We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Liquid: 61-75 of 347

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1316A HPLC Column Compartment

Agilent 1100 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 24757, 14782, 24592, 14774, 13993, 14783, 15133, 17963, 13800, 14767, 22475

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Agilent-1100-Series---G1316A-HPLC-Column-Compartment-24757
By clicking below we can further assist you with your inquiry. Inquire 11 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1316A HPLC Column Compartment

Hewlett Packard 1100 Series - G1316A HPLC Column Compartment

Cambridge ID #: 22333

Optional Column Selection Valve

Specifications:

  • Temperature Range: 10° below ambient to 80° C
  • Temperature Stability: ± 0.15°C
  • Temperature Accuracy: ± 0.8°C
  • Column Capacity: Three 30cm columns
  • Warm-up/Cool Down: 5 mins from ambient to 40°C
Learn More
Hewlett-Packard-1100-Series---G1316A-HPLC-Column-Compartment-22333
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Precision Detectors PD2123 HPLC Absorbance Detector

Precision Detectors PD2123 HPLC Absorbance Detector

Cambridge ID #: 13616

Features:

 

PD2100 Series Detector



Learn More
Precision-Detectors-PD2123-HPLC-Absorbance-Detector-13616
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Rainin Pressure Module Pressure ModuleImage Coming Soon

Rainin Pressure Module Pressure Module

Cambridge ID #: 11705

Specifications:

  • Max Pressure: 8700 psi
  • Dimensions (W x D x H): 6-3/8 x 11-1/4 x 5-1/2 inch
Learn More
Rainin-Pressure-Module-Pressure-Module-11705
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Amersham Biosciences GE REC 112 RecorderImage Coming Soon

Amersham Biosciences GE REC 112 Recorder

Cambridge ID #: 11863

Description:

The Amersham Pharmacia Biotech Biotech REC 112 Dual Channel Data Chart Recorder is a versatile and accurate way to track laboratory information.

Learn More
Amersham-Biosciences-GE-REC-112-Recorder-11863
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 22335, 16041, 22114, 17969, 13408, 16314, 16001, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
 Scienion sciFlexarrayer S11 Piezo Electric Dispenser

Scienion sciFlexarrayer S11 Piezo Electric Dispenser

Cambridge ID #: 25122

 Specifications: 

*011-0010 High Precision X, Y, Z Stage

  • The design of the stage enables high-speed operation and ensures accurate sample deposition and reproducible spot allocation. It comprises linear drives for X and Y movements and a spindle drive for Z movements.
  • Positioning Performance:
  • Resolution (adjustable, software controlled): 1 um
  • Accuracy: <‡ 10 um (Absolute Position)
  • Precision: <‡2 um (Repeat Position)
  • The specifications are valid for the following conditions:
  • Temperature range: 18 - 28 °C
  • Temperature stability (environment): ‡ 1 K Machine temperature (after pre warm period: ‡ 1 K
  • Speed: 150 cm/sec
  • Dimensions (l/w/h): 137/58/47 cm; Weight: 135 kg
  • Overall travel (mm): x=1143; y=115
  • Spottable area (mm): x=905; y= 1 13.5

*F011-0020 Piezo Driver Electronics

  • Supports up to 8 piezo dispense capillaries (PDC) and piezo dispense pens (PDP). Each PDC is activated, configured and controlled individually. This includes freely adjustable voltage, pulse width, frequency and number of drops per position. In addition, each PDC has an ultrasonic self-cleaning mode.

*5011-0040 Wash Station

  • Chemically inert wash chamber enables each PDC to be washed separately with aid of ultrasonics. The wash solution is supplied by a high-quality peristaltic pump.

*F011-0050 Dispense Control Station

  • Includes high-resolution optical components, a stroboscope LED and a horizontally mounted CCD camera. The station can assist optimization of the dispense parameters. In combination with Drop Control' and the respective Upgrade to Volume Control' the automated control of the dispense performance during operation will be enabled.

*011-0060 Tray Station

  • Chemically inert PIFE tray with a single 1.8ml chamber. Can be filled with additional sciCLEAN wash solutions.

*F011-0070 200 ul Reaction Vessel Holder

  • Accommodates up to 4 individual 200ul reaction vessels. Can be used as source for single samples or additional wash solutions.

*F011-0080 Environmental Enclosure

  • Lockable transparent hood, fully enclosing the stage.
  • Dimensions (l/w/h): 150/69/55 cm; Weight: 42 kg

*F011-0090 Instrument Control Software

  • The intuitive control software provides a fully automatic workflow.
  • It comprises a flexible scripting interface and visual control of the instrument settings and performance as well as live video image of the dispense control station.
  • The software comes with a library of tasks and runs which ensure the functionality of the device. The included Task Creator allows creation and modification of tasks.

*F011-0100 PC with 17" LCD-monitor.

  • PC system running Windows XP Pro.

*011-0110 CD

  • User Manuals in PDF format
  • Demo and Training Software
  • Enables the simulation of runs for training or process development and the demonstration of software options.

*F011-2080 Liquid Handling Channel

  • Supplies the fluidics for one PDC. Includes a syringe pump, valve, syringe and all related fittings and tubings. Each Liquid Handling Channel is supplied and controlled individually.

*P-2030 PDC 70 Piezo Dispense Capillary

  • S5, 11, SX, DW, S3 (4x manifold)
  • Fixed drop volume between 300-360 pl

*S-6070 PDC Coating Type 2

  • Can enhance performance for spotting of samples containing organic solvents like DMSO, DMF etc.
  • Nozzle No.: 17065, 17188, 17016, 17463, 15641

*F011-9110 Online Target Alignment Suite

  • (Requires microscope with CCD camera) Recommended for multiple complex target geometries (e.g. biosensors, microstructures). Allows the user to write fully customized recognition and alignment routines.
  • Comprises the following software modules:
    • F011-1210 Find Target Array
    • F011-1230 Find Target Reference Points
    • F011-1240 Target Reference Points to Spots

*F011-2040 Source & Target Plate Holder for one 384 well plate, coolable

*F011-2066Vacuum Pump

  • Clean room compatible. Suction capacity 4 m'/h, final pressure 70 mbar, typical noise level 45 BA, ambient temperature range (operation) 10-40°C weight 11 kg. Available for 110/220V, 50/60 Hz.

*F011-2100 Cooling Unit (PC controlled)

  • Provides active cooling of the source plate module and/or the slide holder.
  • Minimum temperature: -20°C. Controlled by Instrument Control Software. (Mandatory for Dew Point Control)

*F011-2110 Humidity Control

  • The package consists of a state-of-the-art humidifier and a humidity and temperature sensor, The humidity inside the provided hood will be regulated at any value 10% above room humidity up to a maximum of 75% (PC controlled).
  • Noncondensing conditions required during operation of the instrument.

*F011-2120 Head camera incl. coaxial illumination

  • Vertically mounted B/W CCD camera for optical control and data acquisition of the targets. The camera is equipped with a coaxial illumination. It is mounted on the dispense head, connected to the PC and supported by the instrument control software.
  • Useful for pre- and post-spotting processes (e.g. detection of structures for automated target recognition). Manual control (Target Position) is included in the price. Other applications on request. The appropriate camera type and the light source depends on the target. If necessary, the camera / light source must be changed. This could lead to additional costs. Other cameras (e.g. color, other magnifications) on request. Resolution (768 × 576 pxl or 6.4 × 4.7 mm)
  • Scienion offers a solution for customer target recognition.

*F011-1020 Drop Control

  • This fool provides automatic recognition of the dispensed drop and enables the control of the dispense performance during operation. It further regulates the speed of the drop, thereby stabilizing the printing process.

*F011-1030 Upgrade to Volume Control

  • In addition to automatic recognition of the dispensed drop, this tool regulates the volume of the drop, ensuring maximum stability of the dispense process and comparability between different runs.

*F011-1040 Dew point control

  • A special software calculates the dew point depending on humidity and temperature in the hood and regulates the temperature of the source plate holder to prevent condensation.

*F011-1250 Online Array QC Software (requires microscope with CCD camera)

  • Imaging and Image analysis software. Image(s) of the target area will be automatically analyzed for roundness of spots, missing spots and positional accuracy of spots. Inter and intra array spot analysis. Graphical and numerical reports.

*F011-1251 Scan Spot Area

  • Moves the camera over the spot area and makes an image either of the entire target or only the spotted fields.
  • Alternatively, locations to be imaged can be defined. Multiple images can be stitched to give a single image.
Learn More
-Scienion-sciFlexarrayer-S11-Piezo-Electric-Dispenser--25122
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters TCM HPLC Column CompartmentImage Coming Soon

Waters TCM HPLC Column Compartment

Cambridge ID #: 7445

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-TCM-HPLC-Column-Compartment-7445
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Temperature Control Module II HPLC Column CompartmentImage Coming Soon

Waters Temperature Control Module II HPLC Column Compartment

Cambridge ID #: 7396

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-Temperature-Control-Module-II-HPLC-Column-Compartment-7396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1322A HPLC Degasser

Agilent 1100 Series - G1322A HPLC Degasser

Cambridge Scientific ID #'s: 25476, 15628, 25474

Specifications:

  • Maximum flow rate: 10 ml/min per channel
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V
Learn More
Agilent-1100-Series---G1322A-HPLC-Degasser-25476
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1323A HPLC Communication Module

Agilent 1100 Series - G1323A HPLC Communication Module

Cambridge Scientific ID #'s: 6836, 16044, 9537

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323A-HPLC-Communication-Module-6836
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1323B HPLC Communication Module

Agilent 1100 Series - G1323B HPLC Communication Module

Cambridge Scientific ID #'s: 16043, 15085

Features:

Install any desired configuration of Agilent 1200 Series modules. The control module software will reflect which modules are present in the LC system and adjust the screens accordingly.

  • Enter parameter settings for every module, perform reset and on/off functions as well as calibration and configuration settings in a self-explanatory and intuitive way.
  • Define automated analyses including methods, timetables, injector programs, method sequences and automated calibration settings using the control module.
  • Protect your method from any inadvertent keyboard changes by setting method protection.
  • Use PC cards to store and transfer methods and sequences between Agilent1200 systems.
  • Monitor all operations and error events using the self-updating logbooks.
  • Use the context-sensitive online information system to get further information on all topics.
  • Use the context-sensitive menu function to have the quickest access on related functions.
  • To help comply with Good Laboratory Practice (GLP) regulations you can select a variety of module tests that will check the performance of the LC system.
  • The early maintenance feedback (EMF) limits can be used for scheduling maintenance work.
  • Display data graphically using the Plot screen where as many as three different signal scan be monitored at the same time.
  • Print information to a PCL3 compatible printer connected to the serial RS232 port of an Agilent 1200 module.

 

Learn More
Agilent-1100-Series---G1323B-HPLC-Communication-Module-16043
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
MicroCal Thermo Vac2 HPLC Degasser

MicroCal Thermo Vac2 HPLC Degasser

Cambridge ID #: 13729

Features:

 

HPLC Degasser



Specifications:

 

 

  • Sample Degassing and thermostat system

 

 

Learn More
MicroCal-Thermo-Vac2-HPLC-Degasser-13729
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex LC Packings UVD-3000 HPLC Detector

Dionex LC Packings UVD-3000 HPLC Detector

Cambridge ID #: 15447

Specifications:


Noise: ±1 × 10–5 AU (254 nm, 2.0 s response time)
Drift: 2× 10–4 AU/h
Response Time: 0.1/0.2/0.5/1/2/5/10 s
Wavelengths: Up to four simultaneously, user-selectable
Wavelength Range and Accuracy: 190–740 nm, ± 2nm
Bandwidth: <8 nm
Flow Cell Volume: Nano LC, 3 nL volume; Capillary LC, 45 nL volume; Micro LC, 180 nL volume
Maximum Cell Pressure: 400 bar (6000 psi)
Lamp: Deuterium
Data Collection Rate: 1–10 Hz
Analog Output: 2×1 V
Dimensions (h × w × d): 16 × 42 ×51 cm (6.3 ×16.3 × 20 in.)
Weight: 10.5 kg (23 lb)

Learn More
Dionex-LC-Packings-UVD-3000-HPLC-Detector-15447
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Millipore Waters 745 Data ModuleImage Coming Soon

Millipore Waters 745 Data Module

Cambridge ID #: 6485

Data Module

Learn More
Millipore-Waters-745-Data-Module-6485
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping