We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Column Compartment: 16-30 of 168

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment

Dionex Ultimate 3000 TCC-3000 HPLC Column Compartment

Cambridge ID #: 17923

Specifications:

  • Temperature range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature accuracy: ±0.5 °C
  • Temperature stability: ±0.1 °C Temperature precision: ±0.1 °C
  • Column capacity: Up to 6 columns, max. 30 cm length
  • Heatup time: Typically 15 minutes 20 °C to 50 °C Cooldown time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Learn More
Dionex-Ultimate-3000-TCC-3000-HPLC-Column-Compartment-17923
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment

Dionex Ultimate 3000 TCC-3000SD HPLC Column Compartment

Cambridge Scientific ID #'s: 20020, 17920

Specification:

 

  • Temperature Range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature Accuracy: ±0.5 °C
  • Temperature Stability: ±0.1 °C
  • Temperature Precision: ±0.1 °C
  • Column Capacity: Up to 6 columns, max. 30 cm length
  • Heat-up Time: Typically 15 minutes 20 °C to 50 °C
  • Cooldown Time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
  • Switching valves: 1 or 2 thermostatted valves (2-position, 6-port, 2-position, 10-port, or 6-position, 7-port)

 

  • Watted parts

 

    • Stainless steel (1.4571, 316L), PEEK; Waste line: PTFE
    • Column switching valve (stainless steel): Vespel and DuraLife
    • Column switching valve (biocompatible): PEEK
    • Column switching valve (6-position, 7-port): Titanium
  • Safety features: Humidity sensor and gas sensor. Temperature control and temperature sensors

 

  • User input/display

 

    • LCD-indicating system parameters
    • Standby button
    • 3 LEDs for status monitoring (Power, Connected, Status)
    • 4 function keys for operation during initial installation and maintenance
  • GLP features: Electronic identification system for 4 columns. In Chameleon: Full support of automatic equipment qualification (AutoQ) and System System Wellness monitoring. All system parameters are recorded in the Chromeleon Audit Trail.
  • Power requirements: 100 - 120 V, 60 Hz; 200 - 240 V, 50 Hz, max. 150 VA
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 17 x 42 x 51 cm (6.7 x 16.5x 20 in)  
  • Weight: 13.2 kg (29.0 lbs)
Learn More
Dionex-Ultimate-3000-TCC-3000SD-HPLC-Column-Compartment-20020
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment

Dionex Ultimate 3000 TCC-3200 HPLC Column Compartment

Cambridge ID #: 18418

Specification:

 

  • Temperature Range: 5 °C to 85 °C (max. 18 °C below ambient)
  • Temperature Accuracy: ±0.5 °C
  • Temperature Stability: ±0.1 °C
  • Temperature Precision: ±0.1 °C
  • Column Capacity: Up to 6 columns, max. 30 cm length
  • Heat-up Time: Typically 15 minutes 20 °C to 50 °C
  • Cooldown Time: Typically 18 minutes 50 °C to 20 °C
  • Control: All functions software controlled via USB
  • I/O interfaces: 2 digital inputs, 2 programmable relay outputs
  • Switching valves: 1 or 2 thermostatted valves (2-position, 6-port, 2-position, 10-port, or 6-position, 7-port)

 

  • Watted parts

 

    • Stainless steel (1.4571, 316L), PEEK; Waste line: PTFE
    • Column switching valve (stainless steel): Vespel and DuraLife
    • Column switching valve (biocompatible): PEEK
    • Column switching valve (6-position, 7-port): Titanium
  • Safety features: Humidity sensor and gas sensor. Temperature control and temperature sensors

 

  • User input/display

 

    • LCD-indicating system parameters
    • Standby button
    • 3 LEDs for status monitoring (Power, Connected, Status)
    • 4 function keys for operation during initial installation and maintenance
  • GLP features: Electronic identification system for 4 columns. In Chameleon: Full support of automatic equipment qualification (AutoQ) and System System Wellness monitoring. All system parameters are recorded in the Chromeleon Audit Trail.
  • Power requirements: 100 - 120 V, 60 Hz; 200 - 240 V, 50 Hz, max. 150 VA
  • Environmental conditions: Indoor use only; 10 to 35°C (50 to 95°F) operating temperature range; 80% relative humidity (non-condensing); Overvoltage category 2; Pollution degree 2.
  • Dimensions (H x W x D): 17 x 42 x 51 cm (6.7 x 16.5x 20 in)  
  • Weight: 13.2 kg (29.0 lbs)
Learn More
Dionex-Ultimate-3000-TCC-3200-HPLC-Column-Compartment-18418
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma Ultimate TCC-3000RS HPLC Column Compartment

Thermo Forma Ultimate TCC-3000RS HPLC Column Compartment

Cambridge ID #: 14871

Operate at temperatures up to 110°C with no compromise in precision or accuracy. The Thermo Scientific Dionex UltiMate TCC-3000RS Rapid Separation Thermostatted Column Compartment enables the use of high column temperatures for ultrafast and conventional liquid chromatography (LC) applications to reduce system back pressures and run times. Dispersion-reduced precolumn heating and postcolumn cooling technology ensures optimal separation, run time, and detection under challenging conditions. These low-volume cooling and heating components can be easily exchanged to optimally match column flow and mobile phase requirements.

Specifications:

  • Temperature Range:5°C - 110°C
  • Temperature Accuracy:+/- 0.5°C
  • Recommended Eluent Preheater Volume:2 uL
  • Cool Down Time:15 min
  • Maximum Column Length: 30 cm
  • Column Capacity:12
  • Weight: 9 kg
  • Power Requirements:150V
  • Pressure Capacity: 125 MPa
Learn More
Thermo-Forma-Ultimate-TCC-3000RS-HPLC-Column-Compartment-14871
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters WAT038040 HPLC Column CompartmentImage Coming Soon

Waters WAT038040 HPLC Column Compartment

Cambridge ID #: 12902

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-WAT038040-HPLC-Column-Compartment-12902
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters WAT270852 HPLC Column Compartment

Waters WAT270852 HPLC Column Compartment

Cambridge Scientific ID #'s: 16972, 11731, 14607, 13888, 16627, 13099, 13856, 13098, 13721, 12388, 13904, 12912, 17869, 14136

Column Heater for Waters Alliance Series

Specifications:

  • Temperature Range: 20 to 65 °C in 1 °C increments (5 °C above ambient)
Learn More
Waters-WAT270852-HPLC-Column-Compartment-16972
By clicking below we can further assist you with your inquiry. Inquire 14 In Stock Worldwide Shipping
Waters Acquity H Class Column Manager UPLC Column Manager

Waters Acquity H Class Column Manager UPLC Column Manager

Cambridge ID #: 15342

Specifications:

  • Column capacity:
    • CM-A: Two columns, as standard (maximum length of 150 mm with filter or guard column)
    • or four columns (maximum length of 50 mm) can be supported with optional tubing kit,
    • up to 4.6 mm internal diameter (1.0.)
    • CM-Aux: Two columns (maximum length of 150 mm, with filter or guard column) - up to
    • two CM-Aux units can be configured with one CM-A for support of up to six columns
  • Switching valves: Two nine-port, eight-position valves (CM-A only); provides programmable, automatic, random access switching, waste and bypass positions for rapid solvent changeover
  • Temperature Range:
    • 0 to 90.0 ·C, set table in 0.1 ·C increments
    • Two independent heatl cool zones per module, up to six zones in stacked configuration
  • Temperature Accuracy: ±0.5 ·C
  • Temperature Stability: ±0.3 ·C
  • Solvent conditioning: Active pre-heating as standard
  • Column tracking: eCord Technology column information management tracks and archives column usage history
  • 20 support: Optional
Learn More
Waters-Acquity-H-Class-Column-Manager-UPLC-Column-Manager-15342
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Rheodyne EV500-104 Column SelectorImage Coming Soon

Rheodyne EV500-104 Column Selector

Cambridge ID #: 13432

The EV platform continues to offer classic column selectors and other liquid-end possibilities in a stand-alone ready-to-use unit.

Specifications:

  • Differential Pressure Maximum: 5000 psig
  • Positions: 6
  • Ports: 14
Learn More
Rheodyne-EV500-104-Column-Selector-13432
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Perseptive Biosystems Scout Column SelectorImage Coming Soon

Perseptive Biosystems Scout Column Selector

Cambridge ID #: 6962

Description:

Applied Biosystems’ SCOUT Column Selector is an automated multi-column switching unit for use with the BioCAD family of workstations and the INTEGRAL 100Q System. The SCOUT Column Selector allows flow to be diverted to any one of six attached columns. The SCOUT Column Selector offers increased flexibility for both systematic methods development and routine execution of experiments.

Specifications:

  • Valve body/fluid paths: PEEK, carbon-filled PEEK, PTFE, or HMW polyketone
  • Maximum pressure: 3,000 psi
  • Back pressure: <100 psi at 60 ml/min for each line
  • Column sizes: Up to 24 mm diameter and up to 30 cm length
  • Plumbing: 1/16-inch Valco fittings
  • Dimensions (W x L x H): 9.5 in. x 12 in. x 8 5/16 in. (24.1 cm x 30.5 cm x 21.1 cm)
  • Weight: 10 lbs. (4.5 Kg)
  • Power requirements: 100 V/120 V/220 V/240 V, 50/60 Hz, 1.2 amps
  • Fuse rating: 2-amp SLO-BLO
  • Operating temperature: 4°C to 40°C
  • Operating humidity: 10 to 90% non-condensing
Learn More
Perseptive-Biosystems-Scout-Column-Selector-6962
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - HPLC Stack HPLC System

Agilent 1100 Series - HPLC Stack HPLC System

Cambridge Scientific ID #'s: 9596, 9592, 9581

Optional Installation, Familiarization, and Extended Warranty available

 

Includes:

  • G1322 Degasser
  • G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
  • G1313A Autosampler
  • G1316A Column Compartment
  • G1315A Diode Array Detector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

 

The components can be customized to your needs.

 

Please let me know if I can be of any additional assistance.

Learn More
Agilent-1100-Series---HPLC-Stack-HPLC-System-9596
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 9597

Includes: 

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Autosampler
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals
Learn More
Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-9597
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - HPLC Stack HPLC System

Agilent 1200 Series - HPLC Stack HPLC System

Cambridge ID #: 9593

Includes:

  • Agilent G1322A Degasser
  • Agilent G1311A Quat Pump
  • Agilent G1329A Autosampler
  • Agilent G1330A Autosampler Chiller
  • Agilent G1365D DAD (Diode Array Detector)
  • Agilent G1316A Column Compartment
  • Solvent Tray
  • Computer Loaded with ChemStation
  • Cables and Manuals
Learn More
Agilent-1200-Series---HPLC-Stack-HPLC-System-9593
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1260 Series - Infinity HPLC Stack HPLC System

Agilent 1260 Series - Infinity HPLC Stack HPLC System

Cambridge ID #: 19866

Includes:
• G1311 Quarternary Pump or G1312A Binary Pump($1000 Less)
• G1329B Autosampler
• G1316A Column Compartment
• G4212B Dioade Array Detector
• Computer Loaded with OpenLab Software 
• Monitor – Mouse – Keyboard
• Cables and Manuals

The components can be customized to your needs.

Learn More
Agilent-1260-Series---Infinity-HPLC-Stack-HPLC-System-19866
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent Agilent 1100 Series - Prep HPLC Stack  HPLC Preparative System

Agilent Agilent 1100 Series - Prep HPLC Stack HPLC Preparative System

Cambridge ID #: 18658

Includes:

  • Qty (2) - G1361A Agilent 1100 Series Prep Pumps
  • G1315A DAD Diode Array Detector (G1314A VWD Detector also available)
  • G2258A Agilent 1100 Prep Dual Loop Autosampler (Manual Injector also an option)
  • G1364B AFC Automated Fraction Collector
  • Computer Loaded with ChemStation
  • Monitor – Mouse – Keyboard
  • Cables and Manuals

G1361 Prep Pump

Features:

  • Extended flow rate range
  • Without changing pump heads, provides flow rates up to 100 mL/min at 400 bar
  • For preparative and analytical applications with low flow rates (0.5 mL/min, upward), provides precise high-pressure binary gradient formation with low delay volume (700 uL)
  • Automated seal wash using a peristaltic pump extends seal lifetime
  • Pumps stop in response to column blockage or leaks
  • Automated electromagnetic purge valve simplifies system setup
  • Software provides solvent level control that keeps the pump from running dry
Learn More
Agilent-Agilent-1100-Series---Prep-HPLC-Stack-HPLC-Preparative-System-18658
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1310A HPLC Isocratic Pump

Agilent 1100 Series - G1310A HPLC Isocratic Pump

Cambridge ID #: 14776

The HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.

 

 Features:

  • Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
  • Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
  • Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
  • Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.

 

Specifications:

  • Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
  • Settable flow range: .001– 10 ml/min, in 0.001 ml/min increments
  • Flow range: 2 – 10.0 ml/min
  • Recommended pH range: – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel.
  • Operating voltage: 230V

 

Learn More
Agilent-1100-Series---G1310A-HPLC-Isocratic-Pump-14776
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping