Memmert HCP105 Humidity Chamber

Cambridge Scientific ID: 28564 Category: Tag:

Description

Active humidity control creates a controlled environment for accelerated life tests and 85/85 tests. HCP 105 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests.

Specifications:

Temperature

  • Working-temperature range: +7 above ambient temperature up to +90°C
  • Setting temperature: +18 to +90°C
  • Setting accuracy temperature: 0.1°C
  • Temperature: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

  • Humidity Control: Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter
  • Setting range active humidity control: 20 to 95 % rh and rh-Off
  • Setting accuracy humidity: 0.5 % rh

Control technology

  • ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
  • Language setting: German, English, Spanish, French, Polish, Czech, Hungarian
  • Adjustable parameters: Temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime
  • Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Function SetpointWAIT: The process time does not start until the set temperature is reached
  • Calibration: Three freely selectable values each, temperature and humidity

Standard equipment

  • Works calibration certificate: Works calibration certificate (measuring point chamber centre) at 60 °C with 75 % rh
  • Door: Additional heated inner glass door
  • Door: Fully insulated stainless steel door with 2-point locking (compression door lock)
  • Entry port: Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, center left
  • Internals: 2 perforated stainless steel shelf/shelves
  • Standard accessories: Water tank including connection hose

Stainless Steel Interior

    • Dimensions: w(A) x h(B) x d(C): 560 x 480 x 400 mm (d less 35 mm for fan)
    • Interior: W.-St. 1.4301 (ASTM 304)
    • Volume: 107 l
    • Max. number of internals: 6
    • Max. loading of chamber: 90 kg
    • Max. loading per internal: 15 kg

Electrical data: 

  • Voltage Electrical load: 230 V, 50/60 Hz approx. 1720 W
  • Voltage Electrical load: 115 V, 50/60 Hz approx. 1720 W

 