Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Thermal Cyclers ranging from Real Time PCR to qPCR, and Gradient Thermal Cyclers to non-Gradient Thermal Cyclers. Some of our popular manufacturers include ABI, MJ-Research, Bio-Rad, Agilent / Stratagene, and Eppendorf.

Bio Rad: 1-15 of 44

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Bio-Rad ALD-1244 Alpha Blocks

Bio-Rad ALD-1244 Alpha Blocks

Cambridge ID #: 11761

Features:

  • Configuration: 48/48-well
  • Dual-block Alpha unit
  • Capacity: 2 x 48 x 0.2 ml tubes
  • Sample Volume: 5–125 µl

 

Learn More
Bio-Rad-ALD-1244-Alpha-Blocks-11761
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad ALS-1296 Alpha Blocks

Bio-Rad ALS-1296 Alpha Blocks

Cambridge ID #: 8135

Features:
• Configuration: 96-Well
• Single-block Alpha unit
• Capacity: 96 x 0.2 ml tubes, one 96-well plate
• Sample Volume: 5–125 µl

Learn More
Bio-Rad-ALS-1296-Alpha-Blocks-8135
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad ALS1296 Alpha Blocks

Bio-Rad ALS1296 Alpha Blocks

Cambridge Scientific ID #'s: 9430, 8609, 16088, 9431, 19290, 19288, 19289, 9396, 19291

Alpha units are interchangeable reaction modules available in a variety of formats to accommodate standard tubes and plates and high-density microplates.

Every thermal cycler in the DNA Engine family (the DNA Engine, DNA Engine Dyad, Dyad Disciple, and DNA Engine Tetrad 2 cyclers) accepts all interchangeable Alpha units. Changing an Alpha unit takes less than 10 seconds, with no tools required. The temperature accuracy specifications of Alpha blocks ensure consistent results experiment-to-experiment and cycler-to-cycler.

 

Features:

  • Single-block Alpha unit
  • Adjustable heated lids set manually; 96-well unit is gradient capable
  • Configuration: 96-well
  • Capacity: 96 x 0.2 ml tubes, one 96-well plate
  • Sample Volume: 5–125 µl
  • Catalog: ALS-1296
Learn More
Bio-Rad-ALS1296-Alpha-Blocks-9430
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Bio-Rad C1000 PCR / Thermal Cyclers

Bio-Rad C1000 PCR / Thermal Cyclers

Cambridge ID #: 20199

Features:

  • Block Configuration: Dual 48 well
  • Gradient Range: 30-100 ͦC
  • Built in gradient feature: accommodates 0.2µl and 0.5µl tubes, strips and plates
  • Maximum Gradient: 25 ͦ C
  • Maximum Ramp Rate: 3.3 ͦ C per second
  • Accuracy: ±0.2°C
  • temperature monitoring which can be controlled by in sample probe, block or instrument algorithm
  • Heated lid Temperature: 0-110 ͦ C
  • Average ramp rate: 3.3 ͦ C/sec
  • Dimensions: 29x 58x39 cm
  • Weight: 17.6 kg

Specifications:

  • Input Power: 100-250 VAC ± 10% 50-60 Hz
  • Environmental Operating temperature: 15-30 ͦ C
  • Environmental Storage temperature: -20-30 ͦ C
  • Environment Humidity: 0-90%, noncondensing
  • Descriptive, Operating Module (WxHxD): 12.2”x 7”x 17” (31x 17.8x43.2 cm)
  • Regulatory Compliance: TUV,CE
Learn More
Bio-Rad-C1000-PCR---Thermal-Cyclers-20199
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad CHEF-DR II Gel Electrophoresis System

Bio-Rad CHEF-DR II Gel Electrophoresis System

Cambridge ID #: 13111

Includes:

  • Cooling Module
  • Control Module
  • Drive Module

 

Drive Module 

  • Dimensions (W x D x H): 43 x 26 x 14 cm
  • Construction: Aluminum chassis
  • Weight: 8 kg (17.2 lb)
  • Maximum voltage:250 V DC
  • Maximum current: 500 mA
  • Electrode potentials:Dynamically regulated (feedback adjustment) +/- 0.5%
  • Input voltage range:
    • 90–132 VAC/47–63 Hz/0.7 A (maximum)
    • 198–264 VAC/47–63 Hz/0.35 A (maximum)
  • Fuses:
    • 5 A Fast Blow for high voltage output (front panel)
    • A Slow-Blow (100/120 V) or
    • 5 A Slow-Blow (220/240 V)

Control Module          

  • Dimensions (W x D x H): 31 x 13.5 x 17 cm
  • Maximum current: 500 mA
  • Allowable voltage gradients:6–6 V/cm, in 0.1 V/cm increments
  • Data entry: Keyboard
  • Power supply: 250 V maximum, to allow maximum gradient of 6 V/cm, continuously adjustable

Cooling Module

  • Chassis: Aluminum
  • Dimensions (W x L x H):23 x 42 x 24 cm
  • Weight: 14 kg (30.1 lb)
  • Compressor:1/12 HP
  • Refrigerant:CFC 12
  • Heat exchanger:Stainless steel
  • Operating range: 5°C–25°C
  • Cooling rate (pre-cool):75°C/min from ambient to 14°C
  • Cooling capacity (input power): 75 W at 14°C
  • Input voltage range       
    • 90–132 VAC/47–63 Hz/4 A
    • 198–264 VAC/47–63 Hz/2 A
  • Fuses   
  • 3 A Slow-Blow (100/120 V) or
  • 0 A Slow-Blow (220/240 V)
Learn More
Bio-Rad-CHEF-DR-II-Gel-Electrophoresis-System-13111
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Chemidoc XRS Gel Imaging System

Bio-Rad Chemidoc XRS Gel Imaging System

Cambridge Scientific ID #'s: 14876, 17686

Includes:

  • Cabinet & Camera
  • Computer With Software
  • Manual

 

The Bio-Rad ChemiDoc XRS System is Bio-Rad’s most advanced imaging system. The system is able to image chemiluminescent, fluorescent and colorimetric samples and comes complete with a compact darkroom, transilluminator and supercooled high resolution 1.44 megapixel CCD camera. The entire system is controlled by the provided Quantity One 1-D analysis software with additional controls on the compact darkroom to control focus, aperture and zoom. Consequently, the ChemiDoc XRS system is extremely flexible and can be used for imaging a diverse range of applications such as Western blotting, DNA/RNA gel electrophoresis, 2-D gel electrophoresis, densitometry, etc. The system is able to detect HRP and AP chemiluminescence, ethidium bromide, SYBR Green, green fluorescent protein, silver stain and Coomasie brilliant blue staining to name but a few that are frequently used with the above applications. The system features flat fielding technology which allows for superior uniformity and quantification. Flat-fielding is a technique that corrects for pixel-to-pixel variations by dividing the gain variations out of an image, thus flattening the relative response for each pixel.

Operation of the system is very simple. The gel or membrane is placed on the transilluminator, which is set into a drawer which can be moved in and out of the darkroom, facilitating placement of the gel or membrane. Once the gel or membrane is placed, it and the transilluminator are returned to the darkroom and the door closed. With the Epi-illumination switched on, the aperture, zoom and focus are adjusted using the touchpad on the darkroom and viewed on the computer monitor until the desired position, size and focus of the gel are achieved. To acquire the image, the appropriate light source for the gel or membrane is selected and the software is used to select an integration time. Using the Quantity One software, the image is frozen when a satisfactory image is acquired. The Quantity One 1-D image analysis software aids the user in obtaining the best images possible from the gel or membrane. The software is user-friendly and equipped with built-in quick guides and wizards to facilitate the optimization of images and printouts. The software is compatible with both Microsoft Windows and Macintosh platforms. The Quantity One 1-D software is used for analysis of 1-D electrophoresis gels, Western blotting membranes, Coomassie-stained SDS-PAGE gels, etc. whereas the PDQuest 2-D analysis software is also available and is intended to be used for comparative analysis where many 2-D gels are analyzed at once.

 

Specifications:

  • CCD Resolution (HxV): 1,392 x 1,040µm
  • Pixel density: 65,536 gray levels
  • Imaging area: 25 x 26 cm
  • Camera cooling temperature: -50°C
  • Camera cooling system: Peltier
  • Dynamic range: 4 orders of magnitude
  • Motorized zoom lens: C-mount, f/1.2, 12-75 mm
  • Illumination modes: Epi-white, trans-UV (302 nm), and white
Learn More
Bio-Rad-Chemidoc-XRS-Gel-Imaging-System-14876
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad DNA Tetrad 2 / PTC-240 PCR / Thermal Cyclers

Bio-Rad DNA Tetrad 2 / PTC-240 PCR / Thermal Cyclers

Cambridge Scientific ID #'s: 19287, 8607

The DNA Engine Tetrad 2 thermal cycler is a four-bay thermal cycler ideal for high-throughput research and production environments. The Tetrad 2 thermal cycler is an updated version of the cycler which powered the Human Genome Project.

Features:

  • High-throughput cycling in a compact footprint
  • Intuitive graphical interface for rapid input of protocols and easy file management
  • Interchangeable Alpha units with adjustable heated lids that accommodate a wide range of reaction vessels and sealing options
  • Excellent temperature accuracy and uniformity for consistent results
  • Real-time displays of block and lid temperatures provide quality assurance that the thermal cycler is performing as directed
  • Software features, such as error tracking logs, run tracking files, and file management tools, offer valuable information for high-throughput runs

Alpha unit modules are available in several formats, including:

  • Gradient-enabled 96-well unit that allows simultaneous incubation at 8 different temperatures to optimize reactions in a single run
  • Dual 48/48-well unit that allows 2 independent experiments to run simultaneously
  • High-throughput 384-well unit
Learn More
Bio-Rad-DNA-Tetrad-2---PTC-240-PCR---Thermal-Cyclers-19287
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad FIGE Mapper Gel Electrophoresis

Bio-Rad FIGE Mapper Gel Electrophoresis

Cambridge ID #: 13116

Features:

 

Fragment Size: 100bp-10Mb




Learn More
Bio-Rad-FIGE-Mapper-Gel-Electrophoresis-13116
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Gene Pulser II Electroporation System

Bio-Rad Gene Pulser II Electroporation System

Cambridge ID #: 6645

Description:

The new Gene Pulser II system is a completely redesigned electroporation system, which offers improved performance, flexibility, sample protection, and safety. The Gene Pulser II system uses the Pulse Trac waveform delivery system to generate the most accurate exponential decay pulses possible for optimal cell transformation within an electroporation cuvette. The Pulse Trac delivery system accurately calculates the time constant of each pulse based on what is actually delivered to the sample.

Specifications:

  • Input voltage: 100/120 V RMS, 50/60 Hz
  • Input current: 15 amp RMS
  • Maximum output voltage and current: 2,500 V at 125 amp peak (normal load); limited to 1,500 A during arc.
  • Output waveform: Pulse Trac exponential decay with RC time constant dependent on sample and capacitor selected
  • Output voltage adjustment: 50–2,500 V range (depending on the capacitor) with 10 V adjustment precision for the high voltage range and 2 V for the low-voltage range (50–500 V).
  • Ambient operating environment: Temperature 0–35°C
  • Humidity: 0–95% without condensation
  • Regulatory: Passes requirements of IEC 1010. In addition, the system passes requirements for FCC, Class A.
  • Dimensions: 34 x 31 x 19 cm
  • Weight: 10.41 kg
Learn More
Bio-Rad-Gene-Pulser-II-Electroporation-System-6645
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Gene Pulser II System Electroporation System

Bio-Rad Gene Pulser II System Electroporation System

Cambridge ID #: 20135

Includes

  • Gene Pulser II
  • Capacitance Extender Plus
  • Pulse Controller Plus
Learn More
Bio-Rad-Gene-Pulser-II-System-Electroporation-System-20135
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Genepulser Electroporation System

