We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Vacuum Oven: 106-120 of 290

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Edwards PM-13195-820.3 Vacuum Pump

Edwards PM-13195-820.3 Vacuum Pump

Cambridge ID #: 20805

Features:

  • The Edwards D-LAB Diaphragm Pump features resistant PTFE heads, diaphragms, and Kalrez valves along with oil-free operation.

Specifications:

  • Maximum pressure: 1bar
  • Pumping speed: 10L/min
  • Ultimate vacuum: 100mbar
  • 115V 15A 50/60Hz Single Phase

 

Learn More
Edwards-PM-13195-820.3-Vacuum-Pump-20805
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Savant SG210D-120 Vacuum Concentrator/Gel Dryer

Savant SG210D-120 Vacuum Concentrator/Gel Dryer

Cambridge ID #: 6207

 

Features:

The Savant SC 200 is a Speed Vac Centrifugal Evaporator with radiant cover and rotor

 

Specifications:

  • Outside Dimensions: L 20" x W 28.5" x H 19"
  • Inside Dimensions: 16" Diameter x H 5"
  • Port - Vent Diameter: 2.5" Diameter Rotor Buckets (x8)
Learn More
Savant-SG210D-120-Vacuum-Concentrator-Gel-Dryer-6207
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV12 *NEW* Vacuum Pump

Edwards RV12 *NEW* Vacuum Pump

Cambridge ID #: 17436

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.65 litres
  • Oil max: 1 litres
  • Displacement :
      50Hz: 14.2 m3h-1 / 8.4 ft3min-1
      60Hz: 17 m3h-1 / 10 ft3min-1
  • Speed (Pneurop 6602)
      50Hz: 12 m3h-1 / 7.1 ft3min-1
      60Hz: 14.2 m3h-1 / 8.4 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 32 mbar / 24 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 290 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

 

Learn More
Edwards-RV12-*NEW*-Vacuum-Pump-17436
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 Vacuum Pump

Edwards RV3 Vacuum Pump

Cambridge ID #: 22427

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-Vacuum-Pump-22427
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 *NEW* Vacuum Pump

Edwards RV3 *NEW* Vacuum Pump

Cambridge ID #: 17433

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-*NEW*-Vacuum-Pump-17433
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV5 *NEW* Vacuum Pump

Edwards RV5 *NEW* Vacuum Pump

Cambridge ID #: 17434

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement :
      50Hz: 5.8 m3h-1 / 3.4 ft3min-1
      60Hz: 7.0 m3h-1 / 4.1 ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 5.1 m3h-1 / 3.0 ft3min-1
      60Hz: 6.2 m3h-1 / 3.7 ft3min-1
  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 50 mbar / 38 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV5-*NEW*-Vacuum-Pump-17434
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV8 *NEW* Vacuum Pump

Edwards RV8 *NEW* Vacuum Pump

Cambridge ID #: 17435

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.45 litres
  • Oil capacity max: 0.75 litres
  • Displacement:
      50Hz: 9.7 m3h-1 / 5.7 ft3min-1
      60Hz: 11.7 m3h-1 / 6.9ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 8.5 m3h-1 / 5 ft3min-1
      60Hz: 10 m3h-1 / 5.9 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 38 mbar / 28.5 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV8-*NEW*-Vacuum-Pump-17435
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Savant UVS400 Universal Vacuum System

Savant UVS400 Universal Vacuum System

Cambridge Scientific ID #'s: 6970, 14458

Safely handle and recover solvents with the Thermo Scientific Savant Universal SpeedVac Vacuum System, equipped with an easy to use, wide-mouth glass condensation flask. This single integrated unit combines an oil-free vacuum source and refrigerated vapor trap, and can be connected to any of the concentrators to provide a complete SpeedVac system.

 

Description:

  • Low maintenance, oil-free and corrosion resistant system
  • Wide mouth glass condensation flask with self-sealing cover
  • Small footprint
  • Single stage refrigeration system
  • Efficient operation with all SpeedVac concentrators, gel dryers and other vacuum-dependent equipment
  • Optional post trap (model no. ANT100) may be added to neutralize ammonia or acid
  • Chemical trap (model no. DTK120R) may be added to absorb volatile radioactivity and residual vapor
  • vacuum <10 torr (13.3mbar)
  • Oil-free ETFE diaphragm pump
  • 36 liters/minute displacement on 60Hz; 30 liters/minute on 50Hz models
Learn More
Savant-UVS400-Universal-Vacuum-System-6970
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Buchi V700 Vacuum Pump

Buchi V700 Vacuum Pump

Cambridge Scientific ID #'s: 25643, 25624

Features:

The Buchi V-700 Vacuum Pump is a reliable pump for Buchi evaporator systems, constructed with highly resistant materials for long-lasting durability. The V-700 delivers a pumping volume of 1.8mᶟ/h with a final vacuum just under 10 mbar. The pump can be used individually to create a vacuum or can be expanded to create a complete vacuum system with secondary condenser, controllers, etc. (The V-700 is for use with and included in evaporating systems R-210 and R-215 with chillers.)
This vacuum pump is in excellent condition, and all of our equipment is fully tested to perform at factory specifications before being shipped.

