Used Lab Equipment

Used Lab Equipment

We offer an assortment of refurbished and used Liquid Chromatography solutions ranging from HPLC, LC/MS to FPLC. Our systems can be customized to include almost any configuration of Autosamplers, Detectors and Pumps. Some of our leading manufacturers include Agilent, HP, Waters, GE, Amersham, Dionex and Shimazdzu. Our HPLC systems such as the Agilent 1100 and 1200 Series, Akta FPLCs, and the Waters Alliance & 600 series have the option of on site training, installation and extended warranties.

Spectrophotometer Visible/absorbance Reader: 46-60 of 106

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Molecular Devices Spectramax 250 Microplate UV/VIS Reader

Molecular Devices Spectramax 250 Microplate UV/VIS Reader

Cambridge ID #: 17245

Includes:

  • Computer Loaded with SoftMax Pro 5.4.1
  • All Necessary Cables and Cords
  • Manuals

 

The SPECTRAmax 250 microplate spectrophotometer has a xenon flash lamp and grating monochromator that facilitate direct UV measurement of DNA- RNA- and protein in microplates. Up to 96 assays can be run at one time using disposable or quartz microplates. The purity of DNA can be measured with A260/A280 ratios. Also- users can perform spectral scans from 250 nm to 750 nm to simplify qualitative analyses of numerous samples. The product reportedly reduces sample volumes in experiments because the assays are performed in a microplate instead of cuvettes. SOFTmax PRO microplate data- analysis software- for use with the SPECTRAmax 250- provides built-in spreadsheet capabilities for easy data analysis and reporting.

Specifications:

  • Wavelength Range: 250-700 nm
  • Photometric Range: 0.000 to 4.000 OD
  • Wavelength Selection: Monochromator, tunable in 1-nm increments
  • Photometric Linearity (405 nm): 0 to 3.000 OD
  • Wavelength Bandwidth: 5 nm
  • OD Resolution: 0.001 OD
  • Endpoint Read Time: 9 seconds
  • Temperature Range: Ambient to 45 C
  • Kinetic Read Time: 9-second minimum interval
  • Temperature Uniformity (Microplate): +/-0.5 C @ 37 C well-to-well

 

Learn More
Molecular-Devices-Spectramax-250-Microplate-UV-VIS-Reader-17245
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Molecular Devices SpectraMax 340PC Microplate UV/VIS Reader

Molecular Devices SpectraMax 340PC Microplate UV/VIS Reader

Cambridge Scientific ID #'s: 12898, 7496, 12899

Includes:

  • Computer Loaded with Softmax Pro 5.4.1
  • All Necessary Cables and Cords
  • Manuals

 

General Specifications

  • Dimensions (in.): 8.6 (h) x 22.8 (w) x 15 (d)

 

Performance Specifications

  • Wavelength Range: 340 - 850 nm
  • Wavelength Selection: Monochromator, tunable 1.0 nm increments
  • Wavelength Bandwidth: 2 nm
  • Wavelength Accuracy: < ± 1.0 nm
  • Wavelength Repeatability: ± 0.2 nm
  • Photometric Range: 0.0 to 4.0 OD
  • Photometric Accuracy: < ± 0.006 OD ± 1.0%, 0.0 - 2.0 OD
  • Photometric Precision: < ± 0.003 OD ± 1.0%, 0.0 - 2.0 OD
  • Light Source: Xenon flash lamp
  • Temperature Range: Ambient + 4 °C up to 45 °C
  • Temperature Uniformity: ± 0.5 °C @ 37 °C

 

Microplate Read Time:

  • Endpoint
    • 96-well: 9 seconds
    • 384-well: 29 seconds
  • Kinetic
    • 96-well: 9 second minimum interval
    • 384-well: 29 second minimum interval
Learn More
Molecular-Devices-SpectraMax-340PC-Microplate-UV-VIS-Reader-12898
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Molecular Devices SpectraMax M2 Multimode Microplate Reader

Molecular Devices SpectraMax M2 Multimode Microplate Reader

Cambridge Scientific ID #'s: 20670, 18788, 16123

Premier dual-mode readers for absorbance & fluorescence intensity-based assays. Users can select from top- or bottom-read modes for improved sensitivity for solution and cell-based assays.

 

Includes:

  • SoftMax Pro software version 5.4.1
  • Computer Workstation w/ Flat Screen Monitor
  • Complete Set of Communication & Power Cables
  • User/Reference Manuals for M2 and SoftMax Pro software

 

Specifications:

 

  • Absorbance Photometric Performance
  • Wavelength range: 200-1000 nm
  • Wavelength selection: Monochromator
  • Wavelength bandwidth: ≤ 4.0 nm
  • Wavelength accuracy: ±2.0 nm
  • Wavelength repeatability: ±0.2 nm

 

Fluorescence Photometric Performance (M2)

 

  • Dual monochromators: 1 nm increments
  • EX 250-850 nm
  • EM 360-850 nm
  • Bandwidth (EX, EM): 9, 9 nm
  • Detection limit: 3.0 fmol/well FITC 200 μL in 96 wells
Learn More
Molecular-Devices-SpectraMax-M2-Multimode-Microplate-Reader-20670
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Molecular Devices SpectraMax M2e Multimode Microplate Reader

Molecular Devices SpectraMax M2e Multimode Microplate Reader

Cambridge Scientific ID #'s: 19768, 22757

Premier dual-mode readers for absorbance & fluorescence intensity-based assays. Users can select from top- or bottom-read modes for improved sensitivity for solution and cell-based assays.

 

Includes:

  • SoftMax Pro software version 5.4.1
  • Computer Workstation w/ Flat Screen Monitor
  • Complete Set of Communication & Power Cables
  • User/Reference Manuals for M2 and SoftMax Pro software

 

Specifications:

 

  • Absorbance Photometric Performance
  • Wavelength range: 200-1000 nm
  • Wavelength selection: Monochromator
  • Wavelength bandwidth: ≤ 4.0 nm
  • Wavelength accuracy: ±2.0 nm
  • Wavelength repeatability: ±0.2 nm

 

Fluorescence Photometric Performance (M2)

 

  • Dual monochromators: 1 nm increments
  • EX 250-850 nm
  • EM 360-850 nm
  • Bandwidth (EX, EM): 9, 9 nm
  • Detection limit: 3.0 fmol/well FITC 200 μL in 96 wells
Learn More
Molecular-Devices-SpectraMax-M2e-Multimode-Microplate-Reader-19768
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Molecular Devices Spectramax M5 Multimode Microplate Reader

Molecular Devices Spectramax M5 Multimode Microplate Reader

Cambridge Scientific ID #'s: 17000, 16477, 19342, 19292, 17180

The SpectraMax M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change filters. The SpectraMax M5 is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates.

 

Includes:

  • Computer w/ Softmax Pro 5.4
  • Manuals
  • Cables

 

Multiple detection modes

  • UV-Visible Absorbance (Abs)
  • Fluorescence Intensity (FI)
  • Time-Resolved Fluorescence (TRF)
  • Fluorescence Polarization (FP)
  • Glow Luminescence (Lumi)

 

Features

  • Multiple Detection Modes
  • Precision Optics and Detectors
  • Patented AutoPMT Optimization System
  • Patented PathCheck® Pathlength Measurement Technology
  • Comprehensive Reader Validation
  • Automating with Ease

 

General Photometric performance

 

Plate Formats

  • 6, 12, 24, 48, 96, 384 wells

Light Source

  • Xenon Flash Lamp (1 joule/flash)

Detectors

  • 2 photomultiplier tubes

ShakerTime

  • 0 to 999 seconds

Temperature Control

  • 2 °C above ambient to 60 °C

Temperature Uniformity

  • < 1°C at 37°C set point

Temperature Accuracy

  • ±1°C at 37°C set point

Endpoint Reading

  • All modes

Kinetic Reading

  • All modes

Spectral Scanning

  • All modes

Well Scanning

  • Abs, FI, TRF, Lum
Learn More
Molecular-Devices-Spectramax-M5-Multimode-Microplate-Reader-17000
By clicking below we can further assist you with your inquiry. Inquire 5 In Stock Worldwide Shipping
Molecular Devices SpectraMax M5e Multimode Microplate Reader

Molecular Devices SpectraMax M5e Multimode Microplate Reader

Cambridge ID #: 20644

The SpectraMax M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change filters. The SpectraMax M5 is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates.

 

Includes:

  • Computer w/ Softmax Pro 5.4
  • Manuals
  • Cables

 

Multiple detection modes

  • UV-Visible Absorbance (Abs)
  • Fluorescence Intensity (FI)
  • Time-Resolved Fluorescence (TRF)
  • Fluorescence Polarization (FP)
  • Glow Luminescence (Lumi)

 

Features

  • Multiple Detection Modes
  • Precision Optics and Detectors
  • Patented AutoPMT Optimization System
  • Patented PathCheck® Pathlength Measurement Technology
  • Comprehensive Reader Validation
  • Automating with Ease

 

General Photometric performance

 

Plate Formats

  • 6, 12, 24, 48, 96, 384 wells

Light Source

  • Xenon Flash Lamp (1 joule/flash)

Detectors

  • 2 photomultiplier tubes

ShakerTime

  • 0 to 999 seconds

Temperature Control

  • 2 °C above ambient to 60 °C

Temperature Uniformity

  • < 1°C at 37°C set point

Temperature Accuracy

  • ±1°C at 37°C set point

Endpoint Reading

  • All modes

Kinetic Reading

  • All modes

Spectral Scanning

  • All modes

Well Scanning

  • Abs, FI, TRF, Lum
Learn More
Molecular-Devices-SpectraMax-M5e-Multimode-Microplate-Reader-20644
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1315A HPLC Diode Array Detector

Agilent 1100 Series - G1315A HPLC Diode Array Detector

Cambridge ID #: 19152

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315A-HPLC-Diode-Array-Detector-19152
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

Hewlett Packard 1100 Series - G1315A HPLC Diode Array Detector

Cambridge Scientific ID #'s: 22326, 22336

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Hewlett-Packard-1100-Series---G1315A-HPLC-Diode-Array-Detector-22326
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1100 Series - G1315B HPLC Diode Array Detector

Agilent 1100 Series - G1315B HPLC Diode Array Detector

Cambridge Scientific ID #'s: 22467, 16038, 22469

The Agilent 1100 Series G1315 Diode Array Detector is designed for the maximum optical performance. Flexible slit setting from fine bands to highest sensitivity, with settings of 1 nm the fine structure of benzene can be revealed - even at 0.7mAUFS. A broad slit of 8 or 16nm can be chosen to minimize baseline noise thus enhancing sensitivity. System specifications include:

 

Specifications:

  • Wavelength range: 190-950 nm
  • Light source: Deuterium and tungsten lamps
  • Detection type: 1024 - element photodiode array
  • Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
  • Drift: 2° x 10-3 AU / hr at 254 nm
  • Linear absorbance range: > 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 - 400 nm
  • Diode width: < 1 nm
  • Control and data evaluation: Agilent Chemstation for LC
  • Slit width: 1, 2, 4, 8, 16 nm

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1315B-HPLC-Diode-Array-Detector-22467
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364A HPLC Fraction Collector

Agilent 1100 Series - G1364A HPLC Fraction Collector

Cambridge Scientific ID #'s: 16335, 17472, 17967

Features:

 

  • G1364A Thermostatted Fraction Collector, preparative scale, can be created by additionally ordering and installing a G1330A Fraction Collector Thermostat

  • For preparative scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364A-HPLC-Fraction-Collector-16335
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364C HPLC Fraction Collector

Agilent 1100 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 16028, 16350, 16188

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364C-HPLC-Fraction-Collector-16028
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1100 Series - G1364D HPLC Fraction Collector

Agilent 1100 Series - G1364D HPLC Fraction Collector

Cambridge ID #: 17700

For Preparative Scale Applications

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1364D-HPLC-Fraction-Collector-17700
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365A HPLC Multi-Wavelength Detector

Cambridge ID #: 11049

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365A-HPLC-Multi-Wavelength-Detector-11049
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector

Cambridge Scientific ID #'s: 17971, 13182, 16326, 21821

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1100-Series---G1365B-HPLC-Multi-Wavelength-Detector-17971
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1260 Series - G1315D HPLC Diode Array Detector

Agilent 1260 Series - G1315D HPLC Diode Array Detector

Cambridge ID #: 20570

Features:

The detector is designed for highest optical performance, GLP compliance and easy maintenance. 

Specifications:

  • Detection Type: 1024-element photodiode array
  • Light Source: Deuterium and tungsten lamps The UV-lamp is equipped with RFID tag that holds lamp typical information.
  • Data Rate: up to 80 Hz
  • Wavelength Range: 190 – 950 nm
  • Short Term: noise (ASTM) Single and Multi-Wavelength: < ± 0.7·10-5 AU at 254 and 750 nm
  • Drift: < 0.9·10-3 AU/h at 254 nm 
  • Linear Absorbance Range: > 2 AU (5 %) at 265 nm
  • Wavelength Accuracy: ± 1 nm ,Self-calibration with deuterium lines, verification with holmium oxide filter
  • Wavelength Bunching: 1 – 400 nm, Programmable in steps of 1 nm
  • Slit Width: 1, 2, 4 , 8, 16 nm Programmable slit
  • Diode Width: < 1 nm
Learn More
Agilent-1260-Series---G1315D-HPLC-Diode-Array-Detector-20570
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping