Edwards E2M28 *NEW* Vacuum Pump

Edwards E2M28 *NEW* Vacuum Pump

Cambridge ID #: 17439

Features:

The EM range of oil-sealed rotary pumps is renowned for their high ultimate vacuum, rapid pumping speed, quiet operation and the ability to withstand vapour. They are commonly used for laboratory and light industrial applications. It is a freestanding instrument with the drive provided through a flexible coupling by either a single phase or three phase motor.

 

Specifications:

 

  • Power Connector 1-ph: IEC EN 60320 C19
  • Noise: 57 dB(A) at 50 Hz
  • Oil capacity max: 1.5 litres
  • Oil capacity min: 1.2 litres
  • Displacement (swept volume):
               50Hz: 32.2 m3h-1 / 19 ft3min-1
               60Hz: 38.9 m3h-1 / 22.3 ft3min-1
  • Speed (Pneurop 6602):
               50Hz: 27.5 m3h-1 / 16.2 ft3min-1
               60Hz: 33.0 m3h-1 / 19.5 ft3min-1
  • Ultimate vacuum (total pressure)
               without gas ballast: 1 x 10-3 mbar / 7.5 x 10-4 Torr
               with gas ballast: 1.5 x 10-2 mbar / 1.1 x 10-2 Torr
               with Fomblin: 1 x 10-2 mbar / 7.5 x 10-3 Torr
  • Inlet connection: NW25 flange
  • Outlet connection: Nozzle 15mm external Ø removable from 3/4 in BSP tapped hole
  • Max allowed pressure at outlet: 0.5 bar gauge / 7 psig
  • Max inlet pressure for water vapour: 30 mbar / 23 Torr
  • Max water vapour pumping rate: 0.7 kg h-1
  • Operating temperature range: 13 – 40 °C
  • Nominal rotation speed: 1440 / 1720 rpm
  • Motor power 50Hz: 0.75 kW
  • Motor power 60 Hz: 0.90 kW
  • Recommended oil: Ultragrade 19
  • Thermal overload device: prevents overheating (single phase only).
  • The drive is provided through a flexible coupling: by a single‑phase or three‑phase (four pole) motor.
  • The motors: are totally enclosed and are cooled by the motor cooling fan.
  • Full height O ring sealed oil sight glass: for easy checking of oil level and condition.
  • IE3 energy efficient 3 phase motor used with E2M28.

 

 

Learn More
Edwards-E2M28-*NEW*-Vacuum-Pump-17439
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV12 *NEW* Vacuum Pump

Edwards RV12 *NEW* Vacuum Pump

Cambridge ID #: 17436

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.65 litres
  • Oil max: 1 litres
  • Displacement :
      50Hz: 14.2 m3h-1 / 8.4 ft3min-1
      60Hz: 17 m3h-1 / 10 ft3min-1
  • Speed (Pneurop 6602)
      50Hz: 12 m3h-1 / 7.1 ft3min-1
      60Hz: 14.2 m3h-1 / 8.4 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 32 mbar / 24 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 290 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

 

Learn More
Edwards-RV12-*NEW*-Vacuum-Pump-17436
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV3 *NEW* Vacuum Pump

Edwards RV3 *NEW* Vacuum Pump

Cambridge ID #: 17433

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement:

                50Hz: 3.7 m3h-1 / 2.2 ft3min-1

                60Hz: 4.5 m3h-1 / 2.6 ft3min-1

  • Speed (Pneurop 6602):

 

                50Hz: 3.3 m3h-1 / 2 ft3min-1

                60Hz: 3.9 m3h-1 / 2.3 ft3min-1

  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.2 x 10-1 mbar / 9.1 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 80 mbar / 60 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV3-*NEW*-Vacuum-Pump-17433
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV5 *NEW* Vacuum Pump

Edwards RV5 *NEW* Vacuum Pump

Cambridge ID #: 17434

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.42 litres
  • Oil capacity max: 0.7 litres
  • Displacement :
      50Hz: 5.8 m3h-1 / 3.4 ft3min-1
      60Hz: 7.0 m3h-1 / 4.1 ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 5.1 m3h-1 / 3.0 ft3min-1
      60Hz: 6.2 m3h-1 / 3.7 ft3min-1
  • Ultimate pressure: 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
  • Ultimate Pressure with Fomblin: 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 50 mbar / 38 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV5-*NEW*-Vacuum-Pump-17434
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards RV8 *NEW* Vacuum Pump

Edwards RV8 *NEW* Vacuum Pump

Cambridge ID #: 17435

Features:

The RV is a series of oil sealed small rotary vane pumps that deliver great ultimate vacuum pressure, capability to reach high pumping speeds and superior vapour handling features with quiet operation.

 

Specifications:

 

  • Operating temperature range: 12 – 40 °C
  • Noise level: 48 dB(A) at 50 Hz
  • Motor power 50/60Hz: 450 / 550W
  • Power connector 1-ph: IEC EN 60320 C13
  • Nominal rotation speed 50/60Hz: 1500 / 1800 rpm
  • Oil capacity min: 0.45 litres
  • Oil capacity max: 0.75 litres
  • Displacement:
      50Hz: 9.7 m3h-1 / 5.7 ft3min-1
      60Hz: 11.7 m3h-1 / 6.9ft3min-1
  • Speed (Pneurop 6602):
      50Hz: 8.5 m3h-1 / 5 ft3min-1
      60Hz: 10 m3h-1 / 5.9 ft3min-1
  • Ultimate pressure: 2 x 10-3 mbar / 1.5 x 10-3 Torr
  • Ultimate pressure GB I: 3 x 10-2 mbar / 2.3 x 10-2 Torr
  • Ultimate pressure GB II: 6 x 10-2 mbar / 4.6 x 10-2 Torr
  • Ultimate pressure with Fomblin: 2 x 10-2 mbar / 1.5 x 10-2 Torr
  • Max inlet pressure for water vapour: 38 mbar / 28.5 Torr
  • Max water vapour pumping rate – GB I: 60 gh-1
  • Max water vapour pumping rate – GB II: 220 gh-1
  • Max allowed outlet pressure: 0.2 bar gauge / 2.8 psig
  • Max allowed inlet and gas ballast pressure: 0.5 bar gauge / 7 psig
  • Recommended oil: Ultragrade 19
  • Inlet flange: NW25
  • Exhaust flange: NW25
  • High reliability: generous lubrication of moving parts.
  • Safe process and systems: fast acting inlet valve for best in class anti‑suck back protection.
  • Configured to meet your vacuum needs: mode selector and two position gas ballast.
  • No unplanned downtime: designed for easy maintenance.
  • Better work environment: quiet running and intrusive frequencies minimised.
  • Two position gas ballast: allows either 60 g/hr or a class leading 220 g/hr of water vapour to be handled.
  • Universal motor: to cover the widest possible voltage and frequency range from a single variant.
  • Smooth controlled inlet valve: opening by oil pressure to eliminate pressure surges.
  • Rapid closing inlet valve: within 0.4 seconds of pump stopping.

 

Learn More
Edwards-RV8-*NEW*-Vacuum-Pump-17435
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex L/S 7524-40 Peristaltic Pump

Cole Parmer Masterflex L/S 7524-40 Peristaltic Pump

Cambridge ID #: 17311

Masterflex L/S series peristaltic pumps include fixed and variable speeds, providing high accuracy drives for precise flow control and dispensing. Ideal for laboratory, process and field use.

Specifications:

  • Maximum Speed: 1.6 - 100 rpm
  • Maximum Torque Output: 360 oz-in (26 kgcm)
Learn More
Cole-Parmer-Masterflex-L-S-7524-40-Peristaltic-Pump-17311
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex L/S 7550-20 Peristaltic Pump

Cole Parmer Masterflex L/S 7550-20 Peristaltic Pump

Cambridge ID #: 17250

Cole Parmer Masterflex L/S
Masterflex L/S series peristaltic pumps include fixed and variable speeds, providing high accuracy drives for precise flow control and dispensing. Ideal for laboratory, process and field use.

Specifications:

  • Flow Rate: 0.00001 to 3400 mL/min
Learn More
Cole-Parmer-Masterflex-L-S-7550-20-Peristaltic-Pump-17250
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent MS40+ Pumps

Agilent MS40+ Pumps

Cambridge ID #: 17114

Small footprint, high pumping speed, and reduced noise level. Ideal for most laboratory applications.

Specifications:

 

  • Capacity (Oil): 1 Quart
  • Speed: 1,800 RPM
  • Temperature Range: 12 to 40°C
  • Oil Temperature: 60°C
  • Dimensions: 16.4” x 11.6” x  9” in (L x W x H)
  • Motor Rating: 0.75 Kw
  • Pressure: 3.75 x 10-2 Torr
  • Noise Level: ≤ 62 dB (A)
  • Pollution Degree:

 

 

 

 

 

 

Learn More
Agilent-MS40+-Pumps-17114
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
ChemTec Tandem 1081 Pump Control Module

ChemTec Tandem 1081 Pump Control Module

Cambridge Scientific ID #'s: 16642, 16439

The ChemTec provides programmable feed scheduling for chemical reactors, bioreactors and fermenters either by weight or volume. Both linear and exponential feed strategies can be readily implemented. When interfaced with an electronic balance, the ChemTec can also be used to maintain vessel or reactor weight in diafiltration or perfusion applications, it can also act as a pH controller for pH maintenance or simple end point titration. 

Specifications:

  • Pump Output: 0.03 ml/min to 2,250 ml/min
  • Tubing Sizes: #13, 14, 16, 17, 18, and 25
Learn More
ChemTec-Tandem-1081-Pump-Control-Module-16642
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Edwards E2M30 Vacuum Pump

Edwards E2M30 Vacuum Pump

Cambridge Scientific ID #'s: 16470, 13258, 16469, 13257

E2M30 pumps are two-stage, direct drive, sliding vane pumps. The pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

Specifications:

  • Operating Temperature: 13 - 40 °C
  • Storage Temperature: -30 to 70 °C
  • Maximum Ambient Operating Humidity: 90%
  • Maximum Displacement 50/60Hz: 19/23 cfm
  • Maximum Speed 50/60Hz:2/19.4 cfm
  • Motor Rotational Speed 50/60Hz: 1440/1720 rpm
  • Ultimate Vacuum Without Gas Ballast: 7 x 10-5 torr
  • Ultimate Vacuum With Gas Ballast:5 x 10-1 torr
  • Maximum Water Vapor Inlet Pressure: 5 torr
  • Maximum Water Vapor Pumping Rate: 7 kg/h
Learn More
Edwards-E2M30-Vacuum-Pump-16470
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
GAST DOA-P704-AA Vacuum Pump

GAST DOA-P704-AA Vacuum Pump

Cambridge Scientific ID #'s: 16449, 16448, 15792, 16639, 15791

Specifications:

  • Volts: 115
  • Cycle: 60
  • Phase: 1
  • Speed: 60 Hz 1575
  • Thermal Protection: Yes
  • Amps Running Low Volts: 60 Hz 4.2
  • Motor Class: B
Learn More
GAST-DOA-P704-AA-Vacuum-Pump-16449
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Buchi V-500 Pumps

Buchi V-500 Pumps

Cambridge ID #: 16083

This diaphragm vacuum pump provides excellent operating reliability and is suitable for use with the Büchi evaporators. All components that come in contact with solvent vapors are made of highly resistant materials, including PTFE membranes, and glass heads. The Büchi Vac V-500 is a vacuum pump suitable for evacuating laboratory equipment.

Specifications:

  • Suction Volume: 6 cubic meters/hour
  • Final Vacuum: 10 mbar
Learn More
Buchi-V-500-Pumps-16083
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Cole Parmer Masterflex 7520-40 Peristaltic Pump

Cole Parmer Masterflex 7520-40 Peristaltic Pump

Cambridge Scientific ID #'s: 15276, 8674

This economical and easy to use analog drives offer precise speed control, ideal for metering applications. The reversible motor allows for purge tubing before or after pumping fluid in either direction.

Specifications:

  • Speed Range: 6 - 600 rpm
  • Speed Control:+/- 2%
  • Max Flow Rate: 3400 mL/min
  • Minimum Flow Rate:36 mL/min
  • Power:90-130VAC, 1.5A
  • Dimensions of Drive:5 x 7 x 7 in
  • Motor hp:1/10
Learn More
Cole-Parmer-Masterflex-7520-40-Peristaltic-Pump-15276
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Edwards E2M2 Vacuum Pump

Edwards E2M2 Vacuum Pump

Cambridge ID #: 15237

Edwards E2M2 rotary vane pumps have a peak pumping velocity of 1.5 cfm and a ultimate pressure of 7.5 x 10-4 Torr. The E2M2 is a dual stage rotary vane mechanical vacuum pump with a 1 phase or 3 phase electrical supply.  It is reliable and operates quietly at 52 dB(A).It has excellent vapor handling capabilities and can be used in many applications.

Specifications:

  • Nominal Displacement: 2 (cfm)
  • Nominal Displacement: 57 (l/m)
  • Stage: 2
  • Motor HP: 1/3
  • Oil Capacity: .6
  • Weight: 18.2
  • Noise Level: 52
Learn More
Edwards-E2M2-Vacuum-Pump-15237
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Edwards E2M28 Vacuum Pump

Edwards E2M28 Vacuum Pump

Cambridge Scientific ID #'s: 15220, 12174, 16406, 12175, 17184, 13271

The EM range of oil-sealed rotary pumps - renowned for its high ultimate vacuum, rapid pumping speed, quiet operation and ability to handle vapour - has become the industry standard laboratory and light industrial applications. The E2M28 pump is a two-stage, direct drive, sliding vane pump. The pump is oil sealed and designed for reliable, long-term operation in both laboratory and industrial environments.

Specifications:

  • Power Requirements: 110V, 50/60Hz, 750/900W, 8.2A
  • Ultimate Vacuum Without Gas Ballast: 75 micron/millitorr
  • Ultimate Vacuum With Gas Ballast:11 micron/millitorr
  • Dimensions:75 x 23 x 11 in
  • Maximum Water Vapor Inlet Pressure:5 torr
  • Maximum Water Vapor Capacity:700 grams/hour
  • Oil Capacity:3L - 1.5 L
  • Nominal Rotation Speed:1400-1720
  • Weight:100 lbs
Learn More
Edwards-E2M28-Vacuum-Pump-15220
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping