Cambridge Scientific
Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Well Plate Autosampler: 1-6 of 6

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Agilent 1100 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 14763

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications Controller: area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features:  Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:  
    • 1 – 100 μl in 0.1 μl increments
    • Up to 1500 μl with multiple draw (hardware modification required)
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 100 μl,
    • Typically < 1 % RSD from 1 – 5 μl
  • Sample viscosity range:  0.2 – 5 cp
  • Sample capacity:
    • 2 × well-plates (MTP) + 10 × 2 ml vials
    • 100x2ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically < 30 s using following standard conditions:
    • Default draw speed: 200 μl/min
    • Default eject speed: 200 μl/min
    • Injection volume: 5 μl
  • Carry-over Typically:
    • < 0.01 % using the following conditions:
    • Column: 125 x 4 mm Hypersil ODS, 5 μm
    • Mobile phase: Water/Acetonitrile = 80/20
    • Flow rate: 1 ml/min
    • Injection volume: 1 μl caffeine (1 mg/ml), 5 μl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port

 

Learn More
Agilent-1100-Series---G1367A-HPLC-Well-Plate-Autosampler-14763
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Agilent 1100 Series - G1377A HPLC Well Plate Autosampler

Cambridge ID #: 13766

Specifications:

  • GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
  • Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
  • Injection range:
    • – 8 µl in 0.01 µl increments with the small loop capillary
    • – 40 µl in 0.01 µl increments with the extended loop capillary
  • Precision:
    • Typically < 0.5 % RSD of peak areas from 5 – 40 µl,
    • Typically < 1 % RSD from 1 – 5 µl
    • Typically < 3 % RSD from 0.2 – 1 µl
  • Sample viscosity range: 2 – 5 cp
  • Sample capacity:
    • 2× well-plates (MTP) + 10 × 2 ml vials
    • 100 x 2 ml in one tray
    • 40 x 2 ml in half tray
  • Injection cycle time:
    • Typically, < 30 s using following standard conditions:
    • Default draw speed: 4 µl/min
    • Default eject speed: 10 µl/min
    • Injection volume: 0.1 µl
  • Carry-over:
    • Typically < 0.05 % using the following conditions:
    • Column: 150 x 0.5 mm Hypersil ODS, 3 µm
    • Mobile phase: Water/Acetonitrile = 85/15
    • Column Flow rate: 13 µl/min
    • Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover
    • Outside wash of needle before injection: 20 sec with water using flush port
Learn More
Agilent-1100-Series---G1377A-HPLC-Well-Plate-Autosampler-13766
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367A HPLC Well Plate Autosampler

Agilent 1200 Series - G1367A HPLC Well Plate Autosampler

Cambridge ID #: 16313

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367A-HPLC-Well-Plate-Autosampler-16313
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge ID #: 16300

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-16300
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Leap Technologies CTC Analytics HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 11220, 12890, 12872, 12869, 11959, 12661, 13515, 13511, 16550, 13518, 13512, 15896, 13519, 12870, 13516, 13517, 12867, 12868, 13513, 12873, 12660

The Leap technologies CTC PAL HTC Auto sampler for HPLCs offer Precise and Accurate sample Loading, high throughput, flexible analysis while taking up limited bench space.

 

Includes:

  • HTC PAL Autosampler (Width: 534mm Depth: 385mm Height: 648mm)
  • Temperature controlled sample storage 3 drawer
  • XYZ injector/Arm
  • LC Injection valve- 6 port
  • Wash station
  • Gameboy controller
  • Power Supply
  • Manual
Learn More
Leap-Technologies-CTC-Analytics-HPLC-Well-Plate-Autosampler-11220
By clicking below we can further assist you with your inquiry. Inquire 21 In Stock Worldwide Shipping
Thermo Scientific PAL HTC-Accela1-TMO HPLC Well Plate Autosampler

Thermo Scientific PAL HTC-Accela1-TMO HPLC Well Plate Autosampler

Cambridge ID #: 15946

Specifications:

  • Unit Power Supply: (Input) 100-240VAC, 50-60Hz, 4A, (Output) 36VDC, 4.16A
  • Cooler Power Supply: (Input) 100-240VAC, 50-60Hz, 2A, (Output) 24VDC, 4.5A
  • Cooling stack
  • Waste Station
  • Valve
  • Hand Held Controller
Learn More
Thermo-Scientific-PAL-HTC-Accela1-TMO-HPLC-Well-Plate-Autosampler-15946
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping