedy setup
  • Platinum-coated titanium anode plate electrodes and stainless-steel cathode plate electrodes provide consistent and reliable transfers, durability, and long life
  • Extra plastic templates required by other semi-dry blotters to prevent electrode short circuits are unnecessary
  • Safety cover breaks the electrical current when lifted, preventing electrical shock

 

Applications and Uses

 

  • Western blotting
  • Nucleic acid transfer
  • Northern and Southern blot transfers in 10–35 min
  • Transfer of DNA and RNA using the unique agarose gel semi-dry blotting support frame

 

Features:

 

  • Maximum gel size (W x L), cm: 24 x 16
  • Buffer requirement, ml: 200
  • Gel capacity: 4 Mini-PROTEAN precast or handcast gels, 3 Criterion gels, 1–3 PROTEAN II gel sandwiches
  • Recommended power supply: PowerPac HC (High Current)
  • Dimensions (W x L x H), cm: 37 x 24 x 11
  • Weight, kg/lb: 3.6/7.9
Learn More
Bio-Rad-Trans-Blot-SD-Cell-Semi-Dry-Transfer-Cell-22074
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

Bio-Rad Trans-Blot Turbo System Semi-Dry Transfer Cell

Cambridge ID #: 24395

The Trans-Blot Turbo transfer system reduces western blotting setup time to 1 minute and transfer to as little as 3 without sacrificing sensitivity.

Paired with Trans-Blot Turbo transfer packs or Trans-Blot RTA kits, this system provides a complete solution for fast, high-efficiency transfer of even high molecular weight proteins.
Used on its own or as part of the V3 Western Workflow, the Trans-Blot Turbo system is the no-compromise solution for high-performance western blotting.

Features:

  • Fast Transfer Times: Transfer your proteins in as little as 3 minutes.
  • High Throughput: Transfer up to 4 mini or 2 midi gels simultaneously.
  • Flexible Design: Easily customize transfer conditions; compatible with traditional semi-dry consumables.
  • Ease of Use: Reduce set-up time to only 1 minute from opening the gel cassette to starting the transfer.
  • Two Blotting Sandwich Options: Trans-Blot Turbo Transfer Packs or Trans-Blot Ready-to-Assemble Kits
Learn More
Bio-Rad-Trans-Blot-Turbo-System-Semi-Dry-Transfer-Cell-24395
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 11-500-49H Hot Plate

Fisher Scientific 11-500-49H Hot Plate

Cambridge ID #: 7313

Description:

Your Fisher hotplate, stirrer and stirring hotplate are general purpose heating and/or stirring devices intended for general laboratory procedures. Three sizes are available, referring to the size of the top plate in inches: 4x4, 7x7, and 10x10. All three sizes are available as a hotplate, stirrer, or combination stirring hotplate. In addition, all three are available with a ceramic top plate. The 7x7 size is also available with an aluminum top plate. The catalog numbers above refer to the units that are available. A vessel with a flat bottom is recommended on the hotplate and stirring hotplate for ideal heat transfer. Glass containers should be made of heat resistant glass such as borosilicate. Avoid soda lime glass containers, metal containers, sandbaths, or vessels with a rim around the bottom as these could cause damage to the hot plate and stirring hot plate.

Specifications:

  • 7x7 ceramic top models
  • 150°C (302°F) - 540°C (1004°F)
  • 100 - 1000 RPM
Learn More
Fisher-Scientific-11-500-49H-Hot-Plate-7313
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1290 Infinity UPLC System

Agilent 1290 Infinity UPLC System

Cambridge ID #: 20004

The Agilent 1290 Infinity Binary LC is not only the most powerful but also the most adaptive UHPLC system available. No matter what your laboratory requires, the 1290 Infinity Binary LC can handle the widest range of applications; UHPLC methods, legacy HPLC methods, HPLC-to-UHPLC method transfer, method development, multi-compound screening, LC/MS coupling, and many more.

 

Features:

  • Most adaptive  – emulates other HPLC and UPLC systems, connects to all Agilent and many non-Agilent software
  • Highest performance & flexibility – by any measure
  • HPLC-like service costs – UHPLC productivity

 

Includes:

  • G1316C TTC Column Compartment
  • G4226A Autosampler
  • G1330B Autosampler Thermostat
  • G4220A Binary pump
  • Tray
  • 1200 Instant Pilot
Learn More
Agilent-1290-Infinity-UPLC-System-20004
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Plas-Labs 815-PGB *NEW* Glove Box

Plas-Labs 815-PGB *NEW* Glove Box

Cambridge ID #: 17520

Features:

The La Petite Glove Box is comprised of essentially two components. The top and bottom are sealed using a revolutionary new gel used in the clean room industry. The unit is only two-thirds the size of the "Basic Glove Box", (818-GB).

Specifications:

  • ID: 31.5 w x 25.5 d x 21.5"h, 80 x 65 x 55 cm
  • OD: 49 w x 29 d x 22" h, 124,5 x 74 x 56 cm (widths include transfer chamber)
  • Volume: 9.5 cu. Ft., 269 L
  • Optically clear, one piece formed top is unbreakable.
  • Bright white one piece bottom formed out of high temperature Noryl has "easy clean" corners.
  • Gel Sealant.
  • Stainless steel clamps have security locking features.
  • Large access door (12" opening)
  • Four ground key-cock valves for purging and gas entry.
  • Adjustable Rh gauge.
  • "Weathertite" duplex electrical outlet with safety covers.
  • Transparent vacuum capable transfer chamber 12" long x 9.75" ID.
  • White leveling plate for transferring liquids.
  • All stainless steel clamps are adjustable.
  • Vacuum gauge on transfer chambers.

 

 

Learn More
Plas-Labs-815-PGB-*NEW*-Glove-Box-17520
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Plas-Labs 830-ABDA/SP Glove Box

Plas-Labs 830-ABDA/SP Glove Box

Cambridge ID #: 23261

Specifications:

  • Inside Dimensions: 48"w x 29"d x 32"h 
  • Outside Dimensions: (includes 12" long transfer chamber) 63"w x 31"d x 35" h 
  • Approximate Volume:8 Cu. Ft., 730 Liters
  • Approximate Shipping Weight: 440 lbs.        
  • Top Opening: 24" x 42"
Learn More
Plas-Labs-830-ABDA-SP-Glove-Box-23261
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perkin Elmer 9600 PCR / Thermal Cyclers

Perkin Elmer 9600 PCR / Thermal Cyclers

Cambridge ID #: 6302

Description:

  • Reproducibility Of Cycle Times
  • Uniformity Of PCR Yields For Samples
  • Thin-Walled MicroAmp Reaction Tubes Allowing Efficient Heat
  • Transfer and Improving Equilibration Times
  • High Speed of Heating and Cooling
  • Heated Cover Assuring That Tubes Fit Tightly In The Wells
  • Oil-Free Operation

Specifications:

  • Dimensions: 30.5 x 52 x 61 cm
  • Weight: 40.5 kg
  • Input: 120 VAC, 60 Hz
  • Display: 40 Character Blue Luminescent Display
  • Temperature Range: 4°C to 99.9°C
Learn More
Perkin-Elmer-9600-PCR---Thermal-Cyclers-6302
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Mettler Toledo AT261 Analytical Balance

Mettler Toledo AT261 Analytical Balance

Cambridge Scientific ID #'s: 24703, 25289, 25102

Features:

  • Standard asynchronous serial format
  • Baud rate and parity freely selectable
  • Bidirectional data transfer
  • Break recognition
  • Galvanic isolation
  • RS-232 and 20 mA current loop
  • Several handshake modes
  • 7-bit ASCII character set
  • Extensive command set – access to virtually all balance parameters
  • Easy connection to printers and computers

 

Specifications:

  • Readability: 0.01 mg - 0.1 mg
  • Weighing capacity: 62 g - 205 g
  • Taring range (by subtraction): 0…205 g
  • Reproducibility (s) 0...50 g: 0.015 mg
  • Reproducibility (s) 50...100 g: 0.02mg, 0.03 mg
  • Reproducibility (s) 100...200 g: 0.03mg, 0.05mg
  • Linearity: ± 0.03mg, ± 0.15mg
  • Linearity referred to 5 g: ± 0.02 mg
  • Stabilization time (typical) variable with vibration adapter: 8,12,18 s - 3,5,7 s
  • Built-in calibration weights: 2x100 g. Measured to ±0.1 mg (±0.01 mg AT20/21) at an air density of 1200 mg/l on virtual mass with density 8.0 g/cm3.
  • Calibration FACT: Fully automatic motorized self-calibration with two built-in weights (manual triggering also possible). Test possibility to check the calibration.
  • Calibration with external weight: 200 g
  • Display with METTLER Deltatrac: LCD (liquid crystal)
  • Display sequence: 0.2...0.4 s variable
  • Sensitivity drift (5...40°C): Maximum deviation with automatic self-calibration ±0.00015%, (with automatic self-calibration switched off) 1 ppm/°C.
  • Linearization: Automatic self-linearization of the weighing curve (simultaneously with motorized calibration FACT).
  • Data interface: CL and RS232C, bidirectional, built in as standard, all lines galvanically separated.
  • Glass draft shield: No hindering guideways; automatic motorized opening or at a keystroke. 
  • Inner draft shield AT: Standard
  • AC adapter (to national codes): Voltage 115 V or 230 V, admissible voltage fluctuations: +15...-20%. Frequency: 50...60 Hz; power consumption 15,5W max.
  • Admissible ambient conditions: Temperature: 5...40 °C; relative humidity: 25...85% (non-condensing). Height above sea level: -500...+6000 m.
  • Weighing pan feedthrough for below-the-balance weighing: 80x80 [mm]; stainless steel
  • Measures: Free height above weighing pan 239 mm, Balance housing 241x433x289 (WxLxH), AC adapter 115x140x53mm (WxLxH)
  • Weight: Balance 9.3 kg, AC adapter 1.2 kg
  • Vibration adapter (symbol [ ~ ]): 3 settings for matching to location: suppression of the effect of vibrations.
  • Weighing process adapt. (symbol [ ]): 4 settings for matching to weighing application: dispensing, universal setting, absolute weighing, special applications.
  • Stability detection (ASD): 8 settings with different tolerance thresholds (off, 1...7). 
  • Weight unit 1: Freely selectable in the configuration register: g, mg, oz, ozt, tl, GN, dwt, ct, C.M., mo.
  • Weight unit 2 (incl. applications): Freely selectable in the configuration register: g, mg, oz, ozt, tl, GN, dwt, ct, C.M., mo, PCS, Stk, %. The selected weight units 1 and 2 can be switched at a keystroke.
  • Applications: PCS, Stk. (piece counting, reference 10, 20, 50, 100) and % (percent weighing) are built-in applications.
Learn More
Mettler-Toledo-AT261-Analytical-Balance-24703
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
 FluorChem SP Gel Imaging SystemImage Coming Soon

FluorChem SP Gel Imaging System

Cambridge Scientific ID #'s: 23904, 26316

Features: 

 

Features for the Photometrics Cool SNAP K4: 

  • 20-MHz readout: High-speed, high-sensitivity image capture
  • 2048 x 2048 imaging array: Resolves fine detail
  • 7.4 x 7.4-ìm pixels: Ideally matched to optical microscope
  • Interline-transfer, progressive-scan CCD: Eliminates camera vibration and facilitates fast triggering
  • Flexible binning and readout: Increases light sensitivity while increasing the frame rate
  • 12-bit digitization: Quantifies bright and dim signals in the same image
  • Thermoelectric cooling: Long integration times for higher sensitivity
  • Enhanced quantum efficiency: Provides higher sensitivity than typical interline cameras
  • C-mount: Easily attaches to microscopes, standard lenses, or optical equipment
  • Acquisition software: Captures, analyzes, and saves high-resolution images
  • PCI interface: High-bandwidth, uninterrupted data transfer
  • PVCam, Circular buffers, Device sequencing: Supported by numerous third-party software packages, Real-time focus, Precise integration with shutters, filter wheels, etc. (Compatible with Windows XP/Vista 32, Mac OS X, and Linux (kernel versions 2.4 and 2.6.8))
  • CCD image sensor: Kodak KAI-4020M; interline-transfer, progressive-scan device with microlenses
  • CCD format: 2048 x 2048 imaging array, 7.4 x 7.4-um pixels, 15.16 x 15.16-mm imaging area (optically centered)
  • Linear full well: 30,000 e- (single pixel); 60,000 e- (2 x 2 binned pixel)
  • Read noise: ≤10 e- rms @ 20 MHz
  • Nonlinearity: <1%
  • Digitizer type: 12 bits @ 20 MHz
  • CCD temperature: -25ͦC (regulated)
  • Dark current : 0.1 e-/p/s @ -25ͦC
  • Operating environment: 0 to 30ͦC ambient, 0 to 80% relative humidity noncondensing
  • I/O TTL (trigger/status): trigger, invert, inhibit, exposing, interline shift, frame readout, 8-bit TTL (programmable), 8-bit DACs(two)

Compare this against “Features of Gel Doc XRS+ system”: 

  • Chemiluminescence: Yes
  • Fluorescence: Yes
  • Colorimetry/densitometry: Yes
  • Gel documentation: Yes  

Hardware Specifications        

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 26X 35 cm
  • Excitation source: Trans-UV and epi-white are standard (302 nm included, with 254 and 365 nm available as options)
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: super cooled CCD
  • Image resolution: 4 megapixels
  • Pixel size (H x V): 6.45 x 6.45 µm
  • Filter holder: 3 positions (2 for filters, 1 without filter)
  • Emission filters: 1 included (standard), 3 optional
  • Dynamic range: >4.0 orders of magnitude
  • Pixel density (gray levels): 65,535
  • Dynamic flat fielding: Application specific, for all applications
  • Instrument size (L x W x H): 36 x 60 x 96 cm
  • Instrument weight: 32 kg

 Operating Ranges         

  • Operating voltage: 110/115/230 V AC nominal
  • Operating temperature: 10–28°C (21°C recommended)
  • Operating humidity: <70% noncondensing

 Automation Capabilities            

  • Workflow automated selection: Application driven; user selected or recalled by a protocol
  • Workflow automated execution: Controlled by a protocol via application specific setup for image area, illumination source, filter, analysis, and reporting
  • Workflow reproducibility: 100% repeatability via recallable protocols; from image capture to quantitative analysis and reports
  • Autofocus: Precalibrated focus for any zoom setting or sample height
  • Image flat fielding: Dynamic; precalibrated and optimized per application
  • Autoexposure: 2 user-defined modes (intense or faint bands)
Learn More
-FluorChem-SP-Gel-Imaging-System-23904
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Agilent 6890 Plus Gas Chromatograph w/ 5973 Mass Spec and 7683 Autosampler GC/MS

Cambridge ID #: 14612

Includes:

  • Agilent 6890 Plus Gas Chromatograph
  • 7683 100 Vial Autosampler with Injector Tower
  • Agilent 5973
  • Edwards RV3 Vacuum Pump
  • Computer Loaded with Chemstation Software
  • Monitor

 

Specifications:

Mass Spectrometer:  

  • Mode (standard): EI
  • Modes (optional): PCI, NCI EI with CI source
  • Ion source type: 5 - 241.5 eV
  • Ionization energy: 0 - 315 uA
  • Ionization current: 100 - 350 'C
  • Transfer line temperature: 150 - 300 'C
  • Quadrupole temperature: 150 - 200 'C
  • Mass filter: Monolithic hyperbolic quadrupole
  • Mass filter protection: Entrance lens
  • Mass range:6 - 800 amu
  • Mass resolution: Unit mass adjustable by tune
  • Mass axis stability: Better than 0.10 amu/ 48 h
  • Detector: EM with replacement horn
  • Dynamic range (electronic): 10e6
  • Scan rate (electronic): 10,000 amu/s
  • Write-to-disk: 8,000 amu/s
  • SIM: 30 ions x 50 groups
  • Pumping system: Turbomolecular pump
  • Total flow: 2 mL/min (standard turbo)

Gas Chromatograph: 

  • Automatic injector (optional): Automatic alignment, fast injection
  • Liner replacement: Compatible with optional flip-top inlet sealing system
  • Injector: Split-splitless (standard), others available
  • Oven temperature: Ambient +4 - 450 'C
  • Oven ramps / plateaus: 6-7
  • Carrier gases: Helium, hydrogen, nitrogen, argon
  • Electronic pnuematic control: Auto pressure regulation for split/splitless, septum purge
  • Carrier gas control modes: Constant pressure and flow modes; pressure and flow programmable
  • Pressure range: 0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected
  • Retention-time locking:RTL ready
  • Flow control: Compatible with optional microfluidics controller
Learn More
Agilent-6890-Plus-Gas-Chromatograph-w--5973-Mass-Spec-and-7683-Autosampler-GC-MS-14612
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping