We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Hplc Uv/vis Detector: 1-15 of 217

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Waters 2487 HPLC UV/VIS Detector

Waters 2487 HPLC UV/VIS Detector

Cambridge ID #: 16396

The Waters 2487 Dual λ Absorbance Detector is a two-channel, tunable, ultraviolet/visible (UV/Vis) detector designed for high-performance liquid chromatography (HPLC) applications. The Waters 2487 Dual λ Absorbance Detector can operate either as a stand-alone unit (with a chart recorder or integrator) or as an integral part of a Waters chromatography system.

 

Specifications:

  • Wavelength range: 190 to 700 nm
  • Bandwidth: <5 nm
  • Wavelength accuracy: +1.0 nm
  • Wavelength repeatability: +0.1 nm
  • Single λ dry noise: <5 µAU (at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
  • Wet noise: <8 µAU (at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
  • Dual channel noise (dry): <35 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)
  • Dual channel noise (wet): <45 µAU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)
  • Linearity: <5% at 2.5 AU, propylparaben at 257 nm
  • Drift: 1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
  • Thermal drift: 1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
  • Sensitivity setting range: 0.0001 to 4.0000 AUFS
  • Filter setting range
    • Single-wavelength: 0.1 to 5.0 seconds
    • Dual-wavelength: 1 to 50 seconds
  • Time-constant: To 5.0-second Hamming filter
  • Digital data rates:
    • 1,2,5,10,20,40,80 Hz (single channel)
    • 1,2 Hz (dual channel)
  • Analog output data rates (single λ mode):
    • 10,20,40,80 Hz (channel A)
    • 10 Hz only (channel B)
  • Lamp source: 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
  • Second-order filter: Automatic for wavelengths > 370 nm
  • Wavelength calibration filter: Erbium filter, used at startup or on demand
  • Flow cell: TaperSlit flow cell design
  • Nitrogen purge: Purge fitting present on optics bench
  • Path length: 0 mm (standard analytical)
  • Cell volume: 10 µL (standard analytical)
  • Pressure limit: 6895 kPa (69 bar,1000 psi)
  • Materials: 316 stainless steel, fused silica, Tygon
  • Operating temperature: 4 to 40 °C (39 to 104 °F)
  • Operating humidity: 20% to <95%, noncondensing

Learn More
Waters-2487-HPLC-UV-VIS-Detector-16396
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 8453 HPLC UV/VIS Detector

Agilent 8453 HPLC UV/VIS Detector

Cambridge ID #: 20107

System Includes:

  • Agilent G1103A UV-Vis Spectrophotometer
  • G1115AA/BA Spectral B.04.xx 32 Bit Chemstation Software or C.01.xx OpenLab Software (your choice)
  • Computer With Windows 7 Pro or Windows XP Operating System
  • Cables and Accessories

Specifications:

  • Wavelength range: 190–1100 nm
  • Slit width: 1 nm
  • EP resolution test: > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm
  • Stray light:
    • < 0.03 % at 340 nm (NaNO2, ASTM)
    • < 0.05 % at 220 nm (NaI, ASTM)
    • < 1 % at 198 nm (KCl, EP)
  • Wavelength accuracy:
    • < ± 0.5 nm 0.5-second scan (NIST 2034)
    • < ± 0.2 nm at 486.0 and 656.1 nm
  • Wavelength reproducibility: < ± 0.02 nm ten consecutive scans (NIST 2034)
  • Photometric accuracy:
    • < ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)
    • < ± 0.01 A at 235, 257, 313, 350, 430 nm, (potassium dichromate, EP method)
  • Photometric noise: < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms
  • Photometric stability: < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp.
  • Baseline flatness: < 0.001 A 0.5-second blank, 0.5-second scan, rms
  • Typical scan time: 5 second full range
  • Shortest scan time: 1 second full range
  • Time until next scan: 1 second full range, 0.1-second scan, up to 150 consecutive scans
Learn More
Agilent-8453-HPLC-UV-VIS-Detector-20107
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Waters Acquity H Class PDA Detector UPLC PDA Detector

Waters Acquity H Class PDA Detector UPLC PDA Detector

Cambridge ID #: 24677
  • This Waters ACQUITY UPLC H-Class System is the only quaternary based liquid chromatographic system that was designed for TRUE UPLC PERFORMANCE without compromise. Whether you routinely develop new methods or you perform routine analysis and support large numbers of samples, the ACQUITY UPLC H-Class System can help you reach your laboratory"™s goals of decreasing the time to result, while increasing the depth and quality of the information about your samples.
  • Learn More
    Waters-Acquity-H-Class-PDA-Detector-UPLC-PDA-Detector-24677
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

    Agilent 1100 Series - G1314A HPLC Variable Wavelength Detector

    Cambridge Scientific ID #'s: 16036, 18127, 19166, 21297

    Specification:

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Wavelength range: 190–600 nm
    • Short term noise (ASTM): ±0.75×10-5 AU at 254 nm
    • Drift: 3 × 10 -4 AU/hr at 254 nm
    • Linearity: 2 AU (5%) upper limit
    • Wavelength accuracy:
    • Band width: 5 nm typical
    • Flow cells:
      • Standard: 14-μl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
      • High pressure: 14-μl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
      • Micro: 1-μl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
      • Semimicro: 5-μl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
    • Control and data evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter
    • Housing: All materials recyclable.
    Learn More
    Agilent-1100-Series---G1314A-HPLC-Variable-Wavelength-Detector-16036
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Agilent 1100 Series - G1315A HPLC Diode Array Detector

    Agilent 1100 Series - G1315A HPLC Diode Array Detector

    Cambridge ID #: 19152

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19152
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

    Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 26233, 22326

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Hewlett-Packard-1100-Series---G1315A-HPLC-Diode-Array-Detector-26233
    By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
    Agilent 1100 Series - G1315B HPLC Diode Array Detector

    Agilent 1100 Series - G1315B HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 16038, 25375, 22469, 24755

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-16038
    By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
    Precision Detectors PD2123 HPLC Absorbance Detector

    Precision Detectors PD2123 HPLC Absorbance Detector

    Cambridge ID #: 13616

    Features:

     

    PD2100 Series Detector



    Learn More
    Precision-Detectors-PD2123-HPLC-Absorbance-Detector-13616
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1321A HPLC Fluorescence Detector

    Agilent 1100 Series - G1321A HPLC Fluorescence Detector

    Cambridge Scientific ID #'s: 11836, 22335, 16041, 22114, 17969, 13408, 16314, 16001, 10262

    Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

     

    The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

    • Simplified optical design for optimized baseline stability.
    • Long-life Xenon lamp for highest sensitivity.
    • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
    • Easy front access to flow cell for fast inspection or exchange.

     

    Specifications

    • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
    • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
    • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
    • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
    • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
    • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
    • Reference system: Inline excitation measurement
    • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
    • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
    • Step size: 1—20 nm
    • Spectra storage: Limited only by disk space
    • Wavelength repeatability: ±0.2 nm
    • Wavelength accuracy: ±3 nm
    • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
    • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
    • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    Learn More
    Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
    By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
    Dionex LC Packings UVD-3000 HPLC Detector

    Dionex LC Packings UVD-3000 HPLC Detector

    Cambridge ID #: 15447

    Specifications:


    Noise: ±1 × 10–5 AU (254 nm, 2.0 s response time)
    Drift: 2× 10–4 AU/h
    Response Time: 0.1/0.2/0.5/1/2/5/10 s
    Wavelengths: Up to four simultaneously, user-selectable
    Wavelength Range and Accuracy: 190–740 nm, ± 2nm
    Bandwidth: <8 nm
    Flow Cell Volume: Nano LC, 3 nL volume; Capillary LC, 45 nL volume; Micro LC, 180 nL volume
    Maximum Cell Pressure: 400 bar (6000 psi)
    Lamp: Deuterium
    Data Collection Rate: 1–10 Hz
    Analog Output: 2×1 V
    Dimensions (h × w × d): 16 × 42 ×51 cm (6.3 ×16.3 × 20 in.)
    Weight: 10.5 kg (23 lb)

    Learn More
    Dionex-LC-Packings-UVD-3000-HPLC-Detector-15447
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

    Cambridge ID #: 11049

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

    Cambridge Scientific ID #'s: 23960, 17971, 13182, 23203, 16326, 21821

    Specifications:

    • Detection type: 1024-element photodiode array
    • Light source: Deuterium and tungsten lamps
    • Wavelength range: 190 – 950 nm
    • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
    • Drift: 2 × 10-3AU/hr at 254 nm
    • Linear absorbance Range: 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 – 400 nm
    • Slit width: 1, 2, 4 , 8, 16 nm
    • Diode width: < 1 nm
    • Flow cells
      • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
      • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
      • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
      • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
    • Control and data Evaluation: Agilent ChemStation for LC
    • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
    • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
    • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
    • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-23960
    By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
    Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

    Agilent 1200 Series - G1314B HPLC Variable Wavelength Detector

    Cambridge ID #: 22633

    Specifications: 

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Noise: ± 0.75 x 10 -5 AU, at 254 nm
    • Drift: 3 x 10-4AU/hr, at 254 nm
    • Linearity: >2 AU upper limit
    • Wavelength range: 190-600 nm
    • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
    • Maximum data rate: 55 Hz
    Learn More
    Agilent-1200-Series---G1314B-HPLC-Variable-Wavelength-Detector-22633
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

    Agilent 1200 Series - G1314C HPLC Variable Wavelength Detector

    Cambridge ID #: 15899

    Specifications: 

    • Detection type: Double-beam photometer
    • Light source: Deuterium lamp
    • Noise: ± 0.75 x 10 -5 AU, at 254 nm
    • Drift: 3 x 10-4AU/hr, at 254 nm
    • Linearity: >2 AU upper limit
    • Wavelength range: 190-600 nm
    • Wavelength accuracy: ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
    • Wavelength bandwidth: 6.5 nm typical over whole wavelength range
    • Maximum data rate: 55 Hz
    Learn More
    Agilent-1200-Series---G1314C-HPLC-Variable-Wavelength-Detector-15899
    By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
    Agilent 1200 Series - G1315B HPLC Diode Array Detector

    Agilent 1200 Series - G1315B HPLC Diode Array Detector

    Cambridge Scientific ID #'s: 24427, 24130, 24717

    The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

     

    Specifications:

    • Wavelength range: 190-950 nm
    • Light source: Deuterium and tungsten lamps
    • Detection type: 1024 - element photodiode array
    • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
    • Drift: 2° x 10-3 AU / hr at 254 nm
    • Linear absorbance range: > 2 AU (upper limit)
    • Wavelength accuracy: ± 1 nm
    • Wavelength bunching: 1 - 400 nm
    • Diode width: < 1 nm
    • Control and data evaluation: Agilent Chemstation for LC
    • Slit width: 1, 2, 4, 8, 16 nm

     

    Can be sold as an individual component or as part of a complete stack

    Learn More
    Agilent-1200-Series---G1315B-HPLC-Diode-Array-Detector-24427