Agilent 1260 Infinity II Series – G1364F HPLC Fraction Collector

Cambridge Scientific ID: 28327 Category: Tag:

Description

The 1260 Infinity II Analytical-Scale Fraction Collector is optimized for laboratories performing analytical-scale compound purification of nanogram to milligram quantities with typical flow rates between 0.1 and 10 mL/min. The module features the full set of collection modes and is compatible with a wide variety of trigger sources. SBS plates and four different tube sizes with various lengths are supported.

Features&Benefits: 

  • Integration of all standard collection modes and compatibility to multiple trigger sources provides compatibility with existing purification methods
  • Compact, closed design offers up to 216 fractions in vials or 384 fractions in SBS plates within small dimensions to save valuable bench space
  • Integrated delay volume sensor and automated calibration procedure ensure optimized sample recovery
  • Preconfigured tubing kits allow easy setup and provide optimized substance recovery with minimized peak dispersion at any flow rate
  • Module offers clustering functionality for easy enhancement of available fraction capacity to double or triple
  • Rapid vessel-to-vessel movement minimizes substance loss during movement between fraction vessels

Physical Specifications:

  • Weight:13.5 kg (29.8 lbs)
  • Dimensions (height × width × depth): 200 x 345 × 440 mm (8 x 13.5 × 17 inches)
  • Line voltage:100 – 240 V~, ± 10 %
  • Power consumption: 200 VA / 180 W
  • Ambient operating temperature: 4 – 40 °C (41 – 104 °F)
  • Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
  • Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F)1
  • Operating altitude:  Up to 3000 m (9842 ft)
  • Non-operating altitude: Up to 4600 m (15092 ft)

Performance Specifications:

  • Delay Volume (in µL): 
  • Fraction collector inlet to diverter valve: ~50 (typical, depends on length of the tubing)
  • Diverter valve: ~15
  • Diverter valve to needle: ~10
  • Needle: ~4
  • Minimum system flow: Depending on the recommended flowrates of the installed tubing kit
  • Maximum system flow: 10 mL/min
  • Diverter valve: 3/2 valve, with switching time < 100 ms
  • Maximum pressure: 6 bar at the diverter valve during switching
  • Maximum collection volume: 
    • ~20 mL with 30 x 48 mm (OD x L) tube
    • ~30 mL with 30 x 75 mm (OD x L) tube
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Trigger modes: 
    • Time slices
    • Peak (threshold, up- / downslope)
    • Timetable (combination of time intervals and peak)
    • Manual trigger (supported only with Agilent Instant Pilot G4208A)
  • Trigger Sources: 
    • G7115A, 1260 Infinity II DAD
    • G7165A, 1260 Infinity II MWD
    • G7114A, 1260 Infinity II VWD
    • G6120BA, LC/MS Single Quad VL
    • G6130BA, LC/MS Single Quad SL
    • G7121A, 1260 Infinity II FLD
    • G4260B, 1260 Infinity II ELSD
    • G7162A, 1260 Infinity II RID
    • Other detectors can be used but are not supported for fraction collection.
  • Plates/Trays: 
    • 4 x well-plates full tray (MTP)1
    • 2 × well-plates std. tray + 10 funnels with external containers1
    •  (+ 1 half
    • tray)
    • 2 × well-plates std. tray (MTP) + 10 × 2 mL vials1
    •  (+ 1 half tray)
    • 100 x 2 mL in std. tray (+ 1 half tray)1
    • 3 x 40 x 2 mL in half tray1
    • 3 x 40 funnels in half tray
    • 3 x 15 x 6 mL in half tray1
    • Full tray with 40 test tubes (30 mm OD, max. height 48 mm, ~20 mL / tube)
    • Full tray with 60 test tubes (25 mm OD, max. height 48 mm, ~15 mL / tube)
    • Full tray with 126 test tubes (16 mm OD, max. height 48 mm, ~11 mL / tube)
    • Full tray with 215 test tubes (12 mm OD, max. height 48 mm, ~8 mL / tube)
    • Installed trays are automatically detected and identified.
    • In operation mode “Needle into location” installed plates and vials can be
    • detected.
    • Only one type of well-plates can be used at a time in one tray
  • Fraction Containers:
    • 30 x 48 mm (OD x L) tubes, ~20 mL / tube
    • 25 x 48 mm (OD x L) tubes, ~15 mL / tube
    • 16 x 48 mm (OD x L) tubes, ~11 mL / tube
    • 12 x 48 mm (OD x L) tubes, ~8 mL / tube
    • Vials, well plates, capped vials, and well plates with closing mats can be
    • used as recommended by Agilent Technologies
  • Maximum tube height: 75 mm with short needle assembly G1364-87202
  • Instrument Control: 
  • LC and CE Drivers A.02.17 or above
  • Instrument Control Framework (ICF) A.02.04 or above
  • Instant Pilot (G4208A) with firmware B.02.22 or above
  • Lab Advisor B.02.10 or above

 