Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Spectrometers / Spectrophotometers ranging from Spectrofluorometer, Fluorescence, Atomic Absorption (AA), ICP, to UV / Vis / NIR Spectrometers and Microplate. Some of our popular manufacturers include Beckman, Perkin Elmer, HP, Hitachi, Varian and Bio-Tek. We have one of the largest inventories of Mass Spectrometers available. We also offer service contracts, installation and training. Browse our inventory of used mass spec products below.

High Performance Digital Nmr Spectrometer: 151-165 of 999

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
VWR 89032-216 Water Bath

VWR 89032-216 Water Bath

Cambridge ID #: 22983
  • VWR 89032-210 2L Digital Water Bath, Microprocessor Temperature Controller with LED Display, stainless steel tank, heats to 99.9 celsius, 115V. All of our equipment will be fully tested to perform at factory specifications before being shipped.
  • Learn More
    VWR-89032-216-Water-Bath-22983
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR 89404-476 Stereo/Dissecting Microscope

    VWR 89404-476 Stereo/Dissecting Microscope

    Cambridge ID #: 22183
  • High performance Stereo Microscope is ideally suited for life science, industrial and pharmaceutical inspection, electronic assembly, and bonding operations.
  • Trinocular stereo microscope head
  • Widefield eyepieces
  • Transmitted illumination
  • Learn More
    VWR-89404-476-Stereo-Dissecting-Microscope-22183
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Auto-Logic II 918TS CO2 Manifold

    Auto-Logic II 918TS CO2 Manifold

    Cambridge ID #: 21416

    Simple and intuitive, the AUTO-LOGIC II gives customers the best changeover system to suit their current operations and future expanded requirements. Truly automatic and hassle free. It has digital pressure readouts for inlet pressures and outlet delivery pressures, built-in alarms, and dry contacts to operate external equipment, such as remote alarms or an auto-dialer.

    Specifications:

     

    • Inlet Pressure: 3,000 PSIG
    • Delivery Pressure: 25-200 PSIG
    • Material: Brass or Stainless Steel
    • System: Housed in a NEMA 4x enclosure
    Learn More
    Auto-Logic-II-918TS-CO2-Manifold-21416
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR 945302 Mini Vortexer Vortexer

    VWR 945302 Mini Vortexer Vortexer

    Cambridge ID #: 21256

    Features:

    The VWR 945302 Fixed Speed Mini Vortex Mixer Cat No. 12620-838 is designed for vigorously vortexing samples in a wide variety of applications. Use with flasks, beakers, tubes, and microwell plates the Fixed Speed Mini Vortex Mixer has the capability of high speed mixing of samples at 3200rpm.

    Specifications:

    • Max speed: 3200 rpm
    • Dimensions: 4" W x 6" D x 4" H (12 x 17 x 12 cm)
    • Weight: 11 lbs (5 kg)
    • Electrical: 120V, 50/60Hz, 75W
    Learn More
    VWR-945302-Mini-Vortexer-Vortexer-21256
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR 949035 Dry Bath Incubator

    VWR 949035 Dry Bath Incubator

    Cambridge Scientific ID #'s: 5432, 14719

    Features:

    This VWR dry bath/incubator is a multi-purpose unit ideal for incubation and activation of cultures, enzyme reactions, blood urea nitrogen determinations, immunoassays, melting/boiling points, and a variety of other laboratory procedures. These high wattage, constant-temperature block heaters are economical and versatile. Requires minimum bench space and features convenient front-mounted temperature adjustment knobs providing high and low temperature control. Accepts separate interchangeable modular blocks (can be purchased separately), which accommodate various sample enclosures such as vials, microplates, PCR strips, and a wide variety of tubes. Each block contains a thermometer well, and features close tube-and-block contact for maximum heat retention.

    Specifications:

    Temperature Range: 5° above ambient to 150°C

    Temperature Stability: ±2°C

    Temperature Uniformity: ±5°C

    Learn More
    VWR-949035-Dry-Bath-Incubator-5432
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    VWR 949310 Dry Bath Incubator

    VWR 949310 Dry Bath Incubator

    Cambridge ID #: 22979
  • Multi-purpose units are ideal for incubation and activation of cultures, enzyme reactions, blood urea nitrogen determinations, immunoassays, melting/boiling points, and a variey of other laboratory procedures. These high wattage, constant-temperature block heaters are economical and versatile. Each unit requires minimum bench space and features convenient front-mounted temperature adjustment knobs providing high and low temperature control.
  • Each model accepts separate interchangeable modular blocks, which accommodate various sample enclosures such as vials, microplates, PCR strips, and a wide variety of tubes. Each block contains a thermometer well, and features close tube-and-block contact for maximum heat retention.
  • All units offer two separate temperature adjustment knobs providing reproducible low temperature and high temperature control. Low range knob adjusts from ambient to 100°C and high range knob adjusts from 75 to 150°C.
  • Dry block heaters include a built-in support rod holder with locking knob that accepts the optional support rod and clamp kit. This accessory is ideal for use with thermometers or temperature probes.
  • Learn More
    VWR-949310-Dry-Bath-Incubator-22979
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Perkin Elmer 9600 PCR / Thermal Cyclers

    Perkin Elmer 9600 PCR / Thermal Cyclers

    Cambridge ID #: 6302

    Description:

    • Reproducibility Of Cycle Times
    • Uniformity Of PCR Yields For Samples
    • Thin-Walled MicroAmp Reaction Tubes Allowing Efficient Heat
    • Transfer and Improving Equilibration Times
    • High Speed of Heating and Cooling
    • Heated Cover Assuring That Tubes Fit Tightly In The Wells
    • Oil-Free Operation

    Specifications:

    • Dimensions: 30.5 x 52 x 61 cm
    • Weight: 40.5 kg
    • Input: 120 VAC, 60 Hz
    • Display: 40 Character Blue Luminescent Display
    • Temperature Range: 4°C to 99.9°C
    Learn More
    Perkin-Elmer-9600-PCR---Thermal-Cyclers-6302
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Fisher Scientific 97-970-1 Undercounter Refrigerator

    Fisher Scientific 97-970-1 Undercounter Refrigerator

    Cambridge ID #: 19502

    Features:

     

    It is made to meet the demanding requirements for scientific and laboratory research purposes. Its advanced engineer incorporates the latest in various features like cabinet, refrigeration, temperature. Provides energy efficient, convenient, safe and reliable performance for optimal storage temperature environments necessary for a wide range of life science, pharmacy, biological, medical, clinical, and industrial applications.

     

    Specifications:

     

    • Interior (D x W x H): 15 x 18 x 28.5in.
    • Exterior (L x W x H): 29.75 x 21 x 33.5in.
    • Temperature Range: -12 to-20C
    • Electrical Requirements: 115V60Hz
    • Weight: 84 lb.
    Learn More
    Fisher-Scientific-97-970-1-Undercounter-Refrigerator-19502
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    VWR 980001 Orbital Shaker

    VWR 980001 Orbital Shaker

    Cambridge Scientific ID #'s: 21335, 23210

    Features:

    VWR Digital Orbital Shaker 

    Specifications:

    • Speed Range: 25 to 500 RPM
    • Speed Accuracy: ±2 RPM
    • Orbit: 19 mm (0.75 in)
    • Timer: 1 to 999 minutes
    • Electrical Requirements: 115V, 50/60Hz, 500W
    Learn More
    VWR-980001-Orbital-Shaker-21335
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Advanced Instruments A2O Osmometer

    Advanced Instruments A2O Osmometer

    Cambridge ID #: 22464

    A fully automated, multi-sample osmometer that sets the new benchmark for analytical performance, ease of use, and true walkaway operation

    Specifications:

    • Sample Test Volume: 100 µL
    • Aspirated Sample Volume: 150 µL
    • Sample Capacity: 20-sample carousel
    • Test Time: Less than 3 minutes
    • Sample Throughput: Can process 20 samples in less than 1 hour
    • Units: mOsm/kg H2O
    • Calibrated Range: Low: 0 to 2000 mOsm/kg H2O; Full: 0 to 4000 mOsm/kg H2O
    • Resolution: 1 mOsm/kg H2O
    • Calibration: 3-point calibration for low range, 4-point for full range
    • Communications: Onboard printer, 10/100Mbps Ethernet, 4 USB 1.0/1.1/2.0, integrated bar code scanner 
    • Accuracy*: 0 to 400 mOsm: mean value ≤2 mOsm/ kg H2O from nominal value 400 to 4000 mOsm: mean value ≤0.5% from nominal value
    • Precision*(within run): Standard deviation ±2 mOsm/kg H2O between 0 and 400 mOsm; standard deviation ± 0.5% of value between 400 and 4000 mOsm
    • Drift*: Less than 1 mOsm/kg H2O per month 
    • Temperature Effect**: Recalibration recommended for ambient temperature changes of 5°C (9°F) or greater
    • Storage Temperature: -40°C to +45°C (-40°F to +113°F)
    • Sample Viscosity: Up to 20 mPa•s (20 cP), higher viscosities may affect pipettor accuracy
    • Pipettor Accuracy: <1%
    • Electrical Voltage: 100-240 V AC (50-60 Hz)
    • Power Consumption: 375 W
    • Dimensions(D x W x H): 20.5” x 23.6” x 22.8” , (52 cm x 60 cm x 58 cm)
    • Net Weight: 68 lb (31 kg)

    * Performance at Reference Conditions — 20°C to 25°C (68°F to 77°F); 40% to 60% relative humidity; tolerances of reference or calibration solutions excluded

    ** Operating Conditions — 18°C to 35°C (64°F to 95°F); 5% to 80% relative humidity (noncondensing)

    Learn More
    Advanced-Instruments-A2O-Osmometer-22464
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

    Persee A3AFG *NEW* Atomic Absorption Spectrophotometer

    Cambridge ID #: 21357

    Features:

    The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

    Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

    The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

    The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

    â—† Easy to use, complete software control

    â—† Integrated safety precautions for user protection

    â—† Flexible configuration for a wide array of industrial apps

    â—† Time-saving high speed analysis

     

    Specifications:

    Spectrometer System

    • Model:Flame AA System-A3F, Graphite AA System-A3G, 

      Combined Flame and Graphite Furnace AA System-A3FG

    • Wavelength range: 190-900 nm
    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
    • Modulation: Square wave pulse
    • Modulation frequency:
      • 100 hz self reversal (SR) background
      • 400 hz Deuterium Arc (D2) background

    Monochromator 

    • Grating: 1800 grooves/mm diffraction grating
    • Blazed: wavelength 250 nm
    • Focus: 300 nm
    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
    • Scan mode: Automatic
    • Photometric type: Single beam
    • Wavelength accuracy: ±0.15 nm
    • Wavelength resolution: 0.2 nm±0.02 nm
    • Wavelength reproducibility: <0.05 nm
    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
    • Baseline stability: 0.005 A/30 min
    • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

    Graphite Furnace Analysis

    • Graphite head: Transversally heated
    • Temperature range: Ambient-2650 ℃
    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
    • Feedback : Voltage and optical temperature control feedback
    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
    • Detection limit: Cd<0.004 ng/ml
    • Repeatability:
      Cu<2.0 % , Cd<2.0 %
    • Graphite tubes: Pyrolytically coated with platform
    • Sample size: Up to 20μl
    • Graphite cooling: Water circulator available
    Learn More
    Persee-A3AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21357
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Persee A3F *NEW* Atomic Absorption Spectrophotometer

    Persee A3F *NEW* Atomic Absorption Spectrophotometer

    Cambridge ID #: 21355

    Features:

    The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

    Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

    The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

    The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

    â—† Easy to use, complete software control

    â—† Integrated safety precautions for user protection

    â—† Flexible configuration for a wide array of industrial apps

    â—† Time-saving high speed analysis

     

    Specifications:

    Spectrometer System

    • Model:Flame AA System-A3F, Graphite AA System-A3G, 

      Combined Flame and Graphite Furnace AA System-A3FG

    • Wavelength range: 190-900 nm
    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
    • Modulation: Square wave pulse
    • Modulation frequency:
      • 100 hz self reversal (SR) background
      • 400 hz Deuterium Arc (D2) background

    Monochromator 

    • Grating: 1800 grooves/mm diffraction grating
    • Blazed: wavelength 250 nm
    • Focus: 300 nm
    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
    • Scan mode: Automatic
    • Photometric type: Single beam
    • Wavelength accuracy: ±0.15 nm
    • Wavelength resolution: 0.2 nm±0.02 nm
    • Wavelength reproducibility: <0.05 nm
    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
    • Baseline stability: 0.005 A/30 min
    • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

    Graphite Furnace Analysis

    • Graphite head: Transversally heated
    • Temperature range: Ambient-2650 ℃
    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
    • Feedback : Voltage and optical temperature control feedback
    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
    • Detection limit: Cd<0.004 ng/ml
    • Repeatability:
      Cu<2.0 % , Cd<2.0 %
    • Graphite tubes: Pyrolytically coated with platform
    • Sample size: Up to 20μl
    • Graphite cooling: Water circulator available
    Learn More
    Persee-A3F-*NEW*-Atomic-Absorption-Spectrophotometer-21355
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Persee A3G *NEW* Atomic Absorption Spectrophotometer

    Persee A3G *NEW* Atomic Absorption Spectrophotometer

    Cambridge ID #: 21356

    Features:

    The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications. 

    Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. 

    The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. 

    The flame and graphite furnace can be changed over by a simple selection in versatile AA Win Pro software.

    â—† Easy to use, complete software control

    â—† Integrated safety precautions for user protection

    â—† Flexible configuration for a wide array of industrial apps

    â—† Time-saving high speed analysis

     

    Specifications:

    Spectrometer System

    • Model:Flame AA System-A3F, Graphite AA System-A3G, 

      Combined Flame and Graphite Furnace AA System-A3FG

    • Wavelength range: 190-900 nm
    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
    • Modulation: Square wave pulse
    • Modulation frequency:
      • 100 hz self reversal (SR) background
      • 400 hz Deuterium Arc (D2) background

    Monochromator 

    • Grating: 1800 grooves/mm diffraction grating
    • Blazed: wavelength 250 nm
    • Focus: 300 nm
    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm
    • Scan mode: Automatic
    • Photometric type: Single beam
    • Wavelength accuracy: ±0.15 nm
    • Wavelength resolution: 0.2 nm±0.02 nm
    • Wavelength reproducibility: <0.05 nm
    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm
    • Baseline stability: 0.005 A/30 min
    • Stray light: ≤0.12 %T (220 nm NaI, 340 nm NaNO2)

    Graphite Furnace Analysis

    • Graphite head: Transversally heated
    • Temperature range: Ambient-2650 ℃
    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning
    • Feedback : Voltage and optical temperature control feedback
    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs
    • Detection limit: Cd<0.004 ng/ml
    • Repeatability:
      Cu<2.0 % , Cd<2.0 %
    • Graphite tubes: Pyrolytically coated with platform
    • Sample size: Up to 20μl
    • Graphite cooling: Water circulator available
    Learn More
    Persee-A3G-*NEW*-Atomic-Absorption-Spectrophotometer-21356
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

    Persee AA990AFG *NEW* Atomic Absorption Spectrophotometer

    Cambridge ID #: 21354

    Features:

     

    The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

    AA990F-Flame atomizer only.

    AA990G-Graphite furnace atomizer only. 

    AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

    Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

    â—† Easy-to-use automation software 

    â—† Integrated safety precautions for user protection

    â—† Precision accuracy with integrated correction system 

    â—† Life cycle value, best choice for less than 8 elements of analysis

     

    Specifications:

    • Wavelength range: 190-900 nm

    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

    • Modulation: Square wave pulse

    • Modulation frequency :

      100 Hz self reversal (SR) background,

      400 Hz Deuterium Arc (D2) background

    • Monochromator

    • Grating: 1800 grooves/mm diffraction grating

    • Blazed wavelength: 250 nm

    • Focus: 300 nm

    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

    • Scan mode: Automatic

    • Photometric type: Single beam

    • Wavelength accuracy: ±0.15 nm

    • Wavelength resolution: 0.2 nm±0.02 nm

    • Wavelength reproducibility: <0.05 nm

    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

    • Baseline stability: 0.005 A/30 min

    • Background correction:
      Deuterium Arc (D2) 1.0 Abs,

      Self Reversal (SR) 3.0 Abs

       

      Flame Analysis

    • Flame type: Air/acetylene

    • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

    • Characteristic Concentration: Cu<0.02 μg/ml

    • Detection limit: Cu<0.004 μg/ml
      Repeatability: Cu<0.7 %

    • Burner head: Titanium Alloy

       

    • Nebulizer:
      High–efficiency glass,

      acid proof available as an option

      Pre-mix chamber: Corrosion resistant

    • Atomizer selection:

      Manual (AA990F)
      Automatic changeover (AA990FG)

    • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


      Graphite Furnace Analysis

    • Graphite head: Transversally heated

    • Temperature range: Ambient-2650 ℃

    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

    • Feedback: Voltage and optical temperature control feedback

    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

    Learn More
    Persee-AA990AFG-*NEW*-Atomic-Absorption-Spectrophotometer-21354
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Persee AA990F *NEW* Atomic Absorption Spectrophotometer

    Persee AA990F *NEW* Atomic Absorption Spectrophotometer

    Cambridge ID #: 21352

    Features:

     

    The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

    AA990F-Flame atomizer only.

    AA990G-Graphite furnace atomizer only. 

    AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

    Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

    â—† Easy-to-use automation software 

    â—† Integrated safety precautions for user protection

    â—† Precision accuracy with integrated correction system 

    â—† Life cycle value, best choice for less than 8 elements of analysis

     

    Specifications:

    • Wavelength range: 190-900 nm

    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

    • Modulation: Square wave pulse

    • Modulation frequency :

      100 Hz self reversal (SR) background,

      400 Hz Deuterium Arc (D2) background

    • Monochromator

    • Grating: 1800 grooves/mm diffraction grating

    • Blazed wavelength: 250 nm

    • Focus: 300 nm

    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

    • Scan mode: Automatic

    • Photometric type: Single beam

    • Wavelength accuracy: ±0.15 nm

    • Wavelength resolution: 0.2 nm±0.02 nm

    • Wavelength reproducibility: <0.05 nm

    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

    • Baseline stability: 0.005 A/30 min

    • Background correction:
      Deuterium Arc (D2) 1.0 Abs,

      Self Reversal (SR) 3.0 Abs

       

      Flame Analysis

    • Flame type: Air/acetylene

    • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

    • Characteristic Concentration: Cu<0.02 μg/ml

    • Detection limit: Cu<0.004 μg/ml
      Repeatability: Cu<0.7 %

    • Burner head: Titanium Alloy

       

    • Nebulizer:
      High–efficiency glass,

      acid proof available as an option

      Pre-mix chamber: Corrosion resistant

    • Atomizer selection:

      Manual (AA990F)
      Automatic changeover (AA990FG)

    • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


      Graphite Furnace Analysis

    • Graphite head: Transversally heated

    • Temperature range: Ambient-2650 ℃

    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

    • Feedback: Voltage and optical temperature control feedback

    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

    Features:

     

    The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements. Due to its high sensitivity and excellent performance the instrument can be used for a wide range of applications. The versatile instrument is available in three configurations:

    AA990F-Flame atomizer only.

    AA990G-Graphite furnace atomizer only. 

    AA990FG-Combined with flame and graphite furnace atomizer switch aromatically. 

    Common Applications include: Agricultural, Environmental, Petrochemical, Clinical.

    â—† Easy-to-use automation software 

    â—† Integrated safety precautions for user protection

    â—† Precision accuracy with integrated correction system 

    â—† Life cycle value, best choice for less than 8 elements of analysis

     

    Specifications:

    • Wavelength range: 190-900 nm

    • Light source: Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

    • Modulation: Square wave pulse

    • Modulation frequency :

      100 Hz self reversal (SR) background,

      400 Hz Deuterium Arc (D2) background

    • Monochromator

    • Grating: 1800 grooves/mm diffraction grating

    • Blazed wavelength: 250 nm

    • Focus: 300 nm

    • Bandwidth: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

    • Scan mode: Automatic

    • Photometric type: Single beam

    • Wavelength accuracy: ±0.15 nm

    • Wavelength resolution: 0.2 nm±0.02 nm

    • Wavelength reproducibility: <0.05 nm

    • Spectral bandwidth: 0.5, 1.0, 2.0, 5.0 nm

    • Baseline stability: 0.005 A/30 min

    • Background correction:
      Deuterium Arc (D2) 1.0 Abs,

      Self Reversal (SR) 3.0 Abs

       

      Flame Analysis

    • Flame type: Air/acetylene

    • Sensitivity (Cu): 2 μg/ml Absorption>0.280 Abs

    • Characteristic Concentration: Cu<0.02 μg/ml

    • Detection limit: Cu<0.004 μg/ml
      Repeatability: Cu<0.7 %

    • Burner head: Titanium Alloy

       

    • Nebulizer:
      High–efficiency glass,

      acid proof available as an option

      Pre-mix chamber: Corrosion resistant

    • Atomizer selection:

      Manual (AA990F)
      Automatic changeover (AA990FG)

    • Safety features: Burner switch, flame sensor, gas leak sensor, low gas pressure sensor, drain trap sensor, power loss protection


      Graphite Furnace Analysis

    • Graphite head: Transversally heated

    • Temperature range: Ambient-2650 ℃

    • Heating program: Up to 10 steps. Drying, Ashing, Atomization, Cleaning 

    • Feedback: Voltage and optical temperature control feedback

    • Sensitivity (Cu): 50 ng/m Absorption>0.40 Abs

    Learn More
    Persee-AA990F-*NEW*-Atomic-Absorption-Spectrophotometer-21352
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping