We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Real Time Pcr: 61-75 of 764

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Benchmark Scientific Thermal T5000 *NEW* PCR / Thermal Cyclers

Benchmark Scientific Thermal T5000 *NEW* PCR / Thermal Cyclers

Cambridge ID #: 18226

Benchmark's TC9639 Thermal Cycler provides consistent, reliable results for laboratories with medium to high throughput. From its large, touch-screen user interface to its unique, multi-format block, this cycler is loaded with features. A large, full color touch screen serves as the operations center where all functions are accessed. The fully adjustable heated lid prevents condensation and evaporation of samples.  Lid temperature can be programmed, and when the block temperature is below 35°, the lid automatically shuts off. Heating and cooling of the block are precisely and accurately controlled within exceptionally tight tolerances by a proprietary algorithm that simulates sample temperature. With the multi-format block, there is no need for the expense of multiple interchangeable blocks.

 

Specifications:

 

 

  • Capacity:

 

    • 96 Well Block - 96 x 0.2ml tubes / strips or 1 PCR plate or 39 x 0.5ml
    • 384 Well Block - 1 x 384 well plate
  • In-Situ Adapter: 4 slides (for use with 9639 block)
  • Temp Control Range: 0° to 100°C
  • Temp Control: Simulated sample or block
  • Accuracy/Uniformity: ± 0.2°C / ± 0.2°C
  • Ramp Rate: 4°C / Sec. (maximum)
  • Lid Temp: 30°C to 112°C, user adjustable
  • Program Memory: Unlimited with flash drive
  • Increments/Decrements: Yes, both time and temperature
  • Power Supply: Universal, 75 to 275V, 50 to 60Hz
  • Communication: USB, LAN and RS232
  • Dimensions: 10.2 x 14.2 x 9.9 in. / 26 x 36 x 25cm
  • Weight: 16 lbs. / 7.3kg
Learn More
Benchmark-Scientific-Thermal-T5000-*NEW*-PCR---Thermal-Cyclers-18226
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  FC5816 *NEW* Benchtop Centrifuge

Ohaus FC5816 *NEW* Benchtop Centrifuge

Cambridge ID #: 20272

Features:

Frontier 5000 Multi Pro Centrifuges are designed for universal use in research, industrial & clinical laboratories, and can be combined with our rotors & accessories for customized use in specific applications. Available in 5 models with capacities from low microliter to 6x250 ml, and featuring high-speed performance at maximum volume, automatic rotor identification and safety features - these multi-purpose centrifuges are a must for any lab.

Applications

Centrifugal Separation, General Sample Preparation, Cell Pelleting, Protein Separation, Nucleic Acid Separation, Cell Concentrating, Chemical Separation, Diagnostics, Environmental Sample Preparation, Blood Sample Processing

Display

Backlit Liquid Crystal Display (LCD)

Operation

Designed to be used with a variety of rotors and accessories

Communication

N/A

Construction

Corrosion-resistant stainless steel chamber with Polycarbonate/ABS plastic lid

Design Features

Ten acceleration & deceleration rates, selection of running time from 10s to 99h 59min or continuous, quick spin, CFC-free refrigeration system, sample temp. indication (refrigerated models), lid-locking system, over-speed protection, dual imbalance sensing

 

Specifications:

 

 

  • Speed Range:200 rpm – 15,000 rpm
  • Maximum Relative Centrifuge Force (x g):21,379 g
  • Maximum Capacity (Rotor):6x250 ml
  • Acceleration Gear:10
  • Deceleration Gear:10
  • Dimensions (HxLxW):13.94 in x 21.18 in x 17.56 in (354 mm x 538 mm x 446 mm)
  • Display: LCD with backlight
  • Net Weight:115 lb (52 kg)
  • Noise Level:≤61±2 dB(A)
  • Power Consumption: 520 W
  • Rotor Recognition Method: Auto
  • Running Time: Quickspin;  10 sec to 99 h 59 min 59 sec;  Continous
  • Safety Certification: CE;  FCC
  • Working Environment:36°F – 95°F, 80%RH, non-condensing (2°C – 35°C, 80%RH, non-condensing)

 

 

Learn More
Ohaus-FC5816-*NEW*-Benchtop-Centrifuge-20272
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  Pioneer Precision  PX4202/E *NEW* Precision Balances

Ohaus Pioneer Precision PX4202/E *NEW* Precision Balances

Cambridge ID #: 20313

Features:

 

The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications

Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination

Display

Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)

Operation

AC adapter (included)

Communication

RS232 and USB device (included); GLP/GMP data output with real-time clock

Construction

Metal base, plastic top housing, removable stainless steel pan, glass draft shield, integrated weigh-below-hook, security bracket, calibration lock, and in-use cover

Design Features

User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages

 

Specifications:

 

  • Maximum Capacity: 4200 g
  • Readability: 0.01 g
  • Pan Size (LxW): 180 mm
  • Dimensions (HxLxW): 98 mm x 321 mm x 209 mm
  • Display2-Line LCD with Backlight
  • Linearity ±: 1 g
  • Net Weight: 7.7 lb (3.5 kg)
Learn More
Ohaus-Pioneer-Precision--PX4202-E-*NEW*-Precision-Balances-20313
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  Pioneer Precision PX2201/E *NEW* Precision Balances

Ohaus Pioneer Precision PX2201/E *NEW* Precision Balances

Cambridge ID #: 20312

Features:

 

The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications

Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination

Display

Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)

Operation

AC adapter (included)

Communication

RS232 and USB device (included); GLP/GMP data output with real-time clock

Construction

Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover

Design Features

User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages

 

Specifications:

 

  • Maximum Capacity: 2200g
  • Readability: 0.1 g
  • Pan Size (LxW): 180 mm
  • Dimensions (HxLxW): 98 mm x 321 mm x 209 mm
  • Display2-Line LCD with Backlight
  • Linearity ±: 1 g
  • Net Weight: 7.7 lb (3.5 kg)
Learn More
Ohaus-Pioneer-Precision-PX2201-E-*NEW*-Precision-Balances-20312
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  Pioneer Precision PX4201/E *NEW* Precision Balances

Ohaus Pioneer Precision PX4201/E *NEW* Precision Balances

Cambridge ID #: 20311

Features:

 

The Pioneer PX combines essential weighing functionality with competitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education settings. The PX is affordably priced, and intuitively designed for intelligent operation with a second line display for additional information, and USB and RS232 connectivity for easy communication.

Applications

Basic Weighing, Parts Counting, Percent Weighing, Animal Weighing, Density Determination

Display

Backlit Liquid Crystal Display (LCD); Second line display for additional information or guidance (dot matrix)

Operation

AC adapter (included)

Communication

RS232 and USB device (included); GLP/GMP data output with real-time clock

Construction

Metal base, plastic top housing, removable stainless steel pan, glass draftshield, integrated weigh-below-hook, security bracket, calibration lock and in-use cover

Design Features

User-selectable environmental filters and brightness settings, auto-tare, auto-dim, user-selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user-definable project and user IDs, software overload/underload indicator, stability indicator, four operating languages

 

Specifications:

 

  • Maximum Capacity: 4200g
  • Readability: 0.1 g
  • Pan Size (LxW): 180 mm
  • Dimensions (HxLxW): 98 mm x 321 mm x 209 mm
  • Display2-Line LCD with Backlight
  • Linearity ±: 1 g
  • Net Weight: 7.7 lb (3.5 kg)
Learn More
Ohaus-Pioneer-Precision-PX4201-E-*NEW*-Precision-Balances-20311
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Ohaus  VXMPAL *NEW* Vortexer

Ohaus VXMPAL *NEW* Vortexer

Cambridge ID #: 20247

Features:

OHAUS Microplate Vortex Mixers are perfect for mixing microplates throughout the speed range. All models are designed for continuous-duty use in the lab. Digital models offer a timer and exact speed control for applications that demand repeatable results and non-digital variable speed models are an economical alternative. The high-speed and small orbit of these mixers make them optimal for effectively mixing microplates.

Applications

ELISA Assays, PCR Preparations, Digestions, Cell Disruptions

Display

Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)

Operation

Detachable 3-wire cord and plug (included)

Communication

N/A

Construction

Cycoloy

Design Features

Microplate adapter and cup head (included)

 

Specifications:

 

 

  • Control:Analog
  • Duty Rating:Continuous
  • Orbit:0.1 in (3.5 mm)
  • Speed Range:On Mode, 300 rpm – 2500 rpm;  Touch Mode, 300 rpm – 3500 rpm
  • Capacity:2 Microplates
  • Dimensions (HxLxW):4.5 in x 10.5 in x 5.4 in (11.4 cm x 26.7 cm x 13.7 cm)
  • Net Weight:11.7 lb (5.3 kg)
  • Power:120V, 0.25A, 50/60Hz
  • Power Consumption:30 W
  • Safety Certification:TUV

 

  • Working Environment:39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing)
Learn More
Ohaus-VXMPAL-*NEW*-Vortexer-20247
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1312A HPLC Binary Pump

Agilent 1100 Series - G1312A HPLC Binary Pump

Cambridge Scientific ID #'s: 15626, 16317, 15936, 16119, 19156, 16034, 13406, 23208, 12452

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1312A-HPLC-Binary-Pump-15626
By clicking below we can further assist you with your inquiry. Inquire 9 In Stock Worldwide Shipping
Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cohesive Technolgies 1100 Series - G1312A HPLC Binary Pump

Cambridge ID #: 11053

Specifications:

  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments
  • Flow range 1 - 5.0 ml/min
  • Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
  • Pressure: Operating range 0 400 bar (0 - 5880 psi) up to 5 ml/min
  • Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
  • Compressibility compensation: User-selectable, based on mobile phase compressibility
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluation

 

Can be sold as an individual component or as part of a complete stack

Learn More
Cohesive-Technolgies-1100-Series---G1312A-HPLC-Binary-Pump-11053
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1313A HPLC Autosampler

Agilent 1100 Series - G1313A HPLC Autosampler

Cambridge ID #: 16066

Specifications:

  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Learn More
Agilent-1100-Series---G1313A-HPLC-Autosampler-16066
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Agilent 1100 Series - G1321A HPLC Fluorescence Detector

Cambridge Scientific ID #'s: 11836, 22335, 16041, 22114, 17969, 13408, 16314, 16001, 15723, 10262

Optimized sensitivity and selectivity, for reliable quantitative and qualitative information

 

The Agilent 1100 Series fluorescence detector provides high-sensitivity multisignal detection, online fluorescence spectra, straightforward Operation and maintenance, and built-in features for GLP compliance.

  • Simplified optical design for optimized baseline stability.
  • Long-life Xenon lamp for highest sensitivity.
  • Variable-mode monochromators for selective multisignal detection and online spectra acquisition.
  • Easy front access to flow cell for fast inspection or exchange.

 

Specifications

  • Detection type:  Multisignal fluorescence detector with rapid online scanning capabilities and spectral data analysis
  • Performance:  10 fg anthracene LOD, Ex 250 nm, Em 400 nm*, Raman (H20) >400 Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Light source: Xenon flash lamp, normal mode (20W) and economy mode (5W)
  • Pulse frequency: 296 Hz for signal mode, 74 Hz for economy mode
  • Excitation monochromator: Concave holographic grating, F/1.6, blaze 300 nm, range 200—700 nm and zero-order, bandwidth 20 nm
  • Emission monochromator: Concave holographic grating, F/1.6, blaze 400 nm, range 280—900 nm and zero-order, bandwidth 20 nm
  • Reference system: Inline excitation measurement
  • Time programing: Up to 4 signals, response time, PMT gain, baseline behaviour (append, free, zero), spectral parameters
  • Spectral acquisition: Excitation or emission spectra, scan speed 28 ms per datapoint, e.g. 0.6 s per spectrum 200—400 nm, 10 nm step
  • Step size: 1—20 nm
  • Spectra storage: Limited only by disk space
  • Wavelength repeatability: ±0.2 nm
  • Wavelength accuracy: ±3 nm
  • Flow cells: Standard: 8 µl volume, 20 bar (2 MPa) pressure maximum, quartz
  • Control and data evaluation: Agilent ChemStation for HPLC or Agilent 1100 Series control module with limited spectral data analysis and printing of spectra
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, 2 outputs
  • Communications: Controller-area network (CAN), HP-IB, RS-232C, LAN, APG Remote: ready, start, stop and shut-down signals
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Learn More
Agilent-1100-Series---G1321A-HPLC-Fluorescence-Detector-11836
By clicking below we can further assist you with your inquiry. Inquire 10 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge ID #: 16028

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 23960, 17971, 13182, 23203, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack