Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Liquid: 76-90 of 199

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Amersham Biosciences GE FRAC-900 FPLC Fraction Collector

Amersham Biosciences GE FRAC-900 FPLC Fraction Collector

Cambridge Scientific ID #'s: 7632, 6707, 5798

Features:

  • Frac-900 designed to work with AKTA series FPLC
  • 95 places rack for 10-18mm tubes
  • Fraction size 0.05 - 100 ml (0.001 ml increments)
  • Time mode 0.01-9.999min, volume mode 0.01-9.999 ml
  • Max flow rate 100 ml/min
  • Peak detection and location capability, programmable collection modes
Learn More
Amersham-Biosciences-GE-FRAC-900-FPLC-Fraction-Collector-7632
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Amersham Biosciences GE Frac-950 FPLC Fraction Collector

Amersham Biosciences GE Frac-950 FPLC Fraction Collector

Cambridge Scientific ID #'s: 13340, 16288, 16150, 13653, 14492

Includes:

  • Manual
  • Vial Holder rack
  • Power Cord

 

Specifications:

  • Maximum flow rate: 100 ml/min
  • pH stability range: 1 to 13, 1 to 14 (<1 day exposure)

Fraction size

  • Volume mode: to 99999.99 ml
  • Time mode: to 99999.99 min

No spillage range for DropSync

  • Microplates: 0 to 1.0 ml/min
  • 12 mm rack: 0 to 1.5 ml/min
  • 18 and 30 mm rack: 0 to 2.0 ml/min

No spillage range for Accumulator

  • All racks: 0 to 100 ml/min
Learn More
Amersham-Biosciences-GE-Frac-950-FPLC-Fraction-Collector-13340
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Amersham Biosciences GE P-500 FPLC PumpImage Coming Soon

Amersham Biosciences GE P-500 FPLC Pump

Cambridge ID #: 7925

Ideal solvent delivery system for general liquid chromatography and other applications where precise and constant flow at pressures from 0–4 MPa (600 psi) is required. The design creates a dependable laboratory instrument for use with a high performance chromatography media and provides complete compatibility with standard separation methods. It is a valuable contribution to any chromatographic application and is an integral part of the FPLC System.

Specifications:

  • Flow Rate Range: 1–499 mL/h
  • Dimensions: 16 L × 8.5 W × 6.5 H (in)
  • Weight: 9 kg

 

Learn More
Amersham-Biosciences-GE-P-500-FPLC-Pump-7925
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Pharmacia Biotech AKTA FPLC FPLC System

Amersham Pharmacia Biotech AKTA FPLC FPLC System

Cambridge ID #: 18011

AKTA FPLC system is a fully automated liquid chromatography system designed for research scale purification of proteins, wherein proteins of various sizes can be readily purified using different kinds of columns.

 

Features:

  • P-920 Pump
  • UPC-900
  • Frac-900 Fraction Collector
  • INV-907 Injection Valve
  • M-925 Mixer: All eluents can be mixed with a high degree of accuracy an reproducibility.
  • Box 900: Storage compartment and Solvent Tray
  • Computer loaded w/ Unicorn Version. 5.31 Software, Monitor Keyboard & Mouse 
  • Manuals
Learn More
Amersham-Pharmacia-Biotech-AKTA-FPLC-FPLC-System-18011
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Antek 8060 HPLC- CLND

Antek 8060 HPLC- CLND

Cambridge ID #: 15242

Includes vacuum pump

 

Antek’s Model 8060 CLND uses Antek’s accurate and precise Pyrochemiluminescent technology to deliver an equimolar response for all nitrogen-containing compounds. The Chemiluminescence method is clean, fast and interference free. This groundbreaking method can determine all bound nitrogen in a variety of matrices.  Methods for characterizing crude products of a synthesis, quantitating target compounds or generating potency measurements may be based on traditional detectors, such as UV.  These methods are often inaccurate and time consuming. Additionally, this type of detector response depends on

chromophores and requires a purified  reference for each compound you investigate.  The Antek 8060 Series provides the solution. Our range of nitrogen-specific HPLC analyzers enables analysts to calculate compound potency using only a single, high purity nitrogen calibration standard.

 

Specifications:

  • Detection: Pyro-chemiluminescence
  • HPLC System Requirements: Operates on any system with an accurate pulse-free pump. Typical mobile phases (non-nitrogenous containing) include water, alcohol, TFA and other modifiers.
  • Flow rate: 10–300 μL/min\
  • Sensitivity: <0.1 nanogram of nitrogen
  • Outputs: 1 mV, 1 V, 10 V
  • Gases:
    • Dry oxygen: 50–200 cc/min 99.75% 4.5 bar (60 psig).
    • Dry carrier (argon or helium): 50–200 cc/min 99.99%, 4.5 bar (60 psig)
  • Dimensions: 15cm x 26cm x 21cm (W x D x H) (6 x 10.23 x 8.27 inches)
  • Weight: 36 kg (80 lbs)
Learn More
Antek-8060-HPLC--CLND-15242
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Applied Biosystems 112A HPLC SystemImage Coming Soon

Applied Biosystems 112A HPLC System

Cambridge ID #: 7188
  • Injection oven which loads samples onto a capillary peptide column for separation and analysis.
  • Learn More
    Applied-Biosystems-112A-HPLC-System-7188
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Applied Biosystems 4800 Maldi TOF MS System

    Applied Biosystems 4800 Maldi TOF MS System

    Cambridge ID #: 10114

    Includes Computer Loaded with 4000 Series Explorer Software Version 3.5.

     

    The 4800 MALDI TOF/TOF Analyzer is a next-generation tandem time-of-flight MS/MS system that gives you all the advantages of MALDI in a flexible, easy-to-use, ultra-high-performance mass spectrometer.

    • OptiBeam™ on-axis laser provides ten times greater sensitivity to identify and quantitate low-abundance proteins in complex biological samples.
    • High-resolution precursor ion selection, enabled by the QuanTIS precursor selector, lets you detect and identify peptides that other systems miss and makes it easier for you to interpret your data by simplifying MS/MS spectra.
    • Ideal solution for high sensitivity putative protein biomarker identification and quantitation.
    • Fully supports LC MALDI workflows, allowing you to mass analyze without the time constraints of LC.
    • Simple experiment setup and fast mass analysis maximizes laboratory productivity.
    • High-energy, information-rich fragmentation patterns unavailable on other instrument platforms enable you to analyze carbohydrates, lipids, and other biological components.

    Identify and Quantitate Putative Protein Biomarkers with Confidence
    The 4800 MALDI TOF/TOF analyzer offers a new level of sensitivity for identifying and quantifying low abundance putative protein biomarkers. Fully compatible with novel iTRAQ™ reagents, the 4800 analyzer provides the most direct path to protein biomarker discovery. An expanded dynamic range enables high confidence identification and quantitation of low-level putative protein biomarkers in complex matrices. Powerful, easy-to-use GPS Explorer™ provides simplified, automated workflows to get you more quickly from discovery to validation.

    The Only MALDI TOF/TOF™ Analyzer with On-Axis Laser Irradiation
    The 4800 Analyzer is the only MALDI TOF/TOF mass spectrometer with on-axis laser irradiation, enabling sensitivity in the attamole range. Proprietary source modeling algorithms enable low ppm mass detection across the MALDI plate.

    Expand Workflows, Increase Throughput
    Get the speed, stability, and reliability you need to expand your current experimental workflows and add statistical significance to your experimental results. Quickly and easily increase throughput using automation features that allow you to rapidly and confidently collect the MS/MS spectra that really matter —and not waste valuable resources acquiring and evaluating those that don't.

    Learn More
    Applied-Biosystems-4800-Maldi-TOF-MS-System-10114
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Applied Biosystems API 3000 LC/MS/MS  System

    Applied Biosystems API 3000 LC/MS/MS System

    Cambridge ID #: 8337

    includes 1 year Service Contract, Installation, and a PM at 6 months

    Method Development and Training also Available

     

    The API 3000 LC/MS/MS System is an enhanced high performance triple quadrupole mass spectrometer with applications in protein and peptide analysis, small molecule analysis in drug metabolism and pharmacokinetic studies, and n-in-one cassette dosing analysis.

     

    Includes:

    • API 3000Mass Spectrometer, MS/MS System
    • Optional Front end HPLC
    • Mass Range: 50-2250da
    • Windows 7 Computer loaded w/ Analyst Software 1.6
    Learn More
    Applied-Biosystems-API-3000-LC-MS-MS--System-8337
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Applied Biosystems Voyager DE Maldi TOF MS System

    Applied Biosystems Voyager DE Maldi TOF MS System

    Cambridge ID #: 9619

    Key Features:

     

    • The ultimate Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) system provides the highest quality data
    • Powerful Voyager Version 5 with Data Explorer software for flexible acquisition and data processing
    • Reflectron provides high mass accuracy and post-source decay (PSD)
    • Fully automated acquisition and processing of data provides higher throughput
    Learn More
    Applied-Biosystems-Voyager-DE-Maldi-TOF-MS-System-9619
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Bio-Rad 2110 HPLC Fraction CollectorImage Coming Soon

    Bio-Rad 2110 HPLC Fraction Collector

    Cambridge Scientific ID #'s: 4737, 3465

    The easy-to-use Model 2110 Fraction Collector provides multiple collection modes for chromatographic separations.

     

    Features:

    • Time or drop collection modes (or volume collection mode when connected to the Model EP-1 Econo Pump, BioLogic LP System, or BioLogic DuoFlow System)
    • Collection of 1 drop (~50 µl) to 9 ml fractions in 80 test tubes or microtubes (with optional adaptor)
    • Small chromatography columns can be mounted to drop-forming arm to minimize dead volume
    • Manual-advance tube changes
    • Coldroom compatibility
    • Small footprint of 24 x 33 cm

    Specifications:

    • Capacity: Eighty 13 x 100 mm glass, polypropylene, or polystyrene test tubes, or 1.5 ml microtubes when using optional micro tube adaptor
    • Collection basis: 1–999 drops in 1 drop increments, 0.05–9.99 min in 0.01 min increments, 10.0–99.9 min in 0.1 min increments
    • Construction: Case and carousel, polypropylene; front panel, hard-coated polycarbonate
    • Drop former: Silicone rubber
    • Waste outlet tube: Polyurethane
    • Operating temperature: 4–40°C
    • Safety: Meets IEC 61010 and CSA 22.2 certification
    • Dimensions (W x D x H): 24 x 33 x 25 cm
    Learn More
    Bio-Rad-2110-HPLC-Fraction-Collector-4737
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Bio-Rad 2128 HPLC Fraction CollectorImage Coming Soon

    Bio-Rad 2128 HPLC Fraction Collector

    Cambridge ID #: 13732

    The Model 2128 Fraction Collector is used for automatic fraction collection in a variety of laboratory applications. It may be used as a stand-alone unit or as part of Bio-Rad’s Econo System and HPLC chromatography instruments.

    Specifications:

    • Time Range: 03 to 99.9 mins
    • Drop Count: 0 to 999 drops
    • Max Flow Rate: 0 mL/min
    • Collection Tube Capacity: 12 mm to 18 mm diameter x 180 mm height
    Learn More
    Bio-Rad-2128-HPLC-Fraction-Collector-13732
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Biotage SP Flash Chromatography System

    Biotage SP Flash Chromatography System

    Cambridge ID #: 17061

    Liquid HPFC system ideal for all research applications.

    Specifications:

     

    • Temperature Range: 15° to 30℃
    • Humidity Range: 20 to 95% RH
    • Atmospheric Pressure: 10 to 15.5 psi
    • Pollution Degree: 2
    • Dimensions: 19” x 19” x 24” in (L x W x H)
    • Fluid Path Materials: 316 stainless steel, Chemraz, PEEK, PFE, Polythene Polypropylene, PTFE, Silica
    • Fraction Volume: 3 to 240 mL (depending on rack size)
    • Max Fraction Volume: 2880 mL (with no rack change)
    • Max Fraction Number: 128 fractions (with no rack change)
    • Flow Rate: 1 to 100 ml/min variable, in 1 mL/min increments
    • Solvent Delivery: 3 mL/stroke
    • Variable Wavelength: 200 nm to 320 nm
    • Fixed Wavelength: 254 nm
    Learn More
    Biotage-SP-Flash-Chromatography-System-17061
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

    Cambridge ID #: 11053

    Specifications:

    • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
    • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
    • Flow range 1 - 5.0 ml/min
    • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
    • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
    • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
    • Compressibility compensation: User-selectable, based on mobile phase compressibility
    • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
    • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
    • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
    • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
    • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Dionex FLM-3300, NANO, 1X2P-10P HPLC DegasserImage Coming Soon

    Dionex FLM-3300, NANO, 1X2P-10P HPLC Degasser

    Cambridge ID #: 10565
  • Flow Manager and Column Compartment. Temperature range: 5°70 °C (max. 15 °C below ambient). Heatup time: From 20 to 50 °C in less than 25 min
  • (at 23 °C ambient temperature, °0.5 °C)
  • Learn More
    Dionex-FLM-3300,-NANO,-1X2P-10P-HPLC-Degasser-10565
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Dionex RI-101 HPLC Refractive Index DetectorImage Coming Soon

    Dionex RI-101 HPLC Refractive Index Detector

    Cambridge ID #: 17922

    Features:

    This detector is ideal for analysis of components with limited or no UV absorption such as alcohols, sugars, saccarides, fatty acids, and polymers. It provides high sensitivity, fast baseline stabilization and excellent reproducibility.

    Specifications:

    • Measuring Method: Deflection type
    • Refractive Index Range:00–1.75°
    • Range:25 to 512 µRIU
    • Linearity: 600 µRIU
    • Noise Level: Less than 2.5 nRIU, response: 1.5 s
    • Autozero: Optical and electronic autozero
    • Flow Cell: 8 µL; 0.05 MPa (7.5 psi) maximum pressure
    • Dead Volume: Less than 600 µL
    • Flow Rate: 10 mL/min (with water)
    • Temperature Control: 30 to 50°C in 1°C steps
    • Response:1, 0.25, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0 s
    • Automated Startup Functions: Purge cycles, equilibration, autozero, baseline drift and noise verification
    • Validation Functions: Noise, temperature, drift, lamp age, lamp voltage, accuracy (determined filling the detector cell with a defined standard solution)
    • Display: Color liquid crystal display, allows real-time baseline monitoring
    • Analog Outputs: Integrator: 0–1 V; Recorder: 0–10 mV
    • Contact Closure Inputs: Auto zero, marker, polarity, purge on/off
    • Contact Closure Outputs: Ready, solvent leak, error
    • Communication: RS-232
    • Power Consumption: 150 VA Max.
    • Dimensions: 260 x 200 x 400 mm (10.1 x 7.8 x 15.6 inches)
    • Weight: 12 kg (27 lbs)
    Learn More
    Dionex-RI-101-HPLC-Refractive-Index-Detector-17922