Specifications:
Features:
The compact and lightweight XRD-384 reagent dispenser accommodates a wide variety of shallow and deep-well microplates including 96, 384 and 1536-well formats.
Designed for the precise dispensing of volumes from 0.5ul to 2000ul, this system will fill a 384-well format microplate in 10 seconds.
Specifications:
Includes Pump and Bottles
Features:
Specifications:
Description:
Accommodates 96 well microplates and 8 well strips. Typical speed is 105 seconds/plate (3 wash cycles, no soak). 75 user identified programs. Wash methods include bottom washing, double aspiration and multi-speed/amplitude shaking. Select 1 to 9 wash cycles. Liquid flow-through pump 50 to 3000 uL. Soak settings: 0 to 999 seconds in 1 second increments. Vacuum pump: 2 gal (8 L)/min (suction efficiency: 1 to 6 uL per well). In sequential mode, washer performs the first programmed step on every row you specify and then executes each succeeding step, row-by-row until finished. In Repeat Strip Mode, the entire program is performed on the first row of wells, then repeated on the next row of wells (Strip mode reduces carryover of highly concentrated samples).
Specifications:
The ELx405 Select is the world’s first deep well microplate washer that aspirates and dispenses into 96- and 384-well plates without requiring specialized manifolds. ANSI/SBS standard height microplates can also be washed, making the ELx405 Select a total solution for all your laboratory’s microplate washing workflows. Wash processes used in cell culture and plasmid DNA preparation are automated with the ELx405 Select – there’s no need for specialized instrumentation. ELx405 Select can also process magnetic and polystyrene bead protocols, making it a versatile plate washer for many laboratories. The ELx405™ Select is automation compatible and its patented Dual-Action™ manifold is particularly useful in cell-based assays. This product is ideal for all standard and deep well microplate washing requirements.
Specification:
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Featuring:
• 96 well microplate washing
Includes:
• Vacuum Pump
• Valve Module
• Reservoir Bottles
• Waste Bottle
• Tubing
• Manual
Features:
HYDRIM L110W G4 washer has a 10 full-size cassette capacity and will allow offices to turnover 2500 thoroughly cleaned instruments in a 10 hour day.
Under the counter stericentre installation with furniture available for specialized set-ups. HIPTM cleaning solution is stored in the unit, no extra storage space required
Time saved using automated washing compared to manual cleaning is approximately 1 hour of labour for every nine procedural set-ups.1
Specifications:
Height, freestanding: 850 mm / 33.5"
Height, built-in: 830 mm / 32.75"
Width: 600 mm / 23.75"
Depth: 600 mm / 23.75"
Depth with door open: 1200 mm / 47"
Weight: 80 kg / 176 lbs.
Running Noise: 60 dB(A)
Hot and cold water connections: 3/4”
Inlet water pressure: 1-10 bar/14.5-145 psi
Incoming hot water temperature: 50-70°C / 122-158°F
Drain: 3/4”
Water softener: 1 kg / 2.2 lbs salt capacity
Drying System: Heater 1 kW
Electrical Connection: 208-240 V 60 Hz 15 A
Equipment pollution degree: Pollution Degree 2
Equipment installation category: Installation category II
Maximum relative humidity: 80% for temp up to 31°C / 88°F
50% for temp up to 40°C / 104°F
Operating temperature range: -5°C to 40°C / 23-104°F
Max. altitude: 2000m / 6561.7 ft.
Mains supply: + / -10% of nominal
Specifications:
Operates in three modes; electric heat, steam heat, or electric and steam heat.
Specifications:
The Tomtec Quadra 96 Liquid Handling System is a simultaneous 96-well Pipettor: strongSix station shuttle for protocol automation, Fully programmable for preset protocols, Small footprint,minimum benchspace, Various Hood Enclosures available, Programmable tip heights for all stations, Provides reproducible SPE protocols, Industry leader in SPE sample preparation strong Vacuum Control Panel:/strong 3 way valve for closed/open/vent mode, Precise regulator sets working vacuum, Dependable gauge verifies working vacuum, Set parameters at site of experiment, Standardize each extraction step, Easily adapts to house or pump vacuum source, Adapts to Quadra96 or manual operation
The Quadra96 Model 320 is a versatile automated workstation. It is a true 96 well high throughput pipettor equipped with 96 disposable tips – 450µl max volume. The 450µL capacity tips, and six station shuttle are suited to a variety of applications including replicate plating, PCR preparation, SPE (Solid Phase Extraction), liquid/liquid extraction, etc. The Quadra 320 is the industries predominate choice for Solid Phase Extraction applications
Six Station Automated Shuttle Automates complete assay protocols Pipette multiple reagents in one pass Custom reservoirs for standards & controls Air Displacement or Positive Displacement Volumes from 1µL to 450µL Cv of 2 - 3% Disposable Tip Assembly Stand alone, using the front panel Windows programming, using Quadra Command softwareIt comes complete with PC loaded with Quara 96 Command software plus original operator's manual and software manual
It measures approximately 64 cm W x 57 D x 74 H. 230 V.