Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Uplc System: 1-15 of 520

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1290 Infinity Binary UPLC Stack HPLC System

Agilent 1290 Infinity Binary UPLC Stack HPLC System

Cambridge ID #: 20004

The Agilent 1290 Infinity Binary LC is not only the most powerful but also the most adaptive UHPLC system available. No matter what your laboratory requires, the 1290 Infinity Binary LC can handle the widest range of applications; UHPLC methods, legacy HPLC methods, HPLC-to-UHPLC method transfer, method development, multi-compound screening, LC/MS coupling, and many more.

 

Features:

  • Most adaptive  – emulates other HPLC and UPLC systems, connects to all Agilent and many non-Agilent software
  • Highest performance & flexibility – by any measure
  • HPLC-like service costs – UHPLC productivity

 

Includes:

  • G1316C TTC Column Compartment
  • G4226A Autosampler
  • G1330B Autosampler Thermostat
  • G4220A Binary pump
  • Tray
  • 1200 Instant Pilot
Learn More
Agilent-1290-Infinity-Binary-UPLC-Stack-HPLC-System-20004
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity H Class Stack UPLC System

Waters Acquity H Class Stack UPLC System

Cambridge ID #: 15385

The Waters ACQUITY UPLC H-Class System delivers the flexibility of quaternary solvent blending with the advanced performance of UPLC® separations. The system's holistic design is targeted for routine analysis and method development use and is perfectly suited for running both HPLC and UPLC applications while still realizing the improved resolution and sensitivity of UPLC separations.

 

Includes:

  • TUV Detector (PDA Detector $1000 additional)
  • Sample Manager - FTN
  • Column Manager to control up to 4 Columns
  • Quaternary Solvent Manager
    • 15,000 psi up to 1.0 mL/min,
    • 9000 psi up to 2.0 mL/min
  • Computer Loaded with Empower

 

Specifications:

  • Dwell volume (total system): <400 ~L (includes standard 100 ~L mixer)
  • Integrated leak management: Leak sensors, as standard, and safe leak handling
  • Quantum synchronization: Injection synchronization between pump and sample manager enhances retention time reproducibility
  • Set table flow rate range:
    • 01 0 to 2.000 mLlmin, in 0.001 mL increments (firmware version 1.5x and earlier)
    • 010 to 2.200 mL/min, in 0.001 mL increments (firmware version 1.60)
    • 001 to 2.200 mLlmin in 0.001 mL increments (firmware version 1.65 and later)
  • Maximum operating pressure:
    • 15,000 psi up to 1.0 mL/min, 9000 psi up to 2.0 mL/min (firmware version l.5x and earlier)
    • 15,000 psi up to 1.0 mL/min, 7800 psi up to 2.2 mL/min (firmware version 1.6x and later)
  • pH range: 2 to 12
  • Unattended operation: Leak sensors and safe leak handling, full 96-hour diagnostic data display through console software
  • Cycle time: <30s Inject to Inject
Learn More
Waters-Acquity-H-Class-Stack-UPLC-System-15385
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Stack UPLC System

Waters Acquity Stack UPLC System

Cambridge ID #: 9582

Optional UPLC Sample Organizer

Optional Service Contract, Installation, and Training also available

 

The Waters ACQUITY UPLC System provides an integrated configuration for solvent and XYZZ sample management designed for use with ACQUITY UPLC chemistries. The core ACQUITY UPLC System comprises a Binary Solvent Manager, a Sample Manager with integral Column

Heater, and a Solvents Tray. The optional Sample Organizer is available for expanded sample capacity. The full line of Waters MS Technologies products, from single quadrupole to hybrid quadrupole time-of-flight are also available.

 

Includes:

  • TUV Detector or PDA Detector ($1000 more)
  • Sample Manager
  • Column Heater (1 columns)
    • (Optional Column Manager to control up to 4 Columns $2000 extra)
  • Binary Solvent Manager
    • 15000 psi Max Pressure
    • 1034 bars Max Pressure
  • Computer Loaded with Empower
Learn More
Waters-Acquity-Stack-UPLC-System-9582
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity TQD w/ Waters Acquity UPLC LC/MS/MS  System

Waters Acquity TQD w/ Waters Acquity UPLC LC/MS/MS System

Cambridge ID #: 14849

Includes 1 year Service Contract, Installation, and a PM at 6 months

Optional TUV or PDA Detector

 

Developed for integrated UPLC/MS/MS quantitative applications, the Waters ACQUITY TQD features the highest levels of tandem quadrupole MS selectivity, robustness, speed, and accuracy.   To maximize the analytical advantages of UltraPerformance LC (UPLC), the ACQUITY TQD operates at the highest data acquisition rates. When integrated with the ACQUITY UPLC System, the ACQUITY TQD gives you class-leading analytical detection limits, resolution, and sample throughput for all of your quantitative applications: bioanalysis, ADME screening, food safety, environmental monitoring, clinical, forensic, and more.

 

Includes:

  • Waters TQD UPLC/MS/MS Mass Spectrometer
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Roughing Pump
  • Windows 7 Computer loaded w/ Mass Lynx 4.1 SCN 805.IVD
  • Flex Cart for UPLC
  • Waters Acquity UPLC
    • Column Manager
    • Sample Manager
    • Binary Solvent Manager
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Performance Specifications:

  • Acquisition modes
    • Full scan MS
    • Product ion scan
    • Precursor ion scan
    • Constant neutral loss
    • Selected Ion Recording (SIR)
    • Multiple Reaction Monitoring (MRM)
  • Survey scan modes: Full scan MS triggered product ion scan
  • Mass range: 2 to 2048 m/z
  • Scan speed: Up to 10,000 Da/s
  • Examples of achievable acquisition rates:
    • 10 scans per second (m/z 100 to 1000)
    • 20 scans per second (m/z 50 to 500)
  • Mass stability: Mass drift is < 0.1 Da over a 24 hour period
  • Linearity of response: The linearity of response relative to sample concentration for a specified compound is five orders of magnitude from the limit of detection
  • Polarity switching time: 20 ms to switch between positive and negat ive ion modes
  • MRM acquisition rate: Minimum dwell time of 3 ms per MRM channel
  • Inter-channel cross talk: The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 10 ms and an inter-channel delay time of 10 ms, will be less than 0.02%.
  • Number of MRM channels: Up to 16,384 MRM channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 1024 MRM channels when operating in GLP/secure mode (32 functions, 32 channels per function).
  • Mass resolution: Automatically adjusted (InteUiStart) to desired resolu tion; The vaUey between the 2034.63 Da and 2035.63 Da peaks is < 12% of the average height of the two peaks
  • MRM sensitivity (ESI+) : A 1 pg on-column injection of reserpine will give a chromatographic signal-ta-noise greater than 2,000:1 (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition mil 609 > 195).
  • MRM sensitivity (ESI-): A five pg loop injection of chloramphenicol, wi th a mobile phase flow rate of 200 ~lImin will give a chromatographic signal-ta-noise for the transition 321 > 152 mlz greater than 180: 1.
  • MRM sensitivity (APCI+): A 100 pg loop injection of 17-a-hydroxyprogesterone, with a mobile phase flow rate of 1000 IJLlmin will give a chromatographic signal-ta-noise for the transition 331 > 109 mil > 150:1.
Learn More
Waters-Acquity-TQD-w--Waters-Acquity-UPLC-LC-MS-MS--System-14849
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

AB Sciex API 4000 Qtrap w/ Shimadzu 20AD UPLC LC/MS/MS Q Trap System

Cambridge ID #: 13945

Includes 1 year Service Contract, Installation, and a PM at 6 months

Method Development and Training also Available

 

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with APCI and ESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Shimadzu Prominence 20 UFLC  Shimadzu
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO Column Oven
    • Shimadzu CBM-20A Communication Module
  • CTC Autosampler
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%
Learn More
AB-Sciex-API-4000-Qtrap-w--Shimadzu-20AD-UPLC-LC-MS-MS-Q-Trap-System-13945
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 4000 w/ Shimadzu 20AC UPLC LC/MS/MS  System

AB Sciex API 4000 w/ Shimadzu 20AC UPLC LC/MS/MS System

Cambridge ID #: 18606

Includes:

  • AB Sciex API4000 LC/MS/MS
  • Enhanced high performance triple quadrupole mass spectrometer system
  • Line transformers
  • Turbo V Ion Source (with HESI probes)
  • Roughing Pump
  • Windows 7 Computer loaded w/ Analyst Software 1.6
  • Cart
  • Optional Shimadzu Front End
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

Specifications:

  • Detector type: Pulse Counting CEM
  • Dynamic Range: 5 orders of magnitude
  • Ionization Sources: ESI, APCI
  • Mass Accuracy / Stability: 0.1 Da over 8 hours, 0.15 Da over 24 hours
  • Mass Range: 5-3,000
  • Polarity Switching Time: 700 ms
  • Scan Speed (Quad): 24,000 Da/sec
  • Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  • Sensitivity MRM Mode: 200 fg Reserpine on column: S/N > 1,200, C.V. < 5%

Optional Shimadzu UFLC System Components:

  • SIL-20AC
  • LC-20AB
  • CTO-20AC
  • CBM-20A
  • DGU-20A5
Learn More
AB-Sciex-API-4000-w--Shimadzu-20AC-UPLC-LC-MS-MS--System-18606
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Binary Solvent Manager UPLC Binary Solvent Manager

Waters Acquity Binary Solvent Manager UPLC Binary Solvent Manager

Cambridge Scientific ID #'s: 15770, 15341

Specifications:

  • Number of solvents: Up to four: in any combination of two: Al or A2 and Bl or B2
  • Solvent storage: Solvents Tray accommodates up to four chromatographic solvents, two Sample Manager wash solvents and one Binary Solvent Manager seal wash solvent
  • Solvent conditioning: Vacuum degassing (Six-channel): one channel per solvent, and two channels for Sample Manager wash solvents
  • Operating flow rate range: 010 to 2.000 mL/min, in 0.001 mL increments
  • Compressibility compensation: Automatic and continuous
  • Effective system delay volume: <120 ulL, independent of system backpressure (with standard 50-ilL mixer installed)
  • Plunger seal wash: Integral, active, programmable
  • Gradient profiles: Eleven gradient curves [including linear, step (2), concave (4), and convex (4)]
  • Wet prime: Automatic
  • Maximum operating pressure: 15,000 psi up to 1 mL/min, 9,000 psi up to 2 mL/min per pump, not more than 15,000 psi total
  • Composition accuracy:
    • ±0.5% absolute (full scale) from 5 to 95% of flow rates
    • from 0.5 to 2.0 mLlmin (Contact Waters for conditions used)
  • Composition precision: 0.15% RSO or ±0.04 min SO, whichever is greater, based on retention time
  • Flow precision: 0.075% RSO or ±0.02 min SO, six replicates, based on retention time or volumetric measures (0.500 to 2.000 ml/min)
  • Flow accuracy: ± 1.0% at 0.5 mL/min with degassed methanol, per Waters AQT/SystemsQT protocol
  • Primary wetted materials: 316 stainless steel, UHMWPE, sapphire, ruby, FEP, PTFE, ETFE, diamond-like coating, PEEK and PEEK alloys, titanium alloys
  • Unattended operation: Leak sensors, full diagnostic data captured through console software
Learn More
Waters-Acquity-Binary-Solvent-Manager-UPLC-Binary-Solvent-Manager-15770
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters Acquity H Class Column Manager UPLC Column Manager

Waters Acquity H Class Column Manager UPLC Column Manager

Cambridge ID #: 15342

Specifications:

  • Column capacity:
    • CM-A: Two columns, as standard (maximum length of 150 mm with filter or guard column)
    • or four columns (maximum length of 50 mm) can be supported with optional tubing kit,
    • up to 4.6 mm internal diameter (1.0.)
    • CM-Aux: Two columns (maximum length of 150 mm, with filter or guard column) - up to
    • two CM-Aux units can be configured with one CM-A for support of up to six columns
  • Switching valves: Two nine-port, eight-position valves (CM-A only); provides programmable, automatic, random access switching, waste and bypass positions for rapid solvent changeover
  • Temperature Range:
    • 0 to 90.0 ·C, set table in 0.1 ·C increments
    • Two independent heatl cool zones per module, up to six zones in stacked configuration
  • Temperature Accuracy: ±0.5 ·C
  • Temperature Stability: ±0.3 ·C
  • Solvent conditioning: Active pre-heating as standard
  • Column tracking: eCord Technology column information management tracks and archives column usage history
  • 20 support: Optional
Learn More
Waters-Acquity-H-Class-Column-Manager-UPLC-Column-Manager-15342
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity Sample manager UPLC Sample Manager

Waters Acquity Sample manager UPLC Sample Manager

Cambridge Scientific ID #'s: 15340, 15769

Specifications:

  • Number of sample plates: Total of two plates, expandable to up to 22 plates with optional Sample Organizer (see below):
    • 96 and 384 microtiter plates
    • 48 position 2.00-mL vial plates
    • 48 position 0.65-mL micro-centrifuge tube plates
    • 24 position 1.50-mL micro-centrifuge tube plates
  • Maximum sample capacity: 768 in two 384-well plates; expandable to up to 8,448 samples with optional Sample Organizer
  • Number of sample injections: 1 to 99 injections per sample
  • Injection volume range: 0.1 to 50.0 iJL, in 0.1 iJL increments, partial or full loop mode; 10ul loop is standard; 1, 2, 5, 20, and 50-uL loops also available
  • Sample delivery precision(full loop injection mode): < 0.3% RSO, full loop, standard lO-iJL loop (default wash/purge conditions), per Waters AQT/SystemsQT protocol
  • Sample delivery precision(PLNO injection mode): < 1% RSO within 20% to 75% of loop volume for 1, 2, 5, 10, 20, and 50-iJL loops, UV detection
  • Injector linearity: > 0.999 coefficient of deviation (from 20% to 75%, partial loop overfill mode (PLNO injection mode), per Waters' AQT/SystemsQT protocol
  • Sample temperature control:0 to 40.0 ·C, settable in 0.1 ·C increments (assumes an ambient temperature of 25.0 ·C). At an ambient temperature of 21.0 ·C or lower the sample manager will maintain the temperature of the sample compartment down to 4.0 ·C with a tolerance of -2.0/+6.0 ·C, when configured with the maximum number of vials and/or plates
  • Injection cycle time:
    • < 15 sec between multipe injections with "load ahead" enabled
    • 30 sec with single weak wash, lO-iJL loop, pressure assist mode
  • Sample probe: XYZZ based needle-in-needle design
  • Minimum sample required: 5 uL residual, using maximum recovery 2-mL vials (zero offset)
  • Wash solvents: Two degassed: strong solvent and weak wash solvent, programmable to suit application
  • Sample carryover: < 0.005% or < 2.000 nL, whichever is greater
  • Advanced operations: Loop off-line mode, load ahead
  • Unattended operation: Leak sensors, full diagnostic data control captured through console software
  • Primary wetted material: Titanium alloy, 316 stainless steel, fluoropolymer, fluoroelastomer, PPS alloy, PEEK alloy, PPS, PEEK, OLC coating, gold
Learn More
Waters-Acquity-Sample-manager-UPLC-Sample-Manager-15340
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters Acquity TUV Detector UPLC TUV Detector

Waters Acquity TUV Detector UPLC TUV Detector

Cambridge Scientific ID #'s: 12726, 15339, 15345

The ACQUITY UPLC TUV Detector is a tunable, dual wavelength ultraviolet/visible (UV/Vis) detector that offers optimal linearity, resolution, and sensitivity for UPLC/UV separations.  It features uniquely designed, patented, light-guiding flow cell technology, low-noise performance (6 μAU), and support for data rates up to 80 Hz.  The ACQUITY UPLC TUV Detector, coupled with our innovative ACQUITY UPLC Column chemistries and separations modules, leverages ultra-low dwell volume and low-noise, high-speed detection to bring productivity, sensitivity, and resolution that are unprecedented in HPLC techniques being used in the laboratory today.

 

Specifications:

  • Wavelength range: 190 to 700 nm
  • Wavelength accuracy: ±1 nm
  • Linearity range: Deviation at 2.5 AU ≤5%, propylparaben, at 257 nm
  • Baseline noise:6 x 10^-3 AU, at 230 nm, 10 mm shunt cell, 1.0 second filter time constant
  • Drift: ≤5.0 x 10^-4 AU/hour/°C at 230 nm
  • Sampling rate: Up to 80 points/s
  • Unattended operation: Leak sensors, full diagnostic data captured through console software
  • Light source: Prealigned, intelligent technology Deuterium lamp
  • Flow cell design: Light-guiding UPLC flow cell with intelligent chip technology
  • Path length: 10 mm (analytical flow cell)
  • Cell volume: 500 nL (analytical flow cell)
  • Pressure limit: 1000 psi (all flow cells)
  • Wetted materials: 316 stainless steel, fused silica, Teflon AF, PEEK (analytical flow cell)
  • Optical bandwidth: 5 nm
Learn More
Waters-Acquity-TUV-Detector-UPLC-TUV-Detector-12726
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Waters Sample Organizer UPLC Autosampler Loader

Waters Sample Organizer UPLC Autosampler Loader

Cambridge Scientific ID #'s: 14266, 14267, 14268

The ACQUITY UPLC Sample Organizer increases the level of automation and sample processing throughput of the ACQUITY UPLC System. It extends the capacity of the system by more than tenfold for samples in standard ANSI-compliant 96 or 384 well plates; or more than threefold for samples in conventional 2 mL vials.

 

Features:

  • Plates are transferred in a programmable order from the Sample Organizer to the ACQUITY UPLC System Sample Manager for processing
  • Plate exchange shuttle replaces a plate in the Sample Manager within 15 seconds to support high sample-throughput processing
  • Shelves accessed through the large swing-open front door and slide in easily
  • Accepts any combination of ANSI-compliant well plates and vial holders
  • Temperature control of 4 to 40 °C in 1 °C increments
  • Small footprint
  • Sample capacities:
    • 22 standard ANSI/SBS-compliant 96 or 384 well plates
    • 12 intermediate well plates
    • 8 x 48 – 2mL vials
    • 8 x 24 – 4mL vials
Learn More
Waters-Sample-Organizer-UPLC-Autosampler-Loader-14266
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
AB Sciex API 4500 LC/MS/MS w/ Shimadzu Prominence LC-20AD UFLC System  LC/MS/MS  System

AB Sciex API 4500 LC/MS/MS w/ Shimadzu Prominence LC-20AD UFLC System LC/MS/MS System

Cambridge ID #: 17390

 

This LCMS brings you the best in quantitative sensitivity and robustness to expand upon the experiments going beyond MRM, and give you substantial improvements in data quality.

Includes:

  • AB Sciex 4500 LC/MS/MS
  • Shimadzu Prominence 20 UFLC  
    • Shimadzu DGU-20A3 Degasser
    • (2)Shimadzu LC_20AD Liquid Chromatograph
    • Shimadzu CTO-20AC Column Oven
    • Shimadzu SIL-20AC UFLC
  • Windows 7 Computer Loaded with Analyst 1.6 Software       

Specifications:

  • Sensitivity MRM: mode Reserpine 200 fg on column S/N > 2000  C.V. < 5%
  • Maximum scan speed: 12,000 Da/sec
  • Polarity switching time: 50 msec, in MRM and scheduled MRM (sMRM) modes
  • Minimum MRM dwell time: 1 msec
  • Mass range (m/z): 5-2000
  • Cross talk for reserpine 609/195: <0.5% cross talk detectable with 2 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion MS for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), and scheduled MRM (sMRM)
  • Detector type: AcQuRate Pulse Counting CEM
  • Dynamic range: 4 orders of magnitude
  • Ionization sources: Turbo V source housing with TurboIonSpray probe or APCI probe.
  • Maximum temperature: 750ºC
  • Flow rate compatibility: 5 μL/minute to 3 mL/minute
  • Power: 208V 50/60Hz AB Sciex 4500, 208V Vacuum Pump, 208V Peak N2 Generator, 115V Shimadzu UPLC
  • Dimensions: 37" x 33" x 55" Sciex 4500
  • Weight: 250lbs
Learn More
AB-Sciex-API-4500-LC-MS-MS-w--Shimadzu-Prominence-LC-20AD-UFLC-System-LC-MS-MS--System-17390
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System  LC/MS/MS Q Trap System

AB Sciex API 5500 Qtrap LC/MS/MS w/ Agilent 1200 HPLC System LC/MS/MS Q Trap System

Cambridge ID #: 14550

 Includes One Year Service Contract, PM at 6 Months, and Installation

 

The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses. This instrument provides an uncompromised combination of Linear Accelerator trap and triple quadrupole functionality, uniquely allowing both  qualitative and quantitative analyses to be carried out in a single experiment.

 

Includes:

  • AB Sciex 5500 Qtrap LC/MS/MS
  • Agilent 1200 HPLC System
    • Agilent G1322A Degasser
    • Agilent G1311A Quat Pump
    • Agilent G1315D DAD (Diode Array Detector)
  • Solvent Tray
  • Computer Loaded with Analyst 1.6 Software       

Specifications

  • Sensitivity MRM mode Reserpine: 50 fg on column S/N > 2000
  • V.: < 5%
  • Triple quad scan speed: 12,000 Da/sec
  • Linear ion trap scan speed: 20,000 Da/sec
  • Polarity switching time: 50 msec
  • Minimum MRM Dwell Time: 1 msec
  • Triple quad mass range (m/z): 5-1250
  • Linear ion trap mass range (m/z): 50-1000
  • Cross talk for Reserpine 609/195: No significant cross talk detectable with 1 msec dwell time and 3 msec inter-MRM pause time
  • Triple quadrupole mass stability: 0.1 Da over 24 hours
  • Scan types: Full scan MS and selected ion for both Q1 and Q3, product ion scan, precursor ion scan, neutral loss or gain scan, multiple reaction monitoring (MRM), enhanced MS scan, enhanced product ion scan, enhanced resolution scan, MS  scan, MRM3 scan, and TripleTrap scan modes
Learn More
AB-Sciex-API-5500-Qtrap-LC-MS-MS-w--Agilent-1200-HPLC-System-LC-MS-MS-Q-Trap-System-14550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1946D LC/MS System

Agilent 1100 Series - G1946D LC/MS System

Cambridge Scientific ID #'s: 10994, 12804

Includes Installation and One year Service Contract

 

Includes:

  • G1946D LC/MSD Mass Spectrometer Series SL
  • Roughing Pump
  • Optional Front end HPLC

Specifications

  • Mass Range: 2-3000m/z
  • Mass Accuracy: +/-.13 u within the calibrated mass range in scan mode
  • Mass Axis Stability: +- 0.13 u over 8 hours
  • Scan Speed:
    • 2500 u/s standard mode
    • 5250 u/s fast scan mode
  • SIM Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Selected ion monitoring of m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Scan Sensitivity:
    • ESI at 400 ul/min
    • APCI at 1000 ul/min
    • Scan range m/z 100-650
    • Scan speed 2500 u/s
    • Extracted ion at m/z 609.3
    • Positive ionization
    • Signal To Noise Ratio
    • Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
  • Multiple Signal Acquisition: Ability to cycle through four different acquisition modes on a scan-by-scan basis within a single run
Learn More
Agilent-1100-Series---G1946D-LC-MS-System-10994
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9592, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping