We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Chromatography Liquid: 106-120 of 347

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G1329A HPLC Autosampler

Agilent 1200 Series - G1329A HPLC Autosampler

Cambridge Scientific ID #'s: 24129, 24718, 24432, 24950

Specifications:

  • Autosampler (Chiller Compatible)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range: 1– 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)
  • Replicate injections: 1– 99 from one vial
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 µl
    • Typically < 1 % RSD of peak areas from 1 – 5 µl
  • Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
  • Carryover: Typically < 0.1 %, < 0.05 % with external needle cleaning
  • Sample viscosity range: 2 – 50 cp
  • Replicate injections per vial: 1 – 99
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 40 × 2-ml vials in ½ tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s depending on draw speed and injection volume

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1329A-HPLC-Autosampler-24129
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 21014, 24720, 22330, 23961, 25377, 23159

The Agilent 1200 ALS Thermostat, G1330A controls temperature for either HPLCs or fraction collectors. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/heating module. There it is cooled or heated according to the temperature setting.

Specifications:

  • Weight: 20.7 kg (45.6 lbs)
  • Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)
  • Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection
  • Line Frequency: 50 or 60 Hz, ± 5 %
  • Power consumption Autosampler: 300 VA 
  • ALS Thermostat: 260 VA
Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-21014
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Agilent 1200 Series - G1362A HPLC Refractive Index Detector

Cambridge ID #: 20340

Features:

  • Advanced temperature controlled detector optics ready to use within two hours of installation
  • Automatic zero and automatic purge combined with a recycle valve for automatic solvent recycling allow uninterrupted operation
  • Automatic light intensity control circuit to ensure the optimum performance of the optics
  • Integrated diagnostics for efficient troubleshooting
  • Built-in refractive index calibration
  • Front access to valves and capillaries for easy maintenance
  •  

Specifications:

  • Detection type: Refractive Index
  • Refractive index range: 1.00 – 1.75 RIU, calibrated
  • Measurement range: +/- 600 x 10-6 RIU
  • Optics temperature control: 5 ° C above ambient to 55 ° C
  • Sample cell volume: 8uL
  • Maximum pressure: 5 bar (0.5Mpa)
  • Maximum flow rate: 5mL/minute
  • Valves: Automatic purge and automatic solvent recycle
  • Volumes: Inlet port to sample cell 62uL, inlet port to outlet port 590uL
Learn More
Agilent-1200-Series---G1362A-HPLC-Refractive-Index-Detector-20340
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 24077, 25603

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-24077
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1364C HPLC Fraction Collector

Agilent 1200 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 25481, 25601

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1364C-HPLC-Fraction-Collector-25481
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 25480, 23958

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367C-HPLC-Well-Plate-Autosampler-25480
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1376A HPLC Capillary Pump

Agilent 1200 Series - G1376A HPLC Capillary Pump

Cambridge ID #: 20388

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1376A-HPLC-Capillary-Pump-20388
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367D HPLC AutosamplerImage Coming Soon

Agilent 1200 Series - G1367D HPLC Autosampler

Cambridge ID #: 25378

Description:

The G1367D Agilent 1200 Series High Performance Autosampler SL+ is specifically designed for the Agilent 1200 Series Rapid Resolution LC system for increased analysis speed with uncompromised sensitivity, resolution, precision and lowest carry over. Features increased pressure range (up to 600 bar) enabling the use of today’s column technology (sub-two-micron columns) with the Agilent 1200 Rapid Resolution LC System. Increased robustness by optimized new parts, high speed with lowest carry-over by flow through design, increased sample injection speed for high sample throughput, increased productivity by using overlapped injection mode and flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384-well plates allows you to process up to 768 samples unattended.

 

Features:

Injection range: 0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)

Precision: Typically < 0.25% RSD from 5 – 40 µl, Typically < 0.5% RSD from 2 – 5 µl, Typically < 0.7% RSD from 1 – 2 µl volume

Pressure range: Up to 600 bar (8700 psi)

Sample viscosity: range 0.2 – 5 cp

Sample capacity: 2 × well plates (MTP) + 10 × 2 ml vials 108 x 2-mL vials in2 x 54 vial plate, plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate, plus 10 additional 2 mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate

Injection cycle time: Typically < 17 s

Carry-over: Typically < 0.004%

Learn More
Agilent-1200-Series---G1367D-HPLC-Autosampler-25378
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1379B HPLC Degasser

Agilent 1200 Series - G1379B HPLC Degasser

Cambridge Scientific ID #'s: 22387, 20389, 22622

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1379B-HPLC-Degasser-22387
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G2226A HPLC Nano Pump

Agilent 1200 Series - G2226A HPLC Nano Pump

Cambridge ID #: 12658

This Agilent 1200 Model G2226A ( G 2226A, G 2226 A, G2226 A ) Series Nano (NanoFlow) Pump is in excellent condition!  The Agilent 1200 Series nanoflow pump uses a unique solvent delivery technology optimized for nanoliter-per-minute flows and features EFC (Electronic Flow Control) with active feedback and real time flow adjustment. EFC is the gold standard for robust and reliable nanoflow performance and delivers the precise flow and gradient performance necessary for retention time reproducibility and stable ion generation essential for high sensitivity nanospray MS performance.

Features:

  • Electronic Flow Control (EFC) provides real-time adjustment of the flow rate throughout the analysis for reliable and reproducible results.
  • Micro vacuum degassing with very low internal volume per channel (1 mL) for fast changeover of mobile phase and quick purge.
  • Control from handheld controller for convenient local status monitoring.
  • 2nd generation flow sensors.
  • Application focus: High resolution separations and high sensitivity MS detection. Proteomics is a typical application area for the nanoflow pump.

 

Learn More
Agilent-1200-Series---G2226A-HPLC-Nano-Pump-12658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 series - G2260A HPLC Preparative Autosampler

Agilent 1200 series - G2260A HPLC Preparative Autosampler

Cambridge ID #: 16719

Specifications:

  • Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • 900 µl in 0.1 µl increments (recommended 1 µl increments)
    • Up to 1800 µl with multiple draw (hardware modification required)
    • Up to 5000 µl with multiple draw (hardware modification required)
  • Replicate injections: – 99 from one vial
  • Precision:
    • Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
    • Typically < 1% RSD of peak areas from 2000 – 5000 µl
    • Typically < 3% RSD of peak areas from 1 – 5 µl
  • Minimum sample volume:
    • µl from 5 µl sample in 100 µl microvial
    • 1 µl from 10 µl sample in 300 µl microvial
  • Sample viscosity range: 0.2 – 50 cp
  • Sample capacity:
    • 100 × 2-ml vials in 1 tray
    • 15 × 6-ml vials in ½ tray (Agilent vials only)
  • Injection cycle time: Typically 50 s, depending on draw speed and injection volume
Learn More
Agilent-1200-series---G2260A-HPLC-Preparative-Autosampler-16719
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1220 Infinity - G4288B HPLC System

Agilent 1220 Infinity - G4288B HPLC System

Cambridge ID #: 21857

Features:

This Agilent 1220 Infinity LC - G4288B has a Gradient Pump, Manual injector, Variable wavelength detector configuration.


Specifications:

Weight: 43 kg (94 lbs)
Dimensions (height × width× depth): 640×370×485 mm (25.2×14.6×19.1 inches)
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 240 VA / 210 W / 717 BTU
Ambient operating temperature: 4–55 °C (39–131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)

Learn More
Agilent-1220-Infinity---G4288B-HPLC-System-21857
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity II - G7129A HPLC Multisampler

Agilent 1260 Infinity II - G7129A HPLC Multisampler

Cambridge ID #: 25648

The Agilent 1260 Infinity II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. 

Specifications:

  • Capacity of up to 132 vials (2 mL) or up to 36 vials (6 mL)
  • Reliable injections from 0.1 to 100 µL at up to 600 bar (model G7129A) or up to 800 bar (model G7129C)
  • Injection volume extension up to up to 1,500 µL (G7129A), or up to 1,800 µL (G7129C) for microbore to semipreparative applications
  • Needle flush port enables rinsing the outside surfaces of the needle for lowest carryover
  • Integrated column compartment, available as option or upgrade, holds two columns up to 30 cm length, and provides heating from 5 degrees above ambient to 80 °C for reproducible chromatographic data at optimized resolution
  • Integrated sample thermostat, available as option or upgrade, provides cooling and heating from 4 to 40 °C
  • Low internal volume for minimum contribution to system's total internal volume, which can be even further reduced using bypass mode
  • Overlapped sample runs and injection cycles for increased productivity
  • Customizable injection program for advanced injection sequences or sample preparation prior to injection

 

Learn More
Agilent-1260-Infinity-II---G7129A-HPLC-Multisampler-25648
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity II - G7167A HPLC Multisampler

Agilent 1260 Infinity II - G7167A HPLC Multisampler

Cambridge ID #: 25647

The Agilent 1260 Infinity II G7167A Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Agilent LC stack. The 1260 Infinity II Multisampler is optimized for highest flexibility. The unique dual-needle design enables cycle times to be reduced by overlapping sample runs and injection cycles. The multiwash capability reduces carryover to less than 9 ppm.

 

Learn More
Agilent-1260-Infinity-II---G7167A-HPLC-Multisampler-25647
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G1311B HPLC Quaternary Pump

Agilent 1260 Infinity Series- G1311B HPLC Quaternary Pump

Cambridge ID #: 19976

Features:

This versatile and highly reliable pump offers flow rates up to 10 mL/min and pressures up to 600 bar. It is suited for the use of smaller particle size columns giving higher resolution and faster separations. It maintains virtually pulse-free, well mixed and stable solvent flows. Its dual floating, precise servo-controlled pistons adjust the stroke volume according to your chosen flow rate. Offering access to up to four solvents, the 1260 Infinity II Quaternary Pump provides the greatest flexibility in automated solvent blending. It is recommended for a wide range of research and routine applications (especially in the food, environmental and pharmaceutical sectors) as well as for method development.

Specifications:

  • Higher resolution, faster separations - the maximum pressure of 600 bar allows you to use smaller particle size columns, longer columns and/or higher viscous solvents as an alternative to acetonitrile.
  • Analytical and semi-preparative purifications - the wide flow range (up to 10 mL/min) perfectly supports standard and semi-preparative applications. The perfect choice for 4.6 and 3.0 mm id columns.
  • Quicker experiments - the pump offers convenient access to up to four solvents for isocratic or gradient analysis, which can really speed up method development, preparation of mobile phases and system flushing. 
  • Easy, fast and secure transfer of methods - from conventional to sub-2-micron columns.
  • Integrated degasser
  • Longevity and low operating costs - robust materials (stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE) withstand the most demanding applications and keep your pump functioning for years. Our optional seal wash for high-salt mobile phases keeps maintenance to a minimum and reduces operating costs.
Learn More
Agilent-1260-Infinity-Series--G1311B-HPLC-Quaternary-Pump-19976
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping