Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Fume Hood: 16-30 of 33

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Labconco 37200-00 Laminar Flow Hood

Labconco 37200-00 Laminar Flow Hood

Cambridge Scientific ID #'s: 19770, 11454

2 ft Purifier Vertical Clean Bench

Specifications:

  • Nominal downflow velocity of 45-65 fpm
  • Aerodynamic air foil
  • Supply HEPA filter, 99.99% efficient on particles 0.3 micron
  • ISO Class 5 air (formerly Class 100 per Federal Standard 209E)
  • Disposable prefilter
  • Variable speed built-in blower with motorized impeller and solid state control rated for 10 amps
  • Intrinsically-sound, negative pressure design
  • Minihelic pressure gauge
  • Air diffuser
  • UV-resistant, glacier white and gray, powder-coated aluminum and steel construction
  • UV-opaque and resistant 1/4" thick tempered safety glass sash and sides
  • Fluorescent lamp
  • Light and blower switches
  • 9.4" high sash opening
  • Ergonomic 10° angled and hinged sash that pivots upward, locks to a loading height of 20" and has wiping seals to promote ISO Class 5 conditions
  • Two utility ports with iris openings and plugs
  • ETL Listing (115 volt, 60 Hz models)
  • One year warranty on parts and service

 

Learn More
Labconco-37200-00-Laminar-Flow-Hood-19770
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Flow Sciences 4720 Laminar Flow HoodImage Coming Soon

Flow Sciences 4720 Laminar Flow Hood

Cambridge ID #: 17222

Description:

An FS4700 series fan box consists of a motorized impeller installed in a housing with a variable speed controller. The housing is designed to fit over a HEPA filter on the inlet side and is equipped on the discharge side with a single outlet.

Learn More
Flow-Sciences-4720-Laminar-Flow-Hood-17222
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Germfree BZ3-RX Laminar Flow HoodImage Coming Soon

Germfree BZ3-RX Laminar Flow Hood

Cambridge ID #: 4550

Features:

Purair® FLOW series laminar flow hoods are designed to protect the work surface, products and materials from particulate contamination. Room air passes through a HEPA filter then uniformly by laminar flow through the cabinet interior to protect the work from unfiltered air. The airflow is oriented to exhaust airborne particulate introduced by the user.

Specifications:

  • Filters: 36 x 36 x 6
  • Motor: 3/4 Hp, 1450 rpm , 7.7 Amp
    Double Motor # 7024-1351 (permanent split capacitor)
  • Capacitor: 7.5 MFD
  • Circuit breaker: 15 Amp
Learn More
Germfree-BZ3-RX-Laminar-Flow-Hood-4550
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Microzone Clean Cell HLF-2-4 Laminar Flow HoodImage Coming Soon

Microzone Clean Cell HLF-2-4 Laminar Flow Hood

Cambridge ID #: 6451

Description:

These cost-effective vertical laminar flow and horizontal laminar flow workstations feature the Clean-Ceil fan filter module, which utilizes a HEPA filter that is 99.99% efficient for all particles >=0.3µm. The workstations may be used as either benchtop or console units. They incorporate a modular design approach that allows the user to customize a workstation by choosing the optional accessories necessary to meet individual requirements. The workstations come complete with aluminum support frame, clear Plexiglas side panels, 40% efficient ASHRAE-rated prefilter, white plastic laminate back panel (vertical model only, filter is on top), or clear Plexiglas top panel (horizontal model only, filter is on back).

Specifications:

  • Dimensions (D x H x W): 21” x 22” x 46”
  • Electrical: 115 V, 60 Hz
  • Air velocity: 90 ±20 fpm
Learn More
Microzone-Clean-Cell-HLF-2-4-Laminar-Flow-Hood-6451
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Biospherix Medical Closed Isolator System Laminar Flow Hood

Biospherix Medical Closed Isolator System Laminar Flow Hood

Cambridge ID #: 19843

Features:

  • The Bioshperix is a completely closed isolotar system with incubators that is capable to producing an ISO 5 environment.
  • The complete incubator system has 4 modules each with a length of 57 ¼” by 30 5/8” for a total length of 332.37” and depth of 119.47”.
  • The systems also includes 2, 36” by 24” Laminar flow hoods at each end of the Isolator for introducing materials intop the closed environment.
  • Each module is spearated from each other by means of a buffer box.
  • One module of the isolator has 2 enclosed incubators capable fo growing and processing cells. Each incubator has outside dimensions of 21.25” W × 33”D × 50.5” H.
  • The incubator system also includes a leak testing panel to test for leaks in the system to demostrate compliance with FDA requirements.
  • The unit also has 2 chillers to cool the chambers to 4°C. Two separate set of chillers are included one to cool the working surface and other to cool the enviromnet if so desired.
Learn More
Biospherix-Medical-Closed-Isolator-System-Laminar-Flow-Hood-19843
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Baker EG-6252 Laminar Flow Hood

Baker EG-6252 Laminar Flow Hood

Cambridge Scientific ID #'s: 20828, 20829, 20827

The Baker EdgeGARD clean bench is ideal for IV admixture preparation, drug compounding, plant cell culture, media preparation, pharmaceutical procedures, electronic assembly, and limited experimental research.

Features:

  • Length: Six Feet
  • Class 100 cleanliness
  • Laminar air flow across work surface - 100 FPM
  • Console Style
  • Stainless Steel Interior
  • Fluorescent Light
  • High velocity return air slots for maximum product protection
  • HEPA filter captures 0.3 micrometer particulates - in good operating condition
  • Interior Dimensions: 70.5 x 22 x 34 1/8 inches

Caution:

A clean bench is not designed to protect personnel or the environment from potentially harmful agents. The adequacy of this product for the user's personal safety, as with any clean bench, should be determined by an industrial hygienist or safety officer

 

Learn More
Baker-EG-6252-Laminar-Flow-Hood-20828
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Esco LHS-8CS-F9  Laminar Flow Hood

Esco LHS-8CS-F9 Laminar Flow Hood

Cambridge Scientific ID #'s: 19169, 19168, 16695, 16696

Specifications:

  • Stainless Steel Side Walls
  • Energy Efficient ECM blower
  • 115VAC, 60 Hz
  • Simple Switches & Minihelic Gauge
  • 8ft Wide
Learn More
Esco-LHS-8CS-F9-Laminar-Flow-Hood-19169
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Nuaire NU-301-436 Laminar Flow Hood

Nuaire NU-301-436 Laminar Flow Hood

Cambridge ID #: 20660

Features:

NuAire Horizontal Laminar Flow Clean Workstations utilize the newest technologies in laminar airflow design, materials and manufacturing processes. The clean workstation can be used where clean airflow per ISO 14644-1 is required for the preparation of injectable drugs, IV solutions, tissue culture, optics, microelectronics, etc. The clean bench should not be used for any work that involves biological agents assigned a level of Risk 1 through 4 as classified by the Centers for Disease Control (CDC), Atlanta, Georgia, since the horizontal flow offers no personnel protection against these agents. The clean bench should only be used to protect the product from contamination. A significant number of design innovations give the NuAire Laminar flow equipment superior performance qualities in airflow, lighting, noise levels and vibration.

Specifications:

  • Cabinet Width (ft): 4

  • Height (in): 36

  • Filter Weight(lbs): 350

Learn More
Nuaire-NU-301-436-Laminar-Flow-Hood-20660
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Bio-Rad Universal Hood Gel Imaging System

Bio-Rad Universal Hood Gel Imaging System

Cambridge Scientific ID #'s: 20491, 7152
"

Features:

 

The Biorad Universal Hood II Gel Doc is an easy-to-use, high-performance system that captures images in real time, allowing you to more accurately position and focus on your sample. The Gel Doc system combines a compact darkroom, UV-transilluminator workstation, CCD camera, motorized zoom lens, and user-friendly Quantity One software to document and quantitate gels stained with ethidium bromide and other fluorophores. The iris, zoom, and focus of the lens can be manipulated either onscreen within Quantity One software or by the instrument control panel. With Biorad's intuitive software, images acquired with the Gel Doc can be rapidly optimized, annotated, analyzed, and printed.




Specifications:

 

  • Maximum sample size: 28 x 36 cm
  • Maximum image area: 25 x 26 cm
  • Excitation source: Trans UV 302, 254, 365 nm & White, Epi-White light
  • Illumination control: 3 modes (trans-UV, trans white, epi-white)
  • Detector: CCD
  • CCD resolution (H x V): 768 x 494 RS-170  752 x 582 CCIR
  • Pixel size in microns (H x V): 8.4 x 9.8
  • Filter holder: 2 positions (1 Emmision Filter, 1 Chemi)
  • Emission filters: 1 included (amber), 4 optional
  • Dynamic range: 1.8 Orders
  • Pixel density (gray levels): 8 bit (256 gray levels)
  • Dynamic flat fielding: No
"
Learn More
Bio-Rad-Universal-Hood-Gel-Imaging-System-20491
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Bio-Rad Universal Hood II Gel Documentation System

Bio-Rad Universal Hood II Gel Documentation System

Cambridge ID #: 20100

Includes:

  • Cabinet & Camera
  • Computer With Software
  • Manual

 

The Bio-Rad ChemiDoc XRS System is Bio-Rad’s most advanced imaging system. The system is able to image chemiluminescent, fluorescent and colorimetric samples and comes complete with a compact darkroom, transilluminator and supercooled high resolution 1.44 megapixel CCD camera. The entire system is controlled by the provided Quantity One 1-D analysis software with additional controls on the compact darkroom to control focus, aperture and zoom. Consequently, the ChemiDoc XRS system is extremely flexible and can be used for imaging a diverse range of applications such as Western blotting, DNA/RNA gel electrophoresis, 2-D gel electrophoresis, densitometry, etc. The system is able to detect HRP and AP chemiluminescence, ethidium bromide, SYBR Green, green fluorescent protein, silver stain and Coomasie brilliant blue staining to name but a few that are frequently used with the above applications. The system features flat fielding technology which allows for superior uniformity and quantification. Flat-fielding is a technique that corrects for pixel-to-pixel variations by dividing the gain variations out of an image, thus flattening the relative response for each pixel.

Operation of the system is very simple. The gel or membrane is placed on the transilluminator, which is set into a drawer which can be moved in and out of the darkroom, facilitating placement of the gel or membrane. Once the gel or membrane is placed, it and the transilluminator are returned to the darkroom and the door closed. With the Epi-illumination switched on, the aperture, zoom and focus are adjusted using the touchpad on the darkroom and viewed on the computer monitor until the desired position, size and focus of the gel are achieved. To acquire the image, the appropriate light source for the gel or membrane is selected and the software is used to select an integration time. Using the Quantity One software, the image is frozen when a satisfactory image is acquired. The Quantity One 1-D image analysis software aids the user in obtaining the best images possible from the gel or membrane. The software is user-friendly and equipped with built-in quick guides and wizards to facilitate the optimization of images and printouts. The software is compatible with both Microsoft Windows and Macintosh platforms. The Quantity One 1-D software is used for analysis of 1-D electrophoresis gels, Western blotting membranes, Coomassie-stained SDS-PAGE gels, etc. whereas the PDQuest 2-D analysis software is also available and is intended to be used for comparative analysis where many 2-D gels are analyzed at once.

 

Specifications:

  • CCD Resolution (HxV): 1,392 x 1,040µm
  • Pixel density: 65,536 gray levels
  • Imaging area: 25 x 26 cm
  • Camera cooling temperature: -50°C
  • Camera cooling system: Peltier
  • Dynamic range: 4 orders of magnitude
  • Motorized zoom lens: C-mount, f/1.2, 12-75 mm
  • Illumination modes: Epi-white, trans-UV (302 nm), and white
Learn More
Bio-Rad-Universal-Hood-II-Gel-Documentation-System-20100
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Qiagen  QIAgility PCR / Thermal Cyclers

Qiagen QIAgility PCR / Thermal Cyclers

Cambridge ID #: 20576

Features:

The QIAgility is a compact benchtop instrument that enables rapid, high-precision setup of PCR experiments with ready-to-use software for ease and convenience. The software provides step-by-step guidance for worktable setup and automatic calculation of all mixes, eliminating the need to program pipetting steps. Just select the kit and cycler, define your targets and start the run. For added flexibility the QIAgility is operated via a laptop computer.

 

Specifications:

  • CommunicationsUSB and RS232

  • Conductive Filtered Tips50 µl and 200 µl Conductive Filtered Tips for liquid-level sensing

  • Consumables (supplied): 10 racks of 50 µl Conductive Filtered Tips (960); 10 racks of 200 µl Conductive Filtered Tips (960); 25 x 5 ml tubes; 100 x 0.2 µl PCR tubes; 3 Tip Disposal Boxes

  • Dimensions Height: 45 cm (18 in.), instrument lid closed; Height: 86 cm (34 in.), instrument lid open; Width: 54 cm (21 in.); Depth: 63 cm (25 in.), without cables

  • Electrical: 100–240 V AC, 250 VA, 50–60 Hz

  • HEPA filter: Preinstalled dual-cartridge 3M Air-Mate HEPA (High Efficiency Particulate Air) filter system provides positive pressure clean air within the closed hood.

  • Humidity: Operating humidity: 40–70%

  • Liquid-level sensing: Minimum detection volume (10 µl in 200 µl PCR tubes). Only functional in combination with QIAGEN Conductive Filtered Tips.

  • Notebook (supplied): QIAgility comes with a notebook computer for added flexibility.

  • Pipetting head: Single channel

  • Place of operation: For indoor use only

  • Pollution level: 2

  • Precision: CV <1%, 5–200 µl (dry-well transfer) CV <5%, 2–5 µl (wet-well transfer) CV <10%, 1 µl

  • Software: Supplied with unlimited user license. Free upgrades by Web download.

  • Table capacity: 6 x SBS positions (127.76 x 85.48 mm) for adapters and Tip Rack Holders 1 x Master Mix Block 1x Reagent Block

  • TemperatureOperating temperature, 15–30 °C (59–86°F)

  • Tip disposal: All used tips ejected externally — no waste accumulation on the worktable

  • Tip volume: 1–200 µl

Learn More
Qiagen-QIAgility-PCR---Thermal-Cyclers-20576
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364B HPLC Fraction Collector

Agilent 1100 Series - G1364B HPLC Fraction Collector

Cambridge ID #: 18542

Features:

 

  • G1364B Fraction Collector, preparative scale, designed for flow rates up to 100 ml / min. and for the use with vials, deep well plates and test tubes up to 100 mm height
  • For Preparative Scale Applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364B-HPLC-Fraction-Collector-18542
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping