Used Lab Equipment

Used Lab Equipment

We offer an assortment of used and refurbished Incubators ranging from General purpose Incubators, C02 Incubators, C02 water-jacketed Incubators, Refrigerated Incubators, and Shaking Incubators to Environmental Incubators and Humidity Incubators. Some of our popular manufacturers include Fisher, VWR, Thermo Forma, Precision, Sanyo and Hereaus.

Flow Cytometry: 46-60 of 273

*Please Select a Category and/or Manufacturer dropdown OR Search By Model Name, # or Keyword.* Advanced Search >
Agilent 1200 Series - G1379B HPLC Degasser

Agilent 1200 Series - G1379B HPLC Degasser

Cambridge Scientific ID #'s: 22387, 20389, 22622

Comprises a 4-channel vacuum container, including 4 tubular plastic membranes, and a vacuum pump.

 

Specifications:

  • Maximum flow rate:
    • 10 ml/min per channel
    • 5-10 ml/min per at reduced degassing performance
  • Number of channels: 4
  • Internal volume per channel: Typically 12 ml per channel
  • Materials in contact with solvent: PTFE, PEEK
  • pH range: 1 – 14
  • Analog output (AUX): For pressure monitoring, range 0 – 3 V

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1379B-HPLC-Degasser-22387
By clicking below we can further assist you with your inquiry. Inquire 3 In Stock Worldwide Shipping
Agilent 1200 Series - G1316A HPLC Column Compartment

Agilent 1200 Series - G1316A HPLC Column Compartment

Cambridge Scientific ID #'s: 25604, 24949, 25084, 24128, 24719, 23962

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1316A-HPLC-Column-Compartment-25604
By clicking below we can further assist you with your inquiry. Inquire 6 In Stock Worldwide Shipping
Agilent 1260 Infinity Series- G1311B HPLC Quaternary Pump

Agilent 1260 Infinity Series- G1311B HPLC Quaternary Pump

Cambridge ID #: 19976

Features:

This versatile and highly reliable pump offers flow rates up to 10 mL/min and pressures up to 600 bar. It is suited for the use of smaller particle size columns giving higher resolution and faster separations. It maintains virtually pulse-free, well mixed and stable solvent flows. Its dual floating, precise servo-controlled pistons adjust the stroke volume according to your chosen flow rate. Offering access to up to four solvents, the 1260 Infinity II Quaternary Pump provides the greatest flexibility in automated solvent blending. It is recommended for a wide range of research and routine applications (especially in the food, environmental and pharmaceutical sectors) as well as for method development.

Specifications:

  • Higher resolution, faster separations - the maximum pressure of 600 bar allows you to use smaller particle size columns, longer columns and/or higher viscous solvents as an alternative to acetonitrile.
  • Analytical and semi-preparative purifications - the wide flow range (up to 10 mL/min) perfectly supports standard and semi-preparative applications. The perfect choice for 4.6 and 3.0 mm id columns.
  • Quicker experiments - the pump offers convenient access to up to four solvents for isocratic or gradient analysis, which can really speed up method development, preparation of mobile phases and system flushing. 
  • Easy, fast and secure transfer of methods - from conventional to sub-2-micron columns.
  • Integrated degasser
  • Longevity and low operating costs - robust materials (stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE) withstand the most demanding applications and keep your pump functioning for years. Our optional seal wash for high-salt mobile phases keeps maintenance to a minimum and reduces operating costs.
Learn More
Agilent-1260-Infinity-Series--G1311B-HPLC-Quaternary-Pump-19976
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Agilent 1200 Series - G1330B HPLC Autosampler Chiller / Thermostat

Cambridge Scientific ID #'s: 24720, 23961, 25377, 24073

Specifications:

  • Detection type: 1024-element photodiode array
  • Light source: Deuterium and tungsten lamps
  • Wavelength range: 190 – 950 nm
  • Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
  • Drift: 2 × 10-3AU/hr at 254 nm
  • Linear absorbance Range: 2 AU (upper limit)
  • Wavelength accuracy: ± 1 nm
  • Wavelength bunching: 1 – 400 nm
  • Slit width: 1, 2, 4 , 8, 16 nm
  • Diode width: < 1 nm
  • Flow cells
    • Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
    • Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
    • High pressure: 1.7 µl volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
    • 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
  • Control and data Evaluation: Agilent ChemStation for LC
  • Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
  • Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
  • GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

 

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1330B-HPLC-Autosampler-Chiller---Thermostat-24720
By clicking below we can further assist you with your inquiry. Inquire 4 In Stock Worldwide Shipping
Agilent 1260 Series - G1310B HPLC Isocratic Pump

Agilent 1260 Series - G1310B HPLC Isocratic Pump

Cambridge Scientific ID #'s: 20799, 17964

The Agilent Technologies 1200 Series (G1310B) 1260 Infinity Isocratic Pump is a HPLC workhorse for demanding QA/QC and routine applications, designed to provide virtually pulse-free and stable solvent flow. This delivery principle allows variable stroke volume optimized to selected flow rate. The broadened pressure range with maximum pressure of 600 bar allows the use of small particle size columns, longer columns, or alternative solvents of higher viscosity. Additionally, the G1310B is the ideal pump for GPC/SEC applications where run-to-run and day-to-day precision of retention times are important.

 

Specifications:

  • Settable flow range: set points 0.001 - 5 mL/min, in 0.001 mL/min increments
  • Flow range: 0.2 to 10.0 mL/min
  • Flow precision: ≤ 0.07 % RSD or ≤ 0.02 min SD
  • Flow accuracy: ± 1 % or 10 μL/min whatever is greater, pumping degassed H2O at 10 MPa (100 bar)
  • Pressure operating range:
    • Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 mL/min
    • Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 mL/min
Learn More
Agilent-1260-Series---G1310B-HPLC-Isocratic-Pump-20799
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1364C HPLC Fraction Collector

Agilent 1200 Series - G1364C HPLC Fraction Collector

Cambridge Scientific ID #'s: 25481, 25601

Features:

 

  • G1364C Fraction Collector, analytical scale, designed for flow rates below 10 ml / min. (can be modified for higher flow rates) and for the use with vials, test tubes of up to 75 mm height, well-plates and a 40-funnel tray connecting to external locations of any size 
  • For analytical scale applications

 

Specifications:

  • Trigger Modes: Time slices, Peak (threshold, up- /downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323BControl Module)
  • Operating Modes: Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel position Continuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste
  • Test tube /plate sizes: Minimum 48 mm to 100 mm maximum
  • Maximum tube volume: ca. 45 ml
  • Maximum flow rate: 100 ml / min (depending on viscosity and generated back pressure, max. 6 bar at the diverter valve)
  • Delay volumes [μl]:
    • Fraction collector inlet to diverter valve: -500 (typical, depends on length of the tubing)
    • Diverter valve: ~15
    • Diverter valve to needle: ~110
    • Needle: -~5
  • Delay calibration Sensor: Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode
  • Diverter Valve: 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar
  • Cooling: Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions
  • Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve
  • GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
  • Interfaces: Controller-area network (CAN). optional; LAN or external contacts interface RS232C, APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves
  • Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors

Can be sold as an individual component or as part of a complete stack

Learn More
Agilent-1200-Series---G1364C-HPLC-Fraction-Collector-25481
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Agilent 1200 Series - G1367B HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 24077, 25603

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367B-HPLC-Well-Plate-Autosampler-24077
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1260 Series - G4225A HPLC Degasser

Agilent 1260 Series - G4225A HPLC Degasser

Cambridge ID #: 25656

The Agilent 1260 Infinity HPLC G4225A high performance degasser is comprised of four separate vacuum chambers with semipermeable tubings, a vacuum pump and control assembly. When the vacuum degasser is switched on, the control assembly turns on the vacuum pump, which generates a low pressure in the vacuum chambers. The pressure is measured by a pressure sensor. The vacuum degasser maintains the low pressure by a controlled leak in the air inlet filter and a regulation of the vacuum pump using the pressure sensor. The LC pump draws the solvents from their bottles through the semipermeable tubes of the vacuum chambers. When solvents pass through the vacuum chambers any dissolved gas in the solvents permeates through the tubings into the vacuum chambers. The solvents will be degassed when leaving the outlets of the vacuum degasser.

Specifications:
Number of solvent channels: 4
Flow range: 0 – 10 mL/min per channel
Internal volume per channel: 0.45 mL per channel
Materials in contact with solvent: TFE/PDD Copolymer, FEP, PEEK
pH range: 1 – 14

Learn More
Agilent-1260-Series---G4225A-HPLC-Degasser-25656
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Agilent 1200 Series - G1367C HPLC Well Plate Autosampler

Cambridge Scientific ID #'s: 25480, 23958

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1367C-HPLC-Well-Plate-Autosampler-25480
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Waters 1525 HPLC Pump

Waters 1525 HPLC Pump

Cambridge Scientific ID #'s: 25367, 22188

The 1525 and 1525 with EF heads are integrated, high-pressure, binary HPLC pumps that feature on-board pulse dampening and efficient mixing. Their pulse-free solvent flow, from analytical to semi-preparative flow rates, makes them ideal for use with highly sensitive detectors.

Designed for use with 2 to 4.6 mm I.D. columns in routine LC and LC/MS applications, these pumps have a programmable flow-rate range of 0.00 to 10.00 mL/min in 0.01 mL increments.

Optional features:

  • Extended Flow (EF) heads for extended flow rate range up to 22.50 mL/min for use with 10 to 19 mm I.D. columns
  • 1500 Series Column Heater with a temperature range of 20 to 60 °C to maintain accurate, consistent column temperature
  • Integral vacuum degasser to remove dissolved gases from the mobile phase, improving performance and reliability
  • Automated seal wash helps extend the primary seal life for reliable operation
  • FlexInject manual dual injector module for both analytical and semi-preparative injections
Learn More
Waters-1525-HPLC-Pump-25367
By clicking below we can further assist you with your inquiry. Inquire 2 In Stock Worldwide Shipping
Agilent 1200 Series - G1367D HPLC AutosamplerImage Coming Soon

Agilent 1200 Series - G1367D HPLC Autosampler

Cambridge ID #: 25378

Description:

The G1367D Agilent 1200 Series High Performance Autosampler SL+ is specifically designed for the Agilent 1200 Series Rapid Resolution LC system for increased analysis speed with uncompromised sensitivity, resolution, precision and lowest carry over. Features increased pressure range (up to 600 bar) enabling the use of today’s column technology (sub-two-micron columns) with the Agilent 1200 Rapid Resolution LC System. Increased robustness by optimized new parts, high speed with lowest carry-over by flow through design, increased sample injection speed for high sample throughput, increased productivity by using overlapped injection mode and flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384-well plates allows you to process up to 768 samples unattended.

 

Features:

Injection range: 0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required)

Precision: Typically < 0.25% RSD from 5 – 40 µl, Typically < 0.5% RSD from 2 – 5 µl, Typically < 0.7% RSD from 1 – 2 µl volume

Pressure range: Up to 600 bar (8700 psi)

Sample viscosity: range 0.2 – 5 cp

Sample capacity: 2 × well plates (MTP) + 10 × 2 ml vials 108 x 2-mL vials in2 x 54 vial plate, plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate, plus 10 additional 2 mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate

Injection cycle time: Typically < 17 s

Carry-over: Typically < 0.004%

Learn More
Agilent-1200-Series---G1367D-HPLC-Autosampler-25378
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Thermo Forma 170051A - Digital One Heated/ Circulating Waterbath

Thermo Forma 170051A - Digital One Heated/ Circulating Waterbath

Cambridge ID #: 10819

Features:

 

Water Bath and Circulators



Specifications:

 

  • Capacity: 17L
  • Temperature range: 12C above ambient- 200C
  • Pump flow rate: 15L/min
  • Electrical: 115V, 60Hz, 1 PH, 16 Amps

 

Learn More
Thermo-Forma-170051A---Digital-One-Heated--Circulating-Waterbath-10819
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Pittsburgh Automotive 2.5 CFM - 98076 Vacuum Pump

Pittsburgh Automotive 2.5 CFM - 98076 Vacuum Pump

Cambridge ID #: 21339

Features:

Designed for deeper vacuum draw, this vacuum pump pulls vacuum down to 75 microns. Precision machined one-stage pump removes moisture from air conditioning systems to safely add refrigerant. This one stage vacuum pump is ideal for automotive air conditioning, HVAC work and other operations that require high vacuum pull from a compact pump.

  • One stage pump draws vacuum down to 75 micron
  • Durable die cast aluminum housing and convenient top handle for easy maneuvering
  • Easy-access oil fill port with viewing window for easy maintenance (oil included)
  • Dual ports for R134A and R12/R22 systems
  • Thermal and current overload protection

Specifications:

  • Capacity: 10 Pascal
  • AC Volts: 120
  • Flow rate: 2.5 CFM
Learn More
Pittsburgh-Automotive-2.5-CFM---98076-Vacuum-Pump-21339
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Agilent 1200 Series - G1376A HPLC Capillary Pump

Agilent 1200 Series - G1376A HPLC Capillary Pump

Cambridge ID #: 20388

The Agilent 1200 Series autosampler is designed for use with other modules of the Agilent 1200 Series LC system or with other LC systems if adequate remote control inputs and outputs are available. The autosampler is controlled from the Agilent 1200 Series control module or from the Agilent ChemStation

for LC systems.

Specifications:

  • Weight: 15.5 kg (34.2 lbs)
  • Dimensions (height × width × depth): 200 × 345 × 440 mm (8 × 13.5 × 17 inches)
  • Line voltage: 100 – 240 VAC, ±10 % Wide-ranging capability
  • Line frequency: 50 or 60 Hz, ±5 %
  • Power consumption (apparent power): 300 VA Maximum
  • Power consumption (active power): 200 W Maximum
  • Ambient operating temperature: 4 to 55 8C (41 to 131 8F)
  • Ambient non-operating temperature: -40 to 70 8C (-4 to 158 8F)
  • Humidity: < 95 %, at 25 to 40 8C (77 to 104 8F) Non-condensing
  • Operating Altitude: Up to 2000 m (6500 ft)
  • Non-operating altitude: Up to 4600 m (14950 ft) For storing the autosampler
Learn More
Agilent-1200-Series---G1376A-HPLC-Capillary-Pump-20388
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping
Fisher Scientific 230D Incubator

Fisher Scientific 230D Incubator

Cambridge ID #: 18021

This Fisher Scientific  230D Iincubator Oven has gravity flow circulation that provides seamless heating for accurate routine procedures.

Specifications:

  • Temperature range: 30°C to 75°C
  • Temperature uniformity: ±0.7°C
  • Temperature resolution: 0.1°C
  • Weight: 370 lb. ( 80 kg) 
  • Volume: 5 cubic feet
  • Dimensions (W x H x D):  23.5 x 26 x 39 in (60 x 66 x 99 cm)
Learn More
Fisher-Scientific-230D-Incubator-18021
By clicking below we can further assist you with your inquiry. Inquire 1 In Stock Worldwide Shipping