Specifications:

  • Capacity:1.8 m3 /h*

  • Number of Steps (heads):2 (2)

  • Final Vacuum (Absolute):<10mbar

  • Final vacuum with gas ballast:24mbar

  • Connection:GL14

  • Power Consumption:210 watts

  • Electrical Requirements:100-240V 50/60Hz

  • Pump Motor:DC brushless

  • Nominal Speed:Max. 1600 min -1

  • Sound Level:40—52dbA

Learn More
Buchi-V700-Vacuum-Pump-25643
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Thermo Savant VLP120 Vacuum Pump

Thermo Savant VLP120 Vacuum Pump

Cambridge ID #: 13306

Description:

Achieve maximum solute recovery with the Thermo Scientific™ Deep Vacuum Oil Pumps for Vacuum Concentrators, designed to work with all Thermo Scientific™ SpeedVac™ concentrating and freeze drying systems.

Specifications:

  • Oil Capacity: 0.7 L
  • Pump Displacement: 116 L/min. (at 60 Hz); 97 L/min. (at 50 Hz)
  • Ultimate Vacuum Level: 1.5 mtorr/1.95 x10³ mbar
  • Vacuum Inlet Fitting: 12.7 OD
  • Dimensions (D x W x H): 17 x 6 x 9” (420 x 160 x 230 mm)
  • Electrical Requirements: 115 V, 60 Hz
Learn More
Thermo-Savant-VLP120-Vacuum-Pump-13306
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cambridge Scientific 	CSP-8530 *New* -80 Freezer

Cambridge Scientific CSP-8530 *New* -80 Freezer

Cambridge ID #: 25787

Features:

New Cambridge Scientific -80 is equipped with cutting edge COSCOM (Combination Of Single Compressor Operation Mode) technology by two independent compressor mecha-nisms. Combination of VIP(Vacuum Insulation Panel) and insulation by high pressure injection enable maximum insulation as well as lowest energy consumption for keeping your valuable samples with maximum safety. Auto Cascade system with COSCOM technology protects your samples from any risk other than blackout. With low noise and all time monitoring “Blackbox” service, our new -80 shall be a successful companion of your comfortable research. 

Specifications:

Available Capacity (L): 832 liters

Ext. Dimensions (WxDxH mm): 1227 x 985 x 1980

Int. Dimensions (WxDxH mm): 890 x 725 x 1290

Weight(Kg): 410

2” Cryo Boxes: 25 boxes x 24 rack

3” Cryo Boxes: 15 boxes x 24 rack

2” Racks/Freezer: 600 boxes

Temperature: -60℃ ~ -90℃

Insulation: 130 mm Non CFC, foamed in place polyurethane with VIP

Voltage: 220V 60Hz, 230V 50Hz

Acceptable range: 110V(100-120), 220V(208-230), 230V(220-240)

Certification: ISO9001 / ISO14001 / ISO13485 / CE / KGMP / ETL

Refrigeration: 2 x 1.25 HP

Learn More
Cambridge-Scientific-CSP-8530-*New*--80-Freezer-25787
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1379A HPLC Degasser

Agilent 1100 Series - G1379A HPLC Degasser

Cambridge Scientific ID #'s: 25479, 19163, 23204, 24595

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1379A-HPLC-Degasser-25479
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1260 Series - G1311C HPLC Quaternary Pump

Agilent 1260 Series - G1311C HPLC Quaternary Pump

Cambridge ID #: 25081

1260 Infinity - G1311B 

The quaternary pump comprises an optional solvent cabinet, a vacuum degasser

 and a four- channel gradient pump. The four- channel gradient 

pump comprises a high- speed proportioning valve and a pump assembly. 

It provides gradient generation by low pressure mixing. A solvent cabinet 

provides enough space for four one- liter bottles. An active seal wash 

(optional) is available when the quaternary pump is used with 

concentrated buffer solution 

Specifications:  

  • Hydraulic System: Dual piston in series pump with servo-controlled variable stroke drive, 
  • power transmission by gears and ball screws, floating pistons 
  • Setable Flow Range: Set points 0.001 – 10 mL/min, in 0.001 mL/min increments 
  • Flow Range: 0.2 – 10.0 mL/min 
  • Flow Precision: ≤ 0.07 % RSD, or ≤ 0.02 min SD whatever is greater, based on retention time at constant room temperature 
  • Flow Accuracy: ±1 % or 10 µL/min whatever is greater, pumping degassed H2O at 10 MPa (100 bar) 
  • Pressure Operating Range: Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 mL/min, Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 mL/min 
  • Pressure Pulsation: < 2 % amplitude (typically < 1.3 %), or < 0.3 MPa (3 bar), whatever is greater, at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar,147 psi) 
Learn More
Agilent-1260-Series---G1311C-HPLC-Quaternary-Pump-25081
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1379B HPLC Degasser

Agilent 1200 Series - G1379B HPLC Degasser

Cambridge Scientific ID #'s: 22387, 20389, 22622

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1379B-HPLC-Degasser-22387
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1260 Series - G1322A HPLC Degasser

Agilent 1260 Series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 20560, 25654

1260 Infinity - G1322A 

The Agilent 1260 Infinity Standard Degasser G1322A comprises a 4- channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

Specifications: 

  • Maximum Flow Rate: 10 mL/min per channel 
  • Number of Channels: 4 
  • Internal Volume Per ChannelTypically 12 mL per channel 
  • Materials in Contact With Solvent: PTFE, PEEK 
  • pH Range1 - 14 
  • Analog Output (AUX): For pressure monitoring, range 0 – 3 V 
Learn More
Agilent-1260-Series---G1322A-HPLC-Degasser-20560