We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Microscope Fluorescence Light Source: 316-330 of 341

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Savant SPD111V-120 SpeedVac Concentrator

Savant SPD111V-120 SpeedVac Concentrator

Cambridge Scientific ID #'s: 11262, 5986

The small-capacity concentrator series handles varying solvents for different applications. The SPD 111V model is designed for aqueous solvent applications and vacuum evaporation. The SPD 111V handles sample concentration using low concentrations of non-aggressive organic solvents like Acetonitrile and Methanol.

 

Features:

  • Accommodates deep-well plates
  • Integrated automatic bleeder valve
  • Variable drying rate
  • Connector for vacuum source
  • Time/temperature display incorporating membrane touch pad switches
  • Safety coverlock
  • Radiant cover for accelerated evaporation (optional)
  • Manual/auto timed run

 

Learn More
Savant-SPD111V-120-SpeedVac-Concentrator-11262
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Molecular Devices SpectraMax 340PC Microplate UV/VIS Reader

Molecular Devices SpectraMax 340PC Microplate UV/VIS Reader

Cambridge Scientific ID #'s: 12898, 7496, 12899

Includes:

  • Computer Loaded with Softmax Pro 5.4.1
  • All Necessary Cables and Cords
  • Manuals

 

General Specifications

  • Dimensions (in.): 8.6 (h) x 22.8 (w) x 15 (d)

 

Performance Specifications

  • Wavelength Range: 340 - 850 nm
  • Wavelength Selection: Monochromator, tunable 1.0 nm increments
  • Wavelength Bandwidth: 2 nm
  • Wavelength Accuracy: < ± 1.0 nm
  • Wavelength Repeatability: ± 0.2 nm
  • Photometric Range: 0.0 to 4.0 OD
  • Photometric Accuracy: < ± 0.006 OD ± 1.0%, 0.0 - 2.0 OD
  • Photometric Precision: < ± 0.003 OD ± 1.0%, 0.0 - 2.0 OD
  • Light Source: Xenon flash lamp
  • Temperature Range: Ambient + 4 °C up to 45 °C
  • Temperature Uniformity: ± 0.5 °C @ 37 °C

 

Microplate Read Time:

  • Endpoint
    • 96-well: 9 seconds
    • 384-well: 29 seconds
  • Kinetic
    • 96-well: 9 second minimum interval
    • 384-well: 29 second minimum interval
Learn More
Molecular-Devices-SpectraMax-340PC-Microplate-UV-VIS-Reader-12898
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Molecular Devices SpectraMax M2 Multimode Microplate Reader

Molecular Devices SpectraMax M2 Multimode Microplate Reader

Cambridge Scientific ID #'s: 20670, 18788, 16123

Premier dual-mode readers for absorbance & fluorescence intensity-based assays. Users can select from top- or bottom-read modes for improved sensitivity for solution and cell-based assays.

 

Includes:

  • SoftMax Pro software version 5.4.1
  • Computer Workstation w/ Flat Screen Monitor
  • Complete Set of Communication & Power Cables
  • User/Reference Manuals for M2 and SoftMax Pro software

 

Specifications:

 

  • Absorbance Photometric Performance
  • Wavelength range: 200-1000 nm
  • Wavelength selection: Monochromator
  • Wavelength bandwidth: ≤ 4.0 nm
  • Wavelength accuracy: ±2.0 nm
  • Wavelength repeatability: ±0.2 nm

 

Fluorescence Photometric Performance (M2)

 

  • Dual monochromators: 1 nm increments
  • EX 250-850 nm
  • EM 360-850 nm
  • Bandwidth (EX, EM): 9, 9 nm
  • Detection limit: 3.0 fmol/well FITC 200 μL in 96 wells
Learn More
Molecular-Devices-SpectraMax-M2-Multimode-Microplate-Reader-20670
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Molecular Devices SpectraMax M2e Multimode Microplate Reader

Molecular Devices SpectraMax M2e Multimode Microplate Reader

Cambridge ID #: 19768

Premier dual-mode readers for absorbance & fluorescence intensity-based assays. Users can select from top- or bottom-read modes for improved sensitivity for solution and cell-based assays.

 

Includes:

  • SoftMax Pro software version 5.4.1
  • Computer Workstation w/ Flat Screen Monitor
  • Complete Set of Communication & Power Cables
  • User/Reference Manuals for M2 and SoftMax Pro software

 

Specifications:

 

  • Absorbance Photometric Performance
  • Wavelength range: 200-1000 nm
  • Wavelength selection: Monochromator
  • Wavelength bandwidth: ≤ 4.0 nm
  • Wavelength accuracy: ±2.0 nm
  • Wavelength repeatability: ±0.2 nm

 

Fluorescence Photometric Performance (M2)

 

  • Dual monochromators: 1 nm increments
  • EX 250-850 nm
  • EM 360-850 nm
  • Bandwidth (EX, EM): 9, 9 nm
  • Detection limit: 3.0 fmol/well FITC 200 μL in 96 wells
Learn More
Molecular-Devices-SpectraMax-M2e-Multimode-Microplate-Reader-19768
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Devices Spectramax M5 Multimode Microplate Reader

Molecular Devices Spectramax M5 Multimode Microplate Reader

Cambridge Scientific ID #'s: 17000, 16477, 19342, 19292, 17180

The SpectraMax M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change filters. The SpectraMax M5 is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates.

 

Includes:

  • Computer w/ Softmax Pro 5.4
  • Manuals
  • Cables

 

Multiple detection modes

  • UV-Visible Absorbance (Abs)
  • Fluorescence Intensity (FI)
  • Time-Resolved Fluorescence (TRF)
  • Fluorescence Polarization (FP)
  • Glow Luminescence (Lumi)

 

Features

  • Multiple Detection Modes
  • Precision Optics and Detectors
  • Patented AutoPMT Optimization System
  • Patented PathCheck® Pathlength Measurement Technology
  • Comprehensive Reader Validation
  • Automating with Ease

 

General Photometric performance

 

Plate Formats

  • 6, 12, 24, 48, 96, 384 wells

Light Source

  • Xenon Flash Lamp (1 joule/flash)

Detectors

  • 2 photomultiplier tubes

ShakerTime

  • 0 to 999 seconds

Temperature Control

  • 2 °C above ambient to 60 °C

Temperature Uniformity

  • < 1°C at 37°C set point

Temperature Accuracy

  • ±1°C at 37°C set point

Endpoint Reading

  • All modes

Kinetic Reading

  • All modes

Spectral Scanning

  • All modes

Well Scanning

  • Abs, FI, TRF, Lum
Learn More
Molecular-Devices-Spectramax-M5-Multimode-Microplate-Reader-17000
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Molecular Devices SpectraMax M5e Multimode Microplate Reader

Molecular Devices SpectraMax M5e Multimode Microplate Reader

Cambridge ID #: 20644

The SpectraMax M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change filters. The SpectraMax M5 is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates.

 

Includes:

  • Computer w/ Softmax Pro 5.4
  • Manuals
  • Cables

 

Multiple detection modes

  • UV-Visible Absorbance (Abs)
  • Fluorescence Intensity (FI)
  • Time-Resolved Fluorescence (TRF)
  • Fluorescence Polarization (FP)
  • Glow Luminescence (Lumi)

 

Features

  • Multiple Detection Modes
  • Precision Optics and Detectors
  • Patented AutoPMT Optimization System
  • Patented PathCheck® Pathlength Measurement Technology
  • Comprehensive Reader Validation
  • Automating with Ease

 

General Photometric performance

 

Plate Formats

  • 6, 12, 24, 48, 96, 384 wells

Light Source

  • Xenon Flash Lamp (1 joule/flash)

Detectors

  • 2 photomultiplier tubes

ShakerTime

  • 0 to 999 seconds

Temperature Control

  • 2 °C above ambient to 60 °C

Temperature Uniformity

  • < 1°C at 37°C set point

Temperature Accuracy

  • ±1°C at 37°C set point

Endpoint Reading

  • All modes

Kinetic Reading

  • All modes

Spectral Scanning

  • All modes

Well Scanning

  • Abs, FI, TRF, Lum
Learn More
Molecular-Devices-SpectraMax-M5e-Multimode-Microplate-Reader-20644
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Applied Biosystems StepOnePlus Real-Time qPCR System

Applied Biosystems StepOnePlus Real-Time qPCR System

Cambridge ID #: 20110

Includes Computer loaded w/ Step One Software

 

The StepOnePlus Real-Time PCR System is a 96-well Real-Time PCR instrument perfect for both first-time and experienced users. The StepOnePlus Real-Time PCR System can be setup in a variety of configurations and comes ready to use, out of the box, with intuitive data analysis and instrument control software. Utilizing robust LED based 4-color optical recording, the StepOnePlus Real-Time PCR System is designed to deliver precise, quantitative Real-Time PCR results for a variety of genomic research applications.

Features of the StepOnePlus Real-Time PCR System include:

  • Advanced software and instrumentation for performing a wide array of genomic assays
  • Sensitive 4-color optical LED recording system
  • Intuitive and robust software perfect for both first-time and advanced users
  • Simple and flexible instrument set-up and usage

 

Specifications:

  • Capacity: 1 x 96-well plate, 12 x 8-tube strips, 96 x 0.1 ml tubes
  • Detection Method: Primer-Probe Detection, SYBR
  • Dimensions: 24.6 cm/9.7 in.(W) x 42.7 cm/16.8 in.(D) x 51.2 cm/20.2 in.(H)
  • Dynamic Range: Linear Dynamic Range greater than 9 log units (detection)
  • Format: 0.1 ml tubes, 8-tube strips, 96-well plate
  • Green Features: Energy efficient, Fewer resources used, Sustainable disposal
  • High Throughput Compatibility: Multiplexing
  • Optics: 4 emission filters, Blue LED excitation source, photodiode
  • Passive Reference Dye: No ROX, ROX (Pre-mixed), ROX (Separate Tube)
  • Peak Block Ramp Rate: 4.6°C⁄sec
  • Reaction Speed: Fast, Standard
  • Reaction Volume Range: 10-30 µl (Standard curve experiments: 40 µl in standard mode is validated)
  • Run Time: <2 hrs⁄run (Standard Mode), <40 min⁄run (Fast Mode)
  • Sample Ramp Rate: Fast mode: ± 2.2°C⁄sec, Standard mode: ± 1.6°C⁄sec
  • Temperature Accuracy: 0.25°C (35 to 95°C) of display temperature
  • Temperature Range (Metric): 4-100°C
  • Temperature Uniformity: 0.25°C (35 to 95°C) of setpoint/display temperature
  • Thermal Cycling System: Peltier-Based System
  • Weight: 24 kg (53 lbs.)
Learn More
Applied-Biosystems-StepOnePlus-Real-Time-qPCR-System-20110
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
BioTek Synergy 4 Multimode Microplate Reader

BioTek Synergy 4 Multimode Microplate Reader

Cambridge ID #: 20101

The Synergy 4 is the first multi-mode reader that combines both filter-based and quadruple monochromator-based fluorescence detection technology. In addition, Synergy 4 includes Fluorescence Intensity, Luminescence, Fluorescence Polarization, Time-Resolved Fluorescence, and UV-Visible Absorbance for endless flexibility in current and future microplate-based assay choice.

Filter-based fluorescence technology provides optimal light filtering and purification for the best sensitivity. The inherent design of filter systems also provides fast wavelength switching and higher read speeds. On the other hand, the quadruple monochromator-based fluorescence technology offers flexible wavelength selection, true spectral scanning, reduced background noise and increased convenience. The combination of the filter and monochromator systems in one unit means that microplate assay choice is no longer restricted by the technology of the microplate reader.

Learn More
BioTek-Synergy-4-Multimode-Microplate-Reader-20101
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Invitrogen Tali T10791 Cytometer

Invitrogen Tali T10791 Cytometer

Cambridge ID #: 18329

The Tali Image-Based Cytometer is a 3-channel (bright field, green fluorescence, red fluorescence) benchtop assay platform that uses state-of-the-art optics and image analysis to perform assays for cells in suspension, including GFP and RFP expression, apoptosis, cell viability (live, dead, and total cells), cell cycle, and cell counting assays. It is compatible with a wide variety of eukaryotic cells. In addition to the bright field channel, the Tali® Image-Based Cytometer features two fluorescent channels (green and red), enabling it to simultaneously count green or red fluorescent stains, as well as cells expressing GFP and RFP.

 

Specification:

 

  • Instrument type: Benchtop cell counter and suspension cell-based assay platform
  • Dimensions (W x D x H): 11.5 x 17.5 x 11.5 in.
  • Weight: 19.4 lbs
  • Operating power: 100–240 VAC, 2.5 A, 120 V
  • Frequency: 50/60 Hz
  • Electrical input: 12 VDC, 13 A
  • Installation site: Indoor use only, Class A environments; pollution degree 2
  • Operating temperature: 10 - 40°C
  • Operating humidity: < 80% (non-condensing)
  • Processing time: 10 seconds to 2 minutes, depending on the number of fields captured
  • Sample concentration range: 1 x 10^5 - 1 x 10^7 cells / mL
  • Particle/cell diameter range: 5-60 µm
  • Required sample volume: 25 µL
  • Firmware: Tali Image-Based Cytometer Firmware
  • USB drive: 4 Gigabyte
  • Optics: 3 channels (bright field, green fluorescence, red fluorescence)
  • Excitation: Green channel LED (458 ± 20 nm), Red channel LED (530 ± 20 nm)
  • Green channel filter: 466/40 EX, 495 LP Di, 525/50 EM
  • Red channel filter: 543/22 EX, 580 LP Di, 585 LP EM
  • Camera: 1.3 Mega pixels, 4x objective, 4x or 16x digital zoom
Learn More
Invitrogen-Tali-T10791-Cytometer-18329
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Nikon TE-2000-E Dual Port Motorized Inverted/High End Research Microscopes

Nikon TE-2000-E Dual Port Motorized Inverted/High End Research Microscopes

Cambridge ID #: 18792

Description: The TE2000-E incorporates a high precision motorized focus and vibration-free motorized optical-path changeover mechanism that facilitates image capture in 3D. The TE2000-E comes with five output ports.

Specifications:

  • Black box incubator
  • Prior light source
  • Mechanical XY stage
  • Motorized nosepiece
  • Motorized focus
  • Motorized Fluor Turret
  • Perfect focus (anti-drift)
  • Phase contrast
  • DIC
  • Fluorescence
  • 1.5 magnification changer
  • Prior motorized emission wheel
  • Cubes:
    • YFP
    • Multi-cube UV/D/F/TR
    • SRIC
  • Temperature and Humidity control
  • CO2
  • Objectives:
    • 10x Fluor Phase
    • 20x Plan APO DIC Dry
    • 40x Plan Fluor Oil
    • 40x Plan Fluor Phase
    • 100x Plan Apo DIC Oil
  • Lumin 200 Pro light source
  • Cool Snap HQ2
  • Proscan 2
Learn More
Nikon-TE-2000-E-Dual-Port-Motorized-Inverted-High-End-Research-Microscopes-18792
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare Typhoon FLA 7000 Variable Mode Imager System

GE Healthcare Typhoon FLA 7000 Variable Mode Imager System

Cambridge ID #: 20050

Includes Computer Loaded w/Control Software

 

The Typhoon FLA 7000 is a fast and versatile laser scanner for biomolecular imaging applications including sensitive and quantitative measurements of radioisotopic labels by storage phosphor and single fluorescence, as well as digitization of colorimetric stains (e.g., Coomassie™ Blue and silver-stained gels). Typhoon FLA 7000 IP is a model dedicated to phosphor imaging. It comes with only one laser configuration. Upgrade paths for any of blue, green, and red excited fluorescence imaging are provided.  

 

Features:

  • Versatility: The system images radioisotopic, visible fluorescent, chemifluorescent, and colorimetric samples.
  • High resolution and quantitation: 16-bit images are generated at up to 25 μm pixel resolution. A linear signal response over a span of five orders of magnitude gives precise quantitation in gels, blots, and tissue sections.
  • High speed: a 24 × 25 cm gel can be scanned in less than two minutes at 100 μm resolution without compromising sensitivity
  • High sample throughput: a scanning area of 24 × 40 cm enables simultaneous imaging of up to 12 gels or blots, measuring 10 × 8 cm in size. This facilitates comparisons among blots, and reduces workload and waiting time.

 

Specifications:

  • Imaging modes: Fluorescence, phosphorimaging, and digitization
  • Excitation wavelengths:
    • 473 nm (blue LD laser),
    • 532 nm (green SHG laser)
    • 635 nm (red LD laser)
    • 650 nm (red LD laser)
  • Dynamic range: 5 orders of magnitude
  • Bit depth: 16-bit
  • Max scanning area:
    • Phosphorimaging: 20 × 40 cm
    • Fluorescence: 24 × 40 cm
  • Pixel sizes: 25, 50, 100, and 200 μm
  • Standard filters: IP (phosphorimaging), Y520, O580, R670
  • Dimensions (W × H × D): 940 × 360 × 556 mm
  • Weight: 62 kg
  • Line frequency: 50 to 60 Hz
  • Temperature: 15°C to 30°C
  • Humidity: 30% to 70% (no condensation)
  • Supply voltage: 100 - 240 VAC ± 10%
  • Power consumption: Approx. 0.3 kVA
Learn More
GE-Healthcare-Typhoon-FLA-7000-Variable-Mode-Imager-System-20050
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare Typhoon Trio Variable Mode Imager System

GE Healthcare Typhoon Trio Variable Mode Imager System

Cambridge ID #: 14509

The Typhoon instrument is a variable-mode imager that produces digital images of radioactive, fluorescent, or chemiluminescent samples. The Typhoon instrument is available in several models. The Typhoon Trio instrument contains three internal lasers (blue, green, and red).

 

Includes:

 

  • Red, Blue, Green Laser Modules Built in
  • Image Quant and Scan Control Software loaded on computer
  • All Necessary Cables, Cords and Manuals

 

For DNA, RNA, and protein samples, users can choose from:

  • Storage phosphor autoradiography
  • Direct green (532 nm) excited fluorescence
  • Direct red (633 nm) excited fluorescence
  • Direct blue (488 nm) excited fluorescence
  • Chemiluminescence

 

Features:

  • When one of the five scanning modes is selected, the appropriate optical components are automatically activated.
  • Typhoon imagers scan mounted and unmounted storage phosphor screens, gels and blots up to 35 x 43 cm as well as microarrays.
  • Typhoon imagers exhibit outstanding linearity and quantitative  accuracy, and include ImageQuant TL Image Analysis Software.
  • Typhoon imagers are fully optimized as part of the Ettan DIGE system, and seamless integration with DeCyder Differential Analysis Software
  • is ensured for all models.
  • Special tray templates that are part of the latest scanner control software and new optional Gel Alignment Guides add higher throughput and ease of handling 2-D gels run on Ettan DALT and SE600.

 

Learn More
GE-Healthcare-Typhoon-Trio-Variable-Mode-Imager-System-14509
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
GE Healthcare Typhoon Trio plus Variable Mode Imager System

GE Healthcare Typhoon Trio plus Variable Mode Imager System

Cambridge ID #: 20645

The Typhoon instrument is a variable-mode imager that produces digital images of radioactive, fluorescent, or chemiluminescent samples. The Typhoon instrument is available in several models. The Typhoon Trio instrument contains three internal lasers (blue, green, and red).

 

Includes:

 

  • Red, Blue, Green Laser Modules Built in
  • Image Quant and Scan Control Software loaded on computer
  • All Necessary Cables, Cords and Manuals

 

For DNA, RNA, and protein samples, users can choose from:

  • Storage phosphor autoradiography
  • Direct green (532 nm) excited fluorescence
  • Direct red (633 nm) excited fluorescence
  • Direct blue (488 nm) excited fluorescence
  • Chemiluminescence

 

Features:

  • When one of the five scanning modes is selected, the appropriate optical components are automatically activated.
  • Typhoon imagers scan mounted and unmounted storage phosphor screens, gels and blots up to 35 x 43 cm as well as microarrays.
  • Typhoon imagers exhibit outstanding linearity and quantitative  accuracy, and include ImageQuant TL Image Analysis Software.
  • Typhoon imagers are fully optimized as part of the Ettan DIGE system, and seamless integration with DeCyder Differential Analysis Software
  • is ensured for all models.
  • Special tray templates that are part of the latest scanner control software and new optional Gel Alignment Guides add higher throughput and ease of handling 2-D gels run on Ettan DALT and SE600.

 

Learn More
GE-Healthcare-Typhoon-Trio-plus-Variable-Mode-Imager-System-20645
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 ACC-3000  HPLC Autosampler

Dionex Ultimate 3000 ACC-3000 HPLC Autosampler

Cambridge ID #: 20019

Features:

 

The following features help you to identify and eliminate the source for problems that may occur during the operation of the autosampler or an UltiMate 3000 system: Status LEDs The status LEDs (light emitting diodes) on the front panel provides a quick visual check of the operational status of the autosampler. They indicate whether the autosampler is turned on, connected in Chromeleon, and operating properly. Messages If a fault or error is detected during the operation of the autosampler, a message appears on the autosampler display. Check the Messages on the Autosampler Display section for recommended courses of action. If the autosampler is operated from Chromeleon, a message is displayed also in the Chromeleon Audit Trail



Specifications:

  • Injection methods: Inline split-loop
  • Needle wash: Active external needle wash
  • WPS-3000TSL:

 

 

Sample thermostatting: 4-45C or 22C below ambient

Sample temperature accuracy: +-2C at a setpoint of 10C at an ambient temperature of less than 25C and less than 50% relative humidity 

  • Weight:

WPS-3000SL:19KG

WPS-3000TSL:24kg

  • Dimensions(h x w x d): 36x42x51 cm(14.2x16.5x20 inch)
  • PC connection: All functions controllable via USB, integrated USB hub with three USB 1.1 spots

 

  • Safety features:

 

Leak sensor, sample container detection, internal monitoring of all mechanical operations. WPS-3000TSL: Monitoring of the function and cooling performance by 3 temperature sensors

  • Power requirement: 100–120 V, 60 Hz; 200–240 V, 50 Hz; max. 150 VA (WPS-3000SL), max. 320 VA (WPS-3000TSL)
Learn More
Dionex-Ultimate-3000-ACC-3000-HPLC-Autosampler-20019
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Dionex Ultimate 3000 VWD-3100 HPLC Variable Wavelength DetectorImage Coming Soon

Dionex Ultimate 3000 VWD-3100 HPLC Variable Wavelength Detector

Cambridge ID #: 17926

Specifications:

  • Optical design: Dual-beam photometer
  • Light source: Deuterium lamp and tungsten lamp
  • Wavelength range: 190 to 900 nm
  • Wavelength accuracy: ± 1 nm
  • Wavelength repeatability: y: ± 0.1 nm
  • Optical bandwidth: 6 nm at 254 nm
Learn More
Dionex-Ultimate-3000-VWD-3100-HPLC-Variable-Wavelength-Detector-17926
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping