REPLIGEN KR2i Peristaltic Pump

Cambridge Scientific ID: 28503 Category: Tag:

Description

Single-use fully integrated benchtop TFF system for use in lab scale process development ranging from 2mL – 15L. Compatible with hollow fiber or flat sheet filters, this system offers many user-defined set-point controls so you can run complex applications in fully-automated modes.

KrosFlo KR2i TFF systems achieve an unparalleled combination of configurability and user-simplicity through modular, plug-and-play hardware. All components, either directly or indirectly, connect to the main pump, which then communicates with the KF Comm 2 software for control and monitoring. The Fully integrated KrosFlo KR2i TFF System features a digital peristaltic pump, graphical LCD display, digital pressure monitor, KR2i Pump head, automatic back pressure valve, filter module stand, and KF Comm real-time data collection software. 

Specifications;

KrosFlo TFF System:

  • Filter Mode:                                                     Hollow Fiber                  Flat Sheet Cassettes
  • Recommended Process Volume:              2 mL- 10 L                              12 mL – 15 L 
  • Filter Surface Area:                                  13 cm²-3700 cm²                 100 cm² – 5000 cm²
  • Main Drive / Feed Pump and Stand:
        • Easy-Load Pump Head-ip to 2.3 LPM (600 RPM)
        • Use with tubing sizes #13, #14, #16, #17, #18 and #25.
        • Integrated stand for hollow fibers
  • Automatic Backpressure Control Valve (ABV): Controls user-set process TMP or permeate pressure
  • Tablet as HMI: Microsoft Surface Pro with Krosflo RPM control and data acquisition software
  • Auxiliary Pump: KorsFlo Junior, flowrates up to 0.3 LPM
  • System Scales:
        • Maximum Weight: 20,000 g
        • Readability: 0.1 g
        • Platform Dimensions: 7.7” x 7.7” (17.8 cm x 17.8 cm)
  • Enclosures: IP33 rated plastic enclosure. Wipe down cleanable. 
  • Environmental Requirements: 
        • Operating Temperature: 0°C – 40°C
        • Relative Humidity: 10% – 90%

CTech FlowVPX System:

  • Linear Range-Finger Technology: Automatically identifies linear region of absorbance data to verify compliance with Beer-Lambert Law 
  • Flow Cell Volume: 
        • 3 mm Flow Cell: 0.9 mL
        • 10 mm Flow Cell: 9.0 mL
  • Spectroscopic Engine: Agilent Cary 60
  • Qualification Slope Range: 0.10 Au/mm to 46 Au/mm using NIST-traceable slope standards
  • Qualification Slope Range: ±2%
  • Maximum Pathlength:
        • 3 mm Flow Cell: 3.000 mm
        • 10 mm Flow Cell: 5.000 mm
        • Minimum Pathlength Step: 0.001 mm
        • Delivery Fiber Length: 3 m

KONDUiT Add-On Monitor

  • Inputs: 2 Conductivity Inputs, 2 Temperature Inputs
  • Sensor Size: ¼” HB and ½” HB
  • Conductivity Range: 0.1 to 100 mS/cm
  • Conductivity Accuracy:
        • 0.1 mS/cm–2 mS/cm: ±0.1 mS/cm
        • 2 mS/cm–50 mS/cm: ±5%
        • 50 mS/cm–100 mS/cm: ±5% (Typical)
        • Temperature Range: 0°C–70°C
        • Temperature Accuracy: ±0.2°C or better

Auxiliary Components:

  • Pressure transducer: 
      • Up to 3 single-use sensors
      • Pressure Range: -7 to 75 psi (-0.48 to 5.2 bar)
      • Polysulfone, luer-style ports
  • Tubing: PharmaPure, TPE, size #14 and #16
  • Stand: Integrated stand with hollow fiber holder
  • Auxiliary Component Octopus cable: Allows for connectivity of scales, auxiliary pumps, and KONDUiT System
  • Reservoirs (Optional): 15 mL, 50 mL, 250 mL, 500 mL polypropylene conical containers, caps with ported inlets, conical holders
  • High-Performance pump head(Optional): 
    • High-performance pump head, up to 2.9 LPM
    • For use with tubing sizes #15, #24, #35, and #36
    • Note: Pump will accept up to two (2) pump heads

Power Requirements:

  • KR2i System: 
        • Supply voltage: 90–260 Vrms @ 50/60 Hz (universal input)
        • Max current: 2.2 A @ 115 Vrms or 1.1 A @ 230 Vrms
  • Cary 60: 90 VAC–265 VAC, frequency 47 Hz–63 Hz
  • VPX power input: 24 VDC, 0.6 A max current draw
  • KONDUiT
        • Input power supply range: 100 VAC–240 VAC
        • Input Frequency: 47 Hz–63 Hz
        • KONDUiT Power input: 24 VDC, 0.625 A max current draw
  • FlowVPX:
        • Power supply input: 100 VAC–230 VACFrequency: 50 Hz–60 Hz

General:

  • Dimensions: 
        • KR2i Main pump: 267 × 203 × 203 mm (10.5” × 8” × 8”)
        • Auxiliary Pumps (2): 140 x 178 x 160 mm (5.5” x 7” x 6.3”)
        • KONDUiT: 197 x 120 x 114 mm (7.75” x 4.75” x 4.5”)
        • Scales (2): 330 x 203 x 97 mm (13” x 8” x 3.8”)
        • FlowVPX: 120 x 100 x 230 mm (4.72” x 3.94” x 9.06”)
        • Cary 60: 483 x 559 x 203 mm (22” x 8” x 19”)
  • Weights: 
        • KR2i Main pump: 5.9 kg (13 lb)
        • Auxiliary Pumps (ea): 2.2 kg (4.8 lb)
        • Konduit: 1.6 kg (3.53 lb)
        • Scales (ea): 2.7 kg (6 lb)
        • Cary 60: 18.1 kg (40lb)
        • FlowVPX (3 mm flow cell): 4.31 kg (9.5 lb)

Contact Us

Thank you for your interest in the REPLIGEN KR2i Peristaltic Pump (SKU:28503) To speak with a representative, please fill out the contact form below or call us directly.

Product Inquiry
First
Last