Bio-Rad Genepulser Electroporation System

Cambridge ID #: 20052

Includes

  • Gene Pulser II
  • Pulse Controller Plus
  • Capacitance Extender Plus
  • Gene Pulser II Shocking Chamber
  • 25-pin and 9-pin Interconnect Cables
  • Cuvette holder
Learn More
Bio-Rad-Genepulser-Electroporation-System-20052
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad GS-800 Densitometer

Bio-Rad GS-800 Densitometer

Cambridge Scientific ID #'s: 20509, 14335, 14336

The GS-800 calibrated densitometer offers superior accuracy, sensitivity, and data reproducibility. It automatically self-calibrates the optical density to optimize detection.Unlike laser densitometer systems, the GS-800 calibrated densitometer has both transmittance and true reflectance capabilities that allow accurate scans of both transparent and opaque samples. The advantage of true reflectance scanning is accurate detection and analysis of molecules on the surface of membranes, rather than molecules distributed throughout the membrane matrix.

Specifications:

  • Wavelength: 400-750 nm
  • Absorbance Range:0 - 3 OD (transmissive), 0 - 2 OD (reflective)
  • Scanning Area: 29 x 40 cm (transmissive), 30 x 40 cm (reflective)
  • Sampling Rate:800 x 1600 dpi
  • Pixel Density:12 bit
  • Dimensions: 3 x 62.6 x 19.3 cm
  • Weight:8 kg
Learn More
Bio-Rad-GS-800-Densitometer-20509
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Bio-Rad iCycler PCR / Thermal Cyclers

Bio-Rad iCycler PCR / Thermal Cyclers

Cambridge Scientific ID #'s: 7539, 13864, 5479

384 Well Block

The optical module houses the excitation system and the detection system. The Excitation system consists of a fan-cooled 50 watt tungsten halogen lamp a heat filter (infrared absorbing glass) a 6 position filter wheel fitted with optical filters and opaque filter "blanks" and dual mirror arrangement that allows simultaneous illumination of the entire sample plate.

 

The excitation system of the BioRad iCycler PCR Thermal Cycler is physically located on the right front corner of the optical module with the lamp shining from right to left perpendicular to the instrument axis. Light originates at the lamp passes through the heat filter and a selected color filter and is then reflected onto the plate in the thermal cycler by a set of mirrors. This light source excites the fluorescent molecules in the wells.

 

Features:

  • Unique modular design for maximum flexibility and sensitivity
  • Methods that enable a choice of PCR chemistry
  • Outstanding thermal performance from the iCycler thermal cycler
  • Gradient functionality for rapid assay optimization
  • Easy-to-use software for efficient accurate data analysis
  • Compatibility with outstanding PCR supermixes that provide optimum performance in real-time PCR assays
Learn More
Bio-Rad-iCycler-PCR---Thermal-Cyclers-7539
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Bio-Rad iCycler MyIQ PCR / Thermal Cyclers

Bio-Rad iCycler MyIQ PCR / Thermal Cyclers

Cambridge Scientific ID #'s: 20132, 19599, 19602
20422
Learn More
Bio-Rad-iCycler-MyIQ-PCR---Thermal-Cyclers-20132
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Bio-Rad IQ5 Real-Time qPCR System

Bio-Rad IQ5 Real-Time qPCR System

Cambridge ID #: 19250

Features:

 

The IQ5 system offers an affordable option for the detection of common green fluorescent dyes such as FAM and SYBR Green I. It offers five-target analysis capabilities for multiple PCR with a variety of detection chemistries.

 

Specifications:

  • Temperature: 4 -100 C
  • Accuracy: +- 0.3 C of programmed target
  • Uniformity: +- 0.4 C well-to-well
  • Fluorescence excitation range: 515-700 nm
  • Sensitivity: One copy of 1L-1B in human genomic DNA
  • Compatible dyes: FAM,SYBR GREEN I, HEX, TAMRA,TEXAS RED,Cy5
  • Dimensions:29.2x58.4x38.7(11.5x23x15.2’’_
  • Weight: 17.6kg (39lb)
Learn More
Bio-Rad-IQ5-Real-Time-qPCR-System-19250
